HomeMy WebLinkAboutA010.12 rev 1TYPE F SEE DOOR SCHEDULESEE DOOR SCHEDULE TYPE FGSEE DOOR SCHEDULESEE DOOR SCHEDULE 12"DOOR HEIGHTDOOR WIDTH TYPE F1 SF1 SF2 1 FIN FLOOR T T T T T T T A A A A A A A A A A A A A A 10'-2" 6'-10"21'-2" EQ 4'-10"2'-0" 10" EQ EQ EQ EQ 2'-5" 2'-5" 21'-2" EQ 10" EQEQ EQ EQ 2'-5" 2'-5"10'-2" 6'-10"4'-10"2'-0" 24'-2 1 2" EQ DOOR WIDTH EQ EQ 2'-5" 18'-5 1 4" EQDOOR WIDTH EQ EQ 2'-5" 2 2 4 T T T T A A A A A A A A A A DOOR HEIGHTDOOR WIDTH TYPE F2 T A T A AA 2'-5" EQ SF3 SF4 SF5 SF6 2'-8" 4'-4"4'-0" 3 10'-2" 6'-10"4'-10"2'-0" 6'-6" EQEQ 6'-6" EQ EQ 2 2 2 4 10'-2" 6'-10"4'-10"2'-0" 9'-9 1 4" EQEQ EQ 9'-914" EQEQEQ 10'-0"4'-10"2'-0" T T TT T A A A A A A A A A A A A A A DOOR AND FINISH SCHEDULE A601 ISSUE DATE 200311 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. COPYRIGHT 2021, CURRANARCHITECTUREC PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM OUTLOT BUILDING 11150 N. MICHIGAN ROAD CARMEL, INDIANA 46077 PERMIT SET 02.25.2021 HARDWARE SET #01 3 HINGES (NON PULL HINGE PINS) 1 PANIC BAR 1 HEAVY DUTY LATCH GUARD 1 INERCHANGEABLE CYLINDER LOCK AND HAND GRIP 1 LOW PROFILE THRESHOLD 1 SWEEP 1 WEATHER STRIPPING 1 18 GA. DRIP EDGE FINISH: US26D DOOR HARDWARE DOOR TYPES NOT TO SCALE DOOR FRAME TYPES NOT TO SCALE HARDWARE SET #02 6 HINGES 1 PULL 1 DEAD BOLT CYLINDER (COORD. CYLINDER LOCATION W/ TENANT) 2 PUSH BAR INTERIOR 1 PERIMETER SEAL 2 LOW PROFILE THRESHOLD 2 CLOSER 2 SWEEP FINISH: US26D GLAZING TYPES A. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED CLEAR GLASS. B. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED CLEAR TEMPERED GLASS. C. SECTION OF GLAZING REQUIRED TO BE 1/4" GLASS. D. SECTION OF GLAZING REQUIRED TO BE 1/4" TEMPERED GLASS. E. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED TEMPERED GREY TINTED SPANDREL GLASS. EXTERIOR GLAZING MUST MEET THE FOLLOWING SPECIFICATIONS FOR ENERGY CODE COMPLIANCE: LOW "E" COATING "U" VALUE - MINIMUM OF 0.28 "SHGC" VALUE - MAXIMUM OF 0.47 DOOR SCHEDULE MARK DOOR SIZE MATERIAL GLAZING FINISH RATING FRAME MATERIAL FINISH RATING HARDWARE REMARKS 100 FG (2) 3'-0" X 7'-0" ALUM BLACK ANODIZED - ALUM BLACK ANODIZED - 02 # 1,2,4 101 F 3'-0" X 7'-0" INSUL STEEL - PAINT - F1 HM PAINT - 01 # 3 102 f 3'-0" X 7'-0" SCWD - PRE-FINISH - F2 KD PAINT - 03 - REMARKS: 1. ALUMINUM STOREFRONT FRAMING WITH DOOR. DOOR IS RESPONSIBILITY OF ALUMINUM STOREFRONT FRAMING MANUFACTURER AND MUST BE SIZED TO FIT INTO FRAMING AS DETAILED. PROVIDE WIDE STILE DOOR, WITH MINIMUM 10" BOTTOM RAIL FOR ADA COMPLIANCE. 2. SEE STOREFRONT ELEVATIONS FOR FRAME INFORMATION. 3. PROVIDE INSULATED STEEL DOOR AND FRAME. PAINT TO MATCH ADJACENT MATERIALS. COLOR TO BE SELECTED BY ARCHITECT. 4. GLAZING IN EXTERIOR DOOR TO BE TEMPERED INSULATED GLASS SIMILAR TO GLAZING TYPE B. A. ALL PRE-FINISHED WOOD DOORS SHALL BE SOLID CORE WITH WOOD VENEER, MARSHFIELD OR EQUIVALENT. PROVIDE FINISH SAMPLE AND DOOR CONSTRUCTION DIAGRAM FOR APPROVAL AND HARDWARE BLOCKING COORDINATION. VENEER TO BE WHITE BIRCH OR MAPLE, FREE OF DARK GRAINS UNLESS OTHERWISE NOTED. B. WOOD DOORS SHALL ONLY BE INSTALLED IN CONDITIONED SPACE. C. ALL HARDWARE TO BE MINIMUM 6 PIN BEST COMPATIBLE SYSTEM. COORDINATE KEYING WITH OWNER. D. TEMPERED AND ANNEALED GLASS TO BE CLEANED PER MANUFACTURER REQUIREMENTS. NYLON CLOTH METHODS PREFERRED. DO NOT USE RAZOR BLADES ON GLASS. E. GLASS AROUND DOORS AND IN DOORS SHALL BE TEMPERED UNLESS OTHERWISE NOTED IN ELEVATIONS. F. ANY RATED DOORS TO HAVE LABEL INSTALLED IN JAMB. G. ALL EXITS DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF THE ANSI 117.1 2009. H. INSTALL OWNER PROVIDED ADA COMPLIANT RESTROOM SIGNAGE, VERIFY WITH ARCHITECT. GENERAL DOOR AND GLAZING NOTES KEYED NOTES 1. OPENING REQUIRED FOR DOOR OR PAIR OF DOORS-SEE FLOOR PLAN FOR DOOR NUMBER, SWING ETC. REFER TO DOOR SCHEDULE FOR DOOR SIZES THAT WILL DETERMINE OPENING REQUIRED. DOORS ARE RESPONSIBILITY OF STOREFRONT FRAMING MANUFACTURER AND MUST COMPLY WITH ALL STATE AND LOCAL ADA CODE REQUIREMENTS. 2. 4 1 2" X 2" EXTRUDED ALUMINUM STOREFRONT FRAMING SYSTEM. TYPICAL ALL STOREFRONT UNLESS OTHERWISE NOTED. SEE SCHEDULE FOR FINISH. SUPPLIER TO VERIFY WIND LOAD CALCULATIONS AND VERIFY STOREFRONT CONDITION. SHOULD CURTAIN WALL BE REQUIRED, PLEASE NOTIFY ARCHITECT. YKK OR EQUAL. 3. DRIVE-THRU WINDOW. MAKE & MODEL TO BE DETERMINED. 4. SEE DETAIL 1/A502. HARDWARE SET #03 3 HINGES 1 PRIVACY LOCKSET 1 DOOR STOP 1 CLOSER 3 MUTES FINISH: US26D 1 CITY REVIEW 00.00.2021 1 04/28/21