Loading...
HomeMy WebLinkAbout20_A108A108 WALL TYPES PROJECT NUMBER: 2020-007 CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. 12.23.2020DATE ISSUED: REVISIONS ISSUED: CONSTRUCTION ISSUE SET CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: EXISTING EXTERIOR WALL WITH EXISTING GYPSUM BOARD FINISH. GC COORDINATE WITH ELECTRICAL + PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD. FINISH AND PAINT PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W1 WALL TYPES: GENERAL NOTES: 1. WHERE TILE IS SHOWN ON WALLS ON INTERIOR ELEVATIONS AND FINISH PLANS, REPLACE GYPSUM BOARD IN TILE AREA WITH TILE BACKER BOARD. MAINTAIN FIRE RATING WHERE REQUIRED. 2. REFERENCE LIFE SAFETY PLANS FOR WALL RATINGS/SEPARATIONS - NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN LIFE SAFETY PLAN AND WALL TYPE TAGS ON PLANS FOR CLARIFICATION PRIOR TO CONSTRUCTION. REFINISH EXISTING GYPSUM BOARD EXISTING EXTERIOR WALL EXISTING STEEL COLUMN EXISTING WOOD FRAMING NEW 5/8" GYP BD W2 EXISTING EXTERIOR WALL AT EXISTING STEEL COLUMN. EXISTING WOOD FRAMING AT COLUMN TO REMAIN. GC INSTALL NEW 5/8" GYPSUM BOARD ON EXISTING WOOD FRAMING - EXTEND TO 6" ABOVE FINISH CEILING HEIGHT. GC FINISH AND PAINT PER FINISH SCHEDULE. EXISTING EXTERIOR WALL. EXISTING WOOD FRAMING AND INSULATION IS EXPOSED. GC INSTALL NEW 5/8" GYPSUM BOARD IN THIS AREA - EXTEND DRYWALL TO 6" ABOVE FINISH CEILING. GC FINISH AND PAINT PER FINISH SCHEDULE. REFERENCE FINISH PLAN AND INTERIOR ELEVATIONS. IN AREAS OF TILE WALL FINISH, REPLACE GYPSUM BOARD WITH TILE BACKER BOARD. EXISTING EXTERIOR WALL W3 INSTALL NEW GYP BD ON EXISTING WD FRAMING EXISTING EXTERIOR WALL EXISTING BRICK COLUMN WRAP W4 EXISTING EXTERIOR WALL AND EXISTING EXPOSED BRICK COLUMN WRAP. EXISTING EXPOSED BRICK TO REMAIN AT THIS LOCATION. GC PREP AND PAINT EXISTING BRICK PER FINISH SCHEDULE. EXISTING EXTERIOR WALL. NEW GYPSUM BOARD RECENTLY INSTALLED AS PART OF BUILDING SHELL PACKAGE WORK. GC COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ANY ADDITIONAL FINISHES ON THIS WALL. EXISTING EXTERIOR WALL W5 NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING EXTERIOR WALL EXISTING BRICK COLUMN WRAP W6 EXISTING EXTERIOR WALL AND EXISTING EXPOSED BRICK COLUMN WRAP. GC INSTALL NEW 2 1/2" METAL FRAMING AROUND EXISTING BRICK COLUMN TO FUR OUT AT COLUMN. INSTALL NEW 5/8" GYPSUM BOARD ON METAL FRAMING. METAL STUD AND GYPSUM BOARD TO CONTINUE UP TO STRUCTURE ABOVE. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ANY ADDITIONAL FINISHES ON THIS WALL.2 1/2"5/8"GC DEMO EXISTING GYPSUM BOARD IN THIS AREA DOWN TO EXISTING EXTERIOR WALL FRAMING. GC INSTALL NEW 5/ 8" GYPSUM BOARD ON EXISTING FRAMING - EXTEND TO BOTTOM OF STRUCTURE/HEIGHT OF ADJACENT GYPSUM BOARD FINISH. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL. EXISTING EXTERIOR WALL W7 INSTALL NEW GYP BD ON EXISTING WD FRAMING EXISTING CMU DEMISING WALL WITH EXPOSED WOOD FURRING. GC SUPPLEMENT WOOD FURRING AS REQUIRED TO PROVIDE SUFFICIENT SUBSTRATE FOR NEW GYPSUM BOARD. INSTALL NEW 5/8" GYPSUM BOARD TO 6" ABOVE NEW CEILING HEIGHT. SEE FINISH SCHEDULE FOR ADDITIONAL WALL FINISHES ON THIS WALL. EXISTING CMU DEMISING WALL W8 INSTALL NEW GYP BD ON EXISTING WD FRAMING EXISTING WOOD FURRING W9 EXISTING CMU DEMISING WALL NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING CMU DEMISING WALL. NEW GYPSUM BOARD RECENTLY INSTALLED AS PART OF BUILDING SHELL PACKAGE WORK. GC COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. FINISH AND PAINT PER FINISH SCHEDULE. W9A EXISTING CMU DEMISING WALL NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING CMU DEMISING WALL. NEW GYPSUM BOARD RECENTLY INSTALLED AS PART OF BUILDING SHELL PACKAGE WORK. GC COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. GC INSTALL NEW STAINLESS STEEL PANEL OVER DRYWALL IN THIS AREA FROM FLOOR TO BOTTOM OF NEW EXHAUST HOOD. NEW STAINLESS STEEL PANEL AT NEW HOOD W9C EXISTING CMU DEMISING WALL NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING CMU DEMISING WALL. NEW GYPSUM BOARD RECENTLY INSTALLED AS PART OF BUILDING SHELL PACKAGE WORK. COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. FINISH AND PAINT PER FINISH SCHEDULE. INSTALL NEW FRP PANLE FROM FLOOR TO CEILING PANEL OVER DRYWALL IN NEW MOP SINK AREA. NEW FRP PANEL AT NEW MOP SINK W10 EXISTING CMU WALL EXISTING CMU. GC PREP EXISTING SURFACE FOR NEW PAINT. GC PAINT WALL FROM FLOOR TO STRUCTURE ABOVE PER FINISH SCHEDULE. PAINT EXISTING CMU ONLY W11 EXISTING COOLER/ FREEZER WALL EXISTING COOLER/FREEZER WALL. NO GC WORK OR FINISHES REQUIRED. W12 NEW COOLER/ FREEZER WALL NEW COOLER/FREEZER WALL BY OTHERS. NO GC WORK OR FINISHES REQUIRED. EXISTING WALL W13 NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING WOOD STUD WALL WITH NEW GYPSUM BOARD INSTALLED AS PART OF SHELL PACKAGE. GC COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS. EXISTING WALL W14 GC INSTALL NEW 5/8" PLYWOOD ON EXISTING STUDS EXISTING WOOD STUD WALL - EXPOSED STUDS ON THIS SIDE OF WALL. GC INSTALL NEW 5/8" PLYWOOD ON EXISTING WOOD STUDS FROM FLOOR UP TO STRUCTURE ABOVE OR TO EXISTING GYPSUM BOARD FINISH. PAINT PER FINISH SCHEDULE. W15 AT EXISTING OPENING, GC TO INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO HEAD OF EXISTING OPENING. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES OF WALL - FINISH FLUSH WITH ADJACENT EXISTING GYPSUM BOARD WALL FINISHES. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS.3 5/8" 5/8"5/8" W16 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO EXISTING STRUCTURE ABOVE. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES OF WALL - CONTINUE GYPSUM BOARD FINISH UP TO EXPOSED STRUCTURE ABOVE IN EXPOSED CEILING AREAS. EXTEND GYPSUM BOARD TO 6" ABOVE FINISH CEILINGS IN SPACES WHERE THERE ARE DROP/FINISH CEILINGS. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS.3 5/8" 5/8"5/8" W17 GC TO INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO EXISTING STRUCTURE ABOVE. INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON ROOM FINISH SIDE OF WALL - CONTINUE GYPSUM BOARD FINISH UP TO EXPOSED STRUCTURE ABOVE. FINISH AND PAINT PER FINISH SCHEDULE.3 5/8" 5/8" EXISTING EXTERIOR WALL WITH EXISTING GYPSUM BOARD FINISH. GC COORDINATE WITH ELECTRICAL + PLUMBING DRAWINGS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD. GC INSTALL NEW FRP PANEL OVER GYPSUM BOARD FROM FLOOR TO CEILING. SEE FINISH SCHEDULE. EXISTING EXTERIOR WALL W19 EXISTING GYPSUM BOARD NEW FRP PANEL EXISTING BRICK EXTERIOR WALL. GC INSTALL NEW 2 1/2" METAL STUDS AT 16" O.C. TO FUR OUT EXISTING WALL - CONTINUE STUDS TO 6" ABOVE NEW CEILING HEIGHT. GC INSTALL NEW 5/8" GYPSUM BOARD OVER METAL STUDS - CONTINUE TO 6" ABOVE NEW CEILING HEIGHT. GC INSTALL NEW FRP PANEL FROM FLOOR TO CEILING OVER GYPSUM BOARD. SEE FINISH SCHEDULE. EXISTING EXTERIOR WALL W20 NEW 5/8" GYP BD NEW FRP PANEL 2 1/2"5/8" 2 1/2" METAL STUD EXISTING CMU EXTERIOR WALL. GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. TO FUR OUT EXISTING WALL - CONTINUE STUDS TO 6" ABOVE NEW CEILING HEIGHT. GC INSTALL NEW 5/8" GYPSUM BOARD OVER METAL STUDS - CONTINUE TO 6" ABOVE NEW CEILING HEIGHT. GC INSTALL NEW FRP PANEL FROM FLOOR TO CEILING OVER GYPSUM BOARD. SEE FINISH SCHEDULE. EXISTING EXTERIOR WALL W21 NEW 5/8" GYP BD NEW FRP PANEL 3 5/8"5/8"3 5/8" METAL STUD EXISTING CMU EXTERIOR WALL. GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. TO FUR OUT EXISTING WALL - CONTINUE STUDS TO 6" ABOVE NEW CEILING HEIGHT. GC INSTALL NEW 5/8" GYPSUM BOARD OVER METAL STUDS - CONTINUE TO 6" ABOVE NEW CEILING HEIGHT. GC FINISH AND PAINT GYPSUM BOARD PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W22 NEW 5/8" GYP BD 3 5/8"5/8"3 5/8" METAL STUD W23 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO EXISTING STRUCTURE ABOVE. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON ROOM FINISH SIDE OF WALL (NOT COOLER SIDE) - CONTINUE GYPSUM BOARD TO 6" ABOVE FINISH CEILING HEIGHT OR TO STRUCTURE ABOVE IN AREAS WITH NO FINISH CEILING. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS.3 5/8" 5/8" W24 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR 6" ABOVE FINISH CEILING HEIGHT - BRACE BACK TO STRUCTURE AT MIN. 4'-0" O.C. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES OF WALL - CONTINUE GYPSUM BOARD FINISH UP TO 6" ABOVE CEILING HEIGHT. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS.3 5/8" 5/8" 5/8" 5/8"3 5/8" METAL STUD NEW 5/8" GYP BD NEW 5/8" GYP BD 3 5/8" METAL STUD W25 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR 6" ABOVE FINISH CEILING HEIGHT - BRACE BACK TO STRUCTURE AT MIN. 4'-0" O.C. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES OF WALL - CONTINUE GYPSUM BOARD FINISH UP TO 6" ABOVE CEILING HEIGHT. GC FINISH AND PAINT GYPSUM BOARD PER FINISH SCHEDULE. GC INSTALL FRP PANEL FROM FLOOR TO CEILING ON PRODUCE PREP SIDE OF WALL. SEE FINISH SCHEDULE.3 5/8" 5/8"5/8" NEW 5/8" GYP BD 3 5/8" METAL STUD NEW FRP PANEL W26 EXISTING COOLER/ FREEZER WALL EXISTING COOLER/FREEZER WALL WITH EXISTING WOOD FURRING AND PLYWOOD FINISH. GC PREP AND PAINT PLYWOOD ONLY. NEW 5/8" GYP BD 2 1/2" METAL STUD W9B EXISTING CMU DEMISING WALL NEW GYP BD INSTALLED IN SHELL PACKAGE EXISTING CMU DEMISING WALL. NEW GYPSUM BOARD RECENTLY INSTALLED AS PART OF BUILDING SHELL PACKAGE WORK. GC COORDINATE WITH ELECTRICAL AND PLUMBING PLANS ON ANY NEW INFRASTRUCTURE IN THIS WALL AND CUT OUT EXISTING DRYWALL AS REQUIRED TO ACCOMMODATE NEW INFRASTRUCTURE. GC PATCH AND REPAIR EXISTING GYPSUM BOARD AS REQUIRED. GC INSTALL NEW 1/2" TILE BACKER BOARD OVER EXISTING GYPSUM BOARD - EXTEND TO CEILING. GC INSTALL TILE FROM FLOOR TO CEILING PER FINISHE PLAN. NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W18 GC TO INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO EXISTING STRUCTURE ABOVE. INSTALL 1 LAYER OF 1/2" TILE BACKER BOARD ON ROOM FINISH SIDE OF WALL - CONTINUE FROM FLOOR TO STRUCTURE ABOVE. GC INSTALL TILE PER FINISH SCHEDULE FROM FLOOR TO STRUCTURE ABOVE.3 5/8" NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD EXISTING WALL W27 GC INSTALL NEW 5/8" GYP BD ON EXISTING STUDS EXISTING WOOD STUD WALL TO REMAIN. GC INSTALL NEW 5/8" GYPSUM BOARD ON EXISTING WOOD STUDS FROM FLOOR UP TO 6" ABOVE FINISH CEILING HEIGHT. GC PAINT PER FINISH SCHEDULE. W28 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO 6" ABOVE CEILING HEIGHT. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON ROOM FINISH SIDE OF WALL (NOT COOLER SIDE) - CONTINUE GYPSUM BOARD TO 6" ABOVE FINISH CEILING HEIGHT. GC FINISH AND PAINT PER FINISH SCHEDULE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS WALL IN SOME AREAS.3 5/8" 5/8"3 5/8" METAL STUD NEW 5/8" GYP BD W29 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO 6" ABOVE CEILING HEIGHT. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON ONE SIDE OF WALL - CONTINUE GYPSUM BOARD TO 6" ABOVE FINISH CEILING HEIGHT. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS SIDE OF WALL. ON CHOP SHOP/LEMON'S/DELI SIDE/RESTROOM SIDE OF WALL, GC INSTALL 1/2" TILE BACKER BOARD FROM FLOOR TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL TILE PER FINISH PLAN.3 5/8" 5/8" 3 5/8" METAL STUD NEW 5/8" GYP BD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W30 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO STRUCTURE ABOVE. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON VESTIBULE SIDE OF WALL - CONTINUE GYPSUM BOARD TO 6" ABOVE FINISH CEILING HEIGHT. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS SIDE OF WALL. ON CHOP SHOP SIDE OF WALL, GC INSTALL 1/2" TILE BACKER BOARD FROM FLOOR TO STRUCTURE ABOVE. GC INSTALL TILE PER FINISH PLAN.3 5/8" 5/8" 3 5/8" METAL STUD NEW 5/8" GYP BD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W31 PARTIAL HEIGHT WALL - TOP OF WALL CAP TO FINISH AT 4'-0" A.F.F. GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. GC INSTALL 2" STEEL SUPPORT TUBES ANCHORED TO CONCRETE SLAB AS INDICATED ON FLOOR PLAN. GC INSTALL 1 LAYER OF 1/2" TILE BACKER BOARD ON BOTH SIDES OF WALL. GC INSTALL WALL TILE AND FINISH CAP PER FINISH PLAN.3 5/8" 3 5/8" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W32 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL 1 LAYER OF 1/2" TILE BACKER BOARD ON ROOM FINISH SIDE OF WALL (NOT COOLER SIDE) - CONTINUE BACKER BOARD TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL TILE FROM FLOOR TO CEILING PER FINISH SCHEDULE.3 5/8" 3 5/8" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD EXISTING COOLER WALL EXISTING STEEL COLUMN EXISTING WOOD FRAMING NEW TILE BACKER BOARD W33 EXISTING COOLER WALL AT EXISTING STEEL COLUMN. EXISTING WOOD FRAMING AT COLUMN TO REMAIN. GC INSTALL NEW 1/2" TILE BACKER BOARD ON EXISTING WOOD FRAMING - EXTEND TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL WALL TILE FROM FLOOR TO CEILING PER FINISH SCHEDULE. NEW TILE EXISTING EXTERIOR WALL. EXISTING WOOD FRAMING AND INSULATION IS EXPOSED. GC INSTALL NEW 1/2" TILE BACKER BOARD ON EXISTING WOOD FRAMING. EXTEND TILE BACKER BOARD TO TILE HEIGHT INDICATED ON INTERIOR ELEVATIONS. ABOVE TILE HEIGHT, GC INSTALL 5/8" GYPSUM BOARD FROM TOP OF TILE TO STRUCTURE ABOVE. GC INSTALL TILE ON BACKER BOARD AND PAINT GYPSUM BOARD PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W34 NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD EXISTING EXTERIOR WALL. EXISTING WOOD FRAMING AND INSULATION IS EXPOSED. GC INSTALL NEW 1/2" TILE BACKER BOARD ON EXISTING WOOD FRAMING. EXTEND TILE BACKER BOARD TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL TILE FROM FLOOR TO CEILING HEIGHT PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W35 NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W36 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO STRUCTURE ABOVE. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON GENERAL SHELVING SIDE OF WALL - EXTEND TO STRUCTURE ABOVE. SEE FINISH SCHEDULE FOR ADDITIONAL FINISHES ON THIS SIDE OF WALL. ON LEMON'S SIDE OF WALL, GC INSTALL 1/2" TILE BACKER BOARD FROM FLOOR TO 6" ABOVE FINISH CEILING. GC INSTALL TILE PER FINISH PLAN.3 5/8" 5/8"3 5/8" METAL STUD NEW 5/8" GYP BD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W37 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. EXTEND STUDS TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL 1 LAYER OF 1/2" TILE BACKER BOARD ON BOTH SIDES OF WALL. GC INSTALL WALL TILE FROM FLOOR TO CEILING PER FINISH SCHEDULE.3 5/8" 3 5/8" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W38 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR 6" ABOVE FINISH CEILING HEIGHT - BRACE BACK TO STRUCTURE AT MIN. 4'-0" O.C. GC INSTALL 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES OF WALL - CONTINUE GYPSUM BOARD FINISH UP TO 6" ABOVE CEILING HEIGHT. GC FINISH AND PAINT GYPSUM BOARD PER FINISH SCHEDULE. GC INSTALL STAINLESS STEEL PANEL FROM FLOOR TO CEILING IN EXHAUST HOOD AREA. SEE FINISH SCHEDULE.3 5/8" 5/8"5/8" NEW 5/8" GYP BD 3 5/8" METAL STUD NEW STAINLESS STEEL PANEL EXISTING EXTERIOR CMU WALL WITH EXISTING 3 5/8" METAL STUD FURRING IN PLACE TO REMAIN. GC INSTALL NEW 1/2" TILE BACKER BOARD FROM FLOOR TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL WALL TILE PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W39 3 5/8" EXIST 3 5/8" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD EXISTING EXTERIOR CMU WALL. GC INSTALL NEW 3 5/8" METAL STUD FURRING TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL NEW 1/2" TILE BACKER BOARD FROM FLOOR TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL WALL TILE PER FINISH SCHEDULE. EXISTING EXTERIOR WALL W40 3 5/8" EXIST 3 5/8" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD W41 GC INSTALL NEW 3 5/8" METAL STUDS AT 16" O.C. FROM FLOOR TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL 1 LAYER OF 1/2" TILE BACKER BOARD ON ROOM FINISH SIDE OF WALL (NOT COOLER SIDE) - CONTINUE BACKER BOARD TO 6" ABOVE FINISH CEILING HEIGHT. GC INSTALL TILE FROM FLOOR TO CEILING PER FINISH SCHEDULE. 2 1/2" METAL STUD NEW TILE PER FINISH SCHEDULE NEW TILE BACKER BOARD 05/06/21