Loading...
HomeMy WebLinkAboutGN010.1 Engr stamp16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). April 14,2021 Liu, Xuegang Pages or sheets covered by this seal: I45650371 thru I45650391 My license renewal date for the state of Indiana is July 31, 2022. j21102257 122 Sunrise IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE01 Truss Type COMMON SUPPORTED GAB Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650371 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-M?ahT_jfvzpBpp4fmE2r9XS_1z8g24cj9SZ7BlzQr1? Scale = 1:54.6 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 2x4 2x4 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-7-0 22-7-0 -0-10-8 0-10-8 11-3-8 11-3-8 22-7-0 11-3-8 23-5-8 0-10-8 0-10-108-4-150-10-108.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.07 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 12 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 306 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-7-0. (lb) - Max Horz 25=-102(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 22, 24, 17, 15 Max Grav All reactions 250 lb or less at joint(s) 25, 14, 19, 21, 22, 23, 24, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 24, 17, 15. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE02 Truss Type GABLE Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650372 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:32 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-IOiSuglvRa4v27E2uf5JEyYALmdHWx_0dm2EEezQr0z Scale = 1:75.4 Sheet Front Right Option 7-0-0 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 39 40 3x6 4x8 3x6 3x8 3x6 3x6 3x4 3x4 3x4 10x10 10x10 2x4 3x6 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5-0-17-0-0 9-9-6 9-9-6 19-4-4 9-6-14 21-10-12 2-6-8 22-4-0 0-5-4 29-4-0 7-0-0 -0-10-8 0-10-8 7-5-4 7-5-4 10-6-1 3-0-13 14-8-0 4-1-15 21-10-12 7-2-12 29-4-0 7-5-4 30-2-8 0-10-8 0-10-1010-7-150-10-108.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-0], [2:0-1-12,0-1-3], [5:0-1-9,0-1-8], [8:0-1-12,0-1-3], [10:Edge,0-2-14], [10:0-1-12,0-0-0], [15:0-0-0,0-1-8], [17:0-2-14,0-0-5], [20:0-1-11,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.74 0.89 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.50 0.02 (loc) 13-14 13-14 10 l/defl >787 >465 n/a L/d 240 180 n/a PLATES MT20 Weight: 316 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-13,5-11: 2x4 SPF No.2, 2-14,8-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-11, 3-14 REACTIONS. (size)11=0-3-8, 10=0-3-8, 14=0-3-8 Max Horz 14=-127(LC 8) Max Grav 11=1196(LC 17), 10=545(LC 18), 14=937(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-707/48, 3-5=-887/40, 5-7=-252/105, 7-8=-626/64, 2-14=-580/32, 10-15=-410/29, 8-15=-528/42 BOT CHORD 13-14=0/841, 11-13=0/361, 10-11=0/251 WEBS 3-13=-386/100, 5-13=0/786, 5-11=-616/0, 7-11=-418/93, 3-14=-393/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE03 Truss Type GABLE Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650373 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:33 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-maFq60mYCuClgHoERMcYn94UuAAWFRT9rQoon4zQr0y Scale = 1:60.6 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 28 27 26 25 24 23 22 21 20 19 18 17 16 15 29 2x4 2x4 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-6-0 24-6-0 -0-10-8 0-10-8 12-3-0 12-3-0 24-6-0 12-3-0 0-11-49-1-40-11-48.00 12 Plate Offsets (X,Y)-- [21:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.06 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 1 1 15 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 354 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-22 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 28=176(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 28, 15, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 28, 15, 22, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 2-3-0, Exterior(2N) 2-3-0 to 9-3-0, Corner(3R) 9-3-0 to 15-3-0, Exterior(2N) 15-3-0 to 21-4-4, Corner(3E) 21-4-4 to 24-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 15, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE04 Truss Type GABLE Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650374 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-EmpCJMmAzCKcIRNQ?47nJNdfjaWm_ujJ44XLJXzQr0x Scale = 1:60.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 2x4 2x4 4x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-6-0 24-6-0 -0-10-8 0-10-8 12-3-0 12-3-0 24-6-0 12-3-0 25-4-8 0-10-8 0-11-49-1-40-11-48.00 12 Plate Offsets (X,Y)-- [22:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.06 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 355 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-23 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 29=-180(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 29, 16, 24, 25, 26, 27, 28, 21, 20, 19, 18, 17 Max Grav All reactions 250 lb or less at joint(s) 29, 16, 23, 24, 25, 26, 27, 28, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 2-3-0, Exterior(2N) 2-3-0 to 9-3-0, Corner(3R) 9-3-0 to 15-3-0, Exterior(2N) 15-3-0 to 22-3-0, Corner(3E) 22-3-0 to 25-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 16, 24, 25, 26, 27, 28, 21, 20, 19, 18, 17. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650375 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-B9xzk2oQVpaKXkXp7V9FOoi?oNCZSnjcYO0SNPzQr0v Scale = 1:45.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-7-0 14-7-0 -0-10-8 0-10-8 7-3-8 7-3-8 14-7-0 7-3-8 15-5-8 0-10-8 1-1-07-1-151-1-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.07 0.03 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 184 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-7-0. (lb) - Max Horz 20=-91(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE06 Truss Type GABLE Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650376 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-B9xzk2oQVpaKXkXp7V9FOoiqMN5ESpxcYO0SNPzQr0v Scale = 1:21.0 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 2x4 3x4 3x4 2x4 2x4 2x4 2x4 6-7-8 6-7-8 -0-10-8 0-10-8 6-7-8 6-7-8 0-8-03-5-23-1-100-3-83-5-25.00 12 Plate Offsets (X,Y)-- [2:0-1-8,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.80 0.50 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.21 0.00 (loc) 2-5 2-5 5 l/defl >736 >368 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 3-5-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-1-8 Max Horz 2=58(LC 9) Max Grav 2=315(LC 1), 5=256(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss GE07 Truss Type Roof Special Structural Gable Qty 2 Ply 1 122 Sunrise Job Reference (optional) I45650377 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-fLVLxOp2G7iB9u6?gCgUx?F4znQuB20lm2m?wrzQr0u Scale = 1:55.1 Sheet Front Right Option 10-0-0 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 15 14 13 12 11 22 23 24 10 4x6 4x8 10x10 3x6 3x6 3x6 3x8 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4x6 3x6 10-0-0 5-9-0 5-9-0 11-3-8 5-6-8 16-7-0 5-3-8 16-9-8 0-2-8 22-7-0 5-9-8 26-7-0 4-0-0 -0-10-8 0-10-8 5-9-0 5-9-0 11-3-8 5-6-8 16-7-0 5-3-8 16-9-8 0-2-8 21-7-0 4-9-8 26-7-0 5-0-0 27-5-8 0-10-8 0-10-104-8-158-4-150-8-08.00 12 5.00 12 Plate Offsets (X,Y)-- [8:0-3-3,0-2-7], [14:0-2-8,0-1-8], [15:0-1-12,0-0-0], [15:Edge,0-8-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.49 0.54 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.17 0.05 (loc) 11-13 11-13 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 165 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-15: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 SLIDER Right 2x4 SPF-S Stud 2-7-15 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)15=0-3-8, 8=4-3-8, 10=0-3-8 Max Horz 15=-171(LC 8) Max Uplift 15=-15(LC 10), 8=-75(LC 11) Max Grav 15=1096(LC 1), 8=986(LC 1), 10=231(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1379/90, 3-4=-1093/143, 4-5=-1085/140, 5-6=-1559/122, 6-8=-1824/156, 2-15=-1038/105 BOT CHORD 14-15=-128/363, 13-14=-34/1071, 11-13=-18/1398, 10-11=-94/1574, 8-10=-94/1574 WEBS 3-13=-345/108, 4-13=-38/781, 5-13=-733/124, 2-14=0/820 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 8-3-8, Exterior(2R) 8-3-8 to 14-3-8, Interior(1) 14-3-8 to 24-5-8, Exterior(2E) 24-5-8 to 27-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 8. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss M01 Truss Type MONO TRUSS Qty 7 Ply 1 122 Sunrise Job Reference (optional) I45650378 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:38 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-7Y3j9kqg1Qq2m2hCEwBjUDnAsBmhwjQu?iVZSIzQr0t Scale = 1:21.0 1 2 3 4 5 2x4 3x4 3x4 2x4 2x4 6-7-8 6-7-8 -0-10-8 0-10-8 6-7-8 6-7-8 0-8-03-5-23-1-100-3-83-5-25.00 12 Plate Offsets (X,Y)-- [2:0-1-8,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.80 0.50 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.21 0.00 (loc) 2-5 2-5 5 l/defl >736 >368 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 3-5-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-1-8 Max Horz 2=58(LC 9) Max Grav 2=315(LC 1), 5=256(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T01 Truss Type Common Qty 3 Ply 1 122 Sunrise Job Reference (optional) I45650379 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:39 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-bkd5M3qIokyvOCGOodjy0QKNNb0df_v2EMF6_kzQr0s Scale = 1:53.2 1 2 3 4 5 6 7 11 10 9 8 4x6 5x12 WB 3x8 3x6 3x6 10x10 10x10 11-3-8 11-3-8 22-7-0 11-3-8 -0-10-8 0-10-8 5-9-0 5-9-0 11-3-8 5-6-8 16-10-0 5-6-8 22-7-0 5-9-0 23-5-8 0-10-8 0-10-108-4-150-10-108.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-3], [2:Edge,0-3-8], [6:0-1-12,0-1-3], [8:Edge,0-3-8], [10:0-4-8,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.69 0.84 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.59 0.03 (loc) 9-11 9-11 8 l/defl >910 >450 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 8-10: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=-102(LC 8) Max Grav 11=953(LC 1), 8=953(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-485/0, 3-4=-887/0, 4-5=-887/0, 5-6=-484/0, 2-11=-442/0, 6-8=-441/0 BOT CHORD 9-11=0/854, 8-9=0/855 WEBS 4-9=0/599, 5-9=-275/81, 3-9=-275/81, 3-11=-668/0, 5-8=-669/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T02 Truss Type Common Qty 5 Ply 1 122 Sunrise Job Reference (optional) I45650380 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:40 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-3wATaPrxZ24m0MraMKEBZdtXP?K_OXDBS0_fWAzQr0r Scale = 1:62.2 1 2 3 4 5 6 7 8 9 14 13 12 11 10151617181920 3x6 4x8 3x6 3x6 3x6 3x4 3x4 3x4 10x10 10x10 9-9-6 9-9-6 19-4-4 9-6-14 29-4-0 9-11-12 -0-10-8 0-10-8 7-5-4 7-5-4 14-8-0 7-2-12 21-10-12 7-2-12 29-4-0 7-5-4 30-2-8 0-10-8 0-10-1010-7-150-10-108.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-3], [2:Edge,0-3-0], [8:0-1-12,0-1-3], [8:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.74 0.96 0.43 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.46 0.02 (loc) 10-11 10-11 10 l/defl >477 >256 n/a L/d 240 180 n/a PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-13,5-11: 2x4 SPF No.2, 2-14,8-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-11-2 oc bracing. WEBS 1 Row at midpt 5-11, 3-14 REACTIONS. (size)11=0-3-8, 14=0-3-8, 10=0-3-8 Max Horz 14=-127(LC 8) Max Grav 11=1389(LC 17), 14=926(LC 17), 10=485(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-687/48, 3-5=-877/42, 7-8=-592/56, 2-14=-568/32, 8-10=-510/38 BOT CHORD 13-14=0/832, 11-13=0/331 WEBS 3-13=-387/99, 5-13=0/836, 5-11=-728/0, 7-11=-421/93, 3-14=-397/0, 7-10=-16/305 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T03 Truss Type Common Qty 8 Ply 1 122 Sunrise Job Reference (optional) I45650381 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-X7ksnlsZKLCddWQmv2lQ5rPiUOmY7vKLhgkD3dzQr0q Scale = 1:62.2 1 2 3 4 5 6 7 8 9 14 13 12 11 10151617181920 3x6 4x8 3x6 3x6 3x6 3x6 3x6 3x6 3x8 3x12 3x8 3x12 9-10-3 9-10-3 19-5-13 9-7-11 29-4-0 9-10-3 -0-10-8 0-10-8 7-5-4 7-5-4 14-8-0 7-2-12 21-10-12 7-2-12 29-4-0 7-5-4 30-2-8 0-10-8 0-10-1010-7-150-10-108.00 12 Plate Offsets (X,Y)-- [2:0-1-0,0-1-8], [8:0-1-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.72 0.62 0.76 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.34 0.04 (loc) 11-13 13-14 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-11,5-13: 2x4 SPF No.2, 2-14,8-10: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 7-10 REACTIONS. (size)14=0-3-8, 10=0-3-8 Max Horz 14=-128(LC 8) Max Grav 14=1395(LC 17), 10=1395(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-777/43, 3-5=-1618/0, 5-7=-1618/0, 7-8=-777/43, 2-14=-629/28, 8-10=-629/28 BOT CHORD 13-14=0/1429, 11-13=0/981, 10-11=0/1353 WEBS 5-11=0/773, 7-11=-346/104, 5-13=0/773, 3-13=-346/104, 3-14=-1055/0, 7-10=-1055/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T04 Truss Type Common Qty 5 Ply 1 122 Sunrise Job Reference (optional) I45650382 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-?JIE_5tB5fKUFf?zTlGfe2yxJo5MsUIUwKTmb3zQr0p Scale = 1:53.2 12 3 4 5 6 7 8 11 10 9 12 13 14 15 4x6 4x10 4x6 4x6 4x10 4x6 4x6 3x6 3x4 2x4 3x4 2x4 8-2-13 8-2-13 16-3-3 8-0-5 24-6-0 8-2-13 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 0-11-49-1-40-11-48.00 12 Plate Offsets (X,Y)-- [2:0-7-1,Edge], [8:0-7-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.65 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.26 0.04 (loc) 9-11 9-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 100 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-10-4, Right 2x6 SPF No.2 3-10-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=Mechanical, 2=0-3-8 Max Horz 2=-162(LC 6) Max Uplift 2=-11(LC 10) Max Grav 8=1105(LC 18), 2=1155(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1434/47, 4-5=-1314/108, 5-6=-1317/109, 6-8=-1438/48 BOT CHORD 2-11=-47/1198, 9-11=0/826, 8-9=0/1097 WEBS 5-9=-68/636, 6-9=-291/171, 5-11=-67/632, 4-11=-288/171 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 9-3-0, Exterior(2R) 9-3-0 to 15-3-0, Interior(1) 15-3-0 to 21-6-0, Exterior(2E) 21-6-0 to 24-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T05 Truss Type Roof Special Qty 2 Ply 1 122 Sunrise Job Reference (optional) I45650383 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:43 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-TVscCRtpszSLtpZ91TnuBGV5lCSRbnTe9_DJ7VzQr0o Scale = 1:53.8 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 4x6 3x8 10x10 2x4 8x10 4x6 2x4 2x4 3x8 3x4 5x6 4x8 4x10 3x6 6-2-12 6-2-12 14-1-0 7-10-4 19-1-0 5-0-0 21-8-4 2-7-4 24-6-0 2-9-12 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 14-1-0 1-10-0 19-1-0 5-0-0 21-8-4 2-7-4 24-6-0 2-9-12 0-11-49-1-40-11-42-0-08.00 12 Plate Offsets (X,Y)-- [16:0-1-12,0-0-0], [16:Edge,0-8-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.54 0.59 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.31 0.17 (loc) 14-15 14-15 9 l/defl >999 >939 n/a L/d 240 180 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-14,6-11: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-16,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14 REACTIONS. (size)16=0-3-8, 9=Mechanical Max Horz 16=176(LC 7) Max Uplift 16=-13(LC 10) Max Grav 16=1031(LC 1), 9=967(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1276/30, 3-4=-1041/72, 4-5=-1255/109, 5-6=-1330/50, 6-7=-2375/0, 7-8=-1154/14, 2-16=-978/49, 8-9=-926/14 BOT CHORD 15-16=-160/360, 14-15=-31/980, 13-14=0/649, 12-13=0/1993, 6-12=0/754 WEBS 3-14=-1100/44, 3-13=0/777, 4-13=-59/1010, 6-13=-1036/75, 10-12=0/1178, 7-12=0/1057, 7-10=-956/10, 2-15=0/738, 8-10=0/849 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 9-3-0, Exterior(2R) 9-3-0 to 15-3-0, Interior(1) 15-3-0 to 21-4-4, Exterior(2E) 21-4-4 to 24-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T06 Truss Type Common Qty 7 Ply 1 122 Sunrise Job Reference (optional) I45650384 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-yhQ_PnuRcGaCUz8LbAI7jT1HqcnsKOonNeytfxzQr0n Scale = 1:53.6 12 3 4 5 6 7 8 9 12 11 10 13 14 15 16 4x6 4x10 4x6 4x6 3x6 3x4 2x4 3x4 2x4 4x10 4x6 4x6 8-2-13 8-2-13 16-3-3 8-0-5 24-6-0 8-2-13 -0-10-8 0-10-8 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 25-4-8 0-10-8 0-11-49-1-40-11-48.00 12 Plate Offsets (X,Y)-- [2:0-7-1,Edge], [8:0-7-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.45 0.65 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.26 0.04 (loc) 10-12 10-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 101 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-10-4, Right 2x6 SPF No.2 3-10-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-161(LC 6) Max Uplift 2=-11(LC 10), 8=-11(LC 11) Max Grav 2=1154(LC 17), 8=1154(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1433/47, 4-5=-1313/108, 5-6=-1313/108, 6-8=-1433/47 BOT CHORD 2-12=-47/1197, 10-12=0/825, 8-10=0/1094 WEBS 5-10=-68/632, 6-10=-288/171, 5-12=-67/632, 4-12=-288/171 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 9-3-0, Exterior(2R) 9-3-0 to 15-3-0, Interior(1) 15-3-0 to 22-4-8, Exterior(2E) 22-4-8 to 25-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T07 Truss Type Common Qty 2 Ply 1 122 Sunrise Job Reference (optional) I45650385 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-Qu_Md7v3Nai267jY8upMGhaPT0Af3tIwcIiQCOzQr0m Scale = 1:42.7 1 2 3 4 5 8 7 6 4x6 3x4 3x4 3x8 4x8 4x8 7-3-8 7-3-8 14-7-0 7-3-8 -0-10-8 0-10-8 7-3-8 7-3-8 14-7-0 7-3-8 15-5-8 0-10-8 1-1-07-1-151-1-010.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-12], [4:0-2-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.65 0.42 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.10 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-92(LC 8) Max Grav 8=631(LC 1), 6=631(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-568/0, 3-4=-568/0, 2-8=-569/0, 4-6=-569/0 BOT CHORD 7-8=-96/374, 6-7=-60/331 WEBS 3-7=0/297 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss T08 Truss Type Roof Special Qty 6 Ply 1 122 Sunrise Job Reference (optional) I45650386 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-u4YlqTwh8uqvkHIkibLbou7eFPNxoFJ4ryR_kqzQr0l Scale = 1:55.1 1 2 3 4 5 6 7 8 9 10 13 12 11 14 15 16 4x6 4x8 6x10 4x6 4x6 3x6 4x8 2x4 3x4 2x4 4x10 3x8 11-3-8 11-3-8 16-9-8 5-6-0 26-7-0 9-9-8 -0-10-8 0-10-8 5-9-0 5-9-0 11-3-8 5-6-8 16-9-8 5-6-0 21-7-0 4-9-8 26-7-0 5-0-0 27-5-8 0-10-8 0-10-104-8-158-4-150-8-08.00 12 5.00 12 Plate Offsets (X,Y)-- [9:0-0-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.39 0.99 0.39 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.30 -0.62 0.06 (loc) 2-13 2-13 9 l/defl >999 >513 n/a L/d 240 180 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 3-6-7, Right 2x4 SPF-S Stud 2-7-15 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 6-13 REACTIONS. (size)2=0-3-8, 9=0-3-8 Max Horz 2=-161(LC 8) Max Uplift 2=-4(LC 10), 9=-29(LC 11) Max Grav 2=1116(LC 1), 9=1116(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1438/114, 4-5=-1155/118, 5-6=-1148/117, 6-7=-1700/80, 7-9=-1982/100 BOT CHORD 2-13=-47/1086, 11-13=0/1514, 9-11=-38/1737 WEBS 4-13=-292/146, 5-13=-7/839, 6-13=-813/100, 6-11=0/310, 7-11=-263/105 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 8-3-8, Exterior(2R) 8-3-8 to 14-3-8, Interior(1) 14-3-8 to 24-5-8, Exterior(2E) 24-5-8 to 27-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 122 Sunrise Job Reference (optional) I45650387 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-MG672oxKvBzmLRtwGJsqL6fr4ptfXilD3cBXGGzQr0k Scale = 1:42.0 1 2 3 4 5 6 7 9 810111213 14 15 16 6x10 4x6 4x8 6x10 4x6 10x10 2x4 10x10 2x4 4-11-8 4-11-8 9-7-8 4-8-0 14-7-0 4-11-8 3-9-8 3-9-8 7-3-8 3-6-0 10-9-8 3-6-0 14-7-0 3-9-8 1-1-07-1-151-1-010.00 12 Plate Offsets (X,Y)-- [1:0-4-12,0-0-4], [7:0-7-11,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.26 0.32 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.08 0.01 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 165 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 2-6-13, Right 2x6 SPF No.2 2-6-13 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 7=0-3-8 Max Horz 1=76(LC 26) Max Grav 1=3762(LC 2), 7=4278(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-4138/0, 3-4=-3969/41, 4-5=-3910/41, 5-7=-4079/0 BOT CHORD 1-9=0/3003, 8-9=0/2210, 7-8=0/2958 WEBS 4-8=-39/2440, 4-9=-39/2579 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1054 lb down and 20 lb up at 2-0-12, 1054 lb down and 20 lb up at 4-0-12, 1054 lb down and 20 lb up at 6-0-12, 1054 lb down and 20 lb up at 8-0-12, 1054 lb down and 20 lb up at 10-0-12, and 947 lb down and 20 lb up at 12-0-12, and 952 lb down and 15 lb up at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Continued on page 2 April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 122 Sunrise Job Reference (optional) I45650387 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:47 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-MG672oxKvBzmLRtwGJsqL6fr4ptfXilD3cBXGGzQr0k LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 10=-959(F) 11=-959(F) 12=-959(F) 13=-959(F) 14=-959(F) 15=-947(F) 16=-952(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss V01 Truss Type GABLE Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650388 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:48 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-qTfVF8xygV5dzaS7q0N3uJC1qDIyGFwNIGw4ojzQr0j Scale = 1:30.1 1 2 3 4 5 8 7 63x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 11-9-15 11-9-15 5-11-0 5-11-0 11-9-15 5-11-0 0-0-44-11-20-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.20 0.06 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-9-15. (lb) - Max Horz 1=52(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=262(LC 23), 6=262(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss V02 Truss Type Valley Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650389 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-IfDtSUyaRpDUbk1JNjuIQXl5hdaV?iHWXwgeL9zQr0i Scale = 1:24.6 1 2 3 43x6 3x6 3x6 2x4 0-0-5 0-0-5 8-7-9 8-7-4 4-3-12 4-3-12 8-7-9 4-3-12 0-0-43-7-20-0-410.00 12 Plate Offsets (X,Y)-- [1:0-5-6,Edge], [2:0-3-12,0-1-8], [3:0-2-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.64 0.30 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-6-15, 3=8-6-15, 4=8-6-15 Max Horz 1=38(LC 7) Max Grav 1=183(LC 1), 3=183(LC 1), 4=278(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss V03 Truss Type Valley Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650390 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-mrnFgqzCC6LLCucVxRPXzkHM51zgk93gmaPBtbzQr0h Scale = 1:16.3 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 5-5-2 5-4-13 2-8-9 2-8-9 5-5-2 2-8-9 0-0-42-3-20-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.11 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-9, 3=5-4-9, 4=5-4-9 Max Horz 1=-23(LC 8) Max Grav 1=110(LC 1), 3=110(LC 1), 4=168(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21102257 Truss V04 Truss Type Valley Qty 1 Ply 1 122 Sunrise Job Reference (optional) I45650391 8.240 s Mar 9 2020 MiTek Industries, Inc. Wed Apr 14 09:48:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:DAggLdpU7x0EelaRy2YKeQzoaXA-mrnFgqzCC6LLCucVxRPXzkHP41_Tk9OgmaPBtbzQr0h Scale = 1:7.4 1 2 3 2x4 2x4 2x4 0-0-5 0-0-5 2-2-12 2-2-7 1-1-6 1-1-6 2-2-12 1-1-6 0-0-40-11-20-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-2-2, 3=2-2-2 Max Horz 1=-8(LC 6) Max Grav 1=66(LC 1), 3=66(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=90mph (3-second gust) Vasd=71mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 14,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths