HomeMy WebLinkAboutA001 - LIFE SAFETY PLANAPPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2012 INDIANA BUILDING (2012 IBC, ASCE-7-2010)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES -
2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.
APPLICABLE BUILDING CODES
OCCUPANCY LOADS
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT - BUILDING EXIT LOCATION
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING,
REFERENCE A200 FOR LOCATION.
LEGEND
EX
EL
NL
EP
ASSEMBLY OCCUPANCY REGION(S)
STORAGE AREA REGION(S)
FE
EXIT DOOR
RECESSED FIRE EXTINGUISHER OR
SURFACE OR RECESSED FIRE EXTINGUISHER
AREA NOT IN CONTRACT
AREA OF WORK
EXIT ACCESS TRAVEL DISTANCE
EXIT ACCESS TRAVEL
DISTANCE: 30'
EX
EL
EX
EP
[PROJECT NUMBER]
[DATE]
[DRAWN BY]
[CHECKED BY]
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N
[ P ] [ W ]
Indianapolis, IN 46240
317.721.4399 ParallelDG.com
8940 River Crossing Blvd. Ste 150
2020.277
03.01.21
BW
KB
ADA RESTROOM
CARMEL, INDIANA 46032
11455 NORTH MERIDIAN STREET, SECOND FLOOR
A001
LIFE SAFETY PLAN
CHANGE OF OCCUPANCY CLASS:
No
SPRINKLER SYSTEM (YES/NO):
Yes
TOTAL BUILDING SQ FT:
32,804 SF
SCOPE OF WORK:
ADDITION OF COMMON SPACE ADA RESTROOM.
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS:
No
3/32" = 1'-0"
LIFE SAFETY PLAN
1
OCCUPANCY:
(B)USINESS
EXIT TRAVEL DISTANCE (FEET):
300
NUMBER OF REQUIRED EXITS:
1
COMMON TRAVEL PATH OF EGRESS (FEET):
100
USABLE AREA:
91 SF
TOTAL AREA ON FLOOR:
16,402 SF
OCC KEY SPACE TYPE OCC CLASSIFICATION AREA
SF PER
OCCUPANT
OCCUPANT
LOAD
(B)USINESS IBC Business areas 91 SF 100 0.9
Total Project Area / Total Project Occupant Load 91 SF 0.9
REVISION SCHEDULE
MARK DATE DESCRIPTION
05/04/21