HomeMy WebLinkAboutA110 - DOOR SCHEDULESDOOR HARDWARE
AFB AUTOMATIC FLUSH BOLT
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
CL CLOSER
DB DEADBOLT
DL DUMMY LEVER
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
H HOLD OPEN
KS KICK STOP
KF KEY FOB
KP KICK PLATE
KS KICK STOP
ML MAGNETIC LOCK
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
DOOR FRAME
1. CONTRACTOR TO VERIFY THAT NO HOLES/OPENINGS ARE IN
EXISTING DOOR DUE TO HARDWARE CHANGES. IF HOLES
ARE PRESENT THAT WILL NOT BE FILLED BY NEW HARDWARE,
CONTRACTORS TO CONTACT PARALLEL DESIGN GROUP TO
CONFIRM ON HOW TO MOVE FORWARD.
2. REUSE DOORS FROM DEMOLITION WHERE POSSIBLE.
PROVIDE NEW BUILDING STANDARD DOORS MATCHING
EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO
MATCH EXISTING. PRE-MACHINE NEW DOORS FOR
CYLINDRICAL LOCKSETS.
3. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE
POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING
STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON
NEW LOCK AND LATCHSETS.
4. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED.
REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE.
5. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT
WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN.
6. REFER TO TENANT AND LANDLORD FOR KEYING
REQUIREMENTS AND LOCKSETS.
7. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE
SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL
ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC
HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS
AND INSTALLATIONS MUST COMPLY WITH THE INDIANA
BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
8. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
9. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS
OTHERWISE NOTED.
10. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT
EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD
BLOCKING BEHIND WALL STOP.
11. PROVIDE COAT HOOK ON THE BACK OF ALL RESTROOM AND
OFFICE DOORS UNLESS NOTED OTHERWISE.
DOOR TYPES
FRAME TYPES
F2 F1
D1
SEE SCHEDULE 2"
2"
SEE SCHED.
2"
SEE SCHEDULE
SEE SCHED.
1/4" TEMPERED GLASS,
MATCH EXISTING
GLASS TEXTURE
2"
SEE SCHED.
2"
1' - 6"
2"
SEE SCHEDULE 2"
[PROJECT NUMBER]
[DATE]
[DRAWN BY]
[CHECKED BY]
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N
[ P ] [ W ]
Indianapolis, IN 46240
317.721.4399 ParallelDG.com
8940 River Crossing Blvd. Ste 150
2020.277
03.01.21
BW
KB
ADA RESTROOM
CARMEL, INDIANA 46032
11455 NORTH MERIDIAN STREET, SECOND FLOOR
A110
DOOR SCHEDULES
DOOR SCHEDULE
DOOR NUMBER ROOM
DOOR FRAME
COMMENTS
WIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE SET
200 CORRIDOR 3' - 6" x 7' - 0" x1 3/4" EXISTING EXISTING EXISTING F2 MATCH EXISTING MATCH EXISTING CL, CR, ES, SL HARDWARE TO MATCH EXISTING
201 RESTROOM 3' - 0" x 7' - 0" x1 3/4" D1 WOOD MATCH EXISTING F1 MATCH EXISTING MATCH EXISTING CH, KP, PL
REVISION SCHEDULE
MARK DATE DESCRIPTION
05/04/21