Loading...
HomeMy WebLinkAboutA010.4A B 1 2 3 4 5 6 1 2 3 4 5 6 106VACANT105 GARBANZO 104RESTORE HYPERWELLNESS 103 RISE 'N ROLL 102 DRY CLEANER 101TROPICAL SMOOTHIECAFE 45'-8"29'-0" 59'-0"28'-0" 18'-8" 180'-4" 183'-8"59'-4"62'-8"1'-8" 1'-8"3 A201 7'-7" 1'-4" 3'-4" 11'-5 3 8" 7'-0" 16'-75 8" 1'-4" 3'-4" 38'-4" 3'-4"11'-115 8" 3'-4"1'-4" 30'-83 8" 6'-4" 61'-0" 1'-4" 7'-0" 1'-4" 3'-4" 22'-4" 27'-0" 48'-4" 7'-0" 29'-018" 3'-4" 7'-77 8"1'-4" 5'-4" 12'-8" 2'-6" 28'-4" 25'-8" 2'-6" 5'-4" 5'-2" 3'-9" 4'-0" 9'-4" 3'-5"8'-8"2 A201 4 A201 SF3 SF2 SF6 SF3 SF3 SF1 SF3 SF5 SF3 SF4 SF3 SF2 59'-4"62'-8"1'-8" 1'-8"5'-4" 12'-8" 2'-6" 28'-4" 25'-8" 2'-6" 5'-4" 8'-2" 9'-4" 8'-2"8'-8"45'-8"29'-0" 59'-0" 28'-0" 18'-8" 180'-4" 183'-8" 5'-4" 3'-8" 12'-8" 3'-8" 5'-4" 16'-8" 4'-2" 12'-8" 2'-0" 12'-8" 2'-0" 30'-8" 5'-4" 61'-0" 5'-4" 4'-0" 19'-0" 27'-0" 48'-4" 5'-4" 27'-0" 5'-4"5'-4" 5'-4" 4'-0" 8'-8" 12'-8"4'-0" 4'-0" 4'-2" 1 A201 8" 8" 8" 8"4'-0"4'-0"4'-0"4'-0"8"8"8"8"8"8"4'-0"4'-0"4'-0"4'-0"8"8"8"8"8"8"100 101102103104105106108110112113111109107 1 3 4 5 5 5 5 2 TYP 2 TYP 6 A5017 A501 8 A501 8 A501 OPP 6 A501 SIM 6 A501 SIM OPP 6 A501 SIMOPP 7 A501 OPP 7 A501SIMOPP 7 A501 SIMOPP 6 A501 SIM 6 A501SIMOPP 6 A501 SIM 6 A501 SIMOPP W1A W1A W1A 22'-7 3 8" CENTER TO CENTER 36'-3 3 4" CENTER TO CENTER 7 7 77 776 TYP 6 TYP 6 TYP 6 TYP 7 77 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 78 1 A102W2A18'-4"114115 116 2 A102 3 A102 A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR METAL STUD FRAMING, UNLESS OTHERWISE NOTED. C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL. D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS FOR ANY WALL SUPPORTED ITEMS. E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY OPENINGS IN FIRE RATED ASSEMBLIES. F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS, FINISHES, AND HARDWARE INFORMATION. G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND OTHER EXPANSION JOINT LOCATIONS. H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING, TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR CEILING HUNG ITEMS. I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY THE ARCHITECT. J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS, ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION. K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME. L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL. M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF THE ANSI 117.1 2009 GENERAL NOTES KEYED NOTES KEY PLAN ISSUE DATE 200275 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. COPYRIGHT 2021, CURRANARCHITECTUREC PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM MULTI-TENANT BUILDING 11100 N. MICHIGAN ROAD CARMEL, INDIANA 46077 NPROJECT LOCATION BENNET T P KWY U.S. HIGHWAY 421PERMIT SET 02.25.2021 REED RD.FLOOR PLAN A101 1FLOOR PLAN 1/8 "= 1'-0" *THIS SHEET ONLY 1. METER BASE. SEE MEP PLANS. 2. DASHED LINE INDICATES AWNING ABOVE. SEE ELEVATIONS AND ROOF PLAN. 3. WALL MOUNTED BIKE RACKS. SEE ELEVATIONS. 4. ROOF LADDER. SEE 5/A305 5. WALL TO BE CENTERED ON COLUMN LINE. 6. SEE WALL SECTIONS FOR DRYWALL EXTENTS. 7. STONE PRODUCT RETURNS THIS WALL. 8. TANK FILL BOX: CHART, PERMA WALL BOX GEN II, SURFACE MOUNT. COORDINATE FINAL LOCATION & CLEARANCES WITH TENANT.N04/28/21