HomeMy WebLinkAbout22_A112A112
SECOND FLOOR
REFLECTED CEILING
PLAN AND DETAILS
SECOND FLOOR REFLECTED
CEILING PLAN
SCALE: 3/32" = 1'-0"1N
PROJECT NUMBER: 2020-007
CERTIFICATION:SITE ARCHITECTUREarchitecture + landscape architectureARCHITECT:
SITE ARCHITECTURE
architecture + landscape architecture
BRAD SMITH, RA | LEED AP
13144 EAST 186TH STREET
NOBLESVILLE, IN. 46060
PH: 317.374.8720
E-MAIL: brad@site-architecture.com
PROJECT CONTACT:
These drawings are intended for construction.
12.23.2020DATE ISSUED:
REVISIONS ISSUED:
CONSTRUCTION ISSUE SET
CARMEL, IN 46033NEEDLER'S FRESH MARKET4755 EAST 126TH STREETTENANT FINISH IMPROVEMENTSTHE ENGINEERING
COLLABORATIVE
SAM HURT, P.E.
2410 EXECUTIVE DRIVE, SUITE 100
INDIANAPOLIS, IN. 46241
PH: 317.636.3941
E-MAIL: sam@tec-mep.com
PROJECT CONTACT:
MEP ENGINEER:
EXIST
8'-0"
ACT-01
E-028'-0"
ACT-01
PRICING
COORDINATOR
202
NETWORK/
TELCO
203
CORRIDOR
201
STAIR A
STA-2
MECH/
UTILITY
205
CEILING DETAIL
SCALE: 3" = 1'-0" 2
AIRCRAFT CABLE ATTACHED TO
STRUCTURE / UNISTRUT ABOVE
2X WOOD BLOCKING
PROFILE TO BE FABRICATED
BY MILLWORK CONTRACTOR
WITH LAM-01 FINISH
CEILING DETAIL
SCALE: 3" = 1'-0" 3
AIRCRAFT CABLE ATTACHED TO
STRUCTURE / UNISTRUT ABOVE
2X WOOD BLOCKING
ACT-02 SUSPENDED CEILINGWP-02 WALL COVERING 8"6" 6"8"+10'-0"
B.O. WOOD RING
+10'-0"
B.O. WOOD RING
A. PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE.
ARCHITECT IS TO APPROVE ALL ACCESS PANEL LOCATIONS
PRIOR TO INSTALLATION.
B. PROVIDE GYPSUM VERTICAL SURFACES FOR ALL BULKHEAD
CONDITIONS. VERIFY TRANSITIONS BETWEEN DIFFERENT
MATERIALS OR FROM FINISH CEILING AREAS TO EXPOSED
CEILINGS WITH ARCHITECT PRIOR TO INSTALLATION.
C. REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
D. THE ARCHITECTURAL CEILING PLANS SHALL GOVERN THE
LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS.
COORDINATE WITH THE ARCHITECT ANY FIELD VERIFIED OR
AS BUILT CONDITIONS THAT DIFFER FROM WHAT IS SHOWN
ON THE DRAWINGS.
E. SEE MEP DRAWINGS FOR LIGHT FIXTURE AND DIFFUSER
LOCATIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES.
F. PROVIDE PHYSICAL SAMPLES AND SHOP DRAWINGS FOR ALL
NEW INTERIOR FINISH MATERIALS TO ARCHITECT FOR
REVIEW/APPROVAL PRIOR TO ORDERING/FABRICATION AND
INSTALLATION
G. LIGHT FIXTURES SHOWN ARE FOR REFERENCE ONLY.
CEILING LEGEND:
CEILING MATERIAL A
CEILING HEIGHT 9'-0"
RCP NOTES:
C1. BULKHEAD FROM HEIGHT NOTED TO DECK / STRUCTURE ABOVE.
FINISH BOTTOM EXPOSED FACES, AND SIDES WITH 5/8" GYPSUM
BOARD WITH LEVEL 5 FINISH. WP-01 TO BE APPLIED TO FRONT
AND BOTTOM OF BULKHEAD UP TO 14'-6" A.F.F. PAINT BULKHEAD
PT-02 BETWEEN 14'-6" A.F.F. AND BOTTOM OF DECK / STRUCTURE.
CX
CEILING TYPES:
2X2 CEILING GRID - NO TILE
GYPSUM BOARD CEILING/BULKHEAD
E-01 EXISTING OPEN STEEL STRUCTURE. PAINT PER FINISH
SCHEDULE (1 PRIME COAT, 2 FINISH COATS).
RCP GENERAL NOTES:
GYP-01 5/8" GYPSUM BOARD FINISH CEILING/BULKHEAD. FINISH AND
PAINT (1 PRIME COAT, 2 FINISH COATS) - SEE FINISH TAG AND
REF FINISH SCHEDULE.
2X2 ACOUSTICAL GRID AND CEILING TILE
EXISTING EXPOSED STRUCTURE / DECK
COOLER CEILING PANELS
C4. DECORATIVE OPEN WOOD FRAME SUSPENDED FROM ROOF
STRUCTURE WITH AIRCRAFT CABLE ANCHORED TO UNISTRUT
AND STRUCTURE ABOVE. SEE SECTION DETAIL 2/A112.
ACT-01 24" X 48" LAY IN VINYL FACED CEILING TILE AND GRID
BASIS OF DESIGN:
MANUFACTURER: ARMSTRONG
PRODUCT: KITCHEN ZONE 673, COLOR - WHITE
GRID: PRELUDE 15/16"
ACT-02 24" X 24" LAY IN DECORATIVE CEILING TILE AND GRID
BASIS OF DESIGN:
MANUFACTURER: ARMSTRONG
PRODUCT: METALWORKS TIN EXTRA MICROPERFORATED
COLOR - TIN WHITE
GRID: SUPRAFINE XL 9/16"
E-02 EXISTING OPEN STEEL STRUCTURE. CLEAN AS REQUIRED,
TO REMAIN UNFINISHED.
E-03 EXISTING COOLER PANELS. CLEAN AS REQUIRED AND
REPAIR ANY DAMAGED AREAS.
C2. BULKHEAD FROM HEIGHT NOTED TO DECK / STRUCTURE ABOVE.
FINISH BOTTOM EXPOSED FACES, AND SIDES WITH 5/8" GYPSUM
BOARD WITH LEVEL 5 FINISH. WP-02 TO BE APPLIED TO FRONT
AND BOTTOM OF BULKHEAD UP TO 14'-6" A.F.F. PAINT BULKHEAD
PT-02 BETWEEN 14'-6" A.F.F. AND BOTTOM OF DECK / STRUCTURE.
C3. BULKHEAD FROM HEIGHT NOTED TO DECK / STRUCTURE ABOVE.
FINISH BOTTOM EXPOSED FACES, AND SIDES WITH 5/8" GYPSUM
BOARD WITH LEVEL 5 FINISH. SEE INTERIOR ELEVATIONS FOR
FINISHES THIS AREA.
C5. OPEN STRUCTURE, CONDUITS, DUCTWORK, ETC., TO BE
PAINTED PT-02.
C6. A 1X2 WOOD TRIM PIECE TO BE ATTACHED AT 14'-6" A.F.F. AROUND
ENTIRE PERIMETER OF GENERAL SHELVING AREA 112. 1X2 TO BE
PAINTED PT-02. DRYWALL WALL AREA ABOVE 1X2 TRIM TO BE
PAINTED PT-02 TO DECK ABOVE.
C7. DECORATIVE OPEN FRAME SUSPENDED FROM ROOF STRUCTURE
WITH AIRCRAFT CABLE ANCHORED TO UNISTRUT AND
STRUCTURE ABOVE. CEILING PANELS TERMINATE TO FRAME
ON INTERIOR SIDE OF FRAME. SEE SECTION DETAIL 3/A112.
#5 - 2.25.2021
OFFICE
204
8'-0"
ACT-01
7
PROFILE TO BE FABRICATED
BY MILLWORK CONTRACTOR
WITH LAM-01 FINISH
6
#6 - 3.5.2021
#7 - 3.30.2021
05/06/21