HomeMy WebLinkAboutBldg B 3rd Floor Truss LayoutIRC-2018, TPI-2014, BCSI-06.
40-20-10 FLOORLOADING@16"O.C. &19.2" O.C. @L/480, TL/240.
16" DEEP4X2 METAL PLATE CONNECTED WOOD FLOORTRUSSES.
DIMENSIONS ARE STUD TO STUD FRAMING. (FEET-INCHES-SIXTEENTHS)
ALL BRACING(TEMP. &PERM.) AND BRACINGDESIGN BYOTHERS, SEE PLAN AND BCSI-B7.
ALL CONVENTIONAL FRAMING, BLOCKING, SHEATHING, SHEARHARDWARE AND RELATED CONNECTIONS BYOTHERS.
TRUSS LUMBERIS KD19 SPF AND/ORSP-SYP, AS NEEDED, PEREACH DESIGN FORTHE REQUIRED LOADINGAND DEFLECTION CRITERIA.
(NO TREATED ORFIRE TREATED LUMBERUSED. TRUSSES CANNOT COME INTO DIRECT CONTACT WITH CONCRETE)
BEAMS (DROPPED ORFLUSH AS NOTED) PERPLAN AND SEPARATION SHEATHINGBYOTHERS.
FRAMERTO FIELD VERIFYALL PLUMBING, HVAC, SPRINKLER, ELECTRICAL AND ROOF DRAIN LOCATIONS PRIORTO SETTINGTRUSSES.
PLUMBINGVENT STACKS TO BE FIELD LOCATED IN BETWEEN TRUSSES AND STUDS WHERE POSSIBLE.
TRUSSES CANNOT BE CUT, DRILLED ORNOTCHED. BLOCKINGBETWEEN TRUSSES FORPARALLEL WALLS ABOVE AND BELOW BYBLDR.
FRAMERTO SOLID BLOCK ALL POINT LOADS TO THE FOUNDATION.
2X6 TOPEND OF TRUSS RIBBON BRACINGBYOTHERS. 2X6 STRONGBACK BRACING@10' O.C. MAX. BYOTHERS.
CHATHAM2CHATHAM2
HARDWARE
2 - HUC26-2
33 - THA422
RITTENHOUSE 1
PLUMBINGWALL
THA422 THA422THA422
THA422
THA422
THA422THA422
THA422PLUMBINGWALL
THA422 THA422THA422
THA422
THA422
THA422THA422
THA422PLUMBINGWALL
HUC26-2
THA422
THA422
THA422THA422
THA422
HUC26-2DBL. 2X6
BBO
PRELIMINARYBLDG. B
FG18
FG16 FG20FG21FG17
FG15
FG19FGE04FG18
FG16 FG20FG21FG17
FG15
FG19FGE04FG23
FG22
FG26FG24 FG27F14
F13FGE05
F09(2)F09(9)F13(4)F12(2)F10(3)F11(2)F09(2)F09(9)F13(4)F12(2)F10(3)F11(2)F09(12)F09(6)F12(5) 24-00-0024-00-00
4-004-0024-00-00 5-03-0017-11-0813-10-00 8-00-00 4-01-08 7-10-043-04-00 8-00-00 5-11-081-02-008-00-00 3-06-005-03-0017-11-0813-10-004-01-08 3-04-00
5-11-081-02-003-06-009-00-08 11-00-002-10-083-04-00
72-08-00
37-00-0037-00-0024-00-00
4-0024-00-00 4-0024-00-00
2-00-002-00-002-00-00 2-00-00 IRC 2018TPI 2014 40TCLL - 20TCDL - 10BCDL ONYX +EAST, LLC.UPTOWN WEST CLAY BUILDINGB, 3RD FLOOR1/4"=1' March28, 2021JSG B21100774ACUSTOMER:PROJECT: LOCATION: JOB #:DATE:DESIGNER: DESIGN INFORMATION: SCALE:9028 OldSR67 SouthMooresville, IN 46158(317) 834-5380
Truss Placement Guide
1) This layout is intended for the purpose of truss location
and placement only. Refer to the building plans for actual
building construction.
2) All dimensions shown 00-00-00 are in feet-inches-sixteenths.
3) Trusses are spaced 24" on center unless otherwise noted.
4) Do not cut or modify trusses.
5) Refer to the individual truss design drawings for the location
of member bracing, uplift and truss end reactions.
6) Installation of all temporary and permanent bracing is
essential. See truss drawings, BCSI-B2 Summary Sheet
and building designer requirements.IIICARMEL, IN. 46032
04/30/21