HomeMy WebLinkAboutA0.0 Cover SheetB.WOODS
C.L. HELT PROJECT #
Sheet Description : Project :
Drawn By :
Checked By :
Revisions :
Seal
Date :
Sheet No.
C.L. Helt, Architect Inc.
CARMEL, IN 46032
21003
RITA'S
INTERIOR UPFIT
110 W MAIN STREET SUITE 127
6405 WILKINSON BLVD
SUITE 100
BELMONT, NC 28012
Ph. 704-342-1686
Fx. 704-343-0054
INFO@CLHELT.COM
THIS DRAWING AND ITS COPIES ARE THE
COPYRIGHT OF C.L. HELT ARCHITECT INC. THIS
DRAWING MAY NOT BE USED FOR PROJECTS
OTHER THAN THE DESIGNATED PROJECT
WITHOUT THE SPECIFIC WRITTEN APPROVAL
OF C.L. HELT ARCHITECT INC., AND OR
TIMOTHY JOHNSTON, ARCHITECT
D.MYERS
02/09/2021
02/15/2021
COVERSHEET
SHEET INDEX
PROJECT INFO
A0
TENANT
ARCHITECT
C.L. HELT ARCHITECT, INC.
6405 WILKINSON BOULEVARD, SUITE 100
BELMONT, NC 28012
PH: (704) 342-1686
ATTN: BEN WOODS
EMAIL: BENW@CLHELT.COM
STEVE WILKOS
WILKI BOYZ TREATS, LLC
16520 VINTAGE CT N
WESTFIELD IN, 46062
PH: (201) 926-0227
ATTN: STEVE WILKOS
EMAIL:wilkos908@gmail.com
FRANCHISE REPRESENTATIVE
RITA'S FRANCHISE COMPANY
1210 NORHTBROOK DRIVE, SUITE 310
TREVOSE, PA 19053
PH: (757) 322-7797
ATTN: JEFF BAKER
EMAIL: J.BAKER@RITASCORP.COM
ABBREVIATIONS
ABV ABOVE
AFF ABOVE FINISHED FLOOR
A/C AIR CONDITIONING
ARCH ARCHITECT(URAL)
@ AT
BLK BLOCK(ING)
BOT BOTTOM
BLDG BUILDING
CLG CEILING
CL CENTERLINE
CIRC CIRCUIT
CLR CLEAR
COL COLUMN
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCTION
CONT CONTINUOUS
CTR COUNTER
DTL / DET DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DWG DRAWING
EA EACH
ELEV ELEVATION
EQ EQUAL
EQPT EQUIPMENT
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
EIFS EXTERIOR INSUL. FINISH SYSTEM
FT ( ' ) FEET, FOOT
FIN FINISH(ED)
FL FLOOR(ING)
FD FLOOR DRAIN
FLUR FLUORESCENT
FRP FIBERGLASS REINFORCED PANEL
FUR FURRED(ING)
F.R. FIRE RATED
F.E. FIRE EXTINGUISHER
GC GENERAL CONTRACTOR
GWB GYPSUM WALLBOARD
HDW HARDWARE
HDWD HARDWOOD
HVAC HEATING/VENTILATION/
AIR CONDITIONING
HM HOLLOW METAL
IN ( " ) INCH
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
MANUF MANUFACTURE(R)
MFG MANUFACTURE(R)
MECH MECHANICAL
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
M.R. MOISTURE RESISTANT
MULL MULLION
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NUM NUMBER
OFF OFFICE
OC ON CENTER(S)
OPN'G OPENING
OPH OPPOSITE HAND
OD OUTSIDE DIAMETER
PNT PAINT(ED)
P-LAM PLASTIC LAMINATE
PLWD PLYWOOD
POL POLISHED
PROJ PROJECT
PL PLATE
RE REFERENCE
REF REFRIGERATOR
REM REMOVE(D)(ABLE)
REQ'D REQUIRED
REV REVISION(S), REVISED
RM ROOM
RO ROUGH OPENING
RD ROUND
SCH SCHEDULE
SEC SECTION
SHT SHEET
SIM SIMILAR
SC SOLID CORE
SPEC SPECIFICATION(S)
SS STAINLESS STEEL
STO STORAGE
STRUCT STRUCTURE(AL)
SUSP SUSPENDED
TEL TELEPHONE
TYP TYPICAL
THRU THROUGH
VCT VINYL COMPOSITE TILE
VEST VESTIBULE
W/ WITH
W/O WITHOUT
WD WOOD
WDB WOOD BASE
ARCHITECTURAL
STRUCTURAL - NONE
SHEET INDEX
A0
A5.0
A3.0
FINISH PLAN & WALL FINISH DIAGRAMS
COVER SHEET / SHEET INDEX / PROJECT INFO.
A1.1
EQUIPMENT PLAN & SCHEDULE
MILLWORK & MOP SINK DETAILS DOOR SCHEDULE, NOTES & DETAILS
ARCHITECTURAL SYMBOLS:
A0.2
LIFE SAFETY & ACCESSIBILITY PLAN
INDICATES SECTION IS MIRRORED
INDICATES SECTION IS SIMILAR
INDICATES SECTION IS TYPICAL
X
X
SIM.
X
X
DETAIL TAG
DETAIL NUMBER ON SHEET
SHEET NUMBER
ELEVATION TAG
DETAIL NUMBER ON SHEET
SHEET NUMBER
OPP.
TYP.
X'-X" HEIGHT A.F.F.
A0.1
GENERAL REQUIREMENTS AND SPECIFICATIONS
A2.0
REFLECTED CEILING PLAN & SCHEDULE
PLUMBING
P-1 PLUMBING COVERHSEET
MECHANICAL
M-1
ELECTRICAL
E-2
E-1 ELECTRICAL COVERHSEET
ELECTRICAL PLANS
P-2
MECHANICAL PLAN
PLUMBING PLANS
E-3 ELECTRICAL SCHEDULE
LEGEND
WALL TYPE. SEE WINDOW GLAZING ELEVATION ON SHEET A1.0
DOOR TYPE. SEE DOOR SCHEDULE ON SHEET A5.0
FINISH TYPE SEE SHEET A2.0
EQUIPMENT TYPE SEE SHEET A3.0
CLEAR FLOOR SEE SHEET A0.1
TOILET ACCESSORY SEE SHEET A0.1
REVISION MARK
XX
000
XXXX
XXX
XX
XX
X
110 W MAIN STREET SUITE 127
CARMEL, IN 46032
VICINITY MAP N.T.S.
PROJECT LOCATION
A2.1 FINISH SCHEDULE & MATERIAL SPECIFICATIONS
A1.0 FLOOR PLAN, & NOTES & SCHEDULES
J. CORBETT THOMASON, PE
2120 DILWORTH ROAD EAST
CHARLOTTE, NC 28203
ATTN: J. CORBETT THOMASON
PH: (704) 333-1020
EMAIL: CORBETT@CORBETTENGINEERING.COM
PLUMBING/ELECT./MECH. CONSULTANT
PROJECT INFORMATION
PROJECT INFORMATION
SCOPE OF WORK
TENANT IMPROVEMENT CONSISTING OF THE CONSTRUCTION OF AN INTERIOR TENANT IMPROVEMENT WITHIN AN
EXISTING BUILDING SHELL; EXISTING BUILDING SHELL UNDER A SEPARATE PERMIT. INTERIOR TENANT IMPROVEMENTS
TO INCLUDE ALL ELECTRICAL, PLUMBING AND MECHANICAL MODIFICATIONS, INTERIOR PARTITIONS, EQUIPMENT AND
STOREFRONT MODIFICATIONS. NO STRUCTURAL MODIFICATIONS ARE PART OF THE SCOPE OF WORK.
GOVERNING CODES
BUILDING CODE:.................................INTERNATIONAL BUILDING CODE 2012 WITH INDIANA AMENDMENTS
PLUMBING CODE:...............................INTERNATIONAL PLUMBING CODE 2006 WITH INDIANA AMENDMENTS
MECHANICAL CODE:......................... INTERNATIONAL MECHANICAL CODE 2012 WITH INDIANA AMENDMENTS
ELECTRICAL CODE:.............................NATIONAL ELECTRICAL CODE 2008 WITH INDIANA AMENDMENTS
ENERGY CODE:....................................ASHRAE 90.1 2007 WITH INDIANA AMENDMENTS
FIRE / LIFE SAFETY CODE:................INTERNATIONAL FIRE CODE 2012 WITH INDIANA AMENDMENTS
FUEL & GAS CODE:.............................INTERNATIONALS FUEL & GAS CODE 2012 WITH INDIANA AMENDMENTS
ACCESSIBILITY CODE:.........................ICC ANSI A117.1-2017
BUILDING DATA
UPFIT SQUARE FOOTAGE - TO BE REVIEWED. 1,148 SF
NUMBER OF FLOORS IN BUILDING:.................4
CONSTRUCTION TYPE:.....................................1-A
FLOOR(S) OF PROPOSED RENOVATION:.......1
CURRENT OCCUPANCY:................................. B
PROPOSED OCCUPANCY:.............................. B
ADJACENT OCCUPANCY :............................ M
ALLOWABLE AREA (SQ. FT.):.............. 23,000
MIXED OCCUPANCY.................... .............. YES
NON-SEPARATED MIXED OCCUPANCY........ NO
SEPARATED MIXED OCCUPANCY................. YES
OCCUPANT LOAD:............................. SEATING: 4
QUEUING: 7
KITCHEN: 3
TOTAL OCCUPANTS = 14
SEE LIFE SAFETY SHEET A0.1
FIRE RESISTANCE RATING:
NUMBER OF EXITS PROVIDED:............ 2
NUMBER OF EXITS REQUIRED:.............1 (14 OCCUPANTS x 0.2" PER PERSON = 2.8")
PER ADA REQUIREMENTS - EACH EXIT TO BE 32" OR GREATER
EXIT ACCESS - MAXIMUM TRAVEL DISTANCE ALLOWED = 300'-0"
EXIT SIGNAGE:..................................... EXIT SIGNAGE TO COMPLY WITH 2012 IBC 1013
INTERIOR FINISHES:.............................. a. INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS
TO HAVE A CLASS 'B' FLAME SPREAD CLASSIFICATION (MIN.)
b. CORRIDORS & ENCLOSURES FOR EXIT ACCESS STAIRWAYS AND EXIT ACCESS
RAMPS TO HAVE A CLASS 'C' FLAME SPREAD CLASSIFICATION (MIN.)
c. OTHERS ROOMS & ENCLOSED SPACES TO HAVE A CLASS 'C' FLAME SPREAD
CLASSIFICATION (MIN.)
PLUMBING FIXTURES:...........................2012 IBC SECTION 2902.2 SEPARATE FACILITIES SHALL NOT BE REQUIRED IN
BUSINESS OCCUPANCIES IN WHICH MAXIMUM OCCUPANT LOAD IS 15 OR FEWER.
TABLE 601 IBC 2012
BUILDING ELEMENT FIRE RESISTANCE RATING
(HOURS)
BUILDING ELEMENT
TYPE
1-A
PRIMARY STRUCTURAL FRAME 3
BEARING WALLS
EXTERIOR 3
INTERIOR 3
NONBEARING WALLS & PARTITIONS
EXTERIOR 0
NONBEARING WALLS AND PARTITIONS
INTERIOR 0
FLOOR CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS (SEE SECTION 202)
2
ROOF CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS (SEE SECTION 202)
1-1/2
EXTERIOR STOREFRONT RENOVATION?................. YES
PROPOSED STRUCTURAL ALTERATIONS?............... NO
ENERGY CALCULATIONS ATTACHED?................... NO
TOILET FACILITIES PROVIDED?................................. YES (EXISTING)
EXISTING FIRE SPRINKLERS?...................................... YES
*FIRE ALARM SYSTEM MODIFICATIONS?................ NO
*FIRE SPRINKLER SYSTEM MODIFICATIONS?........... N/A
SECTION 2902.2 IBC 2012
FIXTURES, FAUCETS & FIXTURE FITTINGS - SEPARATE FACILITIES
OCCUPANCY
B: BUSINESS
14 OCCUPANTS
CODE - FREE TAP WATER WILL BE
PROVIDED TO ALL CUSTOMERS AT
THEIR REQUEST
REQUIRED PROVIDED
WATER CLOSETS 1 1
LAVATORIES 1 1
SERVICE SINK 1 1
TOTAL USABLE SQUARE FOOTAGE:1,148 SF
TOTAL OCCUPANCY............................ 14
D1.0 DEMOLITION PLAN
FIRE PROTECTION/ALARM SYSTEM
THE GENERAL CONTRACTOR IS TO CONTRACT
WITH A LICENSED FIRE PROTECTION
CONTRACTOR WHO WILL DESIGN THE
REARRANGEMENT OF THE SYSTEM, SEAL THE
DESIGN AND SUBMIT FOR APPROVAL UNDER
SEPARATE COVER TO THE REGULATING
AUTHORITIES AS WELL AS ARRANGE
INSPECTIONS AND TEST FOR PERMITTING
1 03/10/2021 STATE REVIEW COMMENT
03/10/2021
1
1
05/04/21