Loading...
HomeMy WebLinkAbout14_A105R35 39 43 44 464532 33 37 41 42 40 36 A105R FIRST FLOOR AREA 3 ENLARGED REFERENCE PLAN FIRST FLOOR - AREA 3 ENLARGED REFERENCE PLAN SCALE: 3/16" = 1'-0"1N PROJECT NUMBER: 2020-007 CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. 12.23.2020DATE ISSUED: REVISIONS ISSUED: CONSTRUCTION ISSUE SET CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: BAKERY COOLER 129 KEY PLANN SCALE: 1/64" = 1'-0" AREA 1 (A103) AREA 2 (A104) AREA 4 (A106) AREA 3 (A105) AREA 4 AREA 3 AREA 3AREA 2 MATCH LINEMATCH LINEMATCH LINE AREA NOT IN SCOPE EXTERIOR EXTERIOR EXTERIOR EXTERIOR EXTERIOR EXTERIOR EXTERIOR FROZEN 113GENERAL SHELVING 114 DAIRY 120 DSD OFFICE 121 RACKING 122 COOLER 123 FREEZER 124 UTILITY 125 RECEIVING 126 BALER 127 CORRIDOR 128STAIR A STA-1 BAKERY/DELI FREEZER 130 BAKERY PREP 131 UP B6 B7 B6 B7 B6 122128B 128A127126A126B126C 124A123A124B1 2 5 129131 130 GS1 (11) TYP. GS1 (29) TYP. GS1 (29) TYP. GS1 (28) TYP. GS1 (28) TYP. GS1 (32) TYP. GS1 (32) TYP. F2 F2 F2 F2 F1 DR3 DR3 DR3 DR2 DR2 DR4 DR3 RK1 RK1 RK1 RK1 RK1 RK1 RK1 RK1 RK1 DSD1 DSD2 BL1 W9 W9 W17 W17W1318 18 W39W10W10W10W10 W10W10W10W10 W10W10 W16 W16W16 W10 W10W10W10 W11 W10 W11W11W10W11W11 W10W10W13W11 W11 W11 W18 W18W18 W18 DR1 13 1328 29 8 30 13 30 60 60 GENERAL PLAN NOTES: FLOOR PLAN NOTES: X 1. EXISTING EXTERIOR SLIDING ENTRANCE DOORS INSTALLED AS PART OF SHELL PACKAGE. NO GC WORK REQUIRED. B. CONTRACTOR SHALL PROVIDE PHYSICAL SAMPLES AND SHOP DRAWINGS FOR ALL FINISH MATERIALS TO ARCHITECT FOR REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND INSTALLATION. A. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL DISCREPANCIES ON DRAWINGS RELATIVE TO CONDITIONS IN THE FIELD. REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH WORK IN THE AFFECTED AREA. 2. NEW INTERIOR AUTOMATIC SLIDING DOOR PACKAGE AND SIDELITE WINDOWS. SEE DOOR/WINDOW SCHEDULE. 3. FLOOR MOUNTED MOP SINK - SEE PLUMBING DRAWINGS. 4. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - LH. SEE PLUMBING DWGS. 5. WALL MOUNTED HAND WASHING SINK. SEE PLUMBING DWGS. 6. ELECTRICAL FLOOR BOX - SEE ELECTRICAL DRAWINGS. 7. COUNTER MOUNTED SINK. SEE PLUMBING DWGS. 8. CUSTOM BUILT IN MILLWORK. 9. CUT EXISTING CONCRETE SLAB IN THIS AREA TO FEED POWER/ DATA OR REFRIGERANT LINES UNDER SLAB. APPROXIMATE LOCATION SHOWN. GC SEE AND COORDINATE WITH ELECTRICAL, PLUMBING, AND REFRIGERATION DRAWINGS. (REFRIGERATION DRAWINGS BY OTHERS). VERIFY LOCATIONS IN THE FIELD AND PROVIDE A SLAB CUT PLAN/LAYOUT FOR REVIEW 11. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - RH. SEE PLUMBING DWGS. 12. FLOOR MOUNTED 3 COMPARTMENT SINK WITH DRAINBOARDS ON BOTH ENDS. SEE PLUMBING DWGS. 13. EXISTING ELECTRICAL PANELS. SEE ELEC. DWGS. 14. NEW PLASTIC LAMINATE WORK COUNTER. SEE INTERIOR ELEVATIONS. 15. EXISTING COOLER. NEW OPENING IN COOLER WALL AND DOOR RELOCATION/INSTALLATION WORK BY OTHERS. COORDINATE WITH OWNER. 16. FIVE (5) WALL MOUNTED COAT HOOKS ON EXISTING COOLER WALL. COORDINATE LOCATION WITH OWNER. 17. EXISTING CURB AND DRAIN WASHOUT AREA TO REMAIN. PROVIDE NEW DRAIN COVER AND VERIFY EXISTING DRAIN FUNCTIONS PROPERLY. 18. EXISTING STRUCTURAL COLUMN TO REMAIN. PAINT. REFERENCE FINISH PLAN FOR PAINT COLORS. OWNER GONDOLA SHELVING INSTALLER TO COORDINATE MODIFICATION TO SHELVING UNITS FOR INSTALLATION OF SHELVING AT EXISTING COLUMNS 19. HAND SINK. DROP-IN - 12" WITH SPLASH GUARD. SEE PLUMBING DWGS. 20. UTILITY SINK. DROP IN - 18"D X 18"W. SEE PLUMBING DWGS. 10. CONTINUE POWER/CONDUIT COMING FROM UNDERSLAB UP VERTICAL FACE OF GONDOLA SHELVING - RUN POWER IN CONDUIT HORIZONTALLY AT TOP OF GONDOLA SHELVING TO COFFEE GRINDER UNIT AT SOUTH END OF THIS AISLE. COORDINATE WITH OWNER'S SHELVING/EQUIPMENT PLACEMENT ON SITE. 21. DIPPERWELL FAUCET AND SINK ASSEMBLY (FISHER 3041). SEE PLUMBING DWGS. 22. 7" HIGH SNEEZE GUARD. SEE INTERIOR ELEVATIONS. 23. CUSTOM MILLWORK SWINGING GATE. SEE INTERIOR ELEVATIONS. 24. ADA COMPLIANT UNDERMOUNT BREAK ROOM SINK. SEE PLUMBING DWGS. 25. SEE MEP DWGS. FOR EQUIPMENT IN THIS AREA. 26. WHITE MELAMINE STORAGE SHELVES (2) ON ADJUSTABLE STANDARDS. SEE INTERIOR ELEVATIONS. 27. 3-5/8" STEEL STUD PARTIAL HEIGHT WALL - FINISHED HEIGHT TO TOP OF WALL CAP TO BE 4'-0" A.F.F. EMBED 2X2 STEEL TUBES INTO SLAB TO REINFORCE WALL. SEE FINISH PLAN FOR WALL AND CAP FINISH. 28. EXISTING WALL MOUNTED SHIP LADDER TO REMAIN. 29. DASHED LINE INDICATES LINE OF SECOND FLOOR MECHANICAL AREA ABOVE. 30. EXISTING COOLER/FREEZER TO REMAIN. 31. EXISTING EXHAUST HOOD. REPAIR, REPLACE, AND CLEAN EXISTING HOOD AND COMPONENTS AS NEEDED TO FULL OPERATING CONDITION. 32. ONE COMPARTMENT FOOD PREP SINK - 30". SEE PLUMBING DWGS 33. NEW SOLID SURFACE LAVATORY COUNTER WITH INTEGRAL SINKS. PROVIDE IN-WALL MOUNTED COUNTER SUPPORT BRACKETS (RAKKS OR APPROVED EQUAL)WITH BLOCKING IN EXISTING WALL AS REQ'D. PROVIDE REQUIRED ADA PROTECTION FOR WASTE AND SUPPLY LINES. 34. BASIN-MOUNTED SOAP DISPENSER. (GOJO 8520-01). 50 50 35. AUTOMATIC SEMI-RECESSED ROLL TOWEL DISPENSER/WASTE RECEPTACLE COMBINATION (GAMCO TW-14RP). 36. INDIVIDUAL FRAMELESS MIRRORS TO BE CENTERED ABOVE EACH LAVATORY. SEE INTERIOR ELEVATIONS. 37. WALL MOUNTED ADA COMPLIANT URINAL FIXTURE. SEE PLUMBING DRAWINGS. 39. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET TISSUE DISPENSER. (GEORGIA PACIFIC COMPACT 2 ROLL UNIT #56782). 40. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA. (GAMCO 150C SERIES) 41. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA. (GAMCO 150C SERIES) 42. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA. (GAMCO 150C SERIES) 38. WALL MOUNTED SEAT PROTECTOR DISPENSER. (BOBRICK B-221 SS). 44. SURFACE MOUNTED ADA COMPLIANT SANITARY NAPKIN DISPOSAL. (GAMCO ND-5). 45. 5'-0" ADA TURNING CIRCLE SHOWN FOR REFERENCE. THIS IS NOT A FLOOR PATTERN. 46. AUTOMATIC FAUCET, SEE PLUMBING DRAWINGS. 47. FLOOR MOUNTED TOILET FIXTURE, SEE PLUMBING DRAWINGS. 43. FLOOR MOUNTED, OVERHEAD BRACED PHENOLIC TOILET PARTITIONS. PROVIDE A COAT HOOK ON INSIDE OF EACH PARTITION DOOR CONTRACTOR TO PROVIDE WALL BLOCKING AS REQUIRED. COLOR TO BE SELECTED BY ARCHITECT. 48. DRINKING FOUNTAIN. SEE PLUMBING DRAWINGS FOR SPEC. AND ADA / STANDARD MOUNTING HEIGHT. 49. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER. SEE LIFE SAFETY PLANS. 50. SURFACE MOUNTED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER. SEE LIFE SAFETY PLANS. 51. OWNER PROVIDED/OWNER INSTALLED TV MONITOR. GC TO PROVIDE POWER AND DATA ONLY TO THIS LOCATION. GC COORDINATE POWER/DATA LOCATIONS WITH OWNER'S ARTWORK PROVIDER/INSTALLER. 52. GRAPHICS/ARTWORK DISPLAY WALL TO BE PROVIDED AND INSTALLED BY ARTWORK PROVIDER/INSTALLER. GC COORDINATE WITH OWNER. 53. NEW EXHAUST HOOD - DESIGN AND INSTALLATION BY OTHERS. COORDINATE WITH MEP ENGINEER FOR MAKEUP AIR REQUIREMENTS BASED ON HOOD DESIGN. 54. ELECTRICAL POWER DROP CORD FROM CEILING ABOVE. SEE ELECTRICAL DRAWINGS. 55. GC PROVIDE WALL BLOCKING FOR WALL MOUNTED SHELVING/ EQUIPMENT. COORDINATE PLACEMENT WITH OWNER. 56. EXISTING WALL MOUNTED WOOD SHELF TO REMAIN. GC PAINT W11 W10W10W10 W11W11 W11W10W10W10W10W10 W10 W10 W10 W10 W10W10W11 W11 W11 W11W11W12W12 W12 W12W12 W13W13W13W15W13W13W13W14W14W14W14W16 4/A60258. AT PARTIAL HEIGHT WALL, PROVIDE 2" SQUARE STEEL TUBE ANCHORED TO CONCRETE SLAB TO SUPPLEMENT LATERAL SUPPORT OF PARTIAL HEIGHT WALL. 59. PROVIDE SOLID SURFACE WINDOW SILL AT EXISTING WINDOW. CONFIRM COLOR SELECTION WITH ARCHITECT. 60. NEW WALK IN FREEZER PROVIDED BY OTHERS. 61. DEMO EXISTING STAIR TREAD FINISHES AND INSTALL NEW. SEE FINISH SCHEDULE. 1 2 3 B 8 8 30 30 30 30 30 30 30 30 30 60 61 62 62 62 62. 2" X 2" STAINLESS STEEL CORNER GUARD FROM FLOOR TO 6'-0" A.F.F. 63. FULL HEIGHT (FLOOR TO CEILING) 2" X 2" STAINLESS STEEL CORNER GUARD. 64. EXISTING DRAIN PIPE AND CLEANOUT TO REMAIN. BOX OUT FRAMING AND FINISHES AROUND EXISTING PIPE. 65. NEW FLOOR MOUNTED GUARDRAIL. METAL PIPE RAILING - TOP OF RAIL AT 42" A.F.F. PROVIDE ONE (1) HORIZONTAL PIPE AT MIDPOINT AND ONE (1) TOP RAIL. PROVIDE INTERMEDIATE VERTICALS AS REQUIRED. EPOXY ANCHOR TO EXISTING FLOOR SLAB.1/A6071 1/A608 1 1/A608 1 #1 - 1.8.2021 GS5 SEE GS5/A613 5 #5 - 2.25.2021 6 6 #6 - 3.5.2021 05/06/21