HomeMy WebLinkAbout16_A106RA106R
FIRST FLOOR -
AREA 4 ENLARGED
REFERENCE PLAN
FIRST FLOOR - AREA 4 ENLARGED REFERENCE PLAN
SCALE: 3/16" = 1'-0"1N
PROJECT NUMBER: 2020-007
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:
These drawings are intended for construction.
12.23.2020DATE ISSUED:
REVISIONS ISSUED:
CONSTRUCTION ISSUE SET
CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING
COLLABORATIVE
SAM HURT, P.E.
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, IN. 46241
PH: 317.636.3941
E-MAIL: sam@tec-mep.com
PROJECT CONTACT:
MEP ENGINEER:
KEY PLANN
SCALE: 1/64" = 1'-0"
AREA 1
(A103)
AREA 2
(A104)
AREA 4
(A106)
AREA 3
(A105)
MATCH LINE MATCH LINEMATCH LINEMATCH LINEAREA 4 AREA 1AREA 4 AREA 1AREA 4 AREA 3
AREA 4 AREA 3
BAKERY
PREP
131
WASH
132
BAKERY
119
CHEESE
ISLAND
116
MEAT
117MEAT
COUNTER
142
CORR
139
MEAT
FREEZER
143
MEAT
COOLER
144
SEAFOOD
COOLER
141
SEAFOOD
PREP
140
MEN RR
137
WOMEN RR
138
CORR
136
DELI
COOLER
135
134
DELI
STOR
DELI
118
DELI PREP
133
STAIR A
STA-1
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
A107
1
C7
C6
C1
C5
C2
C3
C4
B11
B8
B9
B5
B9
B5
B4
B10
B2
D16
D1
D2
D19 D20
D21
D21 D21
D3D4
134135136A137
138 136B139141 143GENERAL PLAN NOTES:
FLOOR PLAN NOTES: X
1. EXISTING EXTERIOR SLIDING ENTRANCE DOORS INSTALLED AS
PART OF SHELL PACKAGE. NO GC WORK REQUIRED.
B. CONTRACTOR SHALL PROVIDE PHYSICAL SAMPLES AND SHOP
DRAWINGS FOR ALL FINISH MATERIALS TO ARCHITECT FOR
REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND
INSTALLATION.
A. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL
DISCREPANCIES ON DRAWINGS RELATIVE TO CONDITIONS IN THE
FIELD. REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO
PROCEEDING WITH WORK IN THE AFFECTED AREA.
2. NEW INTERIOR AUTOMATIC SLIDING DOOR PACKAGE AND
SIDELITE WINDOWS. SEE DOOR/WINDOW SCHEDULE.
3. FLOOR MOUNTED MOP SINK - SEE PLUMBING DRAWINGS.
4. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - LH.
SEE PLUMBING DWGS.
5. WALL MOUNTED HAND WASHING SINK. SEE PLUMBING DWGS.
6. ELECTRICAL FLOOR BOX - SEE ELECTRICAL DRAWINGS.
7. COUNTER MOUNTED SINK. SEE PLUMBING DWGS.
8. CUSTOM BUILT IN MILLWORK.
9. CUT EXISTING CONCRETE SLAB IN THIS AREA TO FEED POWER/
DATA OR REFRIGERANT LINES UNDER SLAB. APPROXIMATE
LOCATION SHOWN. GC SEE AND COORDINATE WITH
ELECTRICAL, PLUMBING, AND REFRIGERATION DRAWINGS.
(REFRIGERATION DRAWINGS BY OTHERS). VERIFY LOCATIONS IN
THE FIELD AND PROVIDE A SLAB CUT PLAN/LAYOUT FOR REVIEW
ON SITE PRIOR TO COMMENCING WITH SLAB CUTTING.
11. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - RH.
SEE PLUMBING DWGS.
12. FLOOR MOUNTED 3 COMPARTMENT SINK WITH DRAINBOARDS
ON BOTH ENDS. SEE PLUMBING DWGS.
13. EXISTING ELECTRICAL PANELS. SEE ELEC. DWGS.
14. NEW PLASTIC LAMINATE WORK COUNTER. SEE INTERIOR
ELEVATIONS.
15. EXISTING COOLER. NEW OPENING IN COOLER WALL AND DOOR
RELOCATION/INSTALLATION WORK BY OTHERS. COORDINATE
WITH OWNER.
16. FIVE (5) WALL MOUNTED COAT HOOKS ON EXISTING COOLER
WALL. COORDINATE LOCATION WITH OWNER.
17. EXISTING CURB AND DRAIN WASHOUT AREA TO REMAIN.
PROVIDE NEW DRAIN COVER AND VERIFY EXISTING DRAIN
FUNCTIONS PROPERLY.
18. EXISTING STRUCTURAL COLUMN TO REMAIN. PAINT.
REFERENCE FINISH PLAN FOR PAINT COLORS. OWNER
GONDOLA SHELVING INSTALLER TO COORDINATE MODIFICATION
TO SHELVING UNITS FOR INSTALLATION OF SHELVING AT
EXISTING COLUMNS
19. HAND SINK. DROP-IN - 12" WITH SPLASH GUARD. SEE PLUMBING
DWGS.
20. UTILITY SINK. DROP IN - 18"D X 18"W. SEE PLUMBING DWGS.
21. DIPPERWELL FAUCET AND SINK ASSEMBLY (FISHER 3041).
SEE PLUMBING DWGS.
22. 7" HIGH SNEEZE GUARD. SEE INTERIOR ELEVATIONS.
23. CUSTOM MILLWORK SWINGING GATE. SEE INTERIOR
ELEVATIONS.
24. ADA COMPLIANT UNDERMOUNT BREAK ROOM SINK.
SEE PLUMBING DWGS.
25. SEE MEP DWGS. FOR EQUIPMENT IN THIS AREA.
26. WHITE MELAMINE STORAGE SHELVES (2) ON ADJUSTABLE
STANDARDS. SEE INTERIOR ELEVATIONS.
27. 3-5/8" STEEL STUD PARTIAL HEIGHT WALL - FINISHED HEIGHT TO
TOP OF WALL CAP TO BE 4'-0" A.F.F. EMBED 2X2 STEEL TUBES
INTO SLAB TO REINFORCE WALL. SEE FINISH PLAN FOR WALL
AND CAP FINISH.
28. EXISTING WALL MOUNTED SHIP LADDER TO REMAIN.
29. DASHED LINE INDICATES LINE OF SECOND FLOOR MECHANICAL
AREA ABOVE.
30. EXISTING COOLER/FREEZER TO REMAIN.
31. EXISTING EXHAUST HOOD. REPAIR, REPLACE, AND CLEAN
EXISTING HOOD AND COMPONENTS AS NEEDED TO FULL
OPERATING CONDITION.
32. ONE COMPARTMENT FOOD PREP SINK - 30". SEE PLUMBING DWGS
33. NEW SOLID SURFACE LAVATORY COUNTER WITH INTEGRAL SINKS.
PROVIDE IN-WALL MOUNTED COUNTER SUPPORT BRACKETS
(RAKKS OR APPROVED EQUAL)WITH BLOCKING IN EXISTING WALL
AS REQ'D. PROVIDE REQUIRED ADA PROTECTION FOR WASTE
AND SUPPLY LINES.
34. BASIN-MOUNTED SOAP DISPENSER. (GOJO 8520-01).
35. AUTOMATIC SEMI-RECESSED ROLL TOWEL DISPENSER/WASTE
RECEPTACLE COMBINATION (GAMCO TW-14RP).
36. INDIVIDUAL FRAMELESS MIRRORS TO BE CENTERED ABOVE
EACH LAVATORY. SEE INTERIOR ELEVATIONS.
37. WALL MOUNTED ADA COMPLIANT URINAL FIXTURE. SEE
PLUMBING DRAWINGS.
39. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET
TISSUE DISPENSER. (GEORGIA PACIFIC COMPACT 2 ROLL
UNIT #56782).
40. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
41. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA.
(GAMCO 150C SERIES)
42. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA.
(GAMCO 150C SERIES)
38. WALL MOUNTED SEAT PROTECTOR DISPENSER.
(BOBRICK B-221 SS).
44. SURFACE MOUNTED ADA COMPLIANT SANITARY NAPKIN
DISPOSAL. (GAMCO ND-5).
45. 5'-0" ADA TURNING CIRCLE SHOWN FOR REFERENCE. THIS IS NOT
A FLOOR PATTERN.
46. AUTOMATIC FAUCET, SEE PLUMBING DRAWINGS.
47. FLOOR MOUNTED TOILET FIXTURE, SEE PLUMBING DRAWINGS.
43. FLOOR MOUNTED, OVERHEAD BRACED PHENOLIC TOILET
PARTITIONS. PROVIDE A COAT HOOK ON INSIDE OF EACH
PARTITION DOOR CONTRACTOR TO PROVIDE WALL BLOCKING AS
REQUIRED. COLOR TO BE SELECTED BY ARCHITECT.
48. DRINKING FOUNTAIN. SEE PLUMBING DRAWINGS FOR SPEC. AND
ADA / STANDARD MOUNTING HEIGHT.
49. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
50. SURFACE MOUNTED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER. SEE LIFE SAFETY PLANS.
51. OWNER PROVIDED/OWNER INSTALLED TV MONITOR. GC TO
PROVIDE POWER AND DATA ONLY TO THIS LOCATION. GC
COORDINATE POWER/DATA LOCATIONS WITH OWNER'S ARTWORK
PROVIDER/INSTALLER.
52. GRAPHICS/ARTWORK DISPLAY WALL TO BE PROVIDED AND
INSTALLED BY ARTWORK PROVIDER/INSTALLER. GC COORDINATE
WITH OWNER.
53. NEW EXHAUST HOOD - DESIGN AND INSTALLATION BY OTHERS.
COORDINATE WITH MEP ENGINEER FOR MAKEUP AIR
REQUIREMENTS BASED ON HOOD DESIGN.
54. ELECTRICAL POWER DROP CORD FROM CEILING ABOVE. SEE
ELECTRICAL DRAWINGS.
10. CONTINUE POWER/CONDUIT COMING FROM UNDERSLAB UP
VERTICAL FACE OF GONDOLA SHELVING - RUN POWER IN
CONDUIT HORIZONTALLY AT TOP OF GONDOLA SHELVING TO
COFFEE GRINDER UNIT AT SOUTH END OF THIS AISLE.
COORDINATE WITH OWNER'S SHELVING/EQUIPMENT PLACEMENT
ON SITE.
55. GC PROVIDE WALL BLOCKING FOR WALL MOUNTED SHELVING/
EQUIPMENT. COORDINATE PLACEMENT WITH OWNER.
56. EXISTING WALL MOUNTED WOOD SHELF TO REMAIN. GC PAINT
SAME COLOR AS PLYWOOD. SEE FINISH SCHEDULE.
57. REFRIGERATION EQUIPMENT IN THIS AREA BY OTHERS.
58. AT PARTIAL HEIGHT WALL, PROVIDE 2" SQUARE STEEL TUBE
ANCHORED TO CONCRETE SLAB TO SUPPLEMENT LATERAL
SUPPORT OF PARTIAL HEIGHT WALL.
59. PROVIDE SOLID SURFACE WINDOW SILL AT EXISTING WINDOW.
CONFIRM COLOR SELECTION WITH ARCHITECT.
60. NEW WALK IN FREEZER PROVIDED BY OTHERS.
61. DEMO EXISTING STAIR TREAD FINISHES AND INSTALL NEW.
SEE FINISH SCHEDULE.
62. 2" X 2" STAINLESS STEEL CORNER GUARD FROM FLOOR TO
6'-0" A.F.F.
63. FULL HEIGHT (FLOOR TO CEILING) 2" X 2" STAINLESS STEEL
CORNER GUARD.
64. EXISTING DRAIN PIPE AND CLEANOUT TO REMAIN. BOX OUT
FRAMING AND FINISHES AROUND EXISTING PIPE.
65. NEW FLOOR MOUNTED GUARDRAIL. METAL PIPE RAILING - TOP
OF RAIL AT 42" A.F.F. PROVIDE ONE (1) HORIZONTAL PIPE AT
MIDPOINT AND ONE (1) TOP RAIL. PROVIDE INTERMEDIATE
VERTICALS AS REQUIRED. EPOXY ANCHOR TO EXISTING FLOOR
SLAB.
B3
B9
125
D13
D30
D29 D28 D27
D17
D16
D26
B12
D24
D24 D23
D31
B13
B13
B14M3
M6
M6
M6
C7
W18
W18W1
8
W1
8
W18W18
W18 W18W10W10W10 W39W1W1W10
W32
W29 W2
9
W24
W248
W11
M24M23
S4
S3
S2 S1
S5
M25 W1554
8
53
4
325
5
32
13
W29
4
5
15
15
15
W10
18
18
50
W10C8
9 9
D21
D16 D18
D7 D15
D10 D9 D6 D11 D32
NEW EXHAUST HOOD.
10'-0"W X 5'-0"D SHOWN
CONTRACTOR PRICE
TYPE 1 AND TYPE 2
HOOD AT THIS LOCATION
FOR OWNER REVIEW/
COMPARISON
B1
54 W39W39W40W40W40W40W40W11 W11W11
W31
W3
1
W13W15W13W13W11 W11 W11W11W11
W11
W11W11W32
W32W29W28W28W281/A6052
/
A
6
0
53/A6054
/
A
6
0
5
4/A6083/A 60 8
GS11
8
5
32
6 6
15
2/A608
1
2/A608
12/A6091 2/A6091
#1 - 1.8.2021
5'-0" 1'-0"3
#2 - 1.18.2021
D14 D12
D5
D22D8
#3 - 1.29.2021
1
NEW EXHAUST HOOD.
16'-0"W X 5'-0"D SHOWN
TYPE 1 HOOD REQUIRED
AT THIS LOCATION
16'-0"
D16
5'-0" 1'-0"10'-0"53
6 144INFILL EXISTING
OPENING WITH INSULATED
COOLER WALL PANEL.
PERMANENTLY CLOSE/
WELD DOOR CLOSED AS
THEY WILL NO LONGER
BE FUNCTIONAL.
5
#5 - 2.25.2021
M26
B15
5
5
SEE GS11
ON A613
#6 - 3.5.2021
05/06/21