Loading...
HomeMy WebLinkAbout63_E20321 22 23 25 26 29 34 Existing +48" Panel "C1" Existing Panel "C2" Relocate Existing Panel "C3" +48" +48" +48" (1) (1) (1) (1) (1) 5 (2) (2) +48" (1) (2) +48" +48" (4) (4) +48" (1) (1) (2) (2) (2) (2) (1) (2) +48" +48" +48" +48" (4) (4) (4) (4) IG IG IG IG IG IG (1) +48" +48" G-3 G-5 G-7 G-9 G-8 G-14 G-8,10,12,14 G-3,5,7,9 4 (4)120V., 20 amp G-20 G-22 IG IG IG IG IG 4 120V., 20 amp 120V., 4 20 amp 4 120V., 20 amp J 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 208V.,3Ø 20 amp 4 12 +48" +48" 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 9 (2) For EMS 4 120V., 20 amp WP on roof 208V.,3Ø 40 amp 4 Note: For remote Rack B condensor unit, coordinate exact location w/owner prior 208V.,3Ø 30 amp, #10 wire 4 4 120V., 20 amp Mount just below countertop, coordinate with millwork vendor prior to rough-in (typ. 3) 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp VESTIBULE A 101 PRODUCE 102 FLORAL 103 CHECK OUT 104 BEER/ WINE 115 MEAT 117 COMPRESSOR RACK B 156 MEAT COUNTER 142 MEAT FREEZER 143 MEAT COOLER 144 MEAT PREP 145 PRODUCE DISPLAY 146 CHOP SHOP 147 CORR 148 JANITOR 151 PRODUCE PREP 150 CORR 155 PRODUCE COOLER 154 BREAK ROOM 153 MGR/LOSS PREV. OFFICE 152 +48" +36" 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp +48" +48" 4 120V., 20 amp +48" +48" 120V., 20 amp 4 WS-1 +48" 4 120V., 20 amp 7 Plan Notes: Reuse existing gondola circuits in this area. Circuit to existing Panel "F2". Utilize existing 120 volt, 20 amp circuit breakers abandoned from demolition. Provide and install new circuit breakers as required. Circuit to existing Panel "F". Utilize existing 120 volt, 20 amp circuit breakers abandoned from demolition. Provide and install new circuit breakers as required. Connect to new equipment location as required. Reuse existing circuit(s) where applicable or new circuit to available space in existing 120/208 volt panel. Ceiling mounted for access point. Provide and install a 3' plugstrip with single-plex 6" o.c. above countertop. Cut, patch and repair floor in-kind for circuit routing underslab. Verify equipment electrical connection with owner prior to rough-in. Connect to new equipment location as required. Reuse existing circuit(s) where applicable or new circuit to available space in existing 120/208 volt panel. 120 volt, 20 amp circuit breaker. Provide shunt-trip circuit breaker. Provide GFCI circuit breaker. 1 2 4 5 10 11 General Notes: All 120 volt, 20 amp circuits over 60' in length shall be #10 AWG, over 95' shall be #8, over 145' shall be #6. Contractor shall coordinate with all other trades to avoid conflicts of space. Contractor shall coordinate the exact location of all devices with all other trades prior to rough-in. Exact location to be determined in the field. Contractor shall coordinate with the mechanical and plumbing contractors for exact locations of equipment prior to rough-in. Refer to sheet E701 for details and symbols. Refer to sheet E601 for light fixture schedule. Refer to sheet E901 for electrical specifications. Shared neutrals shall not be permitted. Note "H" clips are not acceptable for junction box supporting. Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted. Receptacles, telephone outlets, and television outlets shall be a minimum of +18" A.F.F. to the bottom of the device unless otherwise noted. Where devices are installed in fire walls, the boxes shall be rated and sealed for installation in a fire wall. Provide HACR circuit breakers for all HVAC and refrigeration equipment. No conduit to be supported from the roof deck. Coordinate all floor cut means and methods of routing conduit through floor prior. A. B. C. D. E. F. G. H. J. K. L. M. N. P. Q. 3 6 12 9 14 P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R Exp. 7.31.2022 PROJECT NUMBER: 2020-007 CERTIFICATION: SITE ARCHITECTURE architecture + landscape architecture ARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. DATE ISSUED: 12.23.2020 REVISIONS ISSUED: CARMEL, IN 46033 NEEDLER'S FRESH MARKET 4755 EAST 126TH STREET TENANT FINISH IMPROVEMENTS THE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: CONSTRUCTION ISSUE SET #7 - 3.30.2021 FIRST FLOOR POWER - AREA 1 ENLARGED PLAN 1 SCALE: 3/16" = 1'-0" N E203 FIRST FLOOR POWER - AREA 1 ENLARGED PLAN MATCH LINE MATCH LINE MATCH LINE MATCH LINE AREA 1 AREA 2 AREA 1 AREA 2 AREA 4 AREA 1 N KEY PLAN SCALE: 1/64" = 1'-0" 05/06/21