Loading...
HomeMy WebLinkAboutM203 - THIRD FLOOR MECHANICAL PLANAQUARIUM MAINT. 302 AQUARIUM MIKE OFFICE 6 331 BREAK ROOM 318 CONFERENCE ROOM 316 MEDICAL STORAGE 334 BLOOD DRAW 303 M. PRIDDY OFFICE 4 338 J. RIZZUTO OFFICE 5 339 EX 1 PATIENT RR 306B 307A EX 2 307B GENERAL STORAGE 332 OFFICE 1 335 OFFICE 3 337 PHARMACY & SAMPLES 304 OFFICE 7 330 MOLE MAPPING (PHOTO FINDER) 329 STORAGE 305 JANITOR 328 308A EX 3 308B LAB PROCEDURE ROOM 317 OFFICE 8 327 UNISEX RESTROOM 319 EXAM 10 PEDIATRIC 315A EX PED PATIENT RR 315B EX 4 309B OFFICE 9 OFFICE 10 325 EXAM 5 310A PROCEDURE & 323 SHOWER ROOM 320 EXAM 9 EX 9 PATIENT RR 314B EXAM 8 313A EX 8 PATIENT RR 313B 309A EX 5 PATIENT RR 310B EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B EXAM 6 EXAM 7 OFFICE 2 336 RECEPTION 300 WAITING LOUNGE 301 SOILED LINENS 321 BACK HALL 333 OPEN OFFICE 340 HALLWAY 341 HALLWAY 343 HALLWAY 345 HALLWAY EXISTING STAIR 2 NIC EXISTING STAIR 1 NIC DN DN ELEC. ROOM (EXIST.) NIC DW MF MF DS-1 70"x30" 55"x40" 60"x40" 77"x30" 73"x37" 60"x25" 54"x20" 30"x20" 8"ø 2 1 1 1 1 3 24"x20" 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø 8 4 5,570 CFM 5,570 CFM 6 6 7 14"x12" 18"x14" 6"ø EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 100 EG1- 75 18"x18" 14"x12" 28"x10" 6"ø 6"ø 6"ø 6"ø 10"ø 6"ø 6"ø 6"ø DSI-2 9 9 60"x20" 60"x20" VAV-307A VAV-309A VAV-311A VAV-314A VAV-313A VAV-316 VAV-306A VAV-300 VAV-336 VAV-338 VAV-340-B VAV-340-A VAV-330 VAV-326 VAV-323 VAV-331 S6- 125 S6- 125 S6- 125 S6- 125 14"x10" 14"x10" 10"ø 10"ø S6- 150 S6- 150 S6- 150 S6- 125 S6- 125 S6- 125 S6- 185 S6- 190 S1- 50 S6- 185 S6- 190 S6- 130 S6- 135 S6- 135 S6- 100 S6- 100 S6- 100 S6- 100 S6- 150 S6- 150 S6- 125 S6- 125 12"ø 16"ø S7- 100 S7- 100 S7- 100 S6- 125 S6- 125 S6- 125 S6- 125 S6- 185 S6- 190 S6- 150 S6- 150 S6- 150 S7- 100 S7- 100 S7- 100 S7- 100 S2- 100 S3- 125 S7- 100 S7- 100 S7- 100 S7- 100 S3- 150 S1- 50 S6- 150 S6- 150 VAV-317 S3- 120 S3- 120 S3- 120 S3- 120 S3- 120 S3- 120 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 100 S8- 115 S8- 115 S8- 115 S8- 115 24"x20" 22"x16" S1- 75 S3- 120 S6- 225 S6- 225 S6- 225 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG2 RG2 RG2 RG1 RG1 RG1 RG1 RG1 S7- 115 RG1 RG1 RG1 RG1 RG1 12"ø 8"ø 10"ø 10"ø 12"ø 8"ø 10"ø 10"ø 8"ø 10"ø 8"ø 10"ø 10"ø S3- 200 8"ø 6"ø 6"ø 6"ø 10"ø 10"ø 10"ø 10"ø 16"x14" 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 10"ø 16"x14" 12"x12" 8"ø 8"ø 12"ø 8"ø 8"ø 8"ø 8"ø 8"ø 20"x18" 12"ø 24"x20" T T T T T T T T T T T T T T T T T 8"ø 8"ø 8"ø 8"ø 16"ø 12"ø 16"x14" 8"ø 8"ø 8"ø 12"ø 8"ø 8"ø 24"x16" 16"x14" 8"ø 10"ø 8"ø 8"ø 8"ø 8"ø 6"ø 10"ø 8"ø 8"ø 14"x12" 14"x12" 12"x10" 10"ø 8"ø 10"ø 8"ø 6"ø 6"ø 12"ø 8"ø 10"ø 8"ø 12 TYP. 12"ø 14"x13" 8"ø 8"ø 10"ø 8"ø 8"ø 12"ø 8"ø 14"x14" 8"ø 16"ø 8"ø 8"ø 10"ø 8"ø 8"ø 6"ø 8"ø 14"ø 8"ø 8"ø 8"ø S8- 115 TYP. 12 13 TYP. 26"x20" 8"ø 10"ø 12"ø 8"ø 8"ø 8"ø 8"ø 8"ø 10"ø 12"x12" 8"ø 8"ø 8"ø 14"x12" 14"ø 14"ø 8"ø 12"ø 8"ø 12"ø 8"ø 8"ø 14"x12" 8"ø 12"x8" 8"ø 8"ø 60"x25" S6- 225 14 14 3/4" CD 15 7 DSI-3 S9- 200 14 S9- 200 S9- 200 S9- 200 14 S9- 200 14 Certified By: Scale: Date: Checked By: Drawn By: Job Number: Drawing Number: Drawing Name: CARMEL, IN 46032 PRIORITY PHYSICIANS 12.03.2020 Revisions: 12174 N. MERIDIAN SUITE 300 AS NOTED - - PERMIT SET 12.03.2020 M203 THIRD FLOOR MECHANICAL PLAN SCALE: 1/8" = 1'-0" 1 THIRD LEVEL MECHANICAL PLAN - PLAN NOTES: 1. EXISTING TO REMAIN. 2. 8"Ø RANGE HOOD EXHAUST DUCT UP TO ROOF. 3. CONNECT NEW SUPPLY DUCT TO EXISTING RTU-2 SUPPLY DUCT. 4. CONNECT NEW RETURN DUCT TO EXISTING RTU-2 RETURN DUCT. 5. CONNECT NEW EXHAUST DUCT TO EXISTING EF-1 EXHAUST DUCT. 6. TERMINATE RETURN DUCT WITH HARDWARE CLOTH OR EXPANDED METAL GRILLE. PROVIDE MANUAL BALANCE DAMPER. BALANCE TO CFM INDICATED. 7. 18"X14" EXHAUST DUCT UP TO EF-1. 8. 14"X14" EXHAUST DUCT DOWN TO SECOND FLOOR. SEE SECOND FLOOR MECHANICAL PLAN. 9. ROUTE 3/4" DRAIN FROM CONDENSATE PUMP TO MOP SINK IN AQUARIUM MAINTENANCE ROOM. 10. 18"X18" EXHAUST DUCT UP TO EF-2. 11. 28"X10" EXHAUST DUCT DOWN TO SECOND FLOOR. SEE SECOND FLOOR MECHANICAL PLAN. 12. TRANSFER AIR DUCT ABOVE CEILING. 13. PROVIDE SIDEWALL RETURN LOUVERED GRILLE FOR ALL OFFICES WITHOUT DROP CEILING. TRANSFER TO ADJACENT SPACE AS SHOWN TERMINATED OPEN ENDED ABOVE CEILING. 14. MOUNT DIFFUSER AT ELEVATION EQUAL TO LIGHT FIXTURE. 15. INTERNALLY LINE DUCT WITH ACOUSTIC 1" LINER. GENERAL NOTES: A. ALL DUCT DIMENSIONS GIVEN ARE OUTSIDE DIMENSIONED. B. COORDINATE ALL OPENINGS IN FLOORS, ROOF AND WALLS WITH THE GENERAL AND STRUCTURAL CONTRACTORS. C. RUN ALL DUCTS AS HIGH AS POSSIBLE WITH RETURN AND EXHAUST ABOVE SUPPLY AS OFTEN AS POSSIBLE. D. INSULATE ALL SUPPLY AIR AND OUTSIDE AIR DUCTWORK WITH 1.5" FIBERGLASS DUCT WRAP WITH FSK JACKET (R-5 MINIMUM). E. PROVIDE VOLUME BALANCING DAMPERS UPSTREAM OF ALL AIR INLET/OUTLETS UNLESS NOTED OTHERWISE. F. PROVIDE TURNING VANES IN ALL SUPPLY AIR SQUARE THROATED ELBOWS. G. ALL RECTANGULAR SUPPLY AIR BRANCH CONNECTIONS SHALL BE 45° TAKE-OFF FITTINGS AND ROUND SUPPLY AIR BRANCH CONNECTIONS SHALL BE BELLMOUTH FITTINGS. H. FLEXIBLE DUCTS TO DIFFUSERS MAXIMUM LENGTH 5'-0". FLEXIBLE DUCTS ARE NOT TO BE USED AS ELBOWS. I. RETURN DUCTWORK SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. J. ALL EXHAUST DUCTWORK FROM THE BOTTOM OF THE ROOF CURB TO THE BACK-DRAFT DAMPER SHALL BE EXTERNALLY INSULATED WITH 1.5" FIBERGLASS DUCT WRAP WITH FSK JACKET (R-5 MINIMUM). ALL OTHER EXHAUST DUCTWORK SHALL NOT BE INSULATED. N