HomeMy WebLinkAboutExemption from State of Indiana (1)4/18/2021 Permit.com Mail - FW: Exemption from Design Release Requirement
https://mail.google.com/mail/u/0?ik=6e5f3b2926&view=pt&search=all&permmsgid=msg-f%3A1696839819584819002&simpl=msg-f%3A1696839819584819002 1/4
Mike Martin <mike@permit.com>
FW: Exemption from Design Release Requirement
Bill Stambaugh <bstambaugh@architecturalconcepts.com> Mon, Apr 12, 2021 at 8:00 AM
To: Mike Martin <mike@permit.com>
Cc: "Ramsey, Jason" <Jason.Ramsey@sevansolutions.com>, Parker Armen <Armen.Parker@us.mcd.com>, Debbie Cox
<dcox@architecturalconcepts.com>
This should be what was needed.
Bill Stambaugh, RA, NCARB, AIA
President
O. (317) 638-7600 c. (317) 627-9081
Architectural Concepts, Inc.
609 Massachusetts Ave. | Indy 46204 |
From: Callahan, Sean <SCallahan@dhs.IN.gov>
Sent: Monday, April 12, 2021 8:08 AM
To: Bill Stambaugh <bstambaugh@architecturalconcepts.com>
Subject: RE: Exemption from Design Release Requirement
Mr. Stambaugh,
Based on the information provided and the attached drawings, and this project is currently EXEMPT from filing with the
State of Indiana DHS Plan Review section in accordance with 675 IAC 12-6-4.
675 IAC 12-6-4 Exemptions from design release requirement
Authority: IC 22-13-2-13
Affected: IC 4-21.5; IC 12-13-4-3; IC 22-15-3
Sec. 4. (a) Design releases are necessary for construction on all Class 1 structures, except the following:
…
(b) Design releases are necessary for the remodeling or altering of all Class 1 structures, except work
limited to one (1) or more of the following:
(1) Any of the buildings or structures the new construction of which is exempted by subsection
(a).
(2) Plumbing work as follows:
4/18/2021 Permit.com Mail - FW: Exemption from Design Release Requirement
https://mail.google.com/mail/u/0?ik=6e5f3b2926&view=pt&search=all&permmsgid=msg-f%3A1696839819584819002&simpl=msg-f%3A1696839819584819002 2/4
(A) Replacement of piping, valves, or fixtures, provided that the replacement does not
involve relocation of fixtures.
(B) Installation of plumbing fixtures, provided that the drainage fixture unit count does
not exceed five (5).
(C) Replacement of water heaters with a similar type and capacity in the same
location.
(D) Installation of water heaters with a capacity of one hundred (100) gallons or less.
(3) Electrical work as follows:
(A) Replacement in the same location of electrical equipment or devices of a similar
type and rating, including an increase in current capacity in nonhazardous areas
where there is no change in voltage or phases.
(B) Portable or temporary equipment and devices energized by means of cord and
plug.
(C) Temporary installation of wiring and devices.
(D) Installation of branch circuits not exceeding the capacity of the electrical
distribution system within the existing building.
(E) Low-energy power, control, and signal circuits of Classes II and III as defined in
the Indiana Electrical Code except circuits for fire detection or fire alarm systems.
(F) Electrical wiring, apparatus, or equipment installed by a public or private utility in
the exercise of its function as a serving utility:
(i) for the generation, transmission, distribution, or metering of electrical
energy; or
(ii) in the operation of signals or the transmission of intelligence.
(G) Except for fire detection or fire alarm systems, electrical wiring, devices,
appliances, apparatus, or equipment:
(i) operating at less than twenty-five (25) volts; and
(ii) not capable of supplying more than fifty (50) watts of energy.
…
(5) Miscellaneous work as follows:
(A) Painting, papering, and replacement of coverings on:
(i) walls;
(ii) ceilings;
(iii) roofs; or
(iv) floors; and similar finish work, including replacement or reglazing of glass.
(B) Cases, counters, and partitions not over six (6) feet in height.
(C) Penetrations of nonfire-rated exterior walls where the width of the opening:
(i) does not exceed six (6) feet; and
(ii) is not for a required exit.
(D) Installation of one (1) or more nonload-bearing partitions not to exceed a total of
one hundred (100) lineal feet in length provided it is not part of a corridor or a partition
that is required to be of fire-resistive construction.
4/18/2021 Permit.com Mail - FW: Exemption from Design Release Requirement
https://mail.google.com/mail/u/0?ik=6e5f3b2926&view=pt&search=all&permmsgid=msg-f%3A1696839819584819002&simpl=msg-f%3A1696839819584819002 3/4
You may still be required to submit to local jurisdictions.
NOTIFICATION: Starting July 1, 2020, Indiana Code requires all applications to be filed electronically, unless it imposes an
undue hardship.
Please visit dhs.in.gov/3658.htm to file your project online. Email planreview@dhs.in.gov or call 317.232.6422 for any filing
questions.
Sean Callahan PE | Plan Review Assistant Section Chief
Division of Fire and Building Safety| Plan Review Branch
Indiana Department of Homeland Security
302 West Washington Street, Room E-245
Indianapolis, IN 46204
Tel: (317) 232-6422
Email: SCallahan@dhs.in.gov
Web: http://www.in.gov/dhs/3658.htm
From: Plan Review <planreview@dhs.in.gov>
Sent: Monday, April 5, 2021 8:12 AM
To: Callahan, Sean <SCallahan@dhs.IN.gov>
Subject: FW: Exemption from Design Release Requirement
Exemption request
Rex Mays CCRI CCBI CPE/ Deputy Director
Division of Fire and Building Services/Plan Review Branch
Industrialized Building System Administrator
Indiana Department of Homeland Security
302 West Washington Street, RM E-245
Indianapolis, Indiana 46204
Tel: (317) 232-1408
4/18/2021 Permit.com Mail - FW: Exemption from Design Release Requirement
https://mail.google.com/mail/u/0?ik=6e5f3b2926&view=pt&search=all&permmsgid=msg-f%3A1696839819584819002&simpl=msg-f%3A1696839819584819002 4/4
Email: rmays@dhs.in.gov
Web: https://www.in.gov/dhs/3658.htm
NOTIFICATION: Starting July 1, 2020, Indiana Code requires all applications to be filed electronically, unless it imposes
an undue hardship.
Please visit dhs.in.gov/3658.htm to file your project online. Email planreview@dhs.in.gov or call 317.232.6422 for any
filing questions.
From: Bill Stambaugh <bstambaugh@architecturalconcepts.com>
Sent: Thursday, April 1, 2021 4:14 PM
To: Plan Review <planreview@dhs.in.gov>
Cc: Ramsey, Jason <Jason.Ramsey@sevansolutions.com>; Debbie Cox <dcox@architecturalconcepts.com>
Subject: Exemption from Design Release Requirement
**** This is an EXTERNAL email. Exercise caution. DO NOT open attachments or click links from
unknown senders or unexpected email. ****
[Quoted text hidden]
130093 Carmel Drive 200033 SAO Final.pdf
7262K