HomeMy WebLinkAboutA5.0 Millwork and Mop Sink DetailsB.WOODS
C.L. HELT PROJECT #
Sheet Description : Project :
Drawn By :
Checked By :
Revisions :
Seal
Date :
Sheet No.
C.L. Helt, Architect Inc.
CARMEL, IN 46032
21003
RITA'S
INTERIOR UPFIT
110 W MAIN STREET SUITE 127
6405 WILKINSON BLVD
SUITE 100
BELMONT, NC 28012
Ph. 704-342-1686
Fx. 704-343-0054
INFO@CLHELT.COM
THIS DRAWING AND ITS COPIES ARE THE
COPYRIGHT OF C.L. HELT ARCHITECT INC. THIS
DRAWING MAY NOT BE USED FOR PROJECTS
OTHER THAN THE DESIGNATED PROJECT
WITHOUT THE SPECIFIC WRITTEN APPROVAL
OF C.L. HELT ARCHITECT INC., AND OR
TIMOTHY JOHNSTON, ARCHITECT
D.MYERS
02/09/2021
02/15/2021
MILLWORK & MOP SINK
DETAILS, DOOR SCHEDULE,
NOTES, & DETAILS
A5.0
3'-0"
1 ENLARGED SERVICE COUNTER
A-5
SCALE: 1/2" = 1'-0"
2 MILLWORK SECTION
A-5
SCALE: 1-1/2" = 1'-0"
3 MILLWORK SECTION
A-5
SCALE: 1-1/2" = 1'-0"
DOOR # ROOM STYLE DIMENSION
DOOR FRAME
HARDWARE
HEAD
DETAIL
JAMB
DETAIL
THRESHOLD
DETAIL
NOTES REMARKS
THICKNESS MATERIAL FINISH MATERIAL FINISH
100 STOREFRONT DOOR C 3'-0" x 8'-0" MANUF.
ALUMINUM
AND
GLASS
MATCH
EXISTING
ALUMINUM
MATCH
EXISTING
SEE HW SET 1 MANUF. MANUF. MANUF. 2,3,8 SEE HW SET 1
E1 (E) REAR DOOR --- --- --- --- --- --- --- --- --- --- --- 1,4,6,7 SEE NOTES
E2 (E) RESTROOM DOOR --- --- --- --- PAINT --- --- --- --- --- --- 1,4,6,7,9 SEE NOTES
101 BOH AREA A 3'-0" x 7'-0" MANUF. ALUMINUM SS MANUF. MANUF. MANUF. 7 6 5 4,5,7 SINGLE ACTION DOOR
DOOR & FRAME SCHEDULE
E = EXISTING HC = HOLLOW CORE WOOD SCWD = SOLID CORE WOOD HM = HOLLOW METAL CW = COMPOSITE WOOD LAM = LAMINATE SS = STAINLESS STEEL
MANUF = MANUFACTURER
LEGEND
NOTES
1. EXISTING TO REMAIN
2. NEW STOREFRONT ENTRY DOOR TO MATCH EXISTING BUILDING FINISH AND COLOR.
3. G.C. IS RESPONSIBLE FOR INSTALLING STOREFRONT DOOR AND HARDWARE.
4. ELIASON CORP LWP SWING DOOR -. - 36" OPENING WIDTH FOR DOOR.
5. G.C. IS RESPONSIBLE FOR INSTALLING ELIASON DOOR AND HARDWARE.
6. ALL EXTERIOR DOORS & TOILET ROOM(INCLUDING EXISTING) SHALL BE SELF-CLOSING AND RODENT PROOF.
IF A CLOSER DOES NOT EXIST G.C. IS TO PROVIDE AND INSTALL ONE.
7. PER 1010.1.9.3: DOOR 'E1' SHALL HAVE LOCKING DEVICE THAT IS READILY DISTINGUISHABLE AS LOCKED, AND
PROVIDE WITH A KEY THAT CANNOT BE REMOVED FROM THE EGRESS SIDE. DOOR 'E1' SHALL BE READILY
DISTINGUISHABLE AS LOCKED WITH A SIGN STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS
OCCUPIED". THE USE OF THE KEY-OPERATED LOCKING DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR
VIOLATIONS OF SECTION 1010.1.9.3.
8. DOOR TO MEET ADA DOOR OPENING PRESSURE GUIDELINES, MAX 5 LBS (INTERIOR) & 10-15 LBS (EXTERIOR)
9. PROVIDE NYLON WASHER / GROMMETS AT DOOR HANDLES TO PREVENT METAL ON METAL CONTACT.
10. BOTH FRONT AND REAR EXTERIOR DOOR HARDWARE MUST ACCEPT THE BEST MASTER KEYING AND CORING
SYSTEM IN USE AT THE PROPERTY, AND BE KEYED IN ACCORDANCE WITH THE LANDLORD REQUIREMENTS.
EXISTING BACK DOOR CURRENTLY COMPLY WITH THIS REQUIREMENT. TENANT CONTRACTOR TO
COORDINATE WITH THE LANDLORD TO ENSURE RELOCATED ENTRY DOOR TO COMPLY WITH THIS
REQUIREMENT. TENANT CONTRACTOR TO VERIFY ANY FINAL KEYING CHANGES WITH LANDLORD AS
REQUIRED.
DOOR STYLE (FRAME & ELEVATIONS)
GENERAL DOOR NOTES
a. DOOR HARDWARE SHALL HAVE LEVER-OPERATED OR PUSH TYPE MECHANISMS
b. DOORS IN EXITS SHALL NOT BE SUBJECT TO THE USE OF A KEY FOR OPERATION FROM THE INSIDE OF THE BUILDING
c. ALL GLASS IN DOORS SHALL BE TEMPERED ( T )
d. TRIM THE BOTTOM OF DOORS TO CLEAR THE TOP OF ALL FINISHED FLOORS, AS APPLICABLE BY 1/4" MAXIMUM,
UNLESS OTHERWISE NOTED. VERIFY SLAB CONDITIONS, TRIM EACH DOOR TO FIT CONDITIONS. WHERE RADICAL
VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE
THESE UNDERCUT CONDITIONS.
HARDWARE REQUIREMENTS
6 DOOR JAMB DETAIL
A-5
SCALE: 1-1/2" = 1'-0"
7 DOOR HEAD DETAIL
A-5
SCALE: 1-1/2" = 1'-0"
4 MOP SINK DETAIL
A-5
SCALE: 1-1/2" = 1'-0"
5 DOOR THRESHOLD DETAIL
A-5
SCALE: 1-1/2" = 1'-0"
2'-47
8"
NOTE:
G.C. TO VERIFY & COORDINATE ALL COUNTER
CUT-OUTS WITH EQUIPMENT VENDOR PRIOR TO
FABRICATION & INSTALLATION
PROVIDE BRACKET SUPPORT SIM. TO DETAIL 2/A5.0 IN
THE EVENT THERE IS NO MILLWORK/WIRE SHELVE
BELOW COUNTER.
(G.C. TO VERIFY FUNCTION OF EXISTING
HARDWARE. IF REPLCEMENT IS NEEDED PROVIDE
TO MATCH EXISTING PER HARDWARE
REQUIREMENTS)
6'-27
8"
21'-73
4"
A5.0
2
2'-10 114'-6"
1
4'-9 4"
1
3'-0 4"
1
4"
7
1
8"
A5.0
3
12'-21
2"
2'-6"
R3"
TYP.
HW-1 (STOREFRONT HARDWARE)
· HINGES PER STOREFRONT MANUFACTURER
· (1) ADA COMPLIANT ALUMINUM THRESHOLD (1/2" MAX HEIGHT)
· (1) PUSH PLATE & BAR
· (1) PULL HANDLE
· (1) CLOSER W/ STOP ARM
· (1) COMMERCIAL GRADE DEADLOCK W/ THUMBTURN
· WEATHERSTRIPPING
SADDLE/THRESHOLD TYPES
S-1 ALUM. SADDLE COMPLYING TO THE
ACCESSIBILITY CODE
1/2
MAX.
1 03/10/2021 CLIENT REVIEW COMMENT
03/18/2021
1 1
1
2
2 03/18/2021 LANDLORD REVIEW COMMENT
VERIFY 4'-0" MAX
SUPPORT SPACING OF
COUNTER TOP WITH
MANUFACTURER AN
PROVIDE SUPPORT
BRACKETS AS
REQUIRED
COUNTERTOP BY G.C.
APPROVED BY OWNER
REFER TO FINISH SCHEDULE
1X4 WOOD BLOCKING
AS REQUIRED
2'-11
1
2"
CUSTOMER
SIDE
2'-10"
1
1
2"
REFER TO
FINISH
SCHEDULE
3'-0"
BASE SEE FINISH PLAN
1 5/8"X3-5/8" X
20 GA. @ 16"
O.C.
CLARK DIETRICH
PW24
PONY WALL STUD
AND BASE PLATE
OR EQUAL
FLOOR FINISH SEE
FINISH PLAN
1X4 WOOD BLOCKING
AS REQUIRED
1
1
2"
2'-10"
2'-6"
2'-11
1
2"
COUNTERTOP BY G.C.
APPROVED BY OWNER
REFER TO SCHEDULE
1"
1
1
2"
4"
2'-5"
3"
1X4 WOOD
BLOCKING
ANCHORED
TO EACH
STUD.
ANCHOR
CABINET
TO
BLOCKING
@ 12" O.C.
MOP SINK, SEE
PLUMBING PLANS
FRP TO COVER ALL
SURFACES @ MOP
SINK, OVER 5/8" M.R.
GWB, TYPICAL
WALL MOUNTED
MOP RACK
WALL MOUNTED
ECOLAB CLEANSING
PRODUCTS
WALL/SPLASH
MOUNT FAUCET,
SEE PLUMBING
PLANS
EQ.
5'-0"
MOP BASINS TO BE
INSTALLED PER MANUF'S
SPECIFICATIONS
EXISTING
STRUCTURE
℄
ANCHOR TRACK TO
(E) SLAB W/ HILTI
.145 SHOT PINS (OR
EQ) @ 16" O.C.
EQ.
3/4" TREATED PLYWOOD
DECK OVER 6" 16 GA.
UN-PUNCHED METAL
STUD JOISTS AT 16" O.C.
LAP JOIST INTO SIDE OF
STUD. ATTACH WITH (4)
#10 TEK SCREWS EACH
STUD
2'-0"
2"
2"
2"
2"
2"
2"
2"
2"
A B
FRAME INSTALL PER
MANUFACTURER
2"
2"
8'-0"± (MATCH EXISTING) 2" 2'-8"±
3'-0"
11'-0"±
2"
3'-4"±
NEW STOREFRONT TO
MATCH EXISTING
C
METAL FRAME, FIELD
PAINTED
ELIASON
2"
4
7
8"
2"
4
7
8"
2"
4
7
8"
2"
4
7
8"
2"
4
7
8"
GWB ON W/ 2X6 BOX
HEADER
DOOR AS SCHEDULED
NO RABBET @ DBL
OR SINGLE ACTING
DOOR
2"
4
7
8"
(2) FULL HEIGHT JAMB
STUDS
2"
4
7
8"
2"
4
7
8"
2"
4
7
8"
2"
4
7
8"
5/8" FINISHED GWB ON
2X4 STUDS
PROVIDE (3) JAMB
ANCHORS PER JAMB
DOOR AS SCHEDULED
NO RABBET @ DBL OR
SINLE ACTING DOOR
1"
DOOR AS SCHEDULED
UNDERCUT DOOR - 1"
TYP.
FLOOR FINISH: SEE
FINISH SCHEDULE
05/04/21