HomeMy WebLinkAbout10_A103R21 22 23 25 26 29 34
A103R
FIRST FLOOR -
AREA 1 ENLARGED
REFERENCE PLAN
FIRST FLOOR - AREA 1 ENLARGED REFERENCE PLAN
SCALE: 3/16" = 1'-0"1N
PROJECT NUMBER: 2020-007
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:
These drawings are intended for construction.
12.23.2020DATE ISSUED:
REVISIONS ISSUED:
CONSTRUCTION ISSUE SET
CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING
COLLABORATIVE
SAM HURT, P.E.
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, IN. 46241
PH: 317.636.3941
E-MAIL: sam@tec-mep.com
PROJECT CONTACT:
MEP ENGINEER:
KEY PLANN
SCALE: 1/64" = 1'-0"
AREA 1
(A103)
AREA 2
(A104)
AREA 4
(A106)
AREA 3
(A105)
VESTIBULE A
101
PRODUCE
102
FLORAL
103
CHECK OUT
104LANE 1LANE 2LANE 3LANE 4MATCH LINEMATCH LINE MATCH LINEMATCH LINE
AREA 1 AREA 2
AREA 1
AREA 2
AREA 4 AREA 1 AREA NOT
IN SCOPE
GENERAL
SHELVING
114
BEER/
WINE
115
MEAT
117
MEAT
FREEZER
143
MEAT
COUNTER
142
MEAT
COOLER
144
MEAT
PREP
145
PRODUCE
DISPLAY
146
CHOP
SHOP
147CORR
148
PRODUCE
PREP
150
JANITOR
151
MGR/LOSS PREV.
OFFICE
152
BREAK
ROOM
153
PRODUCE
COOLER
154
CORR
155
COMPRESSOR
RACK B
156
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR EXTERIOR
CC6
CC1
CC3
CC2
CC4
CC5
101A
101B 101C143142145A
145B145C
148A148B 151152153 1561551
2
2
V1
V2
V3
J1
J3
J2
3
4 5
CC7
P1
9
P2
P2
P4
P4
P5
P5
P5
P6
P5
P5
9
9 9
CO1
CO1
CO3
W4W3W3W3W3W1 W5W5W6W7W7W24W19
W21
W22W22W22
W10 W10W10W26 W11W27W24 W29
W11 W11W33
W11 W11 W1W1
W11
W16
W24 W24W29
W
3
0 W16W16W16
W16
W18
W18
W18 W18P7
P8
P9
P10 P11
P12
BR1
P13
MO1
MO2
MO3
MO4
BW1
(8) TYP.
5
11
12
13
14
7/A601
8/A601M1
M2M2
M4
M4
M5
M7
M8
M9
M10
M10
M11
5
M12
M13
M14
M11
M15
M16
M13
M11
M13
M17
M18
M18
12
11
5
M9
M19
M20
M21
16
M23
M24
M24
18
18
GS1
(18) TYP.
GENERAL PLAN NOTES:
FLOOR PLAN NOTES: X
1. EXISTING EXTERIOR SLIDING ENTRANCE DOORS INSTALLED AS
PART OF SHELL PACKAGE. NO GC WORK REQUIRED.
B. CONTRACTOR SHALL PROVIDE PHYSICAL SAMPLES AND SHOP
DRAWINGS FOR ALL FINISH MATERIALS TO ARCHITECT FOR
REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND
INSTALLATION.
A. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL
DISCREPANCIES ON DRAWINGS RELATIVE TO CONDITIONS IN THE
FIELD. REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO
PROCEEDING WITH WORK IN THE AFFECTED AREA.
2. NEW INTERIOR AUTOMATIC SLIDING DOOR PACKAGE AND
SIDELITE WINDOWS. SEE DOOR/WINDOW SCHEDULE.
3. FLOOR MOUNTED MOP SINK - SEE PLUMBING DRAWINGS.
4. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - LH.
SEE PLUMBING DWGS.
5. WALL MOUNTED HAND WASHING SINK. SEE PLUMBING DWGS.
6. ELECTRICAL FLOOR BOX - SEE ELECTRICAL DRAWINGS.
7. COUNTER MOUNTED SINK. SEE PLUMBING DWGS.
8. CUSTOM BUILT IN MILLWORK.
9. CUT EXISTING CONCRETE SLAB IN THIS AREA TO FEED POWER/
DATA OR REFRIGERANT LINES UNDER SLAB. APPROXIMATE
LOCATION SHOWN. GC SEE AND COORDINATE WITH
ELECTRICAL, PLUMBING, AND REFRIGERATION DRAWINGS.
(REFRIGERATION DRAWINGS BY OTHERS). VERIFY LOCATIONS IN
THE FIELD AND PROVIDE A SLAB CUT PLAN/LAYOUT FOR REVIEW
ON SITE PRIOR TO COMMENCING WITH SLAB CUTTING.
11. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - RH.
SEE PLUMBING DWGS.
12. FLOOR MOUNTED 3 COMPARTMENT SINK WITH DRAINBOARDS
ON BOTH ENDS. SEE PLUMBING DWGS.
13. EXISTING ELECTRICAL PANELS. SEE ELEC. DWGS.
14. NEW PLASTIC LAMINATE WORK COUNTER. SEE INTERIOR
ELEVATIONS.
15. EXISTING COOLER. NEW OPENING IN COOLER WALL AND DOOR
RELOCATION/INSTALLATION WORK BY OTHERS. COORDINATE
WITH OWNER.
16. FIVE (5) WALL MOUNTED COAT HOOKS ON EXISTING COOLER
WALL. COORDINATE LOCATION WITH OWNER.
17. EXISTING CURB AND DRAIN WASHOUT AREA TO REMAIN.
PROVIDE NEW DRAIN COVER AND VERIFY EXISTING DRAIN
FUNCTIONS PROPERLY.
18. EXISTING STRUCTURAL COLUMN TO REMAIN. PAINT.
REFERENCE FINISH PLAN FOR PAINT COLORS. OWNER
GONDOLA SHELVING INSTALLER TO COORDINATE MODIFICATION
TO SHELVING UNITS FOR INSTALLATION OF SHELVING AT
EXISTING COLUMNS
19. HAND SINK. DROP-IN - 12" WITH SPLASH GUARD. SEE PLUMBING
DWGS.
20. UTILITY SINK. DROP IN - 18"D X 18"W. SEE PLUMBING DWGS.
21. DIPPERWELL FAUCET AND SINK ASSEMBLY (FISHER 3041).
SEE PLUMBING DWGS.
22. 7" HIGH SNEEZE GUARD. SEE INTERIOR ELEVATIONS.
23. CUSTOM MILLWORK SWINGING GATE. SEE INTERIOR
ELEVATIONS.
24. ADA COMPLIANT UNDERMOUNT BREAK ROOM SINK.
SEE PLUMBING DWGS.
25. SEE MEP DWGS. FOR EQUIPMENT IN THIS AREA.
26. WHITE MELAMINE STORAGE SHELVES (2) ON ADJUSTABLE
STANDARDS. SEE INTERIOR ELEVATIONS.
27. 3-5/8" STEEL STUD PARTIAL HEIGHT WALL - FINISHED HEIGHT TO
TOP OF WALL CAP TO BE 4'-0" A.F.F. EMBED 2X2 STEEL TUBES
INTO SLAB TO REINFORCE WALL. SEE FINISH PLAN FOR WALL
AND CAP FINISH.
28. EXISTING WALL MOUNTED SHIP LADDER TO REMAIN.
29. DASHED LINE INDICATES LINE OF SECOND FLOOR MECHANICAL
AREA ABOVE.
30. EXISTING COOLER/FREEZER TO REMAIN.
31. EXISTING EXHAUST HOOD. REPAIR, REPLACE, AND CLEAN
EXISTING HOOD AND COMPONENTS AS NEEDED TO FULL
OPERATING CONDITION.
32. ONE COMPARTMENT FOOD PREP SINK - 30". SEE PLUMBING DWGS
33. NEW SOLID SURFACE LAVATORY COUNTER WITH INTEGRAL SINKS.
PROVIDE IN-WALL MOUNTED COUNTER SUPPORT BRACKETS
(RAKKS OR APPROVED EQUAL)WITH BLOCKING IN EXISTING WALL
AS REQ'D. PROVIDE REQUIRED ADA PROTECTION FOR WASTE
AND SUPPLY LINES.
34. BASIN-MOUNTED SOAP DISPENSER. (GOJO 8520-01).
35. AUTOMATIC SEMI-RECESSED ROLL TOWEL DISPENSER/WASTE
RECEPTACLE COMBINATION (GAMCO TW-14RP).
36. INDIVIDUAL FRAMELESS MIRRORS TO BE CENTERED ABOVE
EACH LAVATORY. SEE INTERIOR ELEVATIONS.
37. WALL MOUNTED ADA COMPLIANT URINAL FIXTURE. SEE
PLUMBING DRAWINGS.
39. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET
TISSUE DISPENSER. (GEORGIA PACIFIC COMPACT 2 ROLL
UNIT #56782).
40. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
41. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
42. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA.
(GAMCO 150C SERIES)
38. WALL MOUNTED SEAT PROTECTOR DISPENSER.
(BOBRICK B-221 SS).
44. SURFACE MOUNTED ADA COMPLIANT SANITARY NAPKIN
DISPOSAL. (GAMCO ND-5).
45. 5'-0" ADA TURNING CIRCLE SHOWN FOR REFERENCE. THIS IS NOT
A FLOOR PATTERN.
46. AUTOMATIC FAUCET, SEE PLUMBING DRAWINGS.
47. FLOOR MOUNTED TOILET FIXTURE, SEE PLUMBING DRAWINGS.
43. FLOOR MOUNTED, OVERHEAD BRACED PHENOLIC TOILET
PARTITIONS. PROVIDE A COAT HOOK ON INSIDE OF EACH
PARTITION DOOR CONTRACTOR TO PROVIDE WALL BLOCKING AS
REQUIRED. COLOR TO BE SELECTED BY ARCHITECT.
48. DRINKING FOUNTAIN. SEE PLUMBING DRAWINGS FOR SPEC. AND
ADA / STANDARD MOUNTING HEIGHT.
49. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
50. SURFACE MOUNTED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
51. OWNER PROVIDED/OWNER INSTALLED TV MONITOR. GC TO
PROVIDE POWER AND DATA ONLY TO THIS LOCATION. GC
COORDINATE POWER/DATA LOCATIONS WITH OWNER'S ARTWORK
PROVIDER/INSTALLER.
52. GRAPHICS/ARTWORK DISPLAY WALL TO BE PROVIDED AND
INSTALLED BY ARTWORK PROVIDER/INSTALLER. GC COORDINATE
WITH OWNER.
53. NEW EXHAUST HOOD - DESIGN AND INSTALLATION BY OTHERS.
COORDINATE WITH MEP ENGINEER FOR MAKEUP AIR
REQUIREMENTS BASED ON HOOD DESIGN.
54. ELECTRICAL POWER DROP CORD FROM CEILING ABOVE. SEE
ELECTRICAL DRAWINGS.
10. CONTINUE POWER/CONDUIT COMING FROM UNDERSLAB UP
VERTICAL FACE OF GONDOLA SHELVING - RUN POWER IN
CONDUIT HORIZONTALLY AT TOP OF GONDOLA SHELVING TO
COFFEE GRINDER UNIT AT SOUTH END OF THIS AISLE.
COORDINATE WITH OWNER'S SHELVING/EQUIPMENT PLACEMENT
ON SITE.
55. GC PROVIDE WALL BLOCKING FOR WALL MOUNTED SHELVING/
EQUIPMENT. COORDINATE PLACEMENT WITH OWNER.
56. EXISTING WALL MOUNTED WOOD SHELF TO REMAIN. GC PAINT
SAME COLOR AS PLYWOOD. SEE FINISH SCHEDULE.
57. REFRIGERATION EQUIPMENT IN THIS AREA BY OTHERS.
58. AT PARTIAL HEIGHT WALL, PROVIDE 2" SQUARE STEEL TUBE
ANCHORED TO CONCRETE SLAB TO SUPPLEMENT LATERAL
SUPPORT OF PARTIAL HEIGHT WALL.
59. PROVIDE SOLID SURFACE WINDOW SILL AT EXISTING WINDOW.
CONFIRM COLOR SELECTION WITH ARCHITECT.
60. NEW WALK IN FREEZER PROVIDED BY OTHERS.
61. DEMO EXISTING STAIR TREAD FINISHES AND INSTALL NEW.
SEE FINISH SCHEDULE.
62. 2" X 2" STAINLESS STEEL CORNER GUARD FROM FLOOR TO
6'-0" A.F.F.
63. FULL HEIGHT (FLOOR TO CEILING) 2" X 2" STAINLESS STEEL
CORNER GUARD.
64. EXISTING DRAIN PIPE AND CLEANOUT TO REMAIN. BOX OUT
FRAMING AND FINISHES AROUND EXISTING PIPE.
65. NEW FLOOR MOUNTED GUARDRAIL. METAL PIPE RAILING - TOP
OF RAIL AT 42" A.F.F. PROVIDE ONE (1) HORIZONTAL PIPE AT
MIDPOINT AND ONE (1) TOP RAIL. PROVIDE INTERMEDIATE
VERTICALS AS REQUIRED. EPOXY ANCHOR TO EXISTING FLOOR
SLAB.
49
50
W11
BW1
(8) TYP.
GS5
GS5
GS5
GS5
2/A604
M24
M22
CO3
51 51
V4V5
V6
V7
52
BW1
(8) TYP.
F1
F2
F3
F3
F4
F5
F5
GS5
BW2
P12
P14
BR1
BR2
BR3
BR4
BR5 6/A6018
24
9
9
F6 GS8
CC8
6
6
6
6
9
W2
W3W5W5W7W7W20
W22 W22W23W24W25
W16W16 W16 W11W11W11
W11
W11W11W11 W12W16W16
W10 W11 W11W11W11
W11
W11
W11W12
W12
W11
W12
W11
W12
W12
W11
W11
W11
W12
W11
W11W24 W26
W26
W24 W28W29W29
W31W23
W23
W23
W32
W32
W32
W32
7
8
8
10
10
10
14
15
55
55
56
56
56
GS1015457
58
1/A6062
/
A
6
0
63/A606
4/A606 6/A606SEE INT. ELEVSA606 + F1/A611 (SIMI LAR)
SEE GS5/A613
SEE GS5/A613
SEE
GS5/A613
SEE GS5/A613
59
5959
626262
62
62
62
62
62
62
62
62
62
62
62
62
62
8
8
8
83/A6074/A607
4/A607 1/A609 1
1
1 1/A6091
#1 - 1.8.2021
PARTIAL HEIGHT "U" SHAPED
METAL FRAMED WALL WITH
GYPSUM BOARD ON BOTH SIDES
TO ENCLOSE MILLWORK.
COUNTER TOP TO CONTINUE OVER
MILLWORK AND PARTIAL HEIGHT
WALL.
5
#2 - 1.18.2021
BUILD NEW KNEE WALL
FROM TOP OF COOLER
UP TO DECK AT THIS LOCATION
1 LAYER OF GYPSUM BOARD
BOTH SIDES
6
PROVIDE FLOOR MOUNTED
4"X4" STEEL ANGLE ON 3 SIDES
TO ACT AS CART STOP IN
THIS AREA PAINT. VERIFY LAYOUT
WITH OWNER.
2
2
GS6
3
#3 - 1.29.2021
#5 - 2.25.2021
5
145D
5
1445
SEE GS5/A613
5
5
5
F3 AND F4 ARE CUSTOM
MILLWORK TO BE PROVIDED
AS PART OF GC MILLWORK
PACKAGE. SEE ELEVATIONS
5
5
INFILL EXISTING
OPENING WITH INSULATED
COOLER WALL PANEL.
PERMANENTLY CLOSE/
WELD DOOR CLOSED AS
THEY WILL NO LONGER
BE FUNCTIONAL.5/A606F7
SEE GS6/A613
156B
PARTIAL HEIGHT
WALL SURROUNDING
FLORAL MILLWORK
IS METAL STUD
FRAMED WALL WITH
FINISHED DRYWALL
ON ALL SIDES.
6
#6 - 3.5.2021
05/06/21