HomeMy WebLinkAboutM100 HVAC DETAILS SCHEDULE & PLANSS-1 100 S-1 100 S-1 125 S-1 125 S-1 125 S-2 75 S-1 150 S-1 150 S-1 200 S-1 120 S-3 220 S-3 220 S-3 130 S-2 75 S-3 175 S-3 200 S-3 200 S-2 75 S-3 150 S-3 150 6"Ø R-1 R-1 6"Ø 6"Ø 6"Ø 8"Ø 8"Ø 8"Ø 8"Ø 14/12 20/12 12"Ø 12/12 16/12 18/12 6"Ø 6"Ø 8"Ø 8"Ø 8"Ø 8"Ø 8"Ø 10"Ø 10"Ø 8"Ø 8"Ø 8"Ø 8"Ø 8"Ø R-1 R-1 R-1 R-2 R-2 R-3 R-1 R-2 18/12 8"Ø 12"Ø 10"Ø 8"Ø 6"Ø 6"Ø 18/12 14/12 8"Ø 8"Ø 8"Ø T EXISTING 7.5 TON EF-1 75 EF-1 75 8"Ø R-1 R-1 R-1 M100 HVAC DETAILS, SCHEDULE, & PLANS ZIONSVILLE, IN 1417 N HARDING ST. INDIANAPOLIS, IN 46202 (317) 634-8151 PHONE (317) 634-8152 FAX IDEAL HEATING, A/C & REFRIGERATION, INC. BACH TO ROCK ZIONSVILLE 10985 N MICHIGAN ROAD P R O F E S S I O N A L E N G I N E E R D E N A D I I N A G E R R T S I E STATE OF No. 11900828 J E F F R E Y M . P E R K E Y 1 SCALE: 1/4" = 1'-0" FIRST FLOOR HVAC PLAN SOUTH GENERAL NOTES: 1. REFERENCE SHEET M-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFERENCE SHEET M002 FOR DETAILS AND SCHEDULES. 3. DEMOLITION PLANS ARE DIAGRAMMATIC AND BASED ON LIMITED SURVEY DATA. HVAC CONTRACTOR SHALL VISIT SITE, EXAMINE ALL PLANS AND DETERMINE EXISTING ELEMENTS TO REMAIN AND EXISTING TO BE REMOVED AS NEEDED TO MEET DESIGN INTENT. HVAC CONTRACTOR SHALL RECOVER ALL REFRIGERANTS AND DISPOSE OF ALL HVAC SYSTEMS PER EPA REQUIREMENTS. HVAC CONTRACTOR SHALL MAP OUT EXISTING DUCTWORK TO REMAIN, SEAL AND INSULATE PER SPECIFICATIONS AND REMOVE ALL UNUSED BRANCHES. EXISTING TRANE RTU (YSC092H3EHA03) 7.5 TON. TIE NEW DUCT WORK TO EXISTING DUCT DROPS ROUT EXHAUST UP THROUGH ROOF WITH 6" FLUE PIPE PER DETAIL. ROUTE DUCT WORK TIGHT TO STEEL STRUCTURE. KEY NOTES: 1 SCALE : NONE EXHAUST FAN TERMINAL DETAIL A ROUND CHIMNEY TOP METALBESTOS FLUE FLASHING ROOF STORM COLLAR METAL ROOF BRACE TO STRUCTURE LISTED METALBESTOS FLUE PIPE MINIMUM 3'-6" ABOVE ROOF LINE SINGLE WALL DUCTING TO FAN. 30° MAX O CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. ECCENTRIC TRANSITION MAX, 30 DEG. 30° MAX NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). WHERE "R" IS EQUAL TO OR GREATER THAN "A" MINIMUM RADIUS (R) = 4 INCHES. R=A A DUCT CONSTRUCTION DETAILS B SCALE: NONE 45 DEG. OCL CONNECTION TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED RECTANGULAR DUCT BRANCH AIR FLOW V.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY SEALED ROUND SHEET METAL DUCT TO DIFFUSER 1 1 8" NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE-OFF. AIR FLOW LAY-IN DIFFUSER DETAIL C NO SCALE SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER ELBOW FITTING WITH DRAWBANDS. SHEET METAL ELBOW 1-1/2" DUCT WRAP COVER ENTIRE BACK SIDE OF DIFFUSER TO T BARS. SUPPLY DIFFUSER CEILING SEE SPECIFICATIONS FOR MAXIMUM LENGTH OF FLEX, NO KINKS SUPPORT WITH MINIMUM 2" NYLON STRAP. REFERENCE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN AND COORDINATE INSTALLATION WITH ALL CEILING ELEMENTS. 1 2 2 3 3 04/29/21