HomeMy WebLinkAboutA1.1 Annotated FLoor PlanAQUARIUM
DW
MF
MF
MIKE
OFFICE 6
331
Certified By:
Scale:
Date:
Checked By:
Drawn By:
Job Number:
Drawing Number:
Drawing Name:
CARMEL, IN 46032
01.22.2021
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
PRIORITY PHYSICIANS ...creating profitable environments...
Revisions:
12174 N. MERIDIAN
SUITE 300
1/8"=1'-0"
1 ANNOTATED FLOOR PLAN
A
S NOTED
BSH
LOE
ANNOTATED FLOOR PLAN
A1.1
PERMIT SET 01.22.2021
# FLOOR PLAN KEYNOTES:
1. ALIGN FINISHED FACES.
2. TYPICAL: ALIGN NEW WALL WITH CENTER OF WINDOW MULLION. SEE 6/A1.2 FOR DETAILS.
3. PROVIDE ALLOWANCE FOR NEW CUSTOM CORNER WOOD BOOKCASE. ADDITIONAL DETAILS TO FOLLOW.
4. PAINT ALL EXPOSED EXISTING COLUMNS 'PT-X', UNLESS OTHERWISE NOTED.
5. CONTRACTOR TO PROVIDE AND INSTALL CEMENT BACKER BOARD FOR WALL TILE INSTALLATION,
FROM FLOOR TO CEILING AT ALL WALLS INSIDE WALK-IN SHOWER.
6. CONTRACTOR TO PROVIDE AND INSTALL GREEN BOARD ON WALLS, FROM FLOOR TO CEILING AT ALL
WALLS INSIDE THE AQUARIUM MAINTENANCE ROOM.
7. SMARTPERGOLA ELECTRICAL CONTROL BOX TO BE INSTALLED THIS APPROXIMATE LOCATION.
CENTER OF BOX TO BE MOUNTED AT 72" A.F.F. ELECTRICAL ENGINEER TO COORDINATE DIRECTLY WITH
SMART PERGOLA IN VERIFYING ALL POWER REQUIREMENTS. PROVIDE BLOCKING IN WALL TO
ACCOMMODATE SIZE OF CONTROL BOX.
8. CONTRACTOR TO PROVIDE AND INSTALL FLOOR DRAIN IN CENTER OF AQUARIUM MAINT. ROOM 302,
SLOPE FLOOR TO DRAIN AS REQUIRED.
9. PROVIDE ALLOWANCE FOR NEW CUSTOM RECEPTION DESK. ANTICIPATED FINISHES: WOOD AND TILE
FACE, METAL TOE KICK AND TRIM. PROVIDE $90/ SF INSTALLED QUARTZ TRANSACTION TOP AND WORK
SURFACE ALLOWANCE. REFERENCE ENLARGED PLAN FOR MORE DETAILS.
10. CONTRACTOR TO PROVIDE AND INSTALL FLOOR DRAIN IN THE SHOWER ROOM, SLOPE FLOOR TO DRAIN.
REFER TO PLUMBING PLANS FOR MORE DETAILS.
11. CONTRACTOR TO INSTALL PHANOMEN PROVIDED 'LIVING WALL' (GREEN WALL). NO PLUMBING OR
ELECTRICAL NEEDED. CONTACT PHANOMEN FOR DETAILS AND INSTALLATION INSTRUCTIONS.
12. CONTRACTOR TO COORDINATE TRANSFER OF EXISTING CONFERENCE TABLE AND CASEWORK W/ SINK
FROM THE CURRENT PRIORITY OFFICE TO NEW LOCATION AS SHOWN. CONTRACTOR TO TAKE EXTREME
CARE NOT TO DAMAGE ANY EXISTING MATERIALS WHILE REMOVING ITEMS FROM WALLS AND FLOOR.
CAREFULLY UNHOOK AND CAP ANY ELECTRICAL, PLUMBING, AND/OR AV/IT ITEMS AT THEIR SOURCES
BEFORE MOVING.
13. PROVIDE AND INSTALL FULL-HEIGHT WOOD PANTRY, SPECS T.B.D. SEE ELEVATION FOR DETAILS.
14. CONTRACTOR TO PROVIDE AND INSTALL BREAK ROOM BASE CABINETS W/ GRANITE COUNTERTOP
STAINLESS STEEL UNDERMOUNT DOUBLE SINK, SPEC. T.B.D. KITCHEN FAUCET BASIS OF DESIGN:
KOHLER/CRUE/TOUCHLESS PULL-DOWN SINGLE-HANDLE KITCHEN FAUCET IN VIBRANT STAINLESS
(K-22974-VS). SEE ELEVATION FOR DETAILS.
15. CONTRACTOR TO PROVIDE AND INSTALL METAL AND GLASS UPPER SHELVING. PROVIDE BLOCKING IN THE
CEILING FOR SUPPORT AS REQUIRED. SEE ELEVATION FOR DETAILS.
16. CONTRACTOR TO PROVIDE AND INSTALL BREAK ROOM ISLAND BASE CABINET AND QUARTZ COUNTERTOP.
SEE ELEVATION FOR DETAILS. REFER TO ELECTRICAL PLANS FOR OUTLET LOCATIONS AND HEIGHTS.
17. CONTRACTOR TO INSTALL NEW TENANT PROVIDED ELECTRIC STOVETOP, RANGE HOOD, REFRIGERATOR,
AND DISHWASHER. SEE MEP PLANS FOR POWER REQUIREMENTS AND REFERENCE FINAL ELEVATIONS FOR
ROUGH-IN LOCATIONS. CUT SHEETS SHALL BE REQUESTED DIRECTLY FROM TENANT.
18. EXISTING TENANT PROVIDED COPIER/PRINTER. REQUIRED DEDICATED OUTLET. SEE POWER PLANS.
19. PROVIDE AND INSTALL BASE CABINETS AND QUARTZ COUNTERTOP, MATCH STYLE TO TENANT EXISTING
(REFERENCE KEYNOTE #39 BELOW). SEE ELEVATION FOR DETAILS.
20. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS
STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. BASIS OF DESIGN FOR ALL AREAS WITH KEYNOTE 20:
KOHLER/CRUE SINGLE HANDLE BAR FAUCET/K-22975-VS, SINGLE HOLE. REFERENCE REFLECTED CEILING
PLAN FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS.
21. EXISTING TENANT REFRIGERATOR RELOCATED FROM FORMER OFFICE. COORDINATE POWER REQUIREMENTS
WITH TENANT. TIE TO ALARM SYSTEM. REFER TO MEP PLANS FOR MORE INFORMATION.
22. EXISTING VACCINE REFRIGERATOR/FREEZER. REFER TO POWER PLANS FOR MORE INFORMATION.
DEDICATED OUTLET MUST BE TIED INTO ALARM SYSTEM/GENERATOR. IF/WHEN THE POWER TO THIS
REFRIGERATOR GOES OUT, THE TENANT MUST BE NOTIFIED IMMEDIATELY.
23. INSTALL TENANT-PROVIDED CEILING-MOUNTED EXAM LIGHT. PROVIDE BLOCKING AND POWER IN
THE CEILING AS REQUIRED. CONFIRM POWER REQUIREMENTS WITH EQUIPMENT PRIOR TO ROUGH-IN.
24. PROVIDE AND INSTALL MILLWORK (SOLID WOOD) WALL-MOUNTED ROBE CLOSET AND COAT ROD. SEE
ELEVATION FOR DETAILS. REFER TO BLOCKING PLAN FOR IN-WALL BLOCKING LOCATION.
25. PROVIDE AND INSTALL BASE AND WALL CABINETS (WHERE INDICATED) AND QUARTZ COUNTERTOP WITH
STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. FAUCET BASIS OF DESIGN FOR ALL AREAS WITH KEYNOTE
25: KOHLER/CRUE SINGLE HANDLE BAR FAUCET/K-22975-VS, SINGLE HOLE.
26. PROVIDE AND INSTALL MOP SINK AT JANITOR'S CLOSET. PLUMBING ENGINEER TO ASSIST IN SPECIFICATION
FOR THE SINK AND ALL APPLICABLE FITTINGS. CONTRACTOR TO PROVIDE AND INSTALL WATER HEATER
SENSOR PAN TO SIT UNDER WATER HEATER. SPEC TO BE RECOMMENDED BY PLUMBING CONTRACTOR.
27. THIS WALL TO BE RESERVED FOR TENANT AV/IT EQUIPMENT. PROVIDE PLYWOOD BLOCKING AT THE WALL TO
MOUNT EQUIPMENT ONTO. SEE BLOCKING PLAN FOR EXACT HEIGHT A.F.F. AND OVERALL SIZE.
28. TENANT SUPPLIED TELEVISION, MOUNTED ON WALL IN THIS LOCATION. PROVIDE WOOD BLOCKING IN THE
WALL. COORDINATE WITH TENANT/OWNER ON EXACT SIZE OF EACH TV. REFER TO BLOCKING PLAN FOR
HEIGHT AND SIZING DETAILS. REFERENCE ELEVATIONS FOR FINAL MOUNTING LOCATION. SEE ELECTRICAL
SHEET FOR REQUIRED POWER AND DATA INFORMATION. COORDINATE ANY HOOKUPS WITH TENANT'S AV/IT
VENDOR.
29. TENANT/OWNER SUPPLIED TELEVISION TO SIT ON FURNITURE PIECE IN THIS APPROXIMATE LOCATION. NO
NEED TO HANG ON WALL. SEE ELECTRICAL SHEET FOR REQUIRED POWER AND DATA INFORMATION.
COORDINATE ANY HOOKUPS WITH TENANT'S AV/IT VENDOR.
30. ELECTRICAL CONTRACTOR TO PROVIDE FLOOR CORE POWER FOR TENANT/OWNER PROVIDED SYSTEMS
FURNITURE WORKSTATIONS. SEE POWER PLAN FOR MORE DETAILS. REFER TO RESPONSIBILITY SCHEDULE ON
THE COVER SHEET OF THIS SET FOR MORE INFORMATION. ALL COORDINATION TO RUN THROUGH
PHANOMEN/design. CONTRACTOR TO CONFIRM FINAL LOCATION WITH FURNITURE PRIOR TO ROUGH-IN.
31. CONTRACTOR TO PROVIDE AND INSTALL A REVERSE OSMOSIS POINT-OF-USE WATER FILTRATION SYSTEM
AND BEVERAGE FAUCET. EACH SYSTEM IS TO BE INSTALLED UNDER THE SINK INSIDE THE BASE CABINETRY
AND RUN TO BEVERAGE FAUCET. BEVERAGE FAUCET BASIS OF DESIGN: BRIZO/61320LF-C-SS (ARC SPOUT).
CONTRACTOR TO SEPARATELY PRICE OUT THE CONNECTION OF THE BREAK ROOM RO SYSTEM INTO THE
NEW TENANT PROVIDED BREAK ROOM REFRIGERATOR.
32. CONTRACTOR TO INSTALL CEMENT BACKER BOARD FULL LENGTH OF WALL AND/OR COLUMN AS
INDICATED FROM FLOOR TO FINISHED CEILING IN PREPARATION FOR THIN BRICK INSTALLATION. THIN BRICK
MATERIAL TO BE PROVIDED AND INSTALLED DIRECTLY BY TENANT. REFERENCE FINISH PLAN KEYNOTE FOR
ADDITIONAL INFORMATION.
33. PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP. MATCH TO TENANT
EXISTING (REFERENCE KEYNOTE #39 BELOW) REFERENCE REFLECTED CEILING PLAN FOR NOTATIONS ON LED
TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS.
34. PROVIDE AND INSTALL 24"D X 30"H WALL MOUNTED SOLID WOOD WORK TOP WITH CONCEALED BRACKETS
FOR SUPPORT AS REQUIRED. REFER TO BLOCKING PLAN ON SHEET A1.3 FOR BLOCKING LOCATIONS.
35. PROVIDE AND INSTALL STAINED WOOD SLIDING DOOR WITH BLACK ROUND KNOB AND METAL BOTTOM
TRACK. INSIDE OF CUBBY SHALL CONTAIN 5 WOOD STAINED SHELVES. QUARTZ LAVATORY COUNTERTOP TO
RUN CONTINUOUSLY UNDER THE BOTTOM OF THE CUBBY DOOR TO FORM THE BOTTOM SHELF.
36. CONTRACTOR TO PROVIDE AND INSTALL GARBAGE DISPOSAL FOR BREAK ROOM SINK.
MANUFACTURER INTENT: IN-SINKERATOR. CONTRACTOR TO SUGGEST SPECIFICATION/SIZE (HEAVY DUTY),
AND TO PROVIDE THE CUT SHEET FOR DESIGNER APPROVAL PRIOR TO ORDERING.
37. CONTRACTOR TO BUILD WALL CUBBIES ALONG THIS LENGTH OF WALL. CUBBIES TO BE CONSTRUCTED FROM
METAL FRAMING, COVERED IN 5
8" DRYWALL ON ALL FLAT SURFACES. ALL INTERIOR SURFACES OF CUBBIES
TO BE PRIMED AND PAINTED. THE ENTIRE BACK WALL OF CUBBIES IS TO BE CLAD IN THIN BRICK. PRICE OUT
CEMENT BACKER BOARD ON THE BACK WALL. APPROXIMATE NUMBER OF CUBBIES TO BE QTY (6), EACH
AROUND 2' SQUARE. FINAL DESIGN TO BE DRAWN OUT IN FORTHCOMING ELEVATION.
38. GENERAL CONTRACTOR TO COORDINATE MOVE FROM CURRENT OFFICE LOCATION AND INSTALL
REQUIREMENTS OF TENANT-PROVIDED AQUARIUM WITH AQUARIUM VENDOR.
39. GENERAL CONTRACTOR TO COORDINATE MOVE FROM CURRENT OFFICE LOCATION AND INSTALL OF
TENANT EXISTING BASE CABINETS (LOCATED IN TENANT'S OLD 'BACK OFFICE' AREA)
40. PROVIDE AND INSTALL TILED SEAT. DETAILS TO FOLLOW.
41. PROVIDE AND INSTALL TEAK WOOD SHELVES AT NICHE.
42. TENANT-PROVIDED REFRIGERATOR. PROVIDE WATER LINE FOR ICE MAKER, AS REQUIRED.
43. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS UNDERCOUNTER
STAINLESS STEEL SINK AND BEVERAGE FAUCET PER KEYNOTE 31. REFERENCE REFLECTED CEILING PLAN FOR
NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS.
44. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS
UNDERCOUNTER STAINLESS STEEL SINK AND HANDS FREE FAUCET. FAUCET BASIS OF DESIGN FOR ALL AREAS
WITH KEYNOTE 44 (EXAM ROOMS) TO BE THE SAME AS FAUCET FOR RESTROOMS. SPEC:
SLOAN/EAF-200-INTEGRATED SIDE MIXER, BRUSHED NICKEL FINISH. REFERENCE REFLECTED CEILING PLAN
FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS.
N
S
W
E
GENERAL CONSTRUCTION NOTES:
1. PROVIDE BLOCKING IN WALLS TO ACCOMODATE ALL CASEWORK AND WALL
MOUNTED EQUIPMENT AND ACCESSORIES. ALL BLOCKING MUST MEET ALL
APPLICABLE FIRE CODES. SEE SHEET A1.3 BLOCKING PLAN FOR LOCATION DETAILS.
2. FINISHED DOOR OPENINGS IN ALL NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT
PERPENDICULAR PARTITION, UNLESS NOTED OTHERWISE.
3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FINISHED FACE OF WALLS
AND CENTERLINE OF COLUMNS.
4. ALL FINISH MILLWORK/CASEWORK IS TO BE COMPLETED IN STIRICT ACCORDANCE
WITH A.W.I. STANDARDS, PREMIUM GRADE. SHOP DRAWINGS SHALL BE SUPPLIED TO
ARCHITECT/DESIGNER PRIOR TO FABRICATION.
5. STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING ELEMENTS SHOWN ARE FOR
REFERENCE ONLHY. VERIFY EACH ELEMENT WITH ENGINEERING DRAWINGS.
NOTIFY ARCHITECT OF ANY CONFLICTS.
6. METAL STUD CONTRACTOR IS RESPONSIBLE FOR GAUGING AND RELATED
ENGINEERING OF METAL STUD FRAMED WALLS UNLESS NOTED OTHERWISE ON
ENGINEERING DRAWINGS.
7. WALL FRAMING, SHEATHING, AND INSULATION EXTEND FROM TOP OF SLAB TIGHT TO
UNDERSIDE OF DECK UNLESS NOTED OTHERWISE VIA WALL TYPE TAG.
8. EXISTING BUILDING ELEMENTS THAT ARE DAMAGED OR MODIFIED DURING
CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO MATCH THEIR EXISTING
ADJACENT CONDITIONS.
AQUARIUM
MAINT.
302
BREAK
ROOM
318
LARGE CONF
ROOM
316
MEDICAL
STORAGE
334
BLOOD
DRAW
303
M. PRIDDY
OFFICE 4
338
J. RIZZUTO
OFFICE 5
339
EXAM 1
306A
EX 1
PATIENT RR
306B
EXAM 2
307A
EX 2
PATIENT RR
307B
GENERAL
STORAGE
332
OFFICE 1
335
OFFICE 3
337
PHARMACY
& SAMPLES
304
OFFICE 7
330
MOLE MAPPING
(PHOTO FINDER)
329
STORAGE
305
JANITOR
328
EXAM 3
308A
EX 3
PATIENT RR
308B
LAB
322
PROCEDURE
ROOM
317
OFFICE 8
327
UNISEX
RESTROOM
319 EXAM 10
PEDIATRIC
315A
EX PED
PATIENT RR
315B
EX 4
PATIENT RR
309B
OFFICE 9
326
OFFICE 10
325
EXAM 5
310A
PROCEDURE &
BLOOD DRAW
323
SHOWER
ROOM
320
EXAM 9
314A
EX 9
PATIENT RR
314B
EXAM 8
313A
EX 8
PATIENT RR
313B
EXAM 4
309A
EX 5
PATIENT RR
310B
EX 6
PATIENT RR
311B
EX 7
PATIENT RR
312B
EXAM 6
311A
EXAM 7
312A
OFFICE 2
336
RECEPTION
300
WAITING LOUNGE
301
SOILED
LINENS
321
STORAGE
324
BACK HALL
333
OPEN
OFFICE
340
HALLWAY
341
HALLWAY
342
HALLWAY
343
HALLWAY
344
HALLWAY
345
HALLWAY
346
1
305
304
306A
306B
304
302
331
340A
300
307A
307B 308B
308A
329
328
340B
330
332B
309B
309A
327
326
310A
310B
311A
311B
312A
312B 313B
313A
323
324
314A
314B
322
321
320
319
325
315A
315B
316
317
335
336
337
338
339
346B
318C
318B
318A
346A
347
332A 334
333
1
1
1
1
1
2
1
1
1
IT
W3 W4 W5 W6
W1 W2
W7
W8
W10 W9
W11
W13
W12
5
6
1
7
W14
W15
9
XX.X
X
10
11
12
13
14
15
16
17
19
19
20
22 20 21
23
24
39
20
25
26
18
20
27
43
43
28
28
28
28 28
28
29 29 29
29
29
28
28
30
30
EXISTING
STAIR 2
NIC
DN
DN
EXISTING
STAIR 1
NIC
31
31
31
32
32 32 32 32
32
ELEC. ROOM
EXIST.
NIC
33
TYP.
TYP.
34
34
TYP.
33
8
35
22
36
37
4
TYP.
4
TYP.
44
1
38
TYP.
24
TYP.
32
32
32
32
3
40
41
42
TYP.
TYP.
32
32
1
1
1
1
REFERENCE SHEET A1.6 FOR ENLARGED 0 5 10 20 40
RESTROOM PLANS
1
1
1 1