HomeMy WebLinkAbout20_A108A108
WALL TYPES
PROJECT NUMBER: 2020-007
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:
These drawings are intended for construction.
12.23.2020DATE ISSUED:
REVISIONS ISSUED:
CONSTRUCTION ISSUE SET
CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING
COLLABORATIVE
SAM HURT, P.E.
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, IN. 46241
PH: 317.636.3941
E-MAIL: sam@tec-mep.com
PROJECT CONTACT:
MEP ENGINEER:
EXISTING EXTERIOR WALL WITH
EXISTING GYPSUM BOARD FINISH.
GC COORDINATE WITH ELECTRICAL +
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD.
FINISH AND PAINT PER FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W1
WALL TYPES:
GENERAL NOTES:
1. WHERE TILE IS SHOWN ON WALLS ON INTERIOR ELEVATIONS AND
FINISH PLANS, REPLACE GYPSUM BOARD IN TILE AREA WITH TILE
BACKER BOARD. MAINTAIN FIRE RATING WHERE REQUIRED.
2. REFERENCE LIFE SAFETY PLANS FOR WALL
RATINGS/SEPARATIONS - NOTIFY ARCHITECT OF ANY
DISCREPANCIES BETWEEN LIFE SAFETY PLAN AND WALL TYPE
TAGS ON PLANS FOR CLARIFICATION PRIOR TO CONSTRUCTION.
REFINISH EXISTING
GYPSUM BOARD
EXISTING EXTERIOR WALL
EXISTING
STEEL
COLUMN
EXISTING
WOOD
FRAMING
NEW
5/8"
GYP BD
W2
EXISTING EXTERIOR WALL AT
EXISTING STEEL COLUMN. EXISTING
WOOD FRAMING AT COLUMN TO
REMAIN. GC INSTALL NEW 5/8"
GYPSUM BOARD ON EXISTING WOOD
FRAMING - EXTEND TO 6" ABOVE
FINISH CEILING HEIGHT. GC FINISH
AND PAINT PER FINISH SCHEDULE.
EXISTING EXTERIOR WALL. EXISTING
WOOD FRAMING AND INSULATION IS
EXPOSED. GC INSTALL NEW 5/8"
GYPSUM BOARD IN THIS AREA -
EXTEND DRYWALL TO 6" ABOVE
FINISH CEILING. GC FINISH AND
PAINT PER FINISH SCHEDULE.
REFERENCE FINISH PLAN AND
INTERIOR ELEVATIONS. IN AREAS OF
TILE WALL FINISH, REPLACE GYPSUM
BOARD WITH TILE BACKER BOARD.
EXISTING EXTERIOR WALL
W3
INSTALL NEW
GYP BD ON
EXISTING WD
FRAMING
EXISTING EXTERIOR WALL
EXISTING
BRICK
COLUMN
WRAP
W4
EXISTING EXTERIOR WALL AND
EXISTING EXPOSED BRICK COLUMN
WRAP. EXISTING EXPOSED BRICK TO
REMAIN AT THIS LOCATION. GC PREP
AND PAINT EXISTING BRICK PER
FINISH SCHEDULE.
EXISTING EXTERIOR WALL. NEW
GYPSUM BOARD RECENTLY
INSTALLED AS PART OF BUILDING
SHELL PACKAGE WORK. GC
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD
AS REQUIRED. GC FINISH AND PAINT
PER FINISH SCHEDULE. SEE FINISH
SCHEDULE FOR ANY ADDITIONAL
FINISHES ON THIS WALL.
EXISTING EXTERIOR WALL
W5
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING EXTERIOR WALL
EXISTING
BRICK
COLUMN
WRAP
W6
EXISTING EXTERIOR WALL AND
EXISTING EXPOSED BRICK COLUMN
WRAP. GC INSTALL NEW 2 1/2" METAL
FRAMING AROUND EXISTING BRICK
COLUMN TO FUR OUT AT COLUMN.
INSTALL NEW 5/8" GYPSUM BOARD ON
METAL FRAMING. METAL STUD AND
GYPSUM BOARD TO CONTINUE UP TO
STRUCTURE ABOVE. GC FINISH AND
PAINT PER FINISH SCHEDULE. SEE
FINISH SCHEDULE FOR ANY
ADDITIONAL FINISHES ON THIS WALL.2 1/2"5/8"GC DEMO EXISTING GYPSUM BOARD
IN THIS AREA DOWN TO EXISTING
EXTERIOR WALL FRAMING. GC
INSTALL NEW 5/ 8" GYPSUM BOARD
ON EXISTING FRAMING - EXTEND TO
BOTTOM OF STRUCTURE/HEIGHT OF
ADJACENT GYPSUM BOARD FINISH.
GC FINISH AND PAINT PER FINISH
SCHEDULE. SEE FINISH SCHEDULE
FOR ADDITIONAL FINISHES ON THIS
WALL.
EXISTING EXTERIOR WALL
W7
INSTALL NEW
GYP BD ON
EXISTING WD
FRAMING
EXISTING CMU DEMISING WALL WITH
EXPOSED WOOD FURRING. GC
SUPPLEMENT WOOD FURRING AS
REQUIRED TO PROVIDE SUFFICIENT
SUBSTRATE FOR NEW GYPSUM
BOARD. INSTALL NEW 5/8" GYPSUM
BOARD TO 6" ABOVE NEW CEILING
HEIGHT. SEE FINISH SCHEDULE FOR
ADDITIONAL WALL FINISHES ON THIS
WALL.
EXISTING CMU DEMISING WALL
W8
INSTALL NEW
GYP BD ON
EXISTING WD
FRAMING
EXISTING
WOOD
FURRING
W9
EXISTING CMU DEMISING WALL
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING CMU DEMISING WALL. NEW
GYPSUM BOARD RECENTLY
INSTALLED AS PART OF BUILDING
SHELL PACKAGE WORK. GC
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD AS
REQUIRED. FINISH AND PAINT PER
FINISH SCHEDULE.
W9A
EXISTING CMU DEMISING WALL
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING CMU DEMISING WALL. NEW
GYPSUM BOARD RECENTLY
INSTALLED AS PART OF BUILDING
SHELL PACKAGE WORK. GC
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD AS
REQUIRED. GC INSTALL NEW
STAINLESS STEEL PANEL OVER
DRYWALL IN THIS AREA FROM FLOOR
TO BOTTOM OF NEW EXHAUST
HOOD.
NEW STAINLESS
STEEL PANEL
AT NEW HOOD
W9C
EXISTING CMU DEMISING WALL
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING CMU DEMISING WALL. NEW
GYPSUM BOARD RECENTLY
INSTALLED AS PART OF BUILDING
SHELL PACKAGE WORK.
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. PATCH AND
REPAIR EXISTING GYPSUM BOARD AS
REQUIRED. FINISH AND PAINT PER
FINISH SCHEDULE. INSTALL NEW
FRP PANLE FROM FLOOR TO CEILING
PANEL OVER DRYWALL IN NEW MOP
SINK AREA.
NEW FRP PANEL
AT NEW MOP
SINK
W10
EXISTING CMU WALL
EXISTING CMU. GC PREP EXISTING
SURFACE FOR NEW PAINT. GC PAINT
WALL FROM FLOOR TO STRUCTURE
ABOVE PER FINISH SCHEDULE.
PAINT EXISTING
CMU ONLY
W11
EXISTING COOLER/
FREEZER WALL
EXISTING COOLER/FREEZER WALL.
NO GC WORK OR FINISHES
REQUIRED.
W12
NEW COOLER/
FREEZER WALL
NEW COOLER/FREEZER WALL BY
OTHERS. NO GC WORK OR FINISHES
REQUIRED.
EXISTING WALL
W13
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING WOOD STUD WALL WITH
NEW GYPSUM BOARD INSTALLED AS
PART OF SHELL PACKAGE. GC
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. PATCH AND
REPAIR EXISTING GYPSUM BOARD
AS REQUIRED. GC FINISH AND PAINT
PER FINISH SCHEDULE. SEE FINISH
SCHEDULE FOR ADDITIONAL FINISHES
ON THIS WALL IN SOME AREAS.
EXISTING WALL
W14
GC INSTALL
NEW 5/8" PLYWOOD
ON EXISTING STUDS
EXISTING WOOD STUD WALL -
EXPOSED STUDS ON THIS SIDE OF
WALL. GC INSTALL NEW 5/8"
PLYWOOD ON EXISTING WOOD
STUDS FROM FLOOR UP TO
STRUCTURE ABOVE OR TO EXISTING
GYPSUM BOARD FINISH. PAINT PER
FINISH SCHEDULE.
W15
AT EXISTING OPENING, GC TO
INSTALL NEW 3 5/8" METAL STUDS AT
16" O.C. FROM FLOOR TO HEAD OF
EXISTING OPENING. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
BOTH SIDES OF WALL - FINISH FLUSH
WITH ADJACENT EXISTING GYPSUM
BOARD WALL FINISHES. GC FINISH
AND PAINT PER FINISH SCHEDULE.
SEE FINISH SCHEDULE FOR
ADDITIONAL FINISHES ON THIS WALL
IN SOME AREAS.3 5/8" 5/8"5/8" W16 GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO EXISTING
STRUCTURE ABOVE. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
BOTH SIDES OF WALL - CONTINUE
GYPSUM BOARD FINISH UP TO
EXPOSED STRUCTURE ABOVE IN
EXPOSED CEILING AREAS.
EXTEND GYPSUM BOARD TO 6"
ABOVE FINISH CEILINGS IN SPACES
WHERE THERE ARE DROP/FINISH
CEILINGS. GC FINISH AND PAINT PER
FINISH SCHEDULE. SEE FINISH
SCHEDULE FOR ADDITIONAL FINISHES
ON THIS WALL IN SOME AREAS.3 5/8" 5/8"5/8" W17
GC TO INSTALL NEW 3 5/8" METAL
STUDS AT 16" O.C. FROM FLOOR TO
EXISTING STRUCTURE ABOVE.
INSTALL 1 LAYER OF 5/8" GYPSUM
BOARD ON ROOM FINISH SIDE OF
WALL - CONTINUE GYPSUM BOARD
FINISH UP TO EXPOSED STRUCTURE
ABOVE. FINISH AND PAINT PER
FINISH SCHEDULE.3 5/8" 5/8" EXISTING EXTERIOR WALL WITH
EXISTING GYPSUM BOARD FINISH.
GC COORDINATE WITH ELECTRICAL +
PLUMBING DRAWINGS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD.
GC INSTALL NEW FRP PANEL OVER
GYPSUM BOARD FROM FLOOR TO
CEILING. SEE FINISH SCHEDULE.
EXISTING EXTERIOR WALL
W19
EXISTING
GYPSUM BOARD
NEW FRP PANEL
EXISTING BRICK EXTERIOR WALL. GC
INSTALL NEW 2 1/2" METAL STUDS AT
16" O.C. TO FUR OUT EXISTING WALL -
CONTINUE STUDS TO 6" ABOVE NEW
CEILING HEIGHT. GC INSTALL NEW
5/8" GYPSUM BOARD OVER METAL
STUDS - CONTINUE TO 6" ABOVE NEW
CEILING HEIGHT. GC INSTALL NEW
FRP PANEL FROM FLOOR TO CEILING
OVER GYPSUM BOARD. SEE FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W20
NEW 5/8"
GYP BD
NEW FRP PANEL 2 1/2"5/8" 2 1/2"
METAL
STUD
EXISTING CMU EXTERIOR WALL. GC
INSTALL NEW 3 5/8" METAL STUDS AT
16" O.C. TO FUR OUT EXISTING WALL -
CONTINUE STUDS TO 6" ABOVE NEW
CEILING HEIGHT. GC INSTALL NEW
5/8" GYPSUM BOARD OVER METAL
STUDS - CONTINUE TO 6" ABOVE NEW
CEILING HEIGHT. GC INSTALL NEW
FRP PANEL FROM FLOOR TO CEILING
OVER GYPSUM BOARD. SEE FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W21
NEW 5/8"
GYP BD
NEW FRP PANEL 3 5/8"5/8"3 5/8"
METAL
STUD
EXISTING CMU EXTERIOR WALL. GC
INSTALL NEW 3 5/8" METAL STUDS AT
16" O.C. TO FUR OUT EXISTING WALL -
CONTINUE STUDS TO 6" ABOVE NEW
CEILING HEIGHT. GC INSTALL NEW
5/8" GYPSUM BOARD OVER METAL
STUDS - CONTINUE TO 6" ABOVE NEW
CEILING HEIGHT. GC FINISH AND
PAINT GYPSUM BOARD PER FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W22
NEW 5/8"
GYP BD 3 5/8"5/8"3 5/8"
METAL
STUD
W23
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO EXISTING
STRUCTURE ABOVE. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
ROOM FINISH SIDE OF WALL (NOT
COOLER SIDE) - CONTINUE GYPSUM
BOARD TO 6" ABOVE FINISH CEILING
HEIGHT OR TO STRUCTURE ABOVE IN
AREAS WITH NO FINISH CEILING. GC
FINISH AND PAINT PER FINISH
SCHEDULE. SEE FINISH SCHEDULE
FOR ADDITIONAL FINISHES ON THIS
WALL IN SOME AREAS.3 5/8" 5/8" W24
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR 6" ABOVE
FINISH CEILING HEIGHT - BRACE BACK
TO STRUCTURE AT MIN. 4'-0" O.C. GC
INSTALL 1 LAYER OF 5/8" GYPSUM
BOARD ON BOTH SIDES OF WALL -
CONTINUE GYPSUM BOARD FINISH UP
TO 6" ABOVE CEILING HEIGHT. GC
FINISH AND PAINT PER FINISH
SCHEDULE. SEE FINISH SCHEDULE
FOR ADDITIONAL FINISHES ON THIS
WALL IN SOME AREAS.3 5/8" 5/8" 5/8" 5/8"3 5/8"
METAL
STUD
NEW 5/8"
GYP BD
NEW 5/8"
GYP BD
3 5/8"
METAL
STUD
W25
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR 6" ABOVE
FINISH CEILING HEIGHT - BRACE BACK
TO STRUCTURE AT MIN. 4'-0" O.C. GC
INSTALL 1 LAYER OF 5/8" GYPSUM
BOARD ON BOTH SIDES OF WALL -
CONTINUE GYPSUM BOARD FINISH UP
TO 6" ABOVE CEILING HEIGHT. GC
FINISH AND PAINT GYPSUM BOARD
PER FINISH SCHEDULE. GC INSTALL
FRP PANEL FROM FLOOR TO CEILING
ON PRODUCE PREP SIDE OF WALL.
SEE FINISH SCHEDULE.3 5/8" 5/8"5/8" NEW 5/8"
GYP BD
3 5/8"
METAL
STUD
NEW FRP
PANEL
W26
EXISTING COOLER/
FREEZER WALL
EXISTING COOLER/FREEZER WALL
WITH EXISTING WOOD FURRING AND
PLYWOOD FINISH. GC PREP AND
PAINT PLYWOOD ONLY.
NEW 5/8"
GYP BD
2 1/2"
METAL
STUD
W9B
EXISTING CMU DEMISING WALL
NEW GYP BD
INSTALLED IN
SHELL PACKAGE
EXISTING CMU DEMISING WALL. NEW
GYPSUM BOARD RECENTLY
INSTALLED AS PART OF BUILDING
SHELL PACKAGE WORK. GC
COORDINATE WITH ELECTRICAL AND
PLUMBING PLANS ON ANY NEW
INFRASTRUCTURE IN THIS WALL AND
CUT OUT EXISTING DRYWALL AS
REQUIRED TO ACCOMMODATE NEW
INFRASTRUCTURE. GC PATCH AND
REPAIR EXISTING GYPSUM BOARD AS
REQUIRED. GC INSTALL NEW 1/2"
TILE BACKER BOARD OVER EXISTING
GYPSUM BOARD - EXTEND TO
CEILING. GC INSTALL TILE FROM
FLOOR TO CEILING PER FINISHE
PLAN.
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W18
GC TO INSTALL NEW 3 5/8" METAL
STUDS AT 16" O.C. FROM FLOOR TO
EXISTING STRUCTURE ABOVE.
INSTALL 1 LAYER OF 1/2" TILE BACKER
BOARD ON ROOM FINISH SIDE OF
WALL - CONTINUE FROM FLOOR TO
STRUCTURE ABOVE. GC INSTALL TILE
PER FINISH SCHEDULE FROM FLOOR
TO STRUCTURE ABOVE.3 5/8" NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
EXISTING WALL
W27
GC INSTALL
NEW 5/8" GYP BD
ON EXISTING STUDS
EXISTING WOOD STUD WALL TO
REMAIN. GC INSTALL NEW 5/8"
GYPSUM BOARD ON EXISTING WOOD
STUDS FROM FLOOR UP TO 6" ABOVE
FINISH CEILING HEIGHT. GC PAINT
PER FINISH SCHEDULE.
W28 GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO 6" ABOVE
CEILING HEIGHT. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
ROOM FINISH SIDE OF WALL (NOT
COOLER SIDE) - CONTINUE GYPSUM
BOARD TO 6" ABOVE FINISH CEILING
HEIGHT. GC FINISH AND PAINT PER
FINISH SCHEDULE. SEE FINISH
SCHEDULE FOR ADDITIONAL FINISHES
ON THIS WALL IN SOME AREAS.3 5/8" 5/8"3 5/8"
METAL
STUD
NEW 5/8"
GYP BD
W29
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO 6" ABOVE
CEILING HEIGHT. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
ONE SIDE OF WALL - CONTINUE
GYPSUM BOARD TO 6" ABOVE FINISH
CEILING HEIGHT. SEE FINISH
SCHEDULE FOR ADDITIONAL FINISHES
ON THIS SIDE OF WALL.
ON CHOP SHOP/LEMON'S/DELI
SIDE/RESTROOM SIDE OF WALL, GC
INSTALL 1/2" TILE BACKER BOARD
FROM FLOOR TO 6" ABOVE FINISH
CEILING HEIGHT. GC INSTALL TILE
PER FINISH PLAN.3 5/8" 5/8" 3 5/8"
METAL
STUD
NEW 5/8"
GYP BD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W30
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO
STRUCTURE ABOVE. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
VESTIBULE SIDE OF WALL - CONTINUE
GYPSUM BOARD TO 6" ABOVE FINISH
CEILING HEIGHT. SEE FINISH
SCHEDULE FOR ADDITIONAL FINISHES
ON THIS SIDE OF WALL.
ON CHOP SHOP SIDE OF WALL, GC
INSTALL 1/2" TILE BACKER BOARD
FROM FLOOR TO STRUCTURE ABOVE.
GC INSTALL TILE PER FINISH PLAN.3 5/8" 5/8" 3 5/8"
METAL
STUD
NEW 5/8"
GYP BD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W31
PARTIAL HEIGHT WALL - TOP OF WALL
CAP TO FINISH AT 4'-0" A.F.F.
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. GC INSTALL 2" STEEL
SUPPORT TUBES ANCHORED TO
CONCRETE SLAB AS INDICATED ON
FLOOR PLAN. GC INSTALL 1 LAYER
OF 1/2" TILE BACKER BOARD ON BOTH
SIDES OF WALL. GC INSTALL WALL
TILE AND FINISH CAP PER FINISH
PLAN.3 5/8" 3 5/8"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W32
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO 6" ABOVE
FINISH CEILING HEIGHT. GC INSTALL 1
LAYER OF 1/2" TILE BACKER BOARD
ON ROOM FINISH SIDE OF WALL (NOT
COOLER SIDE) - CONTINUE BACKER
BOARD TO 6" ABOVE FINISH CEILING
HEIGHT. GC INSTALL TILE FROM
FLOOR TO CEILING PER FINISH
SCHEDULE.3 5/8" 3 5/8"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
EXISTING COOLER WALL
EXISTING
STEEL
COLUMN
EXISTING
WOOD
FRAMING
NEW
TILE
BACKER
BOARD
W33
EXISTING COOLER WALL AT EXISTING
STEEL COLUMN. EXISTING WOOD
FRAMING AT COLUMN TO REMAIN. GC
INSTALL NEW 1/2" TILE BACKER
BOARD ON EXISTING WOOD FRAMING
- EXTEND TO 6" ABOVE FINISH
CEILING HEIGHT. GC INSTALL WALL
TILE FROM FLOOR TO CEILING PER
FINISH SCHEDULE.
NEW
TILE
EXISTING EXTERIOR WALL. EXISTING
WOOD FRAMING AND INSULATION IS
EXPOSED. GC INSTALL NEW 1/2" TILE
BACKER BOARD ON EXISTING WOOD
FRAMING. EXTEND TILE BACKER
BOARD TO TILE HEIGHT INDICATED
ON INTERIOR ELEVATIONS. ABOVE
TILE HEIGHT, GC INSTALL 5/8"
GYPSUM BOARD FROM TOP OF TILE
TO STRUCTURE ABOVE. GC INSTALL
TILE ON BACKER BOARD AND PAINT
GYPSUM BOARD PER FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W34
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
EXISTING EXTERIOR WALL. EXISTING
WOOD FRAMING AND INSULATION IS
EXPOSED. GC INSTALL NEW 1/2" TILE
BACKER BOARD ON EXISTING WOOD
FRAMING. EXTEND TILE BACKER
BOARD TO 6" ABOVE FINISH CEILING
HEIGHT. GC INSTALL TILE FROM
FLOOR TO CEILING HEIGHT PER
FINISH SCHEDULE.
EXISTING EXTERIOR WALL
W35
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W36
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO
STRUCTURE ABOVE. GC INSTALL 1
LAYER OF 5/8" GYPSUM BOARD ON
GENERAL SHELVING SIDE OF WALL -
EXTEND TO STRUCTURE ABOVE. SEE
FINISH SCHEDULE FOR ADDITIONAL
FINISHES ON THIS SIDE OF WALL.
ON LEMON'S SIDE OF WALL, GC
INSTALL 1/2" TILE BACKER BOARD
FROM FLOOR TO 6" ABOVE FINISH
CEILING. GC INSTALL TILE PER FINISH
PLAN.3 5/8" 5/8"3 5/8"
METAL
STUD
NEW 5/8"
GYP BD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W37
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. EXTEND STUDS TO 6"
ABOVE FINISH CEILING HEIGHT. GC
INSTALL 1 LAYER OF 1/2" TILE BACKER
BOARD ON BOTH SIDES OF WALL. GC
INSTALL WALL TILE FROM FLOOR TO
CEILING PER FINISH SCHEDULE.3 5/8" 3 5/8"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W38
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR 6" ABOVE
FINISH CEILING HEIGHT - BRACE BACK
TO STRUCTURE AT MIN. 4'-0" O.C. GC
INSTALL 1 LAYER OF 5/8" GYPSUM
BOARD ON BOTH SIDES OF WALL -
CONTINUE GYPSUM BOARD FINISH UP
TO 6" ABOVE CEILING HEIGHT. GC
FINISH AND PAINT GYPSUM BOARD
PER FINISH SCHEDULE. GC INSTALL
STAINLESS STEEL PANEL FROM
FLOOR TO CEILING IN EXHAUST HOOD
AREA. SEE FINISH SCHEDULE.3 5/8" 5/8"5/8" NEW 5/8"
GYP BD
3 5/8"
METAL
STUD
NEW
STAINLESS
STEEL
PANEL
EXISTING EXTERIOR CMU WALL WITH
EXISTING 3 5/8" METAL STUD FURRING
IN PLACE TO REMAIN. GC INSTALL
NEW 1/2" TILE BACKER BOARD FROM
FLOOR TO 6" ABOVE FINISH CEILING
HEIGHT. GC INSTALL WALL TILE PER
FINISH SCHEDULE.
EXISTING EXTERIOR WALL
W39
3 5/8" EXIST 3 5/8"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
EXISTING EXTERIOR CMU WALL. GC
INSTALL NEW 3 5/8" METAL STUD
FURRING TO 6" ABOVE FINISH CEILING
HEIGHT. GC INSTALL NEW 1/2" TILE
BACKER BOARD FROM FLOOR TO 6"
ABOVE FINISH CEILING HEIGHT. GC
INSTALL WALL TILE PER FINISH
SCHEDULE.
EXISTING EXTERIOR WALL
W40
3 5/8" EXIST 3 5/8"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
W41
GC INSTALL NEW 3 5/8" METAL STUDS
AT 16" O.C. FROM FLOOR TO 6" ABOVE
FINISH CEILING HEIGHT. GC INSTALL 1
LAYER OF 1/2" TILE BACKER BOARD
ON ROOM FINISH SIDE OF WALL (NOT
COOLER SIDE) - CONTINUE BACKER
BOARD TO 6" ABOVE FINISH CEILING
HEIGHT. GC INSTALL TILE FROM
FLOOR TO CEILING PER FINISH
SCHEDULE.
2 1/2"
METAL
STUD
NEW TILE PER
FINISH
SCHEDULE
NEW TILE
BACKER BOARD
05/06/21