HomeMy WebLinkAboutA201 - REFLECTED CEILING PLANOS EX LEGEND INDICATES NIGHT LIGHT LOCATION EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH LIGHT SWITCH, 3-WAY OCCUPANCY SENSOR 3 O/C EL 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2' x 4' AT 8'-10" A.F.F. REPAIR ANY DAMAGED GRID AND PAINT GRID WHITE AS REQUIRED. 2. REUSE EXISTING CEILING TILE UNLESS OTHERWISE NOTED. REPLACE ALL DAMAGED OR DIRTY CEILING TILES WITH NEW TO MATCH EXISTING. PROVIDE LIKE TILES IN INDIVIDUAL ROOMS TO CREATE UNIFORM LOOK. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 7. CAN LIGHT FIXTURES TO BE ON SEPERATE SWITCH. 8. ALL DEVICES AND COVERS TO MATCH EXISTING. 9. IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL NOTES 2'x2', LED, BUILDING STANDARD NL CEILING TYPE CEILING HEIGHT ACT1 - 2' x 4' ACOUSTICAL CEILING TILE MFG: EXISTING TYPE: EXISTING EDGE TYPE: EXISTING GRID: 15/16" NRC RATING: 0.55 FIRE RATING: CLASS A EXISTING CEILING GRID, SUSPENDED, 2'x4' X X' - X" KEYNOTES RECESSED CAN, MATCH EXISTING C1 EXHAUST FAN 1 EX C1 2 2 3 AREA NOT IN CONTRACT AREA OF WORK [PROJECT NUMBER] [DATE] [DRAWN BY] [CHECKED BY] ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ] [ W ] Indianapolis, IN 46240 317.721.4399 ParallelDG.com 8940 River Crossing Blvd. Ste 150 2020.277 03.01.21 BW KB ADA RESTROOM CARMEL, INDIANA 46032 11455 NORTH MERIDIAN STREET, SECOND FLOOR A201 REFLECTED CEILING PLAN 1 RECIRCUIT EXISTING LIGHTING. TO BE CONTROLLED WITH NEW SWITCH AT THIS LOCATION. 2 TIE LIGHTS INTO EXISTING COMMON AREA SWITCH. 3 EXHAUST FAN (BY OTHERS) TO BE TIED INTO OCCUPANCY SENSOR SWITCH. 3/16" = 1'-0" REFLECTED CEILING PLAN 1 REVISION SCHEDULE MARK DATE DESCRIPTION 05/04/21