Loading...
HomeMy WebLinkAboutA0.0 Cover SheetB.WOODS C.L. HELT PROJECT # Sheet Description : Project : Drawn By : Checked By : Revisions : Seal Date : Sheet No. C.L. Helt, Architect Inc. CARMEL, IN 46032 21003 RITA'S INTERIOR UPFIT 110 W MAIN STREET SUITE 127 6405 WILKINSON BLVD SUITE 100 BELMONT, NC 28012 Ph. 704-342-1686 Fx. 704-343-0054 INFO@CLHELT.COM THIS DRAWING AND ITS COPIES ARE THE COPYRIGHT OF C.L. HELT ARCHITECT INC. THIS DRAWING MAY NOT BE USED FOR PROJECTS OTHER THAN THE DESIGNATED PROJECT WITHOUT THE SPECIFIC WRITTEN APPROVAL OF C.L. HELT ARCHITECT INC., AND OR TIMOTHY JOHNSTON, ARCHITECT D.MYERS 02/09/2021 02/15/2021 COVERSHEET SHEET INDEX PROJECT INFO A0 TENANT ARCHITECT C.L. HELT ARCHITECT, INC. 6405 WILKINSON BOULEVARD, SUITE 100 BELMONT, NC 28012 PH: (704) 342-1686 ATTN: BEN WOODS EMAIL: BENW@CLHELT.COM STEVE WILKOS WILKI BOYZ TREATS, LLC 16520 VINTAGE CT N WESTFIELD IN, 46062 PH: (201) 926-0227 ATTN: STEVE WILKOS EMAIL:wilkos908@gmail.com FRANCHISE REPRESENTATIVE RITA'S FRANCHISE COMPANY 1210 NORHTBROOK DRIVE, SUITE 310 TREVOSE, PA 19053 PH: (757) 322-7797 ATTN: JEFF BAKER EMAIL: J.BAKER@RITASCORP.COM ABBREVIATIONS ABV ABOVE AFF ABOVE FINISHED FLOOR A/C AIR CONDITIONING ARCH ARCHITECT(URAL) @ AT BLK BLOCK(ING) BOT BOTTOM BLDG BUILDING CLG CEILING CL CENTERLINE CIRC CIRCUIT CLR CLEAR COL COLUMN CONC CONCRETE CMU CONCRETE MASONRY UNIT CONST CONSTRUCTION CONT CONTINUOUS CTR COUNTER DTL / DET DETAIL DIA DIAMETER DIM DIMENSION DN DOWN DWG DRAWING EA EACH ELEV ELEVATION EQ EQUAL EQPT EQUIPMENT EXIST EXISTING EXP EXPOSED EXT EXTERIOR EIFS EXTERIOR INSUL. FINISH SYSTEM FT ( ' ) FEET, FOOT FIN FINISH(ED) FL FLOOR(ING) FD FLOOR DRAIN FLUR FLUORESCENT FRP FIBERGLASS REINFORCED PANEL FUR FURRED(ING) F.R. FIRE RATED F.E. FIRE EXTINGUISHER GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD HDW HARDWARE HDWD HARDWOOD HVAC HEATING/VENTILATION/ AIR CONDITIONING HM HOLLOW METAL IN ( " ) INCH ID INSIDE DIAMETER INSUL INSULATION INT INTERIOR MANUF MANUFACTURE(R) MFG MANUFACTURE(R) MECH MECHANICAL MIN MINIMUM MISC MISCELLANEOUS MTL METAL M.R. MOISTURE RESISTANT MULL MULLION NIC NOT IN CONTRACT NTS NOT TO SCALE NUM NUMBER OFF OFFICE OC ON CENTER(S) OPN'G OPENING OPH OPPOSITE HAND OD OUTSIDE DIAMETER PNT PAINT(ED) P-LAM PLASTIC LAMINATE PLWD PLYWOOD POL POLISHED PROJ PROJECT PL PLATE RE REFERENCE REF REFRIGERATOR REM REMOVE(D)(ABLE) REQ'D REQUIRED REV REVISION(S), REVISED RM ROOM RO ROUGH OPENING RD ROUND SCH SCHEDULE SEC SECTION SHT SHEET SIM SIMILAR SC SOLID CORE SPEC SPECIFICATION(S) SS STAINLESS STEEL STO STORAGE STRUCT STRUCTURE(AL) SUSP SUSPENDED TEL TELEPHONE TYP TYPICAL THRU THROUGH VCT VINYL COMPOSITE TILE VEST VESTIBULE W/ WITH W/O WITHOUT WD WOOD WDB WOOD BASE ARCHITECTURAL STRUCTURAL - NONE SHEET INDEX A0 A5.0 A3.0 FINISH PLAN & WALL FINISH DIAGRAMS COVER SHEET / SHEET INDEX / PROJECT INFO. A1.1 EQUIPMENT PLAN & SCHEDULE MILLWORK & MOP SINK DETAILS DOOR SCHEDULE, NOTES & DETAILS ARCHITECTURAL SYMBOLS: A0.2 LIFE SAFETY & ACCESSIBILITY PLAN INDICATES SECTION IS MIRRORED INDICATES SECTION IS SIMILAR INDICATES SECTION IS TYPICAL X X SIM. X X DETAIL TAG DETAIL NUMBER ON SHEET SHEET NUMBER ELEVATION TAG DETAIL NUMBER ON SHEET SHEET NUMBER OPP. TYP. X'-X" HEIGHT A.F.F. A0.1 GENERAL REQUIREMENTS AND SPECIFICATIONS A2.0 REFLECTED CEILING PLAN & SCHEDULE PLUMBING P-1 PLUMBING COVERHSEET MECHANICAL M-1 ELECTRICAL E-2 E-1 ELECTRICAL COVERHSEET ELECTRICAL PLANS P-2 MECHANICAL PLAN PLUMBING PLANS E-3 ELECTRICAL SCHEDULE LEGEND WALL TYPE. SEE WINDOW GLAZING ELEVATION ON SHEET A1.0 DOOR TYPE. SEE DOOR SCHEDULE ON SHEET A5.0 FINISH TYPE SEE SHEET A2.0 EQUIPMENT TYPE SEE SHEET A3.0 CLEAR FLOOR SEE SHEET A0.1 TOILET ACCESSORY SEE SHEET A0.1 REVISION MARK XX 000 XXXX XXX XX XX X 110 W MAIN STREET SUITE 127 CARMEL, IN 46032 VICINITY MAP N.T.S. PROJECT LOCATION A2.1 FINISH SCHEDULE & MATERIAL SPECIFICATIONS A1.0 FLOOR PLAN, & NOTES & SCHEDULES J. CORBETT THOMASON, PE 2120 DILWORTH ROAD EAST CHARLOTTE, NC 28203 ATTN: J. CORBETT THOMASON PH: (704) 333-1020 EMAIL: CORBETT@CORBETTENGINEERING.COM PLUMBING/ELECT./MECH. CONSULTANT PROJECT INFORMATION PROJECT INFORMATION SCOPE OF WORK TENANT IMPROVEMENT CONSISTING OF THE CONSTRUCTION OF AN INTERIOR TENANT IMPROVEMENT WITHIN AN EXISTING BUILDING SHELL; EXISTING BUILDING SHELL UNDER A SEPARATE PERMIT. INTERIOR TENANT IMPROVEMENTS TO INCLUDE ALL ELECTRICAL, PLUMBING AND MECHANICAL MODIFICATIONS, INTERIOR PARTITIONS, EQUIPMENT AND STOREFRONT MODIFICATIONS. NO STRUCTURAL MODIFICATIONS ARE PART OF THE SCOPE OF WORK. GOVERNING CODES BUILDING CODE:.................................INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS PLUMBING CODE:...............................INTERNATIONAL PLUMBING CODE 2006 WITH INDIANA AMENDMENTS MECHANICAL CODE:......................... INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS ELECTRICAL CODE:.............................NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS ENERGY CODE:....................................ASHRAE 90.1 2007 WITH INDIANA AMENDMENTS FIRE / LIFE SAFETY CODE:................INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS FUEL & GAS CODE:.............................INTERNATIONALS FUEL & GAS CODE 2012 WITH INDIANA AMENDMENTS ACCESSIBILITY CODE:.........................ICC ANSI A117.1-2017 BUILDING DATA UPFIT SQUARE FOOTAGE - TO BE REVIEWED. 1,148 SF NUMBER OF FLOORS IN BUILDING:.................4 CONSTRUCTION TYPE:.....................................1-A FLOOR(S) OF PROPOSED RENOVATION:.......1 CURRENT OCCUPANCY:................................. B PROPOSED OCCUPANCY:.............................. B ADJACENT OCCUPANCY :............................ M ALLOWABLE AREA (SQ. FT.):.............. 23,000 MIXED OCCUPANCY.................... .............. YES NON-SEPARATED MIXED OCCUPANCY........ NO SEPARATED MIXED OCCUPANCY................. YES OCCUPANT LOAD:............................. SEATING: 4 QUEUING: 7 KITCHEN: 3 TOTAL OCCUPANTS = 14 SEE LIFE SAFETY SHEET A0.1 FIRE RESISTANCE RATING: NUMBER OF EXITS PROVIDED:............ 2 NUMBER OF EXITS REQUIRED:.............1 (14 OCCUPANTS x 0.2" PER PERSON = 2.8") PER ADA REQUIREMENTS - EACH EXIT TO BE 32" OR GREATER EXIT ACCESS - MAXIMUM TRAVEL DISTANCE ALLOWED = 300'-0" EXIT SIGNAGE:..................................... EXIT SIGNAGE TO COMPLY WITH 2012 IBC 1013 INTERIOR FINISHES:.............................. a. INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS TO HAVE A CLASS 'B' FLAME SPREAD CLASSIFICATION (MIN.) b. CORRIDORS & ENCLOSURES FOR EXIT ACCESS STAIRWAYS AND EXIT ACCESS RAMPS TO HAVE A CLASS 'C' FLAME SPREAD CLASSIFICATION (MIN.) c. OTHERS ROOMS & ENCLOSED SPACES TO HAVE A CLASS 'C' FLAME SPREAD CLASSIFICATION (MIN.) PLUMBING FIXTURES:...........................2012 IBC SECTION 2902.2 SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS OCCUPANCIES IN WHICH MAXIMUM OCCUPANT LOAD IS 15 OR FEWER. TABLE 601 IBC 2012 BUILDING ELEMENT FIRE RESISTANCE RATING (HOURS) BUILDING ELEMENT TYPE 1-A PRIMARY STRUCTURAL FRAME 3 BEARING WALLS EXTERIOR 3 INTERIOR 3 NONBEARING WALLS & PARTITIONS EXTERIOR 0 NONBEARING WALLS AND PARTITIONS INTERIOR 0 FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202) 2 ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202) 1-1/2 EXTERIOR STOREFRONT RENOVATION?................. YES PROPOSED STRUCTURAL ALTERATIONS?............... NO ENERGY CALCULATIONS ATTACHED?................... NO TOILET FACILITIES PROVIDED?................................. YES (EXISTING) EXISTING FIRE SPRINKLERS?...................................... YES *FIRE ALARM SYSTEM MODIFICATIONS?................ NO *FIRE SPRINKLER SYSTEM MODIFICATIONS?........... N/A SECTION 2902.2 IBC 2012 FIXTURES, FAUCETS & FIXTURE FITTINGS - SEPARATE FACILITIES OCCUPANCY B: BUSINESS 14 OCCUPANTS CODE - FREE TAP WATER WILL BE PROVIDED TO ALL CUSTOMERS AT THEIR REQUEST REQUIRED PROVIDED WATER CLOSETS 1 1 LAVATORIES 1 1 SERVICE SINK 1 1 TOTAL USABLE SQUARE FOOTAGE:1,148 SF TOTAL OCCUPANCY............................ 14 D1.0 DEMOLITION PLAN FIRE PROTECTION/ALARM SYSTEM THE GENERAL CONTRACTOR IS TO CONTRACT WITH A LICENSED FIRE PROTECTION CONTRACTOR WHO WILL DESIGN THE REARRANGEMENT OF THE SYSTEM, SEAL THE DESIGN AND SUBMIT FOR APPROVAL UNDER SEPARATE COVER TO THE REGULATING AUTHORITIES AS WELL AS ARRANGE INSPECTIONS AND TEST FOR PERMITTING 1 03/10/2021 STATE REVIEW COMMENT 03/10/2021 1 1 05/04/21