HomeMy WebLinkAboutM100 HVAC DETAILS SCHEDULE & PLANSS-1
100
S-1
100
S-1
125
S-1
125
S-1
125
S-2
75
S-1
150
S-1
150
S-1
200
S-1
120
S-3
220
S-3
220
S-3
130
S-2
75
S-3
175
S-3
200
S-3
200
S-2
75
S-3
150
S-3
150
6"Ø
R-1
R-1
6"Ø
6"Ø
6"Ø
8"Ø
8"Ø
8"Ø
8"Ø
14/12 20/12
12"Ø 12/12 16/12 18/12
6"Ø
6"Ø
8"Ø
8"Ø
8"Ø
8"Ø
8"Ø 10"Ø
10"Ø
8"Ø
8"Ø
8"Ø
8"Ø
8"Ø
R-1
R-1
R-1
R-2
R-2
R-3
R-1
R-2
18/12
8"Ø
12"Ø 10"Ø
8"Ø
6"Ø
6"Ø
18/12
14/12
8"Ø
8"Ø
8"Ø
T
EXISTING
7.5 TON
EF-1
75
EF-1
75
8"Ø
R-1
R-1
R-1
M100
HVAC DETAILS, SCHEDULE, & PLANS
ZIONSVILLE, IN
1417 N HARDING ST.
INDIANAPOLIS, IN 46202
(317) 634-8151 PHONE
(317) 634-8152 FAX
IDEAL HEATING, A/C
& REFRIGERATION, INC.
BACH TO ROCK ZIONSVILLE
10985 N MICHIGAN ROAD
P
R
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
D
E
N
A
D
I
I
N
A
G
E
R
R
T
S
I
E
STATE OF
No.
11900828
J
E
F
F
R
E
Y
M
.
P
E
R
K
E
Y
1 SCALE: 1/4" = 1'-0"
FIRST FLOOR HVAC PLAN SOUTH
GENERAL NOTES:
1. REFERENCE SHEET M-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEET M002 FOR DETAILS AND
SCHEDULES.
3. DEMOLITION PLANS ARE DIAGRAMMATIC AND
BASED ON LIMITED SURVEY DATA. HVAC
CONTRACTOR SHALL VISIT SITE, EXAMINE ALL
PLANS AND DETERMINE EXISTING ELEMENTS TO
REMAIN AND EXISTING TO BE REMOVED AS
NEEDED TO MEET DESIGN INTENT. HVAC
CONTRACTOR SHALL RECOVER ALL
REFRIGERANTS AND DISPOSE OF ALL HVAC
SYSTEMS PER EPA REQUIREMENTS. HVAC
CONTRACTOR SHALL MAP OUT EXISTING
DUCTWORK TO REMAIN, SEAL AND INSULATE
PER SPECIFICATIONS AND REMOVE ALL UNUSED
BRANCHES.
EXISTING TRANE RTU (YSC092H3EHA03) 7.5 TON.
TIE NEW DUCT WORK TO EXISTING DUCT DROPS
ROUT EXHAUST UP THROUGH ROOF WITH 6" FLUE
PIPE PER DETAIL.
ROUTE DUCT WORK TIGHT TO STEEL STRUCTURE.
KEY NOTES:
1
SCALE : NONE
EXHAUST FAN TERMINAL DETAIL
A
ROUND CHIMNEY TOP
METALBESTOS FLUE
FLASHING
ROOF
STORM COLLAR
METAL ROOF
BRACE TO STRUCTURE
LISTED
METALBESTOS FLUE PIPE
MINIMUM 3'-6"
ABOVE ROOF LINE
SINGLE WALL DUCTING
TO FAN.
30° MAX
O
CONCENTRIC
TRANSITION MAX, 45
DEG. DIVERGING AND
60 DEG. CONVERGING
OFFSET. PROVIDE MINIMUM 2"
STRAIGHT SECTION AT EACH
END. MAX 30 DEG.
ECCENTRIC TRANSITION MAX,
30 DEG.
30° MAX
NOTE:
IN GENERAL, ELBOWS TO HAVE
FULL TURNING RADIUS (R=A).
WHERE "R" IS EQUAL TO OR
GREATER THAN "A" MINIMUM
RADIUS (R) = 4 INCHES.
R=A
A
DUCT CONSTRUCTION DETAILS
B SCALE: NONE
45 DEG.
OCL CONNECTION
TAKE OFF. HAMMER
LOCKED OR FLANGED AND
FULLY SEALED
RECTANGULAR
DUCT
BRANCH
AIR FLOW
V.D.
45 DEG. HIGH EFFICIENCY
TAKE OFF COMPLETELY
SEALED
ROUND SHEET METAL
DUCT TO DIFFUSER
1
1
8"
NOTE:
DOUBLE THICKNESS
TURNING VANES TO BE USED
WHERE NORMAL RADIUS
ELBOW IS IMPRACTICAL
& WHERE ELBOW IS WITHIN 5
FT OF A
BRANCH TAKE-OFF.
AIR FLOW
LAY-IN DIFFUSER DETAIL
C NO SCALE
SECURE FLEXIBLE DUCT TO
SUPPLY DIFFUSER ELBOW
FITTING WITH DRAWBANDS.
SHEET METAL ELBOW
1-1/2" DUCT WRAP COVER
ENTIRE BACK SIDE OF
DIFFUSER TO T BARS.
SUPPLY DIFFUSER
CEILING
SEE SPECIFICATIONS FOR
MAXIMUM LENGTH OF FLEX, NO
KINKS SUPPORT WITH MINIMUM
2" NYLON STRAP.
REFERENCE ARCHITECTURAL
REFLECTED CEILING PLAN AND
ELECTRICAL LIGHTING PLAN
AND COORDINATE
INSTALLATION WITH ALL
CEILING ELEMENTS.
1
2
2
3
3
04/29/21