Loading...
HomeMy WebLinkAboutA1.1 Annotated FLoor PlanAQUARIUM DW MF MF MIKE OFFICE 6 331 Certified By: Scale: Date: Checked By: Drawn By: Job Number: Drawing Number: Drawing Name: CARMEL, IN 46032 01.22.2021 www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202 317.439.4355 (t) PRIORITY PHYSICIANS ...creating profitable environments... Revisions: 12174 N. MERIDIAN SUITE 300 1/8"=1'-0" 1 ANNOTATED FLOOR PLAN A S NOTED BSH LOE ANNOTATED FLOOR PLAN A1.1 PERMIT SET 01.22.2021 # FLOOR PLAN KEYNOTES: 1. ALIGN FINISHED FACES. 2. TYPICAL: ALIGN NEW WALL WITH CENTER OF WINDOW MULLION. SEE 6/A1.2 FOR DETAILS. 3. PROVIDE ALLOWANCE FOR NEW CUSTOM CORNER WOOD BOOKCASE. ADDITIONAL DETAILS TO FOLLOW. 4. PAINT ALL EXPOSED EXISTING COLUMNS 'PT-X', UNLESS OTHERWISE NOTED. 5. CONTRACTOR TO PROVIDE AND INSTALL CEMENT BACKER BOARD FOR WALL TILE INSTALLATION, FROM FLOOR TO CEILING AT ALL WALLS INSIDE WALK-IN SHOWER. 6. CONTRACTOR TO PROVIDE AND INSTALL GREEN BOARD ON WALLS, FROM FLOOR TO CEILING AT ALL WALLS INSIDE THE AQUARIUM MAINTENANCE ROOM. 7. SMARTPERGOLA ELECTRICAL CONTROL BOX TO BE INSTALLED THIS APPROXIMATE LOCATION. CENTER OF BOX TO BE MOUNTED AT 72" A.F.F. ELECTRICAL ENGINEER TO COORDINATE DIRECTLY WITH SMART PERGOLA IN VERIFYING ALL POWER REQUIREMENTS. PROVIDE BLOCKING IN WALL TO ACCOMMODATE SIZE OF CONTROL BOX. 8. CONTRACTOR TO PROVIDE AND INSTALL FLOOR DRAIN IN CENTER OF AQUARIUM MAINT. ROOM 302, SLOPE FLOOR TO DRAIN AS REQUIRED. 9. PROVIDE ALLOWANCE FOR NEW CUSTOM RECEPTION DESK. ANTICIPATED FINISHES: WOOD AND TILE FACE, METAL TOE KICK AND TRIM. PROVIDE $90/ SF INSTALLED QUARTZ TRANSACTION TOP AND WORK SURFACE ALLOWANCE. REFERENCE ENLARGED PLAN FOR MORE DETAILS. 10. CONTRACTOR TO PROVIDE AND INSTALL FLOOR DRAIN IN THE SHOWER ROOM, SLOPE FLOOR TO DRAIN. REFER TO PLUMBING PLANS FOR MORE DETAILS. 11. CONTRACTOR TO INSTALL PHANOMEN PROVIDED 'LIVING WALL' (GREEN WALL). NO PLUMBING OR ELECTRICAL NEEDED. CONTACT PHANOMEN FOR DETAILS AND INSTALLATION INSTRUCTIONS. 12. CONTRACTOR TO COORDINATE TRANSFER OF EXISTING CONFERENCE TABLE AND CASEWORK W/ SINK FROM THE CURRENT PRIORITY OFFICE TO NEW LOCATION AS SHOWN. CONTRACTOR TO TAKE EXTREME CARE NOT TO DAMAGE ANY EXISTING MATERIALS WHILE REMOVING ITEMS FROM WALLS AND FLOOR. CAREFULLY UNHOOK AND CAP ANY ELECTRICAL, PLUMBING, AND/OR AV/IT ITEMS AT THEIR SOURCES BEFORE MOVING. 13. PROVIDE AND INSTALL FULL-HEIGHT WOOD PANTRY, SPECS T.B.D. SEE ELEVATION FOR DETAILS. 14. CONTRACTOR TO PROVIDE AND INSTALL BREAK ROOM BASE CABINETS W/ GRANITE COUNTERTOP STAINLESS STEEL UNDERMOUNT DOUBLE SINK, SPEC. T.B.D. KITCHEN FAUCET BASIS OF DESIGN: KOHLER/CRUE/TOUCHLESS PULL-DOWN SINGLE-HANDLE KITCHEN FAUCET IN VIBRANT STAINLESS (K-22974-VS). SEE ELEVATION FOR DETAILS. 15. CONTRACTOR TO PROVIDE AND INSTALL METAL AND GLASS UPPER SHELVING. PROVIDE BLOCKING IN THE CEILING FOR SUPPORT AS REQUIRED. SEE ELEVATION FOR DETAILS. 16. CONTRACTOR TO PROVIDE AND INSTALL BREAK ROOM ISLAND BASE CABINET AND QUARTZ COUNTERTOP. SEE ELEVATION FOR DETAILS. REFER TO ELECTRICAL PLANS FOR OUTLET LOCATIONS AND HEIGHTS. 17. CONTRACTOR TO INSTALL NEW TENANT PROVIDED ELECTRIC STOVETOP, RANGE HOOD, REFRIGERATOR, AND DISHWASHER. SEE MEP PLANS FOR POWER REQUIREMENTS AND REFERENCE FINAL ELEVATIONS FOR ROUGH-IN LOCATIONS. CUT SHEETS SHALL BE REQUESTED DIRECTLY FROM TENANT. 18. EXISTING TENANT PROVIDED COPIER/PRINTER. REQUIRED DEDICATED OUTLET. SEE POWER PLANS. 19. PROVIDE AND INSTALL BASE CABINETS AND QUARTZ COUNTERTOP, MATCH STYLE TO TENANT EXISTING (REFERENCE KEYNOTE #39 BELOW). SEE ELEVATION FOR DETAILS. 20. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. BASIS OF DESIGN FOR ALL AREAS WITH KEYNOTE 20: KOHLER/CRUE SINGLE HANDLE BAR FAUCET/K-22975-VS, SINGLE HOLE. REFERENCE REFLECTED CEILING PLAN FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS. 21. EXISTING TENANT REFRIGERATOR RELOCATED FROM FORMER OFFICE. COORDINATE POWER REQUIREMENTS WITH TENANT. TIE TO ALARM SYSTEM. REFER TO MEP PLANS FOR MORE INFORMATION. 22. EXISTING VACCINE REFRIGERATOR/FREEZER. REFER TO POWER PLANS FOR MORE INFORMATION. DEDICATED OUTLET MUST BE TIED INTO ALARM SYSTEM/GENERATOR. IF/WHEN THE POWER TO THIS REFRIGERATOR GOES OUT, THE TENANT MUST BE NOTIFIED IMMEDIATELY. 23. INSTALL TENANT-PROVIDED CEILING-MOUNTED EXAM LIGHT. PROVIDE BLOCKING AND POWER IN THE CEILING AS REQUIRED. CONFIRM POWER REQUIREMENTS WITH EQUIPMENT PRIOR TO ROUGH-IN. 24. PROVIDE AND INSTALL MILLWORK (SOLID WOOD) WALL-MOUNTED ROBE CLOSET AND COAT ROD. SEE ELEVATION FOR DETAILS. REFER TO BLOCKING PLAN FOR IN-WALL BLOCKING LOCATION. 25. PROVIDE AND INSTALL BASE AND WALL CABINETS (WHERE INDICATED) AND QUARTZ COUNTERTOP WITH STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. FAUCET BASIS OF DESIGN FOR ALL AREAS WITH KEYNOTE 25: KOHLER/CRUE SINGLE HANDLE BAR FAUCET/K-22975-VS, SINGLE HOLE. 26. PROVIDE AND INSTALL MOP SINK AT JANITOR'S CLOSET. PLUMBING ENGINEER TO ASSIST IN SPECIFICATION FOR THE SINK AND ALL APPLICABLE FITTINGS. CONTRACTOR TO PROVIDE AND INSTALL WATER HEATER SENSOR PAN TO SIT UNDER WATER HEATER. SPEC TO BE RECOMMENDED BY PLUMBING CONTRACTOR. 27. THIS WALL TO BE RESERVED FOR TENANT AV/IT EQUIPMENT. PROVIDE PLYWOOD BLOCKING AT THE WALL TO MOUNT EQUIPMENT ONTO. SEE BLOCKING PLAN FOR EXACT HEIGHT A.F.F. AND OVERALL SIZE. 28. TENANT SUPPLIED TELEVISION, MOUNTED ON WALL IN THIS LOCATION. PROVIDE WOOD BLOCKING IN THE WALL. COORDINATE WITH TENANT/OWNER ON EXACT SIZE OF EACH TV. REFER TO BLOCKING PLAN FOR HEIGHT AND SIZING DETAILS. REFERENCE ELEVATIONS FOR FINAL MOUNTING LOCATION. SEE ELECTRICAL SHEET FOR REQUIRED POWER AND DATA INFORMATION. COORDINATE ANY HOOKUPS WITH TENANT'S AV/IT VENDOR. 29. TENANT/OWNER SUPPLIED TELEVISION TO SIT ON FURNITURE PIECE IN THIS APPROXIMATE LOCATION. NO NEED TO HANG ON WALL. SEE ELECTRICAL SHEET FOR REQUIRED POWER AND DATA INFORMATION. COORDINATE ANY HOOKUPS WITH TENANT'S AV/IT VENDOR. 30. ELECTRICAL CONTRACTOR TO PROVIDE FLOOR CORE POWER FOR TENANT/OWNER PROVIDED SYSTEMS FURNITURE WORKSTATIONS. SEE POWER PLAN FOR MORE DETAILS. REFER TO RESPONSIBILITY SCHEDULE ON THE COVER SHEET OF THIS SET FOR MORE INFORMATION. ALL COORDINATION TO RUN THROUGH PHANOMEN/design. CONTRACTOR TO CONFIRM FINAL LOCATION WITH FURNITURE PRIOR TO ROUGH-IN. 31. CONTRACTOR TO PROVIDE AND INSTALL A REVERSE OSMOSIS POINT-OF-USE WATER FILTRATION SYSTEM AND BEVERAGE FAUCET. EACH SYSTEM IS TO BE INSTALLED UNDER THE SINK INSIDE THE BASE CABINETRY AND RUN TO BEVERAGE FAUCET. BEVERAGE FAUCET BASIS OF DESIGN: BRIZO/61320LF-C-SS (ARC SPOUT). CONTRACTOR TO SEPARATELY PRICE OUT THE CONNECTION OF THE BREAK ROOM RO SYSTEM INTO THE NEW TENANT PROVIDED BREAK ROOM REFRIGERATOR. 32. CONTRACTOR TO INSTALL CEMENT BACKER BOARD FULL LENGTH OF WALL AND/OR COLUMN AS INDICATED FROM FLOOR TO FINISHED CEILING IN PREPARATION FOR THIN BRICK INSTALLATION. THIN BRICK MATERIAL TO BE PROVIDED AND INSTALLED DIRECTLY BY TENANT. REFERENCE FINISH PLAN KEYNOTE FOR ADDITIONAL INFORMATION. 33. PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP. MATCH TO TENANT EXISTING (REFERENCE KEYNOTE #39 BELOW) REFERENCE REFLECTED CEILING PLAN FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS. 34. PROVIDE AND INSTALL 24"D X 30"H WALL MOUNTED SOLID WOOD WORK TOP WITH CONCEALED BRACKETS FOR SUPPORT AS REQUIRED. REFER TO BLOCKING PLAN ON SHEET A1.3 FOR BLOCKING LOCATIONS. 35. PROVIDE AND INSTALL STAINED WOOD SLIDING DOOR WITH BLACK ROUND KNOB AND METAL BOTTOM TRACK. INSIDE OF CUBBY SHALL CONTAIN 5 WOOD STAINED SHELVES. QUARTZ LAVATORY COUNTERTOP TO RUN CONTINUOUSLY UNDER THE BOTTOM OF THE CUBBY DOOR TO FORM THE BOTTOM SHELF. 36. CONTRACTOR TO PROVIDE AND INSTALL GARBAGE DISPOSAL FOR BREAK ROOM SINK. MANUFACTURER INTENT: IN-SINKERATOR. CONTRACTOR TO SUGGEST SPECIFICATION/SIZE (HEAVY DUTY), AND TO PROVIDE THE CUT SHEET FOR DESIGNER APPROVAL PRIOR TO ORDERING. 37. CONTRACTOR TO BUILD WALL CUBBIES ALONG THIS LENGTH OF WALL. CUBBIES TO BE CONSTRUCTED FROM METAL FRAMING, COVERED IN 5 8" DRYWALL ON ALL FLAT SURFACES. ALL INTERIOR SURFACES OF CUBBIES TO BE PRIMED AND PAINTED. THE ENTIRE BACK WALL OF CUBBIES IS TO BE CLAD IN THIN BRICK. PRICE OUT CEMENT BACKER BOARD ON THE BACK WALL. APPROXIMATE NUMBER OF CUBBIES TO BE QTY (6), EACH AROUND 2' SQUARE. FINAL DESIGN TO BE DRAWN OUT IN FORTHCOMING ELEVATION. 38. GENERAL CONTRACTOR TO COORDINATE MOVE FROM CURRENT OFFICE LOCATION AND INSTALL REQUIREMENTS OF TENANT-PROVIDED AQUARIUM WITH AQUARIUM VENDOR. 39. GENERAL CONTRACTOR TO COORDINATE MOVE FROM CURRENT OFFICE LOCATION AND INSTALL OF TENANT EXISTING BASE CABINETS (LOCATED IN TENANT'S OLD 'BACK OFFICE' AREA) 40. PROVIDE AND INSTALL TILED SEAT. DETAILS TO FOLLOW. 41. PROVIDE AND INSTALL TEAK WOOD SHELVES AT NICHE. 42. TENANT-PROVIDED REFRIGERATOR. PROVIDE WATER LINE FOR ICE MAKER, AS REQUIRED. 43. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS UNDERCOUNTER STAINLESS STEEL SINK AND BEVERAGE FAUCET PER KEYNOTE 31. REFERENCE REFLECTED CEILING PLAN FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS. 44. TYPICAL: PROVIDE AND INSTALL BASE CABINETS, UPPER CABINETS, QUARTZ COUNTERTOP(S) AS WELL AS UNDERCOUNTER STAINLESS STEEL SINK AND HANDS FREE FAUCET. FAUCET BASIS OF DESIGN FOR ALL AREAS WITH KEYNOTE 44 (EXAM ROOMS) TO BE THE SAME AS FAUCET FOR RESTROOMS. SPEC: SLOAN/EAF-200-INTEGRATED SIDE MIXER, BRUSHED NICKEL FINISH. REFERENCE REFLECTED CEILING PLAN FOR NOTATIONS ON LED TAPE LIGHT(S) REQUIRED. REFERENCE ELEVATIONS FOR DETAILS. N S W E GENERAL CONSTRUCTION NOTES: 1. PROVIDE BLOCKING IN WALLS TO ACCOMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT AND ACCESSORIES. ALL BLOCKING MUST MEET ALL APPLICABLE FIRE CODES. SEE SHEET A1.3 BLOCKING PLAN FOR LOCATION DETAILS. 2. FINISHED DOOR OPENINGS IN ALL NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR PARTITION, UNLESS NOTED OTHERWISE. 3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FINISHED FACE OF WALLS AND CENTERLINE OF COLUMNS. 4. ALL FINISH MILLWORK/CASEWORK IS TO BE COMPLETED IN STIRICT ACCORDANCE WITH A.W.I. STANDARDS, PREMIUM GRADE. SHOP DRAWINGS SHALL BE SUPPLIED TO ARCHITECT/DESIGNER PRIOR TO FABRICATION. 5. STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING ELEMENTS SHOWN ARE FOR REFERENCE ONLHY. VERIFY EACH ELEMENT WITH ENGINEERING DRAWINGS. NOTIFY ARCHITECT OF ANY CONFLICTS. 6. METAL STUD CONTRACTOR IS RESPONSIBLE FOR GAUGING AND RELATED ENGINEERING OF METAL STUD FRAMED WALLS UNLESS NOTED OTHERWISE ON ENGINEERING DRAWINGS. 7. WALL FRAMING, SHEATHING, AND INSULATION EXTEND FROM TOP OF SLAB TIGHT TO UNDERSIDE OF DECK UNLESS NOTED OTHERWISE VIA WALL TYPE TAG. 8. EXISTING BUILDING ELEMENTS THAT ARE DAMAGED OR MODIFIED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO MATCH THEIR EXISTING ADJACENT CONDITIONS. AQUARIUM MAINT. 302 BREAK ROOM 318 LARGE CONF ROOM 316 MEDICAL STORAGE 334 BLOOD DRAW 303 M. PRIDDY OFFICE 4 338 J. RIZZUTO OFFICE 5 339 EXAM 1 306A EX 1 PATIENT RR 306B EXAM 2 307A EX 2 PATIENT RR 307B GENERAL STORAGE 332 OFFICE 1 335 OFFICE 3 337 PHARMACY & SAMPLES 304 OFFICE 7 330 MOLE MAPPING (PHOTO FINDER) 329 STORAGE 305 JANITOR 328 EXAM 3 308A EX 3 PATIENT RR 308B LAB 322 PROCEDURE ROOM 317 OFFICE 8 327 UNISEX RESTROOM 319 EXAM 10 PEDIATRIC 315A EX PED PATIENT RR 315B EX 4 PATIENT RR 309B OFFICE 9 326 OFFICE 10 325 EXAM 5 310A PROCEDURE & BLOOD DRAW 323 SHOWER ROOM 320 EXAM 9 314A EX 9 PATIENT RR 314B EXAM 8 313A EX 8 PATIENT RR 313B EXAM 4 309A EX 5 PATIENT RR 310B EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B EXAM 6 311A EXAM 7 312A OFFICE 2 336 RECEPTION 300 WAITING LOUNGE 301 SOILED LINENS 321 STORAGE 324 BACK HALL 333 OPEN OFFICE 340 HALLWAY 341 HALLWAY 342 HALLWAY 343 HALLWAY 344 HALLWAY 345 HALLWAY 346 1 305 304 306A 306B 304 302 331 340A 300 307A 307B 308B 308A 329 328 340B 330 332B 309B 309A 327 326 310A 310B 311A 311B 312A 312B 313B 313A 323 324 314A 314B 322 321 320 319 325 315A 315B 316 317 335 336 337 338 339 346B 318C 318B 318A 346A 347 332A 334 333 1 1 1 1 1 2 1 1 1 IT W3 W4 W5 W6 W1 W2 W7 W8 W10 W9 W11 W13 W12 5 6 1 7 W14 W15 9 XX.X X 10 11 12 13 14 15 16 17 19 19 20 22 20 21 23 24 39 20 25 26 18 20 27 43 43 28 28 28 28 28 28 29 29 29 29 29 28 28 30 30 EXISTING STAIR 2 NIC DN DN EXISTING STAIR 1 NIC 31 31 31 32 32 32 32 32 32 ELEC. ROOM EXIST. NIC 33 TYP. TYP. 34 34 TYP. 33 8 35 22 36 37 4 TYP. 4 TYP. 44 1 38 TYP. 24 TYP. 32 32 32 32 3 40 41 42 TYP. TYP. 32 32 1 1 1 1 REFERENCE SHEET A1.6 FOR ENLARGED 0 5 10 20 40 RESTROOM PLANS 1 1 1 1