Loading...
HomeMy WebLinkAboutBldg B Roof Truss LayoutIRC-2018, TPI-2014, NFPA-13, BCSI-06. 20-10-10 ROOF LOADING@24" O.C. @L/360, TL/240. METAL PLATE CONNECTED WOOD ROOF TRUSSES. DIMENSIONS ARE STUD TO STUD FRAMING. (FEET-INCHES-SIXTEENTHS) ALL BRACING(TEMP. &PERM.) AND BRACINGDESIGN BYOTHERS, SEE PLAN AND BCSI. ALL CONVENTIONAL FRAMING, BLOCKING, SHEATHING, SHEAR HARDWARE AND RELATED CONNECTIONS BYOTHERS. TRUSS LUMBER IS KD19 SPF AND/OR SP-SYP, AS NEEDED, PER EACH DESIGN FOR THE REQUIRED LOADINGAND DEFLECTION CRITERIA. (NO TREATED OR FIRE TREATED LUMBER USED. TRUSSES CANNOT COME INTO DIRECT CONTACT WITH CONCRETE) BEAMS (DROPPED OR FLUSH AS NOTED) PER PLAN AND SEPARATION SHEATHINGBYOTHERS. HARDWARE 34 - LUS24 150 - H2.5A ATTIC ACCESS FIELD FRAME LOW PORCH ROOFS BYBLDR. FIELD FRAME LOW PORCH ROOFS BYBLDR. SADDLE BYBLDR. LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 FRAMER TO FIELD VERIFYALL PLUMBING, HVAC, SPRINKLER, ELECTRICAL AND ROOF DRAIN LOCATIONS. PLUMBINGVENT STACKS TO BE FIELD LOCATED IN BETWEEN TRUSSES AND STUDS WHERE POSSIBLE. TRUSSES CANNOT BE CUT, DRILLED OR NOTCHED. BLOCKINGBETWEEN TRUSSES FOR PARALLEL WALLS BELOW BYBLDR. FRAMER TO SOLID BLOCK ALL POINT LOADS TO THE FOUNDATION. ROOF TRUSS SPACINGBASED ON ATTIC ACCESS LOCATIONS. 2X4 PURLINS BYBLDR. 2X4 PURLINS BYBLDR. ATTIC ACCESS PARAPET WALL BYBLDR. PER PLAN SADDLE BYBLDR. ATTIC ACCESS RITTENHOUSE1 CHATHAM2 CHATHAM2 PRELIMINARYBLDG. B PARAPET WALL BYBLDR. PER PLAN PARAPET WALL BYBLDR. PER PLAN PARAPET WALL BYBLDR. PER PLAN PARAPET WALL BYBLDR. PER PLAN TG01 T07 T06 T05 T04 T03 T02 J04 JG01 J03 JG02 CG01 CG02 J08 J05 J09 J06 T06 T05 T04 T03 T02 T07 TG01 J05 J07 CG03 JG01 J04 J03 JG02 CG04 J10 J08 GE01 GE01 GE01B GE01A GE01D GE01C T01(3) T01(3) T01A(13) J01(10) J01(10) J02(3) J02(3) GE01(2) 37-00-00 24-00-00 4-00 24-00-00 4-00 24-00-00 24-00-00 4-00 24-00-00 4-00 24-00-00 2-00-00 2-00-00 2-00-00 2-00-00 72-08-00 IRC 2018 TPI 2014 20TCLL - 10TCDL - 10BCDL ONYX +EAST, LLC. UPTOWN WEST CLAY BUILDINGB ROOF 1/4"=1' March28, 2021 JSG B21100775 CUSTOMER: PROJECT: LOCATION: JOB #: DATE: DESIGNER: DESIGN INFORMATION: SCALE: 9028 OldSR 67 South Mooresville, IN 46158 (317) 834-5380 Truss Placement Guide 1) This layout is intended for the purpose of truss location and placement only. Refer to the building plans for actual building construction. 2) All dimensions shown 00-00-00 are in feet-inches-sixteenths. 3) Trusses are spaced 24" on center unless otherwise noted. 4) Do not cut or modify trusses. 5) Refer to the individual truss design drawings for the location of member bracing, uplift and truss end reactions. 6) Installation of all temporary and permanent bracing is essential. See truss drawings, BCSI-B2 Summary Sheet and building designer requirements. III CARMEL, IN. 46032 04/29/21