Loading...
HomeMy WebLinkAboutA1.4 Reflected Ceiling Plan and Lighting ScheduleP1 P3 P4 P5 L1 L1 11' - 0" PT-X 11' - 0" PT-X 9' - 6" ACT-X 10' - 0" PT-X 9' - 6" ACT-X EXT. DECK PT-X EXT. DECK PT-X 9' - 6" ACT-X 9' - 0" ACT-X 9' - 6" ACT-X 9' - 6" PT-X 10' - 0" PT-X N.I.C. N.I.C. 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" 9' - 6" ACT-X ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" 9' - 6" ACT-X ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 9' - 6" ACT-X 10' - 0" ACT-X EXT. DECK EXT. DECK EXT. DECK PT-X PT-X 10' - 0" PT-X 10' - 0" PT-X EXT. DECK EXT. DECK 9' - 6" ACT-X 10' - 0" PT-X 10' - 10" WD-X 9' - 0" ACT-X 9' - 0" ACT-X 9' - 0" ACT-X 9' - 0" PT-X 10' - 0" PT-X 13' - 0" PT-X 8'- 0" PT-X 8' - 0" PT-X 9' - 10" PT-X 8' - 0" PT-X L1 P6 P6 P6 L2 8' - 0" PT-X R2 9' - 0" PT-X 9' - 0" PT-X 9' - 0" PT-X 8'- 6" PT-X 8' - 0" PT-X 1 AQUARIUM MAINT. 302 AQUARIUM MIKE OFFICE 6 331 BREAK ROOM 318 CONFERENCE ROOM 316 MEDICAL STORAGE 334 BLOOD DRAW 303 M. PRIDDY OFFICE 4 338 J. RIZZUTO OFFICE 5 339 EXAM 1 306A EX 1 PATIENT RR 306B EXAM 2 307A EX 2 PATIENT RR 307B GENERAL STORAGE 332 OFFICE 1 335 OFFICE 3 337 PHARMACY & SAMPLES 304 OFFICE 7 330 MOLE MAPPING (PHOTO FINDER) 329 STORAGE 305 JANITOR 328 EXAM 3 308A EX 3 PATIENT RR 308B LAB 322 PROCEDURE ROOM 317 OFFICE 8 327 UNISEX RESTROOM 319 EXAM 10 PEDIATRIC 315A EX PED PATIENT RR 315B EX 4 PATIENT RR 309B OFFICE 9 326 OFFICE 10 325 EXAM 5 310A PROCEDURE & BLOOD DRAW 323 SHOWER ROOM 320 EXAM 9 314A EX 9 PATIENT RR 314B EXAM 8 313A EX 8 PATIENT RR EXAM 4 313B 309A EX 5 PATIENT RR 310B EX 6 PATIENT RR 311B EX 7 PATIENT RR 312B EXAM 6 311A EXAM 7 312A OFFICE 2 336 RECEPTION 300 WAITING LOUNGE 301 SOILED LINENS 321 STORAGE 324 BACK HALL 333 OPEN OFFICE 340 HALLWAY 341 HALLWAY 342 HALLWAY 343 HALLWAY 344 HALLWAY 345 HALLWAY 346 EXISTING STAIR 2 NIC EXISTING STAIR 1 NIC DN DN ELEC. ROOM (EXIST.) NIC 6 9' - 0" PT-X 9' - 0" PT-X 8' - 0" PT-X 9' - 0" PT-X R3 R3 R3 9' - 0" ACT-X R3 9' - 6" PT-X 8'- 0" PT-X 7 9 11'-0" WD-X W2 12 R4 R4 R4 R4 R7 9' - 0" PT-X EXT. DECK PT-X W3 W3 R3 13 11 11 10 10 13 13 13 13 13 13 13 13 13 13 9' - 0" ACT-X L1 x 4 P8 P8 T1 T1 13 13 T2 EXT. DECK PT-X P8 W4 W5 R5 R3 W1 R3 9' - 6" PT-X 10' - 0" PT-X P9 9' - 6" ACT-X EXT. DECK PT-X PT-X PT-X PT-X 9' - 6" ACT-X P8 P7 10' - 0" PT-X EXT. DECK PT-X EXT. DECK PT-X EXT. DECK PT-X L3 10' - 0" PT-X 15 15 16 P8 P8 P8 R3 R2 R1 R1 R1 R1 R1 L1 R1 S1 R1 R2 R1 R1 R1 R1 R1 F1 R2 R2 P6 R2 F1 R1 R2 P6 P6 R1 R1 R1 W4 R4 R2 R2 R2 R2 R2 R2 R3 R1 R1 R2 P8 P8 P8 L3 L3 L3 R1 W1 R1 L3 L3 R1 F1 F1 F1 F1 F1 F1 F1 F1 F1 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 P8 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 T1 T1 T1 T1 T1 T1 T1 T1 T1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R2 R1 R1 R1 R2 R2 R2 R2 R3 R3 R3 R3 R3 R3 R1 R1 R4 R1 R1 R1 P6 P6 P6 R1 P6 P6 P6 P6 R1 R1 R1 R1 R2 R1 R3 R2 R2 R2 R1 R2 R2 R1 R1 R1 R1 R1 R2 R2 R2 R3 R1 R3 R1 R1 R1 R2 R2 R1 R2 R1 R1 R1 R2 R2 R1 R2 R1 R1 R1 R1 R1 R1 R2 R2 R3 R1 R3 R1 R2 R7 R7 R7 R7 P7 P7 P7 P7 P7 P7 P7 P7 P7 P7 P7 P7 W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 R4 R3 R4 R4 R4 R2 R2 R1 R1 R1 R3 R1 R1 R1 R1 R1 R1 R2 R3 R1 R4 R1 R1 R2 R3 R3 R1 R2 R2 R1 R1 R1 R1 R2 R1 R1 R2 R2 P2 R1 R1 R1 R1 R1 R1 R1 R1 R1 R2 R2 R1 R1 R1 R1 R4 R1 R1 W1 R1 R1 R2 R2 R1 R1 R1 R3 R3 R1 R1 R1 R1 R7 R7 R7 R7 R7 16 16 16 16 16 16 L3 L3 L3 L3 F1 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 11'- 0" PT-X 17 11'- 0" PT-X 11'- 0" PT-X 18 18 18 18 18 18 18 18 18 18 18 18 18 18 P5 L1 P6 W1 L3 R1 R2 R2 F1 R1 R2 L3 L3 L3 R1 W1 R1 L3 L3 R1 R2 R4 L3 L3 L3 L3 Certified By: Scale: Date: Checked By: Drawn By: Job Number: Drawing Number: Drawing Name: CARMEL, IN 46032 01.22.2021 www.phanomen.com 934 Fort Wayne Ave. - Indianapolis, IN 46202 317.439.4355 (t) PRIORITY PHYSICIANS ...creating profitable environments... Revisions: 12174 N. MERIDIAN SUITE 300 1/8"=1'-0" 1 REFLECTED CEILING PLAN A S NOTED BSH LOE REFLECTED CEILING PLAN & LIGHTING SCHEDULE A1.4 PERMIT SET 01.22.2021 # REFLECTED CEILING PLAN KEYNOTES: GENERAL REFLECTED CEILING NOTES: 1. CENTER LIGHT FIXTURE OVER LENGTH OF RECEPTION DESK TRANSACTION TOP. 2. (NOT USED.) 3. (NOT USED.) 4. CONTRACTOR TO PROVIDE AND INSTALL WOODEN 11X17" SUSPENDED PLATFORM FOR HVAC CONDENSATE PUMP AS REQUIRED. 5. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING AND/OR ADDITIONAL SUPPORT IN THE STRUCTURE OF CEILING TO ACCOMMODATE FOR THE ADDITIONAL WEIGHT OF PHANOMEN PROVIDED WINDOW COVERINGS/DRAPERY. 6. CONTRACTOR TO PROVIDE AND INSTALL L1 LED ROPE LIGHT AROUND RANGE HOOD. REFERENCE DETAIL DRAWINGS FOR MORE INFORMATION. 7. CONTRACTOR TO PROVIDE AND INSTALL WOOD SLAT ACOUSTICAL PANEL MATERIAL AS AN APPLIED FINISH OVER THE TOP OF THE PAINTED DRYWALL CEILING. MANUFACTURER: ACOUSTICAL ART CONCEPTS/AKUPANEL 3X1 VN520. COORDINATE FINAL SPECIFICATION WITH DESIGNER PRIOR TO ORDERING. SEE CEILING DETAIL SHEET FOR MORE INFORMATION. 8. CONTRACTOR TO PROVIDE AND INSTALL 'L3' FIXTURE IN 1" GAP IN BETWEEN ACOUSTICAL WOOD SLAT MATERIAL MENTIONED IN KEYNOTE 7 ON THIS SHEET. ALL AREAS OF 'L3' SHOWN SHALL INSTALL ON CEILING AND DOWN WALL (90 DEGREES), EXCEPT AS OTHERWISE NOTED ON KEYNOTE #20 OF THIS SHEET. 9. DRYWALL CEILING OVER THE SHOWER TO BE ARCHED. EXACT RADIUS TO BE DETERMINED. CONTRACTOR TO VERIFY FINAL DESIGN AND RADIUS WITH DESIGNER PRIOR TO FRAMING. 10. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT AT MILLWORK TOE KICK. REFERENCE ELEVATIONS FOR DETAILS. A. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE ORDER OF MATERIALS AND COMMENCEMENT OF ANY WORK. B. CEILINGS IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, AND STATE AND LOCAL BUILDING CODES. C. ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES. D. ALL GYP. BOARD WALLS, CEILINGS AND BULKHEADS, SHALL BE A SMOOTH LEVEL 4 FINISH AS OUTLINED IN GYPSUM ASSOCIATION GA-214. E. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. CONFIRM ALL NEW SWITCH LOCATIONS WITH OWNER PRIOR TO ROUGH-IN. F. ALL MATERIALS EXPOSED WITHIN THE PLENUM MUST BE NONCOMBUSTIBLE OR SHALL COMPLY WITH LABELING, FLAME AND SMOKE DEVELOPMENT RATINGS AS SPECIFIED IN THE CURRENT EDITION OF THE INDIANA MECHANICAL CODE. G. MEANS OF EGRESS ILLUMINATION SHALL BE LOCATED IN ACCORDANCE WITH SECTION G. 1006, IBC (675 IAC 13-2.5). H. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A J-BOX OR OUTLET AS WELL AS ANY ASSOCIATED WIRING AT LOCATIONS NOTED IN PLAN FOR DECORATIVE LED ROPE LIGHTING AT CASEWORK NOTED. ALL DECORATIVE LED ROPE LIGHTING MATERIAL AND CONNECTIONS WILL BE CONSIDERED A PART OF THE FINAL FINISH BUILD-OUT OF THE TENANT SUITE. I. CONTRACTOR TO INSTALL RECESSED LIGHT FIXTURES IN CENTER OF CEILING TILES. TYPICAL ALL LOCATIONS AND LIGHT FIXTURE TYPES, UNLESS DRAWN OTHERWISE. J. UNLESS NOTED OTHERWISE, ALL UNLABELED/UNHATCHED CEILINGS WILL BE ASSUMED DRYWALL CEILING. N S W E Above: height indication above finished floor Mounting height to center above finished floor NOTE: FIXTURES BELOW ARE TO BE PROVIDED AND INSTALLED BY CONTRACTOR CONTACT SPECIFIED LIGHTING SYSTEMS FOR PRICING (TRACI ASHCRAFT AT (317) 340-9423, TASHCRAFT@SLSINDIANA.COM ) NOTE: FIXTURES BELOW ARE TO BE PROVIDED BY PHANOMEN/design AND INSTALLED BY THE CONTRACTOR X'-X" A.F.F. XX-X +XX R1: New recessed light fixture: Focal Point Lighting/ID + 6" round fixed LED downlight, Model # FLC6D-RO-1500L-120-L11-T_LC6-RO-1500L-27K-DN-CD-NP, 2700K lamping. Lumen output spec 1500, 17 watts. 90 CRI. 0-10V (1%) dimming. Clear diffuse, white housing. R3: New recessed 1x4 troffer light fixture: Cooper Lighting Solutions/Metalux/ Model #: ATW-14RLN-LD5-31-UNV-L92765. 90 CRI, 2700k-6500k white tuning, 30 watts. W2A White Tuning driver required. 2 channel (Intensity and CCT) control. ACT-2: New 2x2 Suspended Ceiling System. See finish legend for spec. REFLECTED CEILING PLAN LEGEND EM1: New Emergency Light: Cooper Lighting/Apel Series. Two 3.6 V LED heads, in white finish (APELH2) EM2: Evenlite/Sovereign - LED Edgelit Exit Sign. Flat Trim for recessed ceiling mount. Clear finish with red 6" letters. Mirror finish for all double-sided instances. Single Pole Switch Dimmer Switch (Install LED compatible dimmer where applicable) 3-Way Switch Occupancy Sensor (at ceiling): provided and installed by contractor to meet all requirements of the 2010 Indiana Energy Conservation Code Switching Intent Night Light Fixture S D 3 OP NL Below: ceiling finish EM3: Evenlite/Sovereign - LED Edgelit Exit Sign. Flat Trim for recessed ceiling mount. Clear finish with red 6" letters, with directional arrow(s). Mirror finish for all double-sided instances. P4: New pendant light fixture: TBD, 600 watts. Confirm final mounting height with designer prior to rough-in. P3: New pendant light fixture: TBD, 100 watts. Confirm final mounting height with designer prior to rough-in. P1: New chandelier light fixture: TBD, 600 watts. Confirm final mounting height with designer prior to rough-in. P5: New pendant light fixture: TBD, 100 watts. Confirm final mounting height with designer prior to rough-in. P6: New pendant light fixture over exam restroom vanities: TBD, 13 watts, Confirm final mounting height with designer prior to rough-in. P8: New LED suspended can light fixture. Focal Point Lighting/ID + 4.5" Cylinder FLCY4-2700K-90CRI-IC-SC-L11-BXX (VERIFY WITH MOUNTING HEIGHT) -DNT-VWFL-CD-XX (VERIFY FINAL COLOR WITH DESIGNER). 2700K, 90 CRI, 1% dimmable, 250 watt, Swivel stem mount bottom of fixture 9'-0" AFF R4: New recessed Linear LED perimeter light. Focal Point Lighting/Seem 2. (4" Regress) FSM2PR-ALH-FL4-250LF-2700K-90CRI-1C-UNV-L11-XF-WH. Dimmable,19 watts. Individual lengths needed. Contractor to verify quantity to fill entire length of cove, connectors, and transformer requirements prior to order. R5: New recessed Linear LED perimeter light. Focal Point Lighting/Seem 2. (2.5" Regress) FSM2PR-ALH-FL2-250LF-2700K-90CRI-1C-UNV-L11-XF-WH. Dimmable, 19 watts. Individual lengths needed. Contractor to verify quantity to fill entire length of cove, connectors, and transformer requirements prior to order. T1: New LED Suspended Track Light 4' track length with qty (2) LED heads per location. 9 watt/1021 lumens per head. 2700K, 90 CRI, 0-10V dimmable. Contech Lighting/CTL-9051-F-2C-D-B. Contractor to mount Contech LT Single Circuit Line Voltage Track to unistrut at 10'-6" AFF, Bottom of track head at approx. 10'-0" AFF. R2: New recessed light fixture: Focal Point Lighting/ID + 4.5" round adjustable LED downlight, Model# FLCS4-RO-1500L-27K-FL-L11-T_LCS4-RD-AA-CD-NP, 2700K lamping, 1500 lm, 25 watts, 90 CRI. 0-10V(1%) dimming. Clear diffuser, white housing. L1: New Linear LED Tape Light: Luminii/LineLED LL Serires. LL54 (354 lumens/ft), 2700K lamping, 90 CRI, dimmable, 24 VDC or 4.5 watts per foot. Contractor to verify quantity to fill entire length of cove, connectors, and transformer requirements prior to order. L2: Same as L1 but Wet Rated. Lumini/LineLED LL Series Wet Tube. LL54 Wet, 2700K lamping, 90 CRI, dimmable- 24 VDC or 4.5 watts per foot. Contractor to verify quantity to fill entire length of cove, connectors, and transformer requirements prior to order. W3: New wall sconce: TBD, 60 watts. Confirm final mounting height with designer prior to rough-in. R7: New LED Cove light. Lumenwerx/Alcove LED, ALC-APO-LED-90-30-D1-COVV-W. 1% dimmable. 17 watts. Contractor to verify quantity to fill entire length of cove, connectors, and transformer requirements prior to order. P7: New dome pendant light fixture over open office workstations: TBD, 13 watts. Confirm final mounting height with designer prior to rough-in. P9: New suspended lighting/mobile: TBD, 150 watts. Confirm final mounting height with designer prior to rough-in. New restroom exhaust fan - ceiling mount. Broan/E070. 4 sones. White finish. 120V, 1.5 amps. T2: Same as T1 but with a differing beam spread luminaire head. CTL-9051-M-2C-D-B , Single Circuit Line Voltage track, surface mount to ceiling. L3: LED for area with applied wood and acoustic ceiling treatment. Luminii/Zoom. 2700K, 3.25 watt/foot. 90 CRI, 0-10V dimmable. Black Finish with frosted diffuser. EM4: Evenlite/Telesis - LED Exit Sign/Combo EM light fixture with linear directional LED. White finish with red 6" letters and directional arrow (when applicable). EM1 EM1 EM4 EM4 EM1 EM1 EM1 EM1 EM1 EM1 EM1 EM1 EM4 EM4 S1: New light fixture: TBD, 100 watts 11. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT UNDER THE COUNTERTOP(S). REFERENCE ELEVATIONS FOR DETAILS. 12. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT AT BOTH UNDER THE COUNTERTOP(S) AND THE TOEKICK. REFERENCE ELEVATIONS FOR DETAILS. 13. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT UNDER THE UPPER/WALL CABINETS REFERENCE ELEVATIONS FOR DETAILS. 14. 'L3' FIXTURE IN THIS LOCATION TO TERMINATE INTO ADJACENT BULKHEAD/WALL. 'L3' DOES NOT RUN DOWN THE WALL IN THIS LOCATION. 15. EXISTING EMERGENCY LIGHT FIXTURE/EXIT SIGN COMBINATION FIXTURE. IN SHELL SCOPE. 16. CONTRACTOR TO PROVIDE 1x6 WOOD BLOCKING IN THE CEILING FOR TENANT PROVIDED ROLLER SHADES. 17. CONTRACTOR TO PROVIDE POWER IN CEILING FOR TENANT PROVIDED EXISTING CEILING-MOUNTED EXAM LIGHT. PROVIDE WOOD BLOCKING IN CEILING. SEE BLOCKING PLAN FOR DETAILS. 18. CONTRACTOR TO PROVIDE AND INSTALL 24" X 96" X 1" THICK ACOUSTIC PANELS TO EXISTING (PAINTED) DRYWALL CEILING. MANUFACTURER: SURFACE MATERIALS. SPEC: SONUS ACOUSTIC PANELS/STYLE: FLAT PANEL/COLOR: TBD/SHAPE: RECTANGULAR WITH ADDED BEVELED EDGE. PRICE DIRECT APPLICATION TO EXISTING DRYWALL CEILING USING ROTOFAST ANCHORS. CONTRACTOR TO REFERENCE QUOTE # QUO-12654-V1T9X9 FOR *PRELIMINARY* PRICING. CONTACT AMY ANDRUS AT SURFACE MATERIALS. AMYA@SURFACEMATERIALS.COM, CELL: (502) 523-2158. SURFACE MATERIALS CUSTOMER SERVICE: (440) 248-000. FINAL MATERIAL QUANTITY TAKEOFF AND LAYOUT TO BE CONFIRMED WITH DESIGNER PRIOR TO PLACING THE ORDER FOR MATERIAL. NO IN-CEILING WOOD BLOCKING REQUIRED, PER AMY ANDRUS EMAIL DATED 1/5/21 TO PHANOMEN/design. 19. 1x2 WOOD TRIM PIECE TO SURROUND ENTIRE PERIMETER OF DRYWALL BULKHEAD. ALL EXPOSED FACES OF TRIM TO BE STAINED 'ST-1'. SEE 4/A1.9 FOR DETAILS 20. THIS INSTANCE OF 'L3' WILL NOT TRAVEL DOWN THE WALL. REFERENCE KEYNOTE #8 FROM THIS SHEET. 21. REFERENCE CEILING DETAIL 6/A1.9 FOR CEILING TRANSITION DETAIL. EM4 EM4 EM4 W4: New wall sconce: TBD, 60 watts. Confirm final mounting height with designer prior to rough-in. W2: New wall sconce: TBD, 60 watts. Confirm final mounting height with designer prior to rough-in. W1: New wall sconce: TBD, 60 watts. Confirm final mounting height with designer prior to rough-in. P2: New pendant light fixture: TBD, 100 watts. Confirm final mounting height with designer prior to rough-in. 1/4"=1'-0" 2 ENLARGED PLAN 19 7 TYP. 8 20 20 20 20 8 20 21