C.L. Helt, Architect Inc.
CARMEL, IN 46032
21003
RITA'S
INTERIOR UPFIT
110 W MAIN STREET SUITE 127
6405 WILKINSON BLVD
SUITE 100
BELMONT, NC 28012
Ph. 704-342-1686
Fx. 704-343-0054
INFO@CLHELT.COM
DRAWING COPYRIGHT OF OTHER WITHOUT TIMOTHY THIS C.DRAWING L. THAN HELT JOHNSTON, THE MAY OF ARCHITECT THE SPECIFIC NOT AND C.L. DESIGNATED BE HELT ITS ARCHITECT USED COPIES WRITTEN INC.ARCHITECT
FOR , AND PROJECT ARE APPROVAL PROJECTS OR THE INC. THIS
D.MYERS
02/09/2021
02/15/2021
REFLECTED CEILING PLAN,
NOTES & SCHEDULES
A1.1
1 REFLECTED CEILING PLAN
A-1.1
SCALE: 1/4" = 1'-0"
SYMBOL DESCRIPTION REMARKS
RECESSED LED DOWNLIGHT
SIZE: 6"
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
SURFACE MOUNTED TRACK LIGHT
(DIM: 96" L AND/OR 48"L)
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
24X48 AND/OR 24X24 RECESSED LED
TROFFER W/ ACRYLIC LENS
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
LED EMERGENCY 2 HEADED UNIT - WALL
MOUNT
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
LED EXIT SIGN
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
LED EXIT COMBO
LIGHTING PACKAGE BY KB LIGHTING.
CONTACT: BEN KESSEL 215-953-6663
bkessel@kblighting.com
REFER TO ELECTRICAL DRAWINGS
MECHANICAL DIFFUSERS REFER TO MECHANICAL DRAWINGS
EXIT
2 SOFFIT FRAMING DETAIL
A-1.1
SCALE: 1/2" = 1'-0"
A-1.1
2
3 LAY-IN CEILING DETAIL
A-1.1
SCALE: 1/2" = 1'-0"
REAR OF BUILDING
LEGEND
WALL TYPE SEE SHEET A1.0
DOOR TYPE. SEE DOOR SCHEDULE ON SHEET A5.0
FINISH TYPE SEE SHEET A2.0
EQUIPMENT TYPE SEE SHEET A3.0
CLEAR FLOOR SEE SHEET A0.1
TOILET ACCESSORY SEE SHEET A0.1
XX
000
XXXX
XXX
XX
XX
REFLECTED CEILING FIXTURE LEGEND
(SEE A2.1 FOR CEILING TYPE)
1 03/10/2021 CLIENT REVIEW COMMENT
03/10/2021
1
ADJACENT TENANT NIC
"VACANT"
ADJACENT TENANT NIC
"CARRIE HOLLE GROUP"
OPEN TO
COURTYARD
SUOERTIV ANIHC
-K8271 _CEKAEPASEHCYROTAVAL
FRONT OF
BUILDING
BOH 101 AREA
RESTROOM EX1IS0T2ING
±
2'-6" 4'-11" V.I.F.
TYP.
CT-01
10'-0" AFF
CT-01
9'-0" AFF
CT-02
10'-0" AFF
CT-02
10'-0" AFF
CT-02
9'-0" AFF
±38'-3" V.I.F.
G.C. TO ADJUST CEILING HEIGHT AS REQUIRED
WITH EXISTING STRUCTURE AND DUCTWORK FROM THIS POINT TO REAR OF SPACE
GYP. SOFFIT
8'-0" AFF
EXISTING SOFFIT
10'-5" AFF
EXISTING SOFFIT
10'-1" AFF
2'-0"
TYP.
1'-01
2"
EQ. EQ.
SEE RCP SEATING 100 AREA
SCHEDULED CEILING
SEE REFLECTED
CEILING PLAN
3 5/8" DIAGONAL
BRACING, 48" O.C.
1/2" GYPSUM BOARD ON CONT.
1-5/8"X 3 5/8" 20 GA. MTL.
FRAMING @ 16" O.C. TYP.
U.N.O.
CONT. 20
GA
TRACK
2-#10 SCREWS TYP.
EACH CONNECTION POINT
3-5/8" X20 GA BETWEEN JOISTS W/ 2-#10 SCREWS
INTO EA. STUD. PROVIDE END TRACK
WITH 2 HILTI HDI-P MAX. 3/4" EMBEDMENT @ 24" O.C.
INTO EXISTING CONCRETE STRUCTURE
3 5/8" DIAGONAL
BRACING, 48" O.C.
2-#10 SCREWS TYP. EACH
CONNECTION POINT
12 GAUGE VERTICAL
HANGER W/ CLIPS FROM
STRUCT. ABOVE INSTALL
HANGERS @ 4'-0" O.C.
SCHEDULED CEILING
SEE REFLECTED
CEILING PLAN
3-5/8" X20 GA @ 16" TYP.
O.C. WITH 2 HILTI HDI-P
MAX. 3/4" EMBEDMENT @
24" O.C. INTO EXISTING
CONCRETE STRUCTURE
EXISTING STRUCTURE EXISTING STRUCTURE
12 GAUGE VERTICAL
HANGERS W/ CLIPS FROM
STRUCT. ABOVE INSTALL
HANGERS TO MEET ALL
SEISMIC & LOADING
REQUIREMENTS.
45°
45°
45°
45°
HEAVY DUTY DIRECT
HUNG DRYWALL GRID
SYSTEM WITH WALL
TRACKS
CEILING AS OCCURS.
SEE RCP FOR HEIGHT
AND TYPE (TYP.)
3 TURNS MIN. IN 1-1/2"
(TYP.)
12 GAUGE VERTICAL
HANGER @ 4'-0" O.C.
CROSS RUNNER
3 TURNS MIN. IN
1-1/2" (TYP.)
SEISMIC LOCKING PIN
MAIN RUNNER
NOTE:
1. METAL SUSPENSION SYSTEM FOR ACOUSTICAL TILE AND LAY-IN
PANEL CEILINGS SHALL CONFORM TO THE REQUIREMENTS OF
ASTM C635-87 FOR INTERMEDIATE DUTY SYSTEMS.
2. INSTALLATION OF METAL CEILING SUSPENSION SYSTEM FOR
ACOUSTICAL TILE AND LAY-IN PANELS SHALL CONFORM TO THE
REQUIREMENT OF ASTM C636-86.
3. MAIN RUNNERS AT 2'-0" O.C. CROSS RUNNERS AT 2'-0"/4'-0" O.C.
4. VERTICAL HANGERS TO BE MAX. 8" FROM WALLS