Loading...
HomeMy WebLinkAbout18_A107A107 ENLARGED FLOOR PLANS ENLARGED FIRST FLOOR RR PLAN SCALE: 1/2" = 1'-0"1N 3/A601 1/A601 46 PROJECT NUMBER: 2020-007 CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. 12.23.2020DATE ISSUED: REVISIONS ISSUED: CONSTRUCTION ISSUE SET CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: CORR 139 ENLARGED SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"2N ENLARGED SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"3N WOMEN RR 138 MEN RR 137 CORR 136 DELI PREP 133 DELI 118 PRICING COORDINATOR 202 NETWORK/ TELCO 203 CORRIDOR 201 STAIR A STA-2 OFFICE 204 MECH/ UTILITY 205 COMPRESSOR RACK A 206 AREA BELOW AREA BELOW AREA BELOW DOWN PC1 PC2 PC3 8 138 137 136A136B2022032041'-9"6'-0" 1'-8" 2'-8" 1'-8" 5'-1" 1'-4 1/2" 2'-8"1'-4 1/2" 5'-5" 5'-9" 8'-10"7'-6 1/2"8'-8 1/2"7'-4" 5'-7" 2'-0"2/A601 4/A601 4/A601 5/A6013436 46 34 36 33 35 45 2'-2"3'-0"5'-0"39 3847 38 47 40 44 39 42 41 45 43 43 43 48 48 45 46 34 36 46 34 36 33 37 39 42 41 4547 4038 10'-11"19'-4"2'-0"12'-0"9'-7" 9'-10" 21'-0"3'-8" 14'-10 1/2"3'-0" GENERAL PLAN NOTES: FLOOR PLAN NOTES: X 1. EXISTING EXTERIOR SLIDING ENTRANCE DOORS INSTALLED AS PART OF SHELL PACKAGE. NO GC WORK REQUIRED. B. CONTRACTOR SHALL PROVIDE PHYSICAL SAMPLES AND SHOP DRAWINGS FOR ALL FINISH MATERIALS TO ARCHITECT FOR REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND INSTALLATION. A. NOTIFY ARCHITECT OF ANY DIMENSIONAL OR PHYSICAL DISCREPANCIES ON DRAWINGS RELATIVE TO CONDITIONS IN THE FIELD. REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH WORK IN THE AFFECTED AREA. 2. NEW INTERIOR AUTOMATIC SLIDING DOOR PACKAGE AND SIDELITE WINDOWS. SEE DOOR/WINDOW SCHEDULE. 3. FLOOR MOUNTED MOP SINK - SEE PLUMBING DRAWINGS. 4. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - LH. SEE PLUMBING DWGS. 5. WALL MOUNTED HAND WASHING SINK. SEE PLUMBING DWGS. 6. ELECTRICAL FLOOR BOX - SEE ELECTRICAL DRAWINGS. 7. COUNTER MOUNTED SINK. SEE PLUMBING DWGS. 8. CUSTOM BUILT IN MILLWORK. 9. CUT EXISTING CONCRETE SLAB IN THIS AREA TO FEED POWER/ DATA OR REFRIGERANT LINES UNDER SLAB. APPROXIMATE LOCATION SHOWN. GC SEE AND COORDINATE WITH ELECTRICAL, PLUMBING, AND REFRIGERATION DRAWINGS. (REFRIGERATION DRAWINGS BY OTHERS). VERIFY LOCATIONS IN THE FIELD AND PROVIDE A SLAB CUT PLAN/LAYOUT FOR REVIEW ON SITE PRIOR TO COMMENCING WITH SLAB CUTTING. 11. FLOOR MOUNTED 1 COMPARTMENT SINK WITH DRAINBOARD - RH. SEE PLUMBING DWGS. 12. FLOOR MOUNTED 3 COMPARTMENT SINK WITH DRAINBOARDS ON BOTH ENDS. SEE PLUMBING DWGS. 13. EXISTING ELECTRICAL PANELS. SEE ELEC. DWGS. 14. NEW PLASTIC LAMINATE WORK COUNTER. SEE INTERIOR ELEVATIONS. 15. EXISTING COOLER. NEW OPENING IN COOLER WALL AND DOOR RELOCATION/INSTALLATION WORK BY OTHERS. COORDINATE WITH OWNER. 16. FIVE (5) WALL MOUNTED COAT HOOKS ON EXISTING COOLER WALL. COORDINATE LOCATION WITH OWNER. 17. EXISTING CURB AND DRAIN WASHOUT AREA TO REMAIN. PROVIDE NEW DRAIN COVER AND VERIFY EXISTING DRAIN FUNCTIONS PROPERLY. 18. EXISTING STRUCTURAL COLUMN TO REMAIN. PAINT. REFERENCE FINISH PLAN FOR PAINT COLORS. OWNER GONDOLA SHELVING INSTALLER TO COORDINATE MODIFICATION TO SHELVING UNITS FOR INSTALLATION OF SHELVING AT EXISTING COLUMNS 19. HAND SINK. DROP-IN - 12" WITH SPLASH GUARD. SEE PLUMBING DWGS. 20. UTILITY SINK. DROP IN - 18"D X 18"W. SEE PLUMBING DWGS. 21. DIPPERWELL FAUCET AND SINK ASSEMBLY (FISHER 3041). SEE PLUMBING DWGS. 22. 7" HIGH SNEEZE GUARD. SEE INTERIOR ELEVATIONS. 23. CUSTOM MILLWORK SWINGING GATE. SEE INTERIOR ELEVATIONS. 24. ADA COMPLIANT UNDERMOUNT BREAK ROOM SINK. SEE PLUMBING DWGS. 25. SEE MEP DWGS. FOR EQUIPMENT IN THIS AREA. 26. WHITE MELAMINE STORAGE SHELVES (2) ON ADJUSTABLE STANDARDS. SEE INTERIOR ELEVATIONS. 27. 3-5/8" STEEL STUD PARTIAL HEIGHT WALL - FINISHED HEIGHT TO TOP OF WALL CAP TO BE 4'-0" A.F.F. EMBED 2X2 STEEL TUBES INTO SLAB TO REINFORCE WALL. SEE FINISH PLAN FOR WALL AND CAP FINISH. 28. EXISTING WALL MOUNTED SHIP LADDER TO REMAIN. 29. DASHED LINE INDICATES LINE OF SECOND FLOOR MECHANICAL AREA ABOVE. 30. EXISTING COOLER/FREEZER TO REMAIN. 31. EXISTING EXHAUST HOOD. REPAIR, REPLACE, AND CLEAN EXISTING HOOD AND COMPONENTS AS NEEDED TO FULL OPERATING CONDITION. 32. ONE COMPARTMENT FOOD PREP SINK - 30". SEE PLUMBING DWGS 33. NEW SOLID SURFACE LAVATORY COUNTER WITH INTEGRAL SINKS. PROVIDE IN-WALL MOUNTED COUNTER SUPPORT BRACKETS (RAKKS OR APPROVED EQUAL)WITH BLOCKING IN EXISTING WALL AS REQ'D. PROVIDE REQUIRED ADA PROTECTION FOR WASTE AND SUPPLY LINES. 34. BASIN-MOUNTED SOAP DISPENSER. (GOJO 8520-01). 35. AUTOMATIC SEMI-RECESSED ROLL TOWEL DISPENSER/WASTE RECEPTACLE COMBINATION (GAMCO TW-14RP). 36. INDIVIDUAL FRAMELESS MIRRORS TO BE CENTERED ABOVE EACH LAVATORY. SEE INTERIOR ELEVATIONS. 37. WALL MOUNTED ADA COMPLIANT URINAL FIXTURE. SEE PLUMBING DRAWINGS. 39. SURFACE MOUNTED ADA COMPLIANT DOUBLE ROLL TOILET TISSUE DISPENSER. (GEORGIA PACIFIC COMPACT 2 ROLL UNIT #56782). 40. NEW WALL MOUNTED ADA GRAB BAR - 36" HORIZONTAL - 1.5" DIA. (GAMCO 150C SERIES) 41. NEW WALL MOUNTED ADA GRAB BAR - 42" HORIZONTAL - 1.5" DIA. (GAMCO 150C SERIES) 42. NEW WALL MOUNTED ADA GRAB BAR - 18" VERTICAL - 1.5" DIA. (GAMCO 150C SERIES) 38. WALL MOUNTED SEAT PROTECTOR DISPENSER. (BOBRICK B-221 SS). 44. SURFACE MOUNTED ADA COMPLIANT SANITARY NAPKIN DISPOSAL. (GAMCO ND-5). 45. 5'-0" ADA TURNING CIRCLE SHOWN FOR REFERENCE. THIS IS NOT A FLOOR PATTERN. 46. AUTOMATIC FAUCET, SEE PLUMBING DRAWINGS. 47. FLOOR MOUNTED TOILET FIXTURE, SEE PLUMBING DRAWINGS. 43. FLOOR MOUNTED, OVERHEAD BRACED PHENOLIC TOILET PARTITIONS. PROVIDE A COAT HOOK ON INSIDE OF EACH PARTITION DOOR CONTRACTOR TO PROVIDE WALL BLOCKING AS REQUIRED. COLOR TO BE SELECTED BY ARCHITECT. 48. DRINKING FOUNTAIN. SEE PLUMBING DRAWINGS FOR SPEC. AND ADA / STANDARD MOUNTING HEIGHT. 49. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER. SEE LIFE SAFETY PLANS. 50. SURFACE MOUNTED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER. SEE LIFE SAFETY PLANS. 51. OWNER PROVIDED/OWNER INSTALLED TV MONITOR. GC TO PROVIDE POWER AND DATA ONLY TO THIS LOCATION. GC COORDINATE POWER/DATA LOCATIONS WITH OWNER'S ARTWORK PROVIDER/INSTALLER. 52. GRAPHICS/ARTWORK DISPLAY WALL TO BE PROVIDED AND INSTALLED BY ARTWORK PROVIDER/INSTALLER. GC COORDINATE WITH OWNER. 53. NEW EXHAUST HOOD - DESIGN AND INSTALLATION BY OTHERS. COORDINATE WITH MEP ENGINEER FOR MAKEUP AIR REQUIREMENTS BASED ON HOOD DESIGN. 54. ELECTRICAL POWER DROP CORD FROM CEILING ABOVE. SEE ELECTRICAL DRAWINGS. 10. CONTINUE POWER/CONDUIT COMING FROM UNDERSLAB UP VERTICAL FACE OF GONDOLA SHELVING - RUN POWER IN CONDUIT HORIZONTALLY AT TOP OF GONDOLA SHELVING TO COFFEE GRINDER UNIT AT SOUTH END OF THIS AISLE. COORDINATE WITH OWNER'S SHELVING/EQUIPMENT PLACEMENT ON SITE. 55. GC PROVIDE WALL BLOCKING FOR WALL MOUNTED SHELVING/ EQUIPMENT. COORDINATE PLACEMENT WITH OWNER. 56. EXISTING WALL MOUNTED WOOD SHELF TO REMAIN. GC PAINT SAME COLOR AS PLYWOOD. SEE FINISH SCHEDULE. 57. REFRIGERATION EQUIPMENT IN THIS AREA BY OTHERS. 58. AT PARTIAL HEIGHT WALL, PROVIDE 2" SQUARE STEEL TUBE ANCHORED TO CONCRETE SLAB TO SUPPLEMENT LATERAL SUPPORT OF PARTIAL HEIGHT WALL. 59. PROVIDE SOLID SURFACE WINDOW SILL AT EXISTING WINDOW. CONFIRM COLOR SELECTION WITH ARCHITECT. 60. NEW WALK IN FREEZER PROVIDED BY OTHERS. 61. DEMO EXISTING STAIR TREAD FINISHES AND INSTALL NEW. SEE FINISH SCHEDULE. 62. 2" X 2" STAINLESS STEEL CORNER GUARD FROM FLOOR TO 6'-0" A.F.F. 63. FULL HEIGHT (FLOOR TO CEILING) 2" X 2" STAINLESS STEEL CORNER GUARD. 64. EXISTING DRAIN PIPE AND CLEANOUT TO REMAIN. BOX OUT FRAMING AND FINISHES AROUND EXISTING PIPE. 65. NEW FLOOR MOUNTED GUARDRAIL. METAL PIPE RAILING - TOP OF RAIL AT 42" A.F.F. PROVIDE ONE (1) HORIZONTAL PIPE AT MIDPOINT AND ONE (1) TOP RAIL. PROVIDE INTERMEDIATE VERTICALS AS REQUIRED. EPOXY ANCHOR TO EXISTING FLOOR SLAB.W29W29 W37W32W40 W37W2 4W24W24 W1 W10W1050 205W10W10 W10 60 EXISTING WALL MOUNTED SHIP LADDER TO REMAIN SECOND FLOOR FINISH SCHEDULE STA-2 STAIR A ROOM PT-01 WALL RB-01 BASE FLOOR COMMENTS 201 CORRIDOR 202 PRICING COORDINATOR 203 NETWORK/TELCO 204 OFFICE 205 MECH / UTILITY PT-01 RB-01 PC-01 PT-01 RB-01 PC-01 PT-01 RB-01 PC-01 AREA TO REMAIN AS-IS 206 COMPRESSOR RACK A AREA TO REMAIN AS-IS NOTE: SEE FINISH SCHEDULE FOR FINISH TYPES. 45 35 43 43 DEMO EXTERIOR WALL AS REQUIRED TO INSTALL NEW LOUVER PER MECHANICAL DRAWINGS. COORDINATE SIZE WITH MECHANICAL AND ARCHITECT.W29W29W29 W29 W29 W37 W29 W24 W24W24 W37W37 W40 W40 W32W32W41 W413'-0" 4 1/2" 1'-6" 5'-2" 1'-7" 44 4'-2 1/2"3'-11 1/2"3'-2" 4'-3"4'-3"4'-11 1/2"4'-3 1/2"7'-4 1/2"64 65 16'-4" 3'-0"AREA TO REMAIN AS IS NO NEW FINISHES IN THIS AREA W10W10 IN ROOMS 201, 202, AND 203: PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. REFINISH AND PAINT PER FINISH SCHEDULE.4/A609#1 - 1.8.20212/A6091 -- -- -- -- -- -- NEW RUBBER STAIR TREAD/RISERS 1 WATER HEATERS 204A 8 PC1 PC35/A6091/A6102/A610 204A OF1 OF2 OF1 OF2 8 W16 W16 W166 #5 - 2.25.2021 5'-0 1/2" 11'-6" 16'-10" ALIGN 3'-9 1/2"3'-0" 6'-4" 6'-8"FIELD COORDINATE SPECIFIC DIMENSIONS FOR THIS ROOM RELATIVE TO ON SITE SIZES AND PLACEMENT OF NEW WATER HEATERS AND INFRASTRUCTURE AND ALLOWING FOR ACCESS FOR MAINTENANCE. COORDINATE FINAL DIMENSIONS WITH OWNER. 204A WATER HEATERS PT-01 RB-01 PC-01 PT-01 RB-01 PC-01 5W22 #6 - 3.5.2021 05/06/21