HomeMy WebLinkAboutA1.4 Reflected Ceiling Plan and Lighting ScheduleP1
P3
P4
P5
L1
L1
11' - 0"
PT-X
11' - 0"
PT-X
9' - 6"
ACT-X
10' - 0"
PT-X
9' - 6"
ACT-X
EXT. DECK
PT-X
EXT. DECK
PT-X
9' - 6"
ACT-X
9' - 0"
ACT-X
9' - 6"
ACT-X
9' - 6"
PT-X
10' - 0"
PT-X
N.I.C.
N.I.C.
9' - 6"
ACT-X 9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
9' - 6" ACT-X
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
9' - 6" ACT-X
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
9' - 6"
ACT-X
10' - 0"
ACT-X
EXT. DECK
EXT. DECK
EXT. DECK PT-X
PT-X
10' - 0"
PT-X
10' - 0"
PT-X
EXT. DECK
EXT. DECK
9' - 6"
ACT-X
10' - 0"
PT-X
10' - 10"
WD-X
9' - 0"
ACT-X
9' - 0"
ACT-X
9' - 0"
ACT-X
9' - 0"
PT-X
10' - 0"
PT-X
13' - 0"
PT-X
8'- 0"
PT-X
8' - 0"
PT-X
9' - 10"
PT-X
8' - 0"
PT-X
L1
P6
P6
P6
L2
8' - 0"
PT-X
R2
9' - 0"
PT-X
9' - 0"
PT-X
9' - 0"
PT-X
8'- 6"
PT-X
8' - 0"
PT-X
1
AQUARIUM
MAINT.
302
AQUARIUM
MIKE
OFFICE 6
331
BREAK
ROOM
318
CONFERENCE
ROOM
316
MEDICAL
STORAGE
334
BLOOD
DRAW
303
M. PRIDDY
OFFICE 4
338
J. RIZZUTO
OFFICE 5
339
EXAM 1
306A
EX 1
PATIENT RR
306B
EXAM 2
307A
EX 2
PATIENT RR
307B
GENERAL
STORAGE
332
OFFICE 1
335
OFFICE 3
337
PHARMACY
& SAMPLES
304
OFFICE 7
330
MOLE MAPPING
(PHOTO FINDER)
329
STORAGE
305
JANITOR
328
EXAM 3
308A
EX 3
PATIENT RR
308B
LAB
322
PROCEDURE
ROOM
317
OFFICE 8
327
UNISEX
RESTROOM
319
EXAM 10
PEDIATRIC
315A
EX PED
PATIENT RR
315B
EX 4
PATIENT RR
309B
OFFICE 9
326
OFFICE 10
325
EXAM 5
310A
PROCEDURE &
BLOOD DRAW
323
SHOWER
ROOM
320
EXAM 9
314A
EX 9
PATIENT RR
314B
EXAM 8
313A
EX 8
PATIENT RR
EXAM 4 313B
309A
EX 5
PATIENT RR
310B
EX 6
PATIENT RR
311B
EX 7
PATIENT RR
312B
EXAM 6
311A
EXAM 7
312A
OFFICE 2
336
RECEPTION
300
WAITING LOUNGE
301
SOILED
LINENS
321
STORAGE
324
BACK HALL
333
OPEN
OFFICE
340
HALLWAY
341
HALLWAY
342
HALLWAY
343
HALLWAY
344
HALLWAY
345
HALLWAY
346
EXISTING
STAIR 2
NIC
EXISTING
STAIR 1
NIC
DN
DN
ELEC. ROOM
(EXIST.)
NIC
6
9' - 0"
PT-X
9' - 0"
PT-X
8' - 0"
PT-X
9' - 0"
PT-X
R3
R3
R3
9' - 0"
ACT-X
R3
9' - 6"
PT-X
8'- 0"
PT-X
7
9
11'-0"
WD-X
W2
12
R4
R4
R4
R4
R7
9' - 0"
PT-X
EXT. DECK
PT-X
W3
W3
R3
13
11
11
10
10
13
13
13
13 13 13 13 13 13
13
9' - 0"
ACT-X
L1 x 4
P8
P8
T1
T1
13
13
T2
EXT. DECK
PT-X
P8
W4
W5
R5
R3
W1
R3
9' - 6"
PT-X
10' - 0"
PT-X
P9
9' - 6"
ACT-X
EXT. DECK
PT-X
PT-X
PT-X
PT-X
9' - 6"
ACT-X
P8
P7
10' - 0"
PT-X
EXT. DECK
PT-X
EXT. DECK
PT-X
EXT. DECK
PT-X
L3
10' - 0"
PT-X
15 15
16
P8
P8
P8
R3
R2
R1
R1
R1 R1 R1
L1
R1
S1
R1
R2
R1 R1
R1
R1
R1
F1
R2
R2 P6 R2
F1
R1
R2
P6 P6
R1
R1
R1
W4
R4
R2
R2
R2
R2
R2
R2
R3
R1 R1
R2
P8
P8 P8
L3
L3 L3
R1
W1
R1 L3 L3
R1
F1
F1
F1 F1
F1
F1
F1
F1
F1
P8
P8 P8 P8 P8
P8 P8 P8 P8
P8 P8
P8
P8 P8
P8 P8 P8
P8 P8
P8
P8
P8 P8
P8
P8
P8
P8
P8
P8 P8
P8 P8 P8 P8
P8 P8
R1 R1 R1
R1 R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
T1
T1
T1
T1 T1
T1 T1 T1 T1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
R1
R1
R1
R1
R1 R1 R1 R1 R1 R1 R1
R1
R1
R1
R1
R2
R1
R1
R1
R2 R2
R2 R2
R3 R3
R3
R3
R3
R3
R1
R1
R4
R1
R1 R1
P6 P6 P6 R1
P6
P6 P6
P6
R1
R1
R1 R1
R2
R1
R3
R2
R2
R2
R1
R2 R2
R1
R1
R1
R1
R1
R2
R2
R2
R3 R1 R3
R1 R1
R1 R2
R2
R1
R2
R1
R1
R1
R2
R2 R1
R2
R1
R1 R1
R1 R1
R1 R2
R2
R3
R1
R3
R1
R2
R7 R7
R7
R7
P7
P7
P7 P7
P7
P7
P7
P7 P7
P7 P7
P7
W2
W1
W1 W1 W1 W1 W1 W1
W1
W1
R4
R3
R4
R4
R4
R2 R2
R1
R1
R1
R3
R1
R1
R1 R1
R1
R1
R2
R3
R1
R4
R1
R1
R2
R3
R3
R1
R2
R2
R1 R1
R1
R1
R2 R1
R1
R2
R2
P2
R1
R1
R1 R1
R1 R1
R1
R1
R1
R2 R2
R1
R1
R1
R1
R4
R1 R1
W1
R1 R1
R2 R2
R1 R1 R1
R3 R3
R1
R1
R1
R1
R7 R7
R7 R7 R7
16 16 16 16 16 16
L3 L3
L3 L3
F1
16
16
16
16
16
16
16
16 16 16 16 16
16
16
16
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
11'- 0"
PT-X
17
11'- 0"
PT-X
11'- 0"
PT-X
18
18
18
18
18
18
18
18
18
18
18
18
18
18
P5
L1
P6
W1
L3
R1 R2
R2
F1
R1
R2
L3
L3 L3
R1
W1
R1 L3 L3
R1
R2
R4
L3 L3
L3 L3
Certified By:
Scale:
Date:
Checked By:
Drawn By:
Job Number:
Drawing Number:
Drawing Name:
CARMEL, IN 46032
01.22.2021
www.phanomen.com
934 Fort Wayne Ave. - Indianapolis, IN 46202
317.439.4355 (t)
PRIORITY PHYSICIANS ...creating profitable environments...
Revisions:
12174 N. MERIDIAN
SUITE 300
1/8"=1'-0"
1 REFLECTED CEILING PLAN
A
S NOTED
BSH
LOE
REFLECTED CEILING PLAN
& LIGHTING SCHEDULE
A1.4
PERMIT SET 01.22.2021
# REFLECTED CEILING PLAN KEYNOTES:
GENERAL REFLECTED CEILING NOTES:
1. CENTER LIGHT FIXTURE OVER LENGTH OF RECEPTION DESK TRANSACTION TOP.
2. (NOT USED.)
3. (NOT USED.)
4. CONTRACTOR TO PROVIDE AND INSTALL WOODEN 11X17" SUSPENDED PLATFORM
FOR HVAC CONDENSATE PUMP AS REQUIRED.
5. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING AND/OR ADDITIONAL SUPPORT
IN THE STRUCTURE OF CEILING TO ACCOMMODATE FOR THE ADDITIONAL WEIGHT OF
PHANOMEN PROVIDED WINDOW COVERINGS/DRAPERY.
6. CONTRACTOR TO PROVIDE AND INSTALL L1 LED ROPE LIGHT AROUND RANGE
HOOD. REFERENCE DETAIL DRAWINGS FOR MORE INFORMATION.
7. CONTRACTOR TO PROVIDE AND INSTALL WOOD SLAT ACOUSTICAL PANEL MATERIAL
AS AN APPLIED FINISH OVER THE TOP OF THE PAINTED DRYWALL CEILING.
MANUFACTURER: ACOUSTICAL ART CONCEPTS/AKUPANEL 3X1 VN520. COORDINATE
FINAL SPECIFICATION WITH DESIGNER PRIOR TO ORDERING. SEE CEILING DETAIL SHEET
FOR MORE INFORMATION.
8. CONTRACTOR TO PROVIDE AND INSTALL 'L3' FIXTURE IN 1" GAP IN BETWEEN
ACOUSTICAL WOOD SLAT MATERIAL MENTIONED IN KEYNOTE 7 ON THIS SHEET. ALL
AREAS OF 'L3' SHOWN SHALL INSTALL ON CEILING AND DOWN WALL (90 DEGREES),
EXCEPT AS OTHERWISE NOTED ON KEYNOTE #20 OF THIS SHEET.
9. DRYWALL CEILING OVER THE SHOWER TO BE ARCHED.
EXACT RADIUS TO BE DETERMINED. CONTRACTOR TO VERIFY FINAL DESIGN AND
RADIUS WITH DESIGNER PRIOR TO FRAMING.
10. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT AT MILLWORK TOE KICK.
REFERENCE ELEVATIONS FOR DETAILS.
A. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL
CEILING HEIGHT AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK,
LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT
INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT/DESIGNER'S
ATTENTION IMMEDIATELY, PRIOR TO THE ORDER OF MATERIALS AND COMMENCEMENT
OF ANY WORK.
B. CEILINGS IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS, AND STATE AND LOCAL BUILDING CODES.
C. ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES.
D. ALL GYP. BOARD WALLS, CEILINGS AND BULKHEADS, SHALL BE A SMOOTH LEVEL 4 FINISH
AS OUTLINED IN GYPSUM ASSOCIATION GA-214.
E. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT
CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
CONFIRM ALL NEW SWITCH LOCATIONS WITH OWNER PRIOR TO ROUGH-IN.
F. ALL MATERIALS EXPOSED WITHIN THE PLENUM MUST BE NONCOMBUSTIBLE OR SHALL
COMPLY WITH LABELING, FLAME AND SMOKE DEVELOPMENT RATINGS AS SPECIFIED IN
THE CURRENT EDITION OF THE INDIANA MECHANICAL CODE.
G. MEANS OF EGRESS ILLUMINATION SHALL BE LOCATED IN ACCORDANCE WITH SECTION
G. 1006, IBC (675 IAC 13-2.5).
H. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A J-BOX OR OUTLET AS WELL AS
ANY ASSOCIATED WIRING AT LOCATIONS NOTED IN PLAN FOR DECORATIVE LED ROPE
LIGHTING AT CASEWORK NOTED. ALL DECORATIVE LED ROPE LIGHTING MATERIAL AND
CONNECTIONS WILL BE CONSIDERED A PART OF THE FINAL FINISH BUILD-OUT OF THE
TENANT SUITE.
I. CONTRACTOR TO INSTALL RECESSED LIGHT FIXTURES IN CENTER OF CEILING TILES.
TYPICAL ALL LOCATIONS AND LIGHT FIXTURE TYPES, UNLESS DRAWN OTHERWISE.
J. UNLESS NOTED OTHERWISE, ALL UNLABELED/UNHATCHED CEILINGS WILL BE ASSUMED
DRYWALL CEILING.
N
S
W
E
Above: height indication above finished floor
Mounting height to center above finished floor
NOTE: FIXTURES BELOW ARE TO BE PROVIDED AND INSTALLED BY CONTRACTOR
CONTACT SPECIFIED LIGHTING SYSTEMS FOR PRICING (TRACI ASHCRAFT AT (317) 340-9423,
TASHCRAFT@SLSINDIANA.COM )
NOTE: FIXTURES BELOW ARE TO BE PROVIDED BY PHANOMEN/design AND
INSTALLED BY THE CONTRACTOR
X'-X" A.F.F.
XX-X
+XX
R1: New recessed light fixture: Focal Point Lighting/ID + 6" round fixed LED
downlight, Model # FLC6D-RO-1500L-120-L11-T_LC6-RO-1500L-27K-DN-CD-NP, 2700K
lamping. Lumen output spec 1500, 17 watts. 90 CRI. 0-10V (1%) dimming.
Clear diffuse, white housing.
R3: New recessed 1x4 troffer light fixture: Cooper Lighting Solutions/Metalux/
Model #: ATW-14RLN-LD5-31-UNV-L92765. 90 CRI, 2700k-6500k white tuning,
30 watts. W2A White Tuning driver required. 2 channel (Intensity and CCT) control.
ACT-2: New 2x2 Suspended Ceiling System. See finish legend for spec.
REFLECTED CEILING PLAN LEGEND
EM1: New Emergency Light: Cooper Lighting/Apel Series. Two 3.6 V LED heads, in
white finish (APELH2)
EM2: Evenlite/Sovereign - LED Edgelit Exit Sign. Flat Trim for recessed ceiling mount.
Clear finish with red 6" letters. Mirror finish for all double-sided instances.
Single Pole Switch
Dimmer Switch (Install LED compatible dimmer where applicable)
3-Way Switch
Occupancy Sensor (at ceiling): provided and installed by contractor to meet
all requirements of the 2010 Indiana Energy Conservation Code
Switching Intent
Night Light Fixture
S
D
3
OP
NL
Below: ceiling finish
EM3: Evenlite/Sovereign - LED Edgelit Exit Sign. Flat Trim for recessed ceiling mount.
Clear finish with red 6" letters, with directional arrow(s).
Mirror finish for all double-sided instances.
P4: New pendant light fixture: TBD, 600 watts. Confirm final mounting height with
designer prior to rough-in.
P3: New pendant light fixture: TBD, 100 watts. Confirm final mounting height with
designer prior to rough-in.
P1: New chandelier light fixture: TBD, 600 watts. Confirm final mounting height
with designer prior to rough-in.
P5: New pendant light fixture: TBD, 100 watts. Confirm final mounting height
with designer prior to rough-in.
P6: New pendant light fixture over exam restroom vanities: TBD, 13 watts,
Confirm final mounting height with designer prior to rough-in.
P8: New LED suspended can light fixture. Focal Point Lighting/ID + 4.5" Cylinder
FLCY4-2700K-90CRI-IC-SC-L11-BXX (VERIFY WITH MOUNTING HEIGHT)
-DNT-VWFL-CD-XX (VERIFY FINAL COLOR WITH DESIGNER). 2700K, 90 CRI, 1%
dimmable, 250 watt, Swivel stem mount bottom of fixture 9'-0" AFF
R4: New recessed Linear LED perimeter light. Focal Point Lighting/Seem 2. (4"
Regress) FSM2PR-ALH-FL4-250LF-2700K-90CRI-1C-UNV-L11-XF-WH. Dimmable,19
watts. Individual lengths needed. Contractor to verify quantity to fill entire length
of cove, connectors, and transformer requirements prior to order.
R5: New recessed Linear LED perimeter light. Focal Point Lighting/Seem 2. (2.5"
Regress) FSM2PR-ALH-FL2-250LF-2700K-90CRI-1C-UNV-L11-XF-WH. Dimmable, 19
watts. Individual lengths needed. Contractor to verify quantity to fill entire length
of cove, connectors, and transformer requirements prior to order.
T1: New LED Suspended Track Light
4' track length with qty (2) LED heads per location. 9 watt/1021 lumens per head.
2700K, 90 CRI, 0-10V dimmable. Contech Lighting/CTL-9051-F-2C-D-B.
Contractor to mount Contech LT Single Circuit Line Voltage Track to unistrut at
10'-6" AFF, Bottom of track head at approx. 10'-0" AFF.
R2: New recessed light fixture: Focal Point Lighting/ID + 4.5" round adjustable LED
downlight, Model# FLCS4-RO-1500L-27K-FL-L11-T_LCS4-RD-AA-CD-NP, 2700K
lamping, 1500 lm, 25 watts, 90 CRI. 0-10V(1%) dimming. Clear diffuser, white housing.
L1: New Linear LED Tape Light: Luminii/LineLED LL Serires. LL54 (354 lumens/ft),
2700K lamping, 90 CRI, dimmable, 24 VDC or 4.5 watts per foot. Contractor to
verify quantity to fill entire length of cove, connectors, and transformer
requirements prior to order.
L2: Same as L1 but Wet Rated. Lumini/LineLED LL Series Wet Tube. LL54 Wet,
2700K lamping, 90 CRI, dimmable- 24 VDC or 4.5 watts per foot. Contractor to
verify quantity to fill entire length of cove, connectors, and transformer
requirements prior to order.
W3: New wall sconce: TBD, 60 watts. Confirm final mounting height with
designer prior to rough-in.
R7: New LED Cove light. Lumenwerx/Alcove LED, ALC-APO-LED-90-30-D1-COVV-W.
1% dimmable. 17 watts. Contractor to verify quantity to fill entire length of cove,
connectors, and transformer requirements prior to order.
P7: New dome pendant light fixture over open office workstations: TBD,
13 watts. Confirm final mounting height with designer prior to rough-in.
P9: New suspended lighting/mobile: TBD, 150 watts. Confirm final mounting
height with designer prior to rough-in.
New restroom exhaust fan - ceiling mount. Broan/E070. 4 sones. White finish.
120V, 1.5 amps.
T2: Same as T1 but with a differing beam spread luminaire head. CTL-9051-M-2C-D-B ,
Single Circuit Line Voltage track, surface mount to ceiling.
L3: LED for area with applied wood and acoustic ceiling treatment. Luminii/Zoom.
2700K, 3.25 watt/foot. 90 CRI, 0-10V dimmable. Black Finish with frosted diffuser.
EM4: Evenlite/Telesis - LED Exit Sign/Combo EM light fixture with linear directional LED.
White finish with red 6" letters and directional arrow (when applicable).
EM1
EM1
EM4
EM4
EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM4 EM4
S1: New light fixture: TBD, 100 watts
11. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT UNDER THE
COUNTERTOP(S). REFERENCE ELEVATIONS FOR DETAILS.
12. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT AT BOTH
UNDER THE COUNTERTOP(S) AND THE TOEKICK. REFERENCE ELEVATIONS FOR DETAILS.
13. CONTRACTOR TO PROVIDE AND INSTALL 'L1' LED TAPE LIGHT UNDER THE UPPER/WALL
CABINETS REFERENCE ELEVATIONS FOR DETAILS.
14. 'L3' FIXTURE IN THIS LOCATION TO TERMINATE INTO ADJACENT BULKHEAD/WALL.
'L3' DOES NOT RUN DOWN THE WALL IN THIS LOCATION.
15. EXISTING EMERGENCY LIGHT FIXTURE/EXIT SIGN COMBINATION FIXTURE. IN SHELL
SCOPE.
16. CONTRACTOR TO PROVIDE 1x6 WOOD BLOCKING IN THE CEILING FOR TENANT
PROVIDED ROLLER SHADES.
17. CONTRACTOR TO PROVIDE POWER IN CEILING FOR TENANT PROVIDED EXISTING
CEILING-MOUNTED EXAM LIGHT. PROVIDE WOOD BLOCKING IN CEILING. SEE
BLOCKING PLAN FOR DETAILS.
18. CONTRACTOR TO PROVIDE AND INSTALL 24" X 96" X 1" THICK ACOUSTIC PANELS TO
EXISTING (PAINTED) DRYWALL CEILING. MANUFACTURER: SURFACE MATERIALS.
SPEC: SONUS ACOUSTIC PANELS/STYLE: FLAT PANEL/COLOR: TBD/SHAPE:
RECTANGULAR WITH ADDED BEVELED EDGE. PRICE DIRECT APPLICATION TO EXISTING
DRYWALL CEILING USING ROTOFAST ANCHORS. CONTRACTOR TO REFERENCE
QUOTE # QUO-12654-V1T9X9 FOR *PRELIMINARY* PRICING. CONTACT AMY ANDRUS
AT SURFACE MATERIALS. AMYA@SURFACEMATERIALS.COM, CELL: (502) 523-2158.
SURFACE MATERIALS CUSTOMER SERVICE: (440) 248-000.
FINAL MATERIAL QUANTITY TAKEOFF AND LAYOUT TO BE CONFIRMED WITH DESIGNER
PRIOR TO PLACING THE ORDER FOR MATERIAL. NO IN-CEILING WOOD BLOCKING
REQUIRED, PER AMY ANDRUS EMAIL DATED 1/5/21 TO PHANOMEN/design.
19. 1x2 WOOD TRIM PIECE TO SURROUND ENTIRE PERIMETER OF DRYWALL BULKHEAD. ALL
EXPOSED FACES OF TRIM TO BE STAINED 'ST-1'. SEE 4/A1.9 FOR DETAILS
20. THIS INSTANCE OF 'L3' WILL NOT TRAVEL DOWN THE WALL. REFERENCE KEYNOTE #8
FROM THIS SHEET.
21. REFERENCE CEILING DETAIL 6/A1.9 FOR CEILING TRANSITION DETAIL.
EM4
EM4
EM4
W4: New wall sconce: TBD, 60 watts. Confirm final mounting height with
designer prior to rough-in.
W2: New wall sconce: TBD, 60 watts. Confirm final mounting height with
designer prior to rough-in.
W1: New wall sconce: TBD, 60 watts. Confirm final mounting height with
designer prior to rough-in.
P2: New pendant light fixture: TBD, 100 watts. Confirm final mounting height with
designer prior to rough-in.
1/4"=1'-0"
2 ENLARGED PLAN
19
7 TYP.
8
20
20
20
20
8 20
21