HomeMy WebLinkAboutA0.1 Life Safety and AccessibilityE1
ADJACENT TENANT NIC
"VACANT"
ADJACENT TENANT NIC
"CARRIE HOLLE GROUP"
OPEN TO
COURTYARD
4"
O/C
FROM
WALL
Chit Rails
FUTURE
UTILITIES
ONLY
SUOERTIV ANIHC
-K8271 _CROTAVAL KAEPASEHCYE
FRONT OF
BUILDING
BOH 101 AREA
RESTROOM EXISTING 102
grease trap
100
E2
101
SEATING 100 AREA
3
"
TYP.
3"
EXCEPT WHEN SIGN IS ON DOOR, THE
MOUNTING LOCATION SHALL BE SUCH
THAT A PERSON CAN APPROACH TO
WITHIN 3" OF THE SIGN WITHOUT
ENCOUNTERING ANY PROTRUDING
OBJECTS OR HAVING TO STAND WITHIN
THE SWING OF A DOOR
SIGN(S)
IF NO WALL SPACE ADJACENT TO THE
STRIKE JAMB IS AVAILABLE, THEN THE
SIGN(S) SHALL BE PLACED ON THE
NEAREST ADJACENT WALL OR PARTITION
HINGE JAMB
STRIKE JAMB
SIGN(S) DESIGNATING PERMANENT
ROOMS AND SPACES SHALL BE LOCATED
ADJACENT TO THE STRIKE JAMB / LATCH
SIDE OF THE DOOR
ROOM / SPACE ID SIGN
ROOM / SPACE ID SIGN
IF THE ADJACENT WALL / PARTITION
SPACE CANNOT ACCOMMODATE THE
PHYSICAL SIZE OF THE SIGN, THEN IT
SHALL BE CENTERED ON THE DOOR FACE
AT A HEIGHT OF 60" TO THE CENTERLINE
OF THE SIGN
TYPICAL INTERIOR SIGN PLACEMENT
--THE FOLLOWING ELEMENTS AND SPACES OF
ACCESSIBLE BUILDINGS SHALL BE IDENTIFIED BY THE
INTERNATIONAL SYMBOL ACCESSIBILITY.
-EXIT SIGNS SHALL COMPLY WITH IBC 1011.
-SAFETY DEVICES DESIGNED AND INTENDED FOR
PUBLIC USE (E.G., FIRE ALARM PULL STATIONS,
MANUAL MECHANISMS ACTIVATION EMERGENCY
SIGNALING DEVICES, FIRE EXTINGUISHERS, ETC.)
SHALL BE IDENTIFIED WITH SIGNAGE COMPLYING WITH
ALL NUMBERED NOTES (THIS SHEET)
-SIGNS IDENTIFYING TOILETS SHALL USE THE WORDS
"MEN" AND "WOMEN" OR "MEN'S TOILET" AND
"WOMEN'S TOILET" ONLY. MALE AND FEMALE
CARICATURES (I.E., PICTOGRAMS) SHALL ALSO BE
PROVIDED.
-IF PICTOGRAMS ARE PROVIDED, THEN THEY SHALL BE
ACCOMPANIED BY THE EQUIVALENT VERBAL
DESCRIPTION PLACED DIRECTLY BELOW THE
PICTOGRAM. THE PICTOGRAM BORDER DIMENSION
(THE UNOBSTRUCTED FIELD WITHIN WHICH IT IS
LOCATED) SHALL BE 6" MIN.
1. 6" MIN. BORDER DIMENSION- MALE/FEMALE
FIGURES.
2. USE OF MALE/FEMALE CHARACTERS IS REQUIRED
3. LETTERS AND NUMBERS SHALL BE RAISED
1
32"
FROM THE BACKGROUND ON WHICH THEY ARE
MOUNTED AND SHALL BE
5
8" MIN. TO 2" MAX. IN
HEIGHT. LETTERS SHALL BE CAPITAL LETTERS
ONLY. LETTERS AND NUMERALS SHALL HAVE
SHARPLY DEFINED EDGES AND MAY BE EITHER
SANS SERIF OR SIMPLE SERIF.
4. ALPHABETIC / NUMERIC SIGNAGE SHALL BE
ACCOMPANIED BY GRADE 2 BRAILLE.
5. LETTERS SHALL HAVE A WIDTH-TO -HEIGHT RATIO
BETWEEN 3:5 AND 1:1. STROKE-WIDTH-TO-HEIGHT
RATIO SHALL BE BETWEEN 1:5 AND 1:10.
6. ALL SIGNS SHALL HAVE LETTERS, NUMERALS,
CHARACTERS AND THE BACKGROUND ON WHICH
THEY ARE LOCATED IN AN EGGSHELL (SEMI-MATTE),
MATTE (FLAT), OR OTHER NON-GLARE FINISH ONLY.
CHARACTERS AND SYMBOLS SHALL CONTRAST
WITH THE BACKGROUND ON WHICH THEY ARE
MOUNTED EITHER BY HAVING LIGHT CHARACTERS
ON A DARK BACKGROUND OR DARK CHARACTERS
ON A LIGHT BACKGROUND.
7. EXIT SIGNS AT EXIT DOORS SHALL INCLUDE RAISED
BRAILLE IN ACCORDANCE WITH ADA STANDARDS
FOR ACCESSIBILITY DESIGN SECTION 703 AND 704
AND FOLLOW LOCAL AND STATE CODES. MOUNT
PER INTERIOR SIGN HEIGHT NOTES.
8. PROVIDE SIGNAGE INDICATING BABY CHANGING
STATION AT TOILET ROOM W/BABY CHANGING
STATION.
60"
60"
TYPICAL INTERIOR SIGN HEIGHT
1
23
TYPICAL 5 INTERIOR SIGN NOTES 4 8 6
RESTROOM
36"
20"
ACCESSIBLE
WATER CLOSET
ACCESSIBLE
LAVATORY & MIRROR
ACCESSIBLE
WATER CLOSET
17"
35"
CL 12"
18"
MIN.
40"
40"
42" 9"C L
9"
6"
27" CLR.
29"
34"
8"
17"
MAX.
34"
40"
TOILET ACCESSORY NOTES:
1. GENERAL CONTRACTOR TO CONFIRM EXISTING RESTROOM AND ALL EXISTING TOILET ROOM ACCESSORIES ARE ADA COMPLIANT.
2. MANUFACTURERS INDICATED FOR ITEMS NOTED ARE LISTED TO ESTABLISH A BASIS OF DESIGN, EQUAL MANUFACTURERS
ACCEPTABLE.
3. SEE ELECTRICAL DRAWINGS FOR LIGHTING INFORMATION AND SPECIFICATIONS.
4. ALL ACCESSORY FINISHES SHALL BE SELECTED BY THE OWNER.
5. GENERAL CONTRACTOR TO CONFIRM ADA COMPLIANT UNDER SINK PIPE INSULATION ON ALL ADA COMPLIANT SINKS WHERE UNDER
SINK PIPING IS EXPOSED.
REBMUNLEDOMLAIRETAMTCUDORPEMANEDART
16-18"
CL
MIN.
1-1/2"
FINISH
FLOOR
ADA REQUIREMENTS
48"
FIRE
EXTINGUISHER
AND FIRE
EXTINGUISHER
CABINET
E
I
R
E
H
S
I
U
N
G
X
T
I
F
R
E
HAND DRYER/
PAPER TOWEL
C L DISPENSER
48" TO
OPERATING MECH.
SOAP
DISPENSER
12"
MIN
B.O.
REFLECTIVE
SURFACE
30"
BABY
CHANGING
STATION
LAV. WITH CARRIER
BLOCKING AROUND
ENTIRE TOILET
ROOM TO 60" AFF
NOTE 6
NOTE 5CL 15"
MIN
ERTIV SU ANIHC O
-K8271 _CEKAEPASEHCYROTAVAL
RESTROOM EXISTING 102
E2
6'-10"
EXISTING CLEAR
7'-23
4"
EXISTING CLEAR
1'-0"
CLR
17" to 18" FROM
FINISH TO ℄ OF TOILET
15" MIN. G.C. TO
CONFIRM
LAVATORY DOES
NOT OVERLAP
TOILET CLEAR
FLOOR
1'-6"
CLR
B.WOODS
C.L. HELT PROJECT #
Sheet Description : Project :
Drawn By :
Checked By :
Revisions :
Seal
Date :
Sheet No.
C.L. Helt, Architect Inc.
CARMEL, IN 46032
21003
RITA'S
INTERIOR UPFIT
110 W MAIN STREET SUITE 127
6405 WILKINSON BLVD
SUITE 100
BELMONT, NC 28012
Ph. 704-342-1686
Fx. 704-343-0054
INFO@CLHELT.COM
DRAWING COPYRIGHT OF OTHER WITHOUT TIMOTHY THIS C.DRAWING L. HELT THAN JOHNSTON, THE MAY OF ARCHITECT THE SPECIFIC NOT AND C.L. DESIGNATED BE HELT ITS ARCHITECT USED COPIES WRITTEN INC.ARCHITECT
FOR , AND PROJECT ARE APPROVAL PROJECTS OR THE INC. THIS
D.MYERS
02/09/2021
02/15/2021
LIFE SAFETY &
ACCESSIBILTY PLAN
A0.1
1. CONTRACTOR TO FIELD VERIFY THE PRESENCE OF A DUCT
SMOKE DETECTOR & THAT IT IS IN COMPLIANCE WITH
MECHANICAL SECTION 606 AND NFPA 90A.
2. REQUIRED 'PRELIMINARY SMOKE / LIFE SAFETY SYSTEM
TEST. G.C. TO COORDINATE EXECUTION WITH HVAC
SUB-CONTRACTOR PRIOR TO CONTACTING AND
SCHEDULING FINAL SMOKE TEST WITH THE CITY.
3. FIRE EXTINGUISHERS SHALL BE PER NFPA 10, SECTION
3-2.1, AND SHALL BE CONFIRMED WITH THE LOCAL FIRE
MARSHAL.
4. ALL EXIT WAYS SHALL BE KEPT FREE AND CLEAR FOR
EXITING AND ENTERING PURPOSES.
5. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHT &
EXIT SIGN LOCATIONS AND SPECIFICATIONS.
6. PROJECT HAS A FULL ACCESSIBLE MAIN ENTRY AT
GROUND LEVEL.
7. MAX. HEIGHT FOR ALL ACCESSIBLE COUNTERS SHALL BE
36" A.F.F.
TYPE ABC FIRE EXTINGUISHERS MIN. (WITHIN 75' OF TRAVEL)
MOUNT EXTINGUISHER AT 48" AFF TO OPERATING MECHANISM.
EXTINGUISHER TO BE 10 LB "ABC" OR MIN REQUIRED BY FIRE MARSHAL.
MIN. RATING OF A PORTABLE F.E. IS 4A40BC. FINAL NUMBER AND LOCATION
TO BE APPROVED BY FIRE MARSHALL.
G.C. TO PROVIDE FIRE EXTINGUISHERS. MINIMUM (2)
* FE
LIFE SAFETY & ADA NOTES
ACCESSIBLE SEAT
REQUIREMENTS
NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
TABLE 1108.2.2.1
NUMBER OF SEATS
MINIMUM NUMBER OF REQUIRED
WHEELCHAIR SPACES
4 TO 25 1
26 TO 50 2
51 TO 150 4
NUMBER OF SEATS PROVIDED
MINIMUM NUMBER OF REQUIRED
WHEELCHAIR SPACES
4 1
TOTAL OCCUPANCY = 14
1 LIFE SAFETY & ACCESSIBILITY PLAN
A-0.1
SCALE: 1/4" = 1'-0"
TRAVEL DISTANCE =87'-0"
WALL TYPE LEGEND
EXISTING WALL / PARTITION TO REMAIN
NOT USED
NOT USED
NEW INTERIOR PARTITION
HEADER / WALL ABOVE
EXISTING GLASS
CLEAR FLOOR NOTES
30X 48 CLEAR FLOOR AT LAVATORY
30 X 48 CLEAR FLOOR
60 X 56 CLEAR FLOOR AT TOILET
60 Ø TURNING CLEARANCE
54 X 60 AT PULL SIDE OF DOOR (FRONT APPROACH)
48 X 48 AT PUSH SIDE OF DOOR (FRONT APPROACH)
1
2
3
4
5
6
OCCUPANTS
KITCHEN AREA
200 SF. GROSS PER PERSON
AREA:692 SF.
OCCUPANT LOAD: 3
NEW EXIT DOOR (100)
EXIT WIDTH= 34"
MAX. OCCUPANT LOAD CAPACITY = 170
ACTUAL OCCUPANT LOAD = 7
PANIC HARDWARE = NO
EXISTING EXIT DOOR (E1)
EXIT WIDTH= 34"
MAX. OCCUPANT LOAD CAPACITY = 170
ACTUAL OCCUPANT LOAD = 7
PANIC HARDWARE = YES
HATCHING LEGEND
HATCHED AREA REPRESENTS BAR SEATING AREA
(TABLES & CHAIRS UNCONCENTRATED) 4 OCCUPANTS
HATCHED AREA REPRESENTS QUEUING AREA 7 OCCUPANTS
HATCHED AREA REPRESENTS 3 OCCUPANTS
BACK OF HOUSE AREA
HATCHED AREA REPRESENTS EGRESS AREA 0 OCCUPANTS
TO REMAIN OPEN
TOTAL OCCUPANTS:
14 OCCUPANTS
OCCUPANTS
SEATING AREA
15 SF PER PERSON
AREA: 54 SF.
OCCUPANT LOAD:4
OCCUPANTS
QUEUING AREA
5 NET
AREA: 35 SF.
OCCUPANT LOAD:7
2 EXISTING TOILET ROOM PLAN
A0.1
SCALE: 1/2" = 1'-0"
3862'-4
1
2
"
TRAVEL DISTANCE =61'-0"
79'-8
1
2
" > 1/2 DIAGONAL (40'-2
13
16")
1
A0.1
2
2
3
5
4
6
6 5
* FE
* FE
* FE
1 03/10/2021 CLIENT REVIEW COMMENT
03/10/2021
1
05/04/21