Loading...
HomeMy WebLinkAboutA010.12 rev 1TYPE FSEE DOOR SCHEDULE SEE DOORSCHEDULETYPE FGSEE DOOR SCHEDULE SEE DOORSCHEDULE12" DOOR HEIGHT DOORWIDTHTYPE F1SF1SF21FIN FLOORTTTTTTTAAAAAAAAAAAAAA10'-2" 6'-10"21'-2"EQ4'-10"2'-0"10"EQEQEQEQ2'-5"2'-5"21'-2"EQ10"EQEQEQEQ2'-5"2'-5"10'-2" 6'-10" 4'-10"2'-0"24'-212"EQDOOR WIDTHEQEQ2'-5"18'-514"EQDOOR WIDTHEQEQ2'-5"224TTTTAAAAAAAAAADOOR HEIGHT DOORWIDTHTYPE F2TATAAA2'-5"EQSF3SF4SF5SF62'-8"4'-4"4'-0"310'-2"6'-10"4'-10"2'-0"6'-6"EQEQ6'-6"EQEQ222410'-2"6'-10"4'-10"2'-0"9'-914"EQEQEQ9'-914"EQEQEQ10'-0"4'-10"2'-0"TTTTTAAAAAAAAAAAAAADOOR AND FINISHSCHEDULEA601ISSUEDATE200311THIS DRAWING AND THE IDEAS, DESIGNSAND CONCEPTS CONTAINED HEREIN ARETHE EXCLUSIVE INTELLECTUAL PROPERTYOF CURRAN ARCHITECTURE, AND ARE NOTTO BE USED OR REPRODUCED, WHOLE ORIN PART, WITHOUT THE WRITTENCONSENT OF CURRAN ARCHITECTURE.COPYRIGHT 2021, CURRAN ARCHITECTURECPROJECT INFORMATIONCERTIFICATIONISSUE DATESF :: 317 . 288 . 0753O :: 317 . 288 . 0681INDIANAPOLIS, IN 462165719 LAWTON LOOP E. DR. #212JDF DEVELOPMENTTHE AVENUEAT BENNETT FARMOUTLOT BUILDING11150 N. MICHIGAN ROADCARMEL, INDIANA46077PERMIT SET02.25.2021HARDWARE SET #013HINGES (NON PULL HINGE PINS)1PANIC BAR1HEAVY DUTY LATCH GUARD1INERCHANGEABLE CYLINDERLOCK AND HAND GRIP1LOW PROFILE THRESHOLD1SWEEP1WEATHER STRIPPING118 GA. DRIP EDGEFINISH: US26DDOOR HARDWAREDOOR TYPESNOT TO SCALEDOOR FRAME TYPESNOT TO SCALEHARDWARE SET #026HINGES1PULL1DEAD BOLT CYLINDER (COORD.CYLINDER LOCATION W/TENANT)2PUSH BAR INTERIOR1PERIMETER SEAL2LOW PROFILE THRESHOLD2CLOSER2SWEEPFINISH: US26DGLAZING TYPESA.SECTION OF GLAZING REQUIRED TO BE 1" INSULATED CLEARGLASS.B.SECTION OF GLAZING REQUIRED TO BE 1" INSULATED CLEARTEMPERED GLASS.C.SECTION OF GLAZING REQUIRED TO BE 1/4" GLASS.D.SECTION OF GLAZING REQUIRED TO BE 1/4" TEMPERED GLASS.E.SECTION OF GLAZING REQUIRED TO BE 1" INSULATED TEMPEREDGREY TINTED SPANDREL GLASS.EXTERIOR GLAZING MUST MEET THE FOLLOWING SPECIFICATIONS FORENERGY CODE COMPLIANCE:LOW "E" COATING"U" VALUE - MINIMUM OF 0.28"SHGC" VALUE - MAXIMUM OF 0.47DOOR SCHEDULEMARKDOORSIZEMATERIALGLAZINGFINISHRATINGFRAMEMATERIALFINISHRATINGHARDWAREREMARKS100FG(2) 3'-0" X 7'-0"ALUMBLACKANODIZED-ALUMBLACKANODIZED-02# 1,2,4101F3'-0" X 7'-0"INSUL STEEL-PAINT-F1HMPAINT-01# 3102f3'-0" X 7'-0"SCWD-PRE-FINISH-F2KDPAINT-03-REMARKS:1. ALUMINUM STOREFRONT FRAMING WITH DOOR. DOOR IS RESPONSIBILITY OF ALUMINUM STOREFRONT FRAMING MANUFACTURER AND MUST BE SIZED TO FIT INTO FRAMING AS DETAILED. PROVIDE WIDE STILE DOOR, WITH MINIMUM 10" BOTTOM RAIL FOR ADA COMPLIANCE.2. SEE STOREFRONT ELEVATIONS FOR FRAME INFORMATION.3. PROVIDE INSULATED STEEL DOOR AND FRAME. PAINT TO MATCH ADJACENT MATERIALS. COLOR TO BE SELECTED BY ARCHITECT.4. GLAZING IN EXTERIOR DOOR TO BE TEMPERED INSULATED GLASS SIMILAR TO GLAZING TYPE B.A.ALL PRE-FINISHED WOOD DOORS SHALL BE SOLID CORE WITHWOOD VENEER, MARSHFIELD OR EQUIVALENT. PROVIDE FINISHSAMPLE AND DOOR CONSTRUCTION DIAGRAM FOR APPROVALAND HARDWARE BLOCKING COORDINATION. VENEER TO BEWHITE BIRCH OR MAPLE, FREE OF DARK GRAINS UNLESSOTHERWISE NOTED.B.WOOD DOORS SHALL ONLY BE INSTALLED IN CONDITIONEDSPACE.C.ALL HARDWARE TO BE MINIMUM 6 PIN BEST COMPATIBLE SYSTEM.COORDINATE KEYING WITH OWNER.D.TEMPERED AND ANNEALED GLASS TO BE CLEANED PERMANUFACTURER REQUIREMENTS. NYLON CLOTH METHODSPREFERRED. DO NOT USE RAZOR BLADES ON GLASS.E.GLASS AROUND DOORS AND IN DOORS SHALL BE TEMPEREDUNLESS OTHERWISE NOTED IN ELEVATIONS.F.ANY RATED DOORS TO HAVE LABEL INSTALLED IN JAMB.G.ALL EXITS DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OFTHE ANSI 117.1 2009.H.INSTALL OWNER PROVIDED ADA COMPLIANT RESTROOMSIGNAGE, VERIFY WITH ARCHITECT.GENERAL DOOR ANDGLAZING NOTESKEYED NOTES1.OPENING REQUIRED FOR DOOR OR PAIR OF DOORS-SEE FLOORPLAN FOR DOOR NUMBER, SWING ETC. REFER TO DOORSCHEDULE FOR DOOR SIZES THAT WILL DETERMINE OPENINGREQUIRED. DOORS ARE RESPONSIBILITY OF STOREFRONTFRAMING MANUFACTURER AND MUST COMPLY WITH ALL STATEAND LOCAL ADA CODE REQUIREMENTS.2.4 12" X 2" EXTRUDED ALUMINUM STOREFRONT FRAMING SYSTEM.TYPICAL ALL STOREFRONT UNLESS OTHERWISE NOTED. SEESCHEDULE FOR FINISH. SUPPLIER TO VERIFY WIND LOADCALCULATIONS AND VERIFY STOREFRONT CONDITION. SHOULDCURTAIN WALL BE REQUIRED, PLEASE NOTIFY ARCHITECT. YKKOR EQUAL.3.DRIVE-THRU WINDOW. MAKE & MODEL TO BE DETERMINED.4.SEE DETAIL 1/A502.HARDWARE SET #033HINGES1PRIVACY LOCKSET1DOOR STOP1CLOSER3MUTESFINISH: US26D1CITY REVIEW00.00.20211