HomeMy WebLinkAbout12_A104R34 38 42 44 4645
A104R
FIRST FLOOR -
AREA 2 ENLARGED
REFERENCE PLAN
FIRST FLOOR - AREA 2 ENLARGED REFERENCE PLAN
SCALE: 3/16" = 1'-0"1N
PROJECT NUMBER:2020-007
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:
These drawings are intended for construction.
12.23.2020DATE ISSUED:
REVISIONS ISSUED:
CONSTRUCTION ISSUE SET
CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING
COLLABORATIVE
SAM HURT, P.E.
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, IN. 46241
PH: 317.636.3941
E-MAIL: sam@tec-mep.com
PROJECT CONTACT:
MEP ENGINEER:
KEY PLAN N
SCALE: 1/64" = 1'-0"
AREA 1
(A103)
AREA 2
(A104)
AREA 4
(A106)
AREA 3
(A105) MATCH LINEMATCH LINE MATCH LINEMATCH LINE
AREA 1 AREA 2
AREA 1 AREA 2
AREA NOT
IN SCOPE
EXTERIOR
MATCH LINE AREA 3 AREA 2AREA 3 AREA 2AREA NOT
IN SCOPE
EXTERIOR
EXTERIOR
SELF 1 SELF 2SELF 3 SELF 4CHECK OUT
104
CUSTOMER
SERVICE
107
CASH
OFFICE
108
VESTIBULE B
111
JAN
112
FROZEN
113
GENERAL
SHELVING
114
CS15
111A
111B 108
9
9
9
CO2
CO2
GS1
(31) TYP.
GS1
(32) TYP.
GS1
(28) TYP.
GS1
(28) TYP.
GS1
(30) TYP.
GS1
(30) TYP.
GS1
(10) TYP.
GS2
GS3
CS26
CS26 CS26
CS26 CS26CS26CS26CS26CS26CS27
8
CS28 CS28CS28
CS29
CS29
CS32 CS32
CS28
8
CS28 CS28CS30
8 8
F3
F2
F2
F2
F2
F2
F2
F2
F2
F1W7W6W2W2 W24
W9
W9
GENERAL PLAN NOTES:
FLOOR PLAN NOTES: X
1. EXISTING EXTERIOR SLIDING ENTRANCE DOORS INSTALLED AS
PART OF SHELL PACKAGE. NO GC WORK REQUIRED.
B. CONTRACTOR SHALL PROVIDE PHYSICAL SAMPLES AND SHOP
DRAWINGS FOR ALL FINISH MATERIALS TO ARCHITECT FOR
REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND
INSTALLATION.
A. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL
DISCREPANCIES ON DRAWINGS RELATIVE TO CONDITIONS IN THE
FIELD. REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO
PROCEEDING WITH WORK IN THE AFFECTED AREA.
2. NEW INTERIOR AUTOMATIC SLIDING DOOR PACKAGE AND
SIDELITE WINDOWS. SEE DOOR/WINDOW SCHEDULE.
3. FLOOR MOUNTED MOP SINK - SEE PLUMBING DRAWINGS.
4. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - LH.
SEE PLUMBING DWGS.
5. WALL MOUNTED HAND WASHING SINK. SEE PLUMBING DWGS.
6. ELECTRICAL FLOOR BOX - SEE ELECTRICAL DRAWINGS.
7. COUNTER MOUNTED SINK. SEE PLUMBING DWGS.
8. CUSTOM BUILT IN MILLWORK.
9. CUT EXISTING CONCRETE SLAB IN THIS AREA TO FEED POWER/
DATA OR REFRIGERANT LINES UNDER SLAB. APPROXIMATE
LOCATION SHOWN. GC SEE AND COORDINATE WITH
ELECTRICAL, PLUMBING, AND REFRIGERATION DRAWINGS.
(REFRIGERATION DRAWINGS BY OTHERS). VERIFY LOCATIONS IN
THE FIELD AND PROVIDE A SLAB CUT PLAN/LAYOUT FOR REVIEW
ON SITE PRIOR TO COMMENCING WITH SLAB CUTTING.
11. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - RH.
SEE PLUMBING DWGS.
12. FLOOR MOUNTED 3 COMPARTMENT SINK WITH DRAINBOARDS
ON BOTH ENDS. SEE PLUMBING DWGS.
13. EXISTING ELECTRICAL PANELS. SEE ELEC. DWGS.
14. NEW PLASTIC LAMINATE WORK COUNTER. SEE INTERIOR
ELEVATIONS.
15. EXISTING COOLER. NEW OPENING IN COOLER WALL AND DOOR
RELOCATION/INSTALLATION WORK BY OTHERS. COORDINATE
WITH OWNER.
16. FIVE (5) WALL MOUNTED COAT HOOKS ON EXISTING COOLER
WALL. COORDINATE LOCATION WITH OWNER.
17. EXISTING CURB AND DRAIN WASHOUT AREA TO REMAIN.
PROVIDE NEW DRAIN COVER AND VERIFY EXISTING DRAIN
FUNCTIONS PROPERLY.
18. EXISTING STRUCTURAL COLUMN TO REMAIN. PAINT.
REFERENCE FINISH PLAN FOR PAINT COLORS. OWNER
GONDOLA SHELVING INSTALLER TO COORDINATE MODIFICATION
TO SHELVING UNITS FOR INSTALLATION OF SHELVING AT
EXISTING COLUMNS
19. HAND SINK. DROP-IN - 12" WITH SPLASH GUARD. SEE PLUMBING
DWGS.
20. UTILITY SINK. DROP IN - 18"D X 18"W. SEE PLUMBING DWGS.
21. DIPPERWELL FAUCET AND SINK ASSEMBLY (FISHER 3041).
SEE PLUMBING DWGS.
22. 7" HIGH SNEEZE GUARD. SEE INTERIOR ELEVATIONS.
23. CUSTOM MILLWORK SWINGING GATE. SEE INTERIOR
ELEVATIONS.
24. ADA COMPLIANT UNDERMOUNT BREAK ROOM SINK.
SEE PLUMBING DWGS.
25. SEE MEP DWGS. FOR EQUIPMENT IN THIS AREA.
26. WHITE MELAMINE STORAGE SHELVES (2) ON ADJUSTABLE
STANDARDS. SEE INTERIOR ELEVATIONS.
27. 3-5/8" STEEL STUD PARTIAL HEIGHT WALL - FINISHED HEIGHT TO
TOP OF WALL CAP TO BE 4'-0" A.F.F. EMBED 2X2 STEEL TUBES
INTO SLAB TO REINFORCE WALL. SEE FINISH PLAN FOR WALL
AND CAP FINISH.
28. EXISTING WALL MOUNTED SHIP LADDER TO REMAIN.
29. DASHED LINE INDICATES LINE OF SECOND FLOOR MECHANICAL
AREA ABOVE.
30. EXISTING COOLER/FREEZER TO REMAIN.
31. EXISTING EXHAUST HOOD. REPAIR, REPLACE, AND CLEAN
EXISTING HOOD AND COMPONENTS AS NEEDED TO FULL
OPERATING CONDITION.
32. ONE COMPARTMENT FOOD PREP SINK - 30". SEE PLUMBING DWGS
33. NEW SOLID SURFACE LAVATORY COUNTER WITH INTEGRAL SINKS.
PROVIDE IN-WALL MOUNTED COUNTER SUPPORT BRACKETS
(RAKKS OR APPROVED EQUAL)WITH BLOCKING IN EXISTING WALL
AS REQ'D. PROVIDE REQUIRED ADA PROTECTION FOR WASTE
AND SUPPLY LINES.
34. BASIN-MOUNTED SOAP DISPENSER. (GOJO 8520-01).
35. AUTOMATIC SEMI-RECESSED ROLL TOWEL DISPENSER/WASTE
RECEPTACLE COMBINATION (GAMCO TW-14RP).
36. INDIVIDUAL FRAMELESS MIRRORS TO BE CENTERED ABOVE
EACH LAVATORY. SEE INTERIOR ELEVATIONS.
37. WALL MOUNTED ADA COMPLIANT URINAL FIXTURE. SEE
PLUMBING DRAWINGS.
39. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET
TISSUE DISPENSER. (GEORGIA PACIFIC COMPACT 2 ROLL
UNIT #56782).
40. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
41. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
42. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA.
(GAMCO 150C SERIES)
38. WALL MOUNTED SEAT PROTECTOR DISPENSER.
(BOBRICK B-221 SS).
44. SURFACE MOUNTED ADA COMPLIANT SANITARY NAPKIN
DISPOSAL. (GAMCO ND-5).
45. 5'-0" ADA TURNING CIRCLE SHOWN FOR REFERENCE. THIS IS NOT
A FLOOR PATTERN.
46. AUTOMATIC FAUCET, SEE PLUMBING DRAWINGS.
47. FLOOR MOUNTED TOILET FIXTURE, SEE PLUMBING DRAWINGS.
43. FLOOR MOUNTED, OVERHEAD BRACED PHENOLIC TOILET
PARTITIONS. PROVIDE A COAT HOOK ON INSIDE OF EACH
PARTITION DOOR CONTRACTOR TO PROVIDE WALL BLOCKING AS
REQUIRED. COLOR TO BE SELECTED BY ARCHITECT.
48. DRINKING FOUNTAIN. SEE PLUMBING DRAWINGS FOR SPEC. AND
ADA / STANDARD MOUNTING HEIGHT.
49. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
50. SURFACE MOUNTED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
51. OWNER PROVIDED/OWNER INSTALLED TV MONITOR. GC TO
PROVIDE POWER AND DATA ONLY TO THIS LOCATION. GC
COORDINATE POWER/DATA LOCATIONS WITH OWNER'S ARTWORK
PROVIDER/INSTALLER.
52. GRAPHICS/ARTWORK DISPLAY WALL TO BE PROVIDED AND
INSTALLED BY ARTWORK PROVIDER/INSTALLER. GC COORDINATE
WITH OWNER.
53. NEW EXHAUST HOOD - DESIGN AND INSTALLATION BY OTHERS.
COORDINATE WITH MEP ENGINEER FOR MAKEUP AIR
REQUIREMENTS BASED ON HOOD DESIGN.
54. ELECTRICAL POWER DROP CORD FROM CEILING ABOVE. SEE
ELECTRICAL DRAWINGS.
10. CONTINUE POWER/CONDUIT COMING FROM UNDERSLAB UP
VERTICAL FACE OF GONDOLA SHELVING - RUN POWER IN
CONDUIT HORIZONTALLY AT TOP OF GONDOLA SHELVING TO
COFFEE GRINDER UNIT AT SOUTH END OF THIS AISLE.
COORDINATE WITH OWNER'S SHELVING/EQUIPMENT PLACEMENT
ON SITE.
55. GC PROVIDE WALL BLOCKING FOR WALL MOUNTED SHELVING/
EQUIPMENT. COORDINATE PLACEMENT WITH OWNER.
56. EXISTING WALL MOUNTED WOOD SHELF TO REMAIN. GC PAINT
SAME COLOR AS PLYWOOD. SEE FINISH SCHEDULE.
57. REFRIGERATION EQUIPMENT IN THIS AREA BY OTHERS.
58. AT PARTIAL HEIGHT WALL, PROVIDE 2" SQUARE STEEL TUBE
ANCHORED TO CONCRETE SLAB TO SUPPLEMENT LATERAL
SUPPORT OF PARTIAL HEIGHT WALL.
59. PROVIDE SOLID SURFACE WINDOW SILL AT EXISTING WINDOW.
CONFIRM COLOR SELECTION WITH ARCHITECT.
60. NEW WALK IN FREEZER PROVIDED BY OTHERS.
61. DEMO EXISTING STAIR TREAD FINISHES AND INSTALL NEW.
SEE FINISH SCHEDULE.
62. 2" X 2" STAINLESS STEEL CORNER GUARD FROM FLOOR TO
6'-0" A.F.F.
63. FULL HEIGHT (FLOOR TO CEILING) 2" X 2" STAINLESS STEEL
CORNER GUARD.
64. EXISTING DRAIN PIPE AND CLEANOUT TO REMAIN. BOX OUT
FRAMING AND FINISHES AROUND EXISTING PIPE.
65. NEW FLOOR MOUNTED GUARDRAIL. METAL PIPE RAILING - TOP
OF RAIL AT 42" A.F.F. PROVIDE ONE (1) HORIZONTAL PIPE AT
MIDPOINT AND ONE (1) TOP RAIL. PROVIDE INTERMEDIATE
VERTICALS AS REQUIRED. EPOXY ANCHOR TO EXISTING FLOOR
SLAB.
W9
18
18 18 18
CS33
GS5 GS5
GS5
1/A604
2/A604
GS8
CO3
51
52
GS5 GS5
GS7
V3
LEMON'S
SEATING
105
LEMON'S
CUSTOMER LINE
106
110
LEMON'S F.O.H.
SERVICE
109
LEMON'S
B.O.H.
SERVICE
A107A
1 112
9
GS9
GS4
6
9 W7W34W35W5W5W34W34W35W35W35W35W35
7/A603 8/A6038/A603 1/A604
7/A6067/A606SEE INT. ELEVS
A606 + CS27/A611
SEE INT. ELEVS
A604 + CS30/A611
SEE GS3
ON A612
SEE GS5/A613 SEE GS5/A613
SEE GS5/A613
SEE GS5/A613 SEE GS5/A613
GS5
SEE GS5/A613
SEE GS4/A612
8 8
59 59 59 59 59 59 59 59 59
1
2
8
8
8 8
62 62 62
62
62
8
8
8
8 8
8
2/A607
1
1/A6071
#1 - 1.8.2021
3/A609
6
#2 - 1.18.2021
SEE GS7/A613
5
5
5
5
5 5
5
#5 - 2.25.2021
5
51/A610
2/A610
FUR OUT EXISTING
BLOCK DEMISING WALL
WITH 3 5/8" METAL STUDS
AND 5/8" GYPSUM BOARD
TERMINATE 6" ABOVE
FINISH CEILING.
FUR OUT EXISTING
BLOCK DEMISING WALL
WITH 3 5/8" METAL STUDS
AND TILE BACKER BOARD
TERMINATE 6" ABOVE
FINISH CEILING. INSTALL
TILE PER FINISH PLAN. #6 -3.5.2021
PARTIAL HEIGHT METAL
STUD WALL WITH TILE
BACKER BOARD AND TILE
FINISH.
05/06/21