Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M203 REVISED
DW MF MF DS-1 70"x30" 55"x40" 60"x40" 77"x30" 73"x37" 60"x25" 54"x20" 30"x20" 8"ø 2 1 1 1 1 3 24"x20" 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø 8 4 5,570 CFM 5,570 CFM 6 6 7 14"x12" 18"x14" 6"ø EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 75 EG1- 100 EG1- 75 18"x18" 14"x12" 28"x10" 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø 6"ø DSI-2 9 9 60"x20" 60"x20" VAV-307A VAV-309A VAV-311A VAV-314A VAV-313A VAV-316 VAV-306A VAV-300 VAV-336 VAV-338 VAV-340-B VAV-340-A VAV-330 VAV-326 VAV-323 VAV-331 S6- 125 S6- 125 S6- 125 S6- 125 14"x10" 14"x10" 10"ø 10"ø S6- 150 S6- 150 S6- 150 S6- 125 S6- 125 S6- 125 S6- 185 S6- 190 S1- 50 S6- 185 S6- 190 S6- 130 S6- 135 S6- 135 S6- 100 S6- 100 S6- 100 S6- 100 S6- 150 S6- 150 S6- 125 S6- 125 12"ø 16"ø S7- 100 S7- 100 S7- 100 S6- 125 S6- 125 S6- 125 S6- 125 S6- 185 S6- 190 S6- 150 S6- 150 S6- 150 S7- 100 S7- 100 S7- 100 S7- 100 S2- 100 S3- 125 S7- 100 S7- 100 S7- 100 S7- 100 S3- 150 S1- 50 S6- 150 S6- 150 VAV-317 S3- 120 S3- 120 S3- 120 S3- 120 S3- 120 S3- 120 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 125 S3- 100 S8- 115 S8- 115 S8- 115 S8- 115 24"x20" 22"x16" S1- 75 S3- 120 S6- 225 S6- 225 S6- 225 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG1 RG2 RG2 RG2 RG1 RG1 RG1 RG1 RG1 S7- 115 RG1 RG1 RG1 RG1 RG1 12"ø 8"ø 10"ø 10"ø 12"ø 8"ø 10"ø 10"ø 8"ø 10"ø 8"ø 10"ø 10"ø S3- 200 8"ø 6"ø 6"ø 6"ø 10"ø 10"ø 10"ø 10"ø 16"x14" 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 8"ø 10"ø 16"x14" 12"x12" 8"ø 8"ø 12"ø 8"ø 8"ø 8"ø 8"ø 8"ø 20"x18" 12"ø 24"x20" T T T T T T T T T T T T T T T T T 8"ø 8"ø 8"ø 8"ø 16"ø 12"ø 16"x14" 8"ø 8"ø 8"ø 12"ø 8"ø 8"ø 24"x16" 16"x14" 8"ø 10"ø 8"ø 8"ø 8"ø 8"ø 6"ø 10"ø 8"ø 8"ø 14"x12" 14"x12" 12"x10" 10"ø 8"ø 10"ø 8"ø 6"ø 6"ø 12"ø 8"ø 10"ø 8"ø 12 TYP. 12"ø 14"x13" 8"ø 8"ø 10"ø 8"ø 8"ø 12"ø 8"ø 14"x14" 8"ø 16"ø 8"ø 8"ø 10"ø 8"ø 8"ø 6"ø 8"ø 14"ø 8"ø 8"ø 8"ø S8- 115 TYP. 12 13 TYP. 26"x20" 8"ø 10"ø 12"ø 8"ø 8"ø 8"ø 8"ø 8"ø 10"ø 12"x12" 8"ø 8"ø 8"ø 14"x12" 14"ø 14"ø 8"ø 12"ø 8"ø 12"ø 8"ø 8"ø 14"x12" 8"ø 12"x8" 8"ø 8"ø 60"x25" 14 14 3/4" CD 15 DSI-3 S9- 200 14 S9- 200 S9- 200 S9- 200 14 S9- 200 14 J. RIZZUTO OFFICE 5 339 M. PRIDDY OFFICE 4 338 OFFICE 3 337 OFFICE 2 336 OFFICE 1 335 MEDICAL STORAGE EXISTING STAIR 334 1 NIC GENERAL STORAGE 332 RECEPTION 300 WAITING LOUNGE 301 AQUARIUM MAINT. 302 MIKE OFFICE 6 331 BLOOD DRAW 303 HALLWAY 341 PHARMACY & SAMPLES 304 EXAM 1 306A EX 2 PATIENT RR 307B EXAM 3 308A EXAM 2 307A STORAGE 305 JANITOR 328 MOLE MAPPING (PHOTO FINDER) 329 OFFICE 7 330 OPEN OFFICE 7 340 OFFICE 8 327 OFFICE 9 326 EX 3 PATIENT RR 308B HALLWAY 342 EX 4 PATIENT RR 309B EXAM 4 309A EX 5 PATIENT RR 310B EXAM 5 310A EXAM 6 310A EXAM 7 312A EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B PROCEDURE & BLOOD DRAW 323 BREAK ROOM 318 ELEC. ROOM (EXIST.) NIC PROCEDURE ROOM 317 EXISTING STAIR 2 NIC CONFERENCE ROOM 316 UNISEX RESTROOM 316 HALLWAY 346 EX PED PATIENT RR 315B EXAM 10 PEDIATRIC 315A EX 9 PATIENT RR 314B SHOWER ROOM 320 SOILED LINENS 321 EXAM 9 314A EXAM 8 313A EX 8 PATIENT RR 313B BACK HALL 333 HALLWAY 345 16 16 10"ø 3/4" CD 8"ø S6- 225 Certified By: Scale: Date: Checked By: Drawn By: Job Number: Drawing Number: Drawing Name: CARMEL, IN 46032 PRIORITY PHYSICIANS 12.03.2020 Revisions: 12174 N. MERIDIAN SUITE 300 AS NOTED - - PERMIT SET 12.03.2020 M203 THIRD FLOOR MECHANICAL PLAN SCALE: 1/8" = 1'-0" 1 THIRD LEVEL MECHANICAL PLAN - PLAN NOTES: 1. EXISTING TO REMAIN. 2. 8"Ø RANGE HOOD EXHAUST DUCT UP TO ROOF. 3. CONNECT NEW SUPPLY DUCT TO EXISTING RTU-2 SUPPLY DUCT. 4. CONNECT NEW RETURN DUCT TO EXISTING RTU-2 RETURN DUCT. 5. CONNECT NEW EXHAUST DUCT TO EXISTING EF-1 EXHAUST DUCT. 6. TERMINATE RETURN DUCT WITH HARDWARE CLOTH OR EXPANDED METAL GRILLE. PROVIDE MANUAL BALANCE DAMPER. BALANCE TO CFM INDICATED. 7. 18"X14" EXHAUST DUCT UP TO EF-1. 8. 14"X14" EXHAUST DUCT DOWN TO SECOND FLOOR. SEE SECOND FLOOR MECHANICAL PLAN. 9. ROUTE 3/4" DRAIN FROM CONDENSATE PUMP TO MOP SINK IN AQUARIUM MAINTENANCE ROOM. 10. 18"X18" EXHAUST DUCT UP TO EF-2. 11. 28"X10" EXHAUST DUCT DOWN TO SECOND FLOOR. SEE SECOND FLOOR MECHANICAL PLAN. 12. TRANSFER AIR DUCT ABOVE CEILING. 13. PROVIDE SIDEWALL RETURN LOUVERED GRILLE FOR ALL OFFICES WITHOUT DROP CEILING. TRANSFER TO ADJACENT SPACE AS SHOWN TERMINATED OPEN ENDED ABOVE CEILING. 14. MOUNT DIFFUSER AT ELEVATION EQUAL TO LIGHT FIXTURE. 15. INTERNALLY LINE DUCT WITH ACOUSTIC 1" LINER. 16. ROUTE 3/4" DRAIN FROM CONDENSATE PUMP TO OPEN SIGHT DRAIN. COORDINATE WITH PLUMBING DRAWINGS. PROVIDE ACCESS DOOR IN WALL. GENERAL NOTES: A. ALL DUCT DIMENSIONS GIVEN ARE OUTSIDE DIMENSIONED. B. COORDINATE ALL OPENINGS IN FLOORS, ROOF AND WALLS WITH THE GENERAL AND STRUCTURAL CONTRACTORS. C. RUN ALL DUCTS AS HIGH AS POSSIBLE WITH RETURN AND EXHAUST ABOVE SUPPLY AS OFTEN AS POSSIBLE. D. INSULATE ALL SUPPLY AIR AND OUTSIDE AIR DUCTWORK WITH 1.5" FIBERGLASS DUCT WRAP WITH FSK JACKET (R-5 MINIMUM). E. PROVIDE VOLUME BALANCING DAMPERS UPSTREAM OF ALL AIR INLET/OUTLETS UNLESS NOTED OTHERWISE. F. PROVIDE TURNING VANES IN ALL SUPPLY AIR SQUARE THROATED ELBOWS. G. ALL RECTANGULAR SUPPLY AIR BRANCH CONNECTIONS SHALL BE 45° TAKE-OFF FITTINGS AND ROUND SUPPLY AIR BRANCH CONNECTIONS SHALL BE BELLMOUTH FITTINGS. H. FLEXIBLE DUCTS TO DIFFUSERS MAXIMUM LENGTH 5'-0". FLEXIBLE DUCTS ARE NOT TO BE USED AS ELBOWS. I. RETURN DUCTWORK SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. J. ALL EXHAUST DUCTWORK FROM THE BOTTOM OF THE ROOF CURB TO THE BACK-DRAFT DAMPER SHALL BE EXTERNALLY INSULATED WITH 1.5" FIBERGLASS DUCT WRAP WITH FSK JACKET (R-5 MINIMUM). ALL OTHER EXHAUST DUCTWORK SHALL NOT BE INSULATED. N