HomeMy WebLinkAbout53_P201FUTURE TENANT 100 GROCERY 200 28,444 S.F. 5,191 S.F. RTU-1 RTU-1 RTU-1 RTU-1 RTU-1 RTU-1 RTU-1 RTU-1 Existing gas pressure regulator. Replace exist. 1 1 4"G with new 1 1 2"G 3 4"G 3 4"G 1"G 1"G 3 4"G 3 4"G down to existing meter set. Exist. 3 4"G Exist. 1 1 2"G Exist. 1 1 2"G Exist. 3 4"G Exist. 3 4"G Exist. 3 4"G Exist. 3 4"G Exist. 1 1 4"G Exist. 1"G Exist. 1"G Exist. 3 4"G Exist. 1"G Exist. 3 4"G Exist. 3 4"G 1"G Remove existing 1"G piping, repair roof. Remove existing 3 4"G piping, repair roof. Replace exist. 3 4"G with new 1 1 2"G 1 1 4"G down 1"G down 5 A. All fittings, piping, fixtures, materials, etc. to meet the current Safe Drinking Water Act with all of its amendments and the Reduction of Lead in Drinking water Act. B. All work shall comply with all national, state, local codes and ordinances pertaining to the work in this project. C. All plumbing fixtures shall be supplied with individual water supply stops and code approved traps. Exposed piping shall be chrome plated. D. All plumbing fixtures shall be installed with approved backflow prevention devices. E. No piping shall pass directly over electrical power distribution cabinets, panelboards, etc. Contractor to coordinate panel locations prior to piping installation. F. All plumbing vents to be a minimum of 10'-0" from any air intake. Coordinate locations with HVAC plans. G. Single runouts to plumbing fixtures shall be the same size as on the plumbing fixture schedule unless otherwise noted. H. Concealed gas piping shall be constructed in accordance with code without unions, tubing fittings or running threads. I. Gas lines run on roof to be supported by Roof Top Blox or similar and equal. DO NOT USE LUMBER FOR GAS PIPING SUPPORT. J. All waste, water, vent, gas and condensate lines shown to be connected to their associated fixture/equipment, unless noted otherwise. All equipment and systems shown must be complete and usable upon completion of project. )GPGTCN0QVGU P201 ROOF PLUMBING PLAN ROOF PLUMBING PLAN 1 SCALE: 3/32" = 1'-0" N P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R Exp. 7.31.2022 PROJECT NUMBER: 2020-007 CERTIFICATION: SITE ARCHITECTURE architecture + landscape architecture ARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. DATE ISSUED: 12.23.2020 REVISIONS ISSUED: CARMEL, IN 46033 NEEDLER'S FRESH MARKET 4755 EAST 126TH STREET TENANT FINISH IMPROVEMENTS THE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: CONSTRUCTION ISSUE SET #6 - 3.5.2021 05/06/21