HomeMy WebLinkAboutD1.0 Demolition Plan14'-8" CONC DECK
B B B
14'-8" CONC DECK
CONC BEAM: 10'-8"
14'-8" CONC DECK
DUCTWORK: 10'-4" (9'-6" LOW PT)
CONC BEAM: 12'-2"
CONC BEAM: 12'-2"
CONC BEAM: 12'-2"
CONC BEAM: 12'-2"
CONC BEAM: 11'-0"
SPRINKLER MAIN
THRU BLG @ 9'-9"
(LOWEST EQUIP)
SOFFIT: 10'-1"
CONC BEAM: 11'-0"
SOFFIT: 10'-10"
8'-0"
3'-0" 1'-8" 3'-0" 1'-8" 3'-0"
2'-4" 5'-4" 2'-8" 3'-10"
B.WOODS
C.L. HELT PROJECT #
Sheet Description : Project :
Drawn By :
Checked By :
Revisions :
Seal
Date :
Sheet No.
CARMEL, IN 46032
21003
RITA'S
INTERIOR UPFIT
110 W MAIN STREET SUITE 127
6405 WILKINSON BLVD
SUITE 100
BELMONT, NC 28012
Ph. 704-342-1686
Fx. 704-343-0054
INFO@CLHELT.COM
D.MYERS
02/09/2021
02/15/2021
DEMOLITION PLAN
D1.0
1 DEMOLITON PLAN
D1.0
SCALE: 1/4" = 1'-0"
DEMO PLAN LEGEND
EXISTING DOOR, & GLASS TO BE
REMOVED.
EXISTING ELECTRICAL PANELS TO
REMAIN SEE ELECTRICAL
DEMO RCP LEGEND
WALL TYPE LEGEND
EXISTING WALL / PARTITION TO REMAIN
EXISTING STOREFRONT / GLASS, N.I.C.
EXISTING LIGHT
FIXTURES,SPEAKERS, SECURITY
CAMERAS TO BE REMOVED, SEE
ELECTRICAL
EXISTING MECHANICAL TO BE
REMAIN OR REMOVED - SEE
MECHANICAL
EXISTING EXIT/EMERGENCY SIGN
TO BE REMOVED
DEMOLITION NOTE
1. GYP. BD TO REMAIN ALONG PERIMETER WALL (OF AREA OF WORK). REPAIR /
REPLACE / REFINISH AS REQUIRED.
2. COORDINATE WITH ALL TRADES FOR TERMINATION AND RECONNECTION OF
MECHANICAL, ELECTRICAL, PLUMBING. ALL PENETRATIONS THROUGH
FLOORS, CEILINGS AND DEMISING WALLS SHALL PER IN COMPLIANCE WITH
CODE SECTION 711.
3. CONTRACTOR TO PROTECT AREAS TO REMAIN FROM DAMAGE, INCLUDING,
BUT NOT LIMITED TO FLOORING, GYPSUM BOARD CEILING, LIGHT FIXTURES,
HVAC, PLUMBING FIXTURES, ETC.
4. CONTRACTOR TO COORDINATE WITH LANDLORD FOR SITE ACCESS,
PARKING, HOURS OF OPERATION, ETC.
5. G.C. TO COORDINATE UNDER FLOOR UTILITY LOCATIONS WITH THE
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS
6. REMOVE ELECTRICAL RECEPTACLES OR RELOCATED SEE ELECTRICAL
DRAWINGS.
7. G.C. TO REMOVE THE EXISTING LIGHT FIXTURES SEE ELECTRICAL
DRAWINGS.
8. REMOVE EXISTING STOREFRONT SYSTEM AND STOREFRONT DOOR AS
INDICATED SEE DEMOLITION PLAN AND ELEVATION.
9. G.C. TO REMOVE EXISTING WATER HEATER AND MOP SINK
10. REFER TO ELECTRICAL, MECHANICAL AND PLUMBING FOR ADDITIONAL
INFORMATION.
11. G.C. TO PREP EXISTING FLOOR TO RECEIVE NEW FLOOR FINISH. SEE FINISH
PLAN AND SCHEDULE.
6, TYP.
FIRE ALARMS AND FIRE
SPRINKLER TO REMAIN
7, TYP.
8, TYP
9, TYP.
8, TYP
2 DEMOLITON ELEVATION
D1.0
SCALE: 1/4" = 1'-0"
05/04/21