HomeMy WebLinkAbout66_E206Existing Panel "D" Existing Panel "D2" EVAP +48" 120V., 20 amp 4 120V., 20 amp 4 208V.,3Ø 25 amp #10 wire 4 +85" +85" 208V.,3Ø 50 amp #8 wire 4 208V.,3Ø 60 amp #6 wire 4 (2) (1) (1) +48" +48" 208V.,3Ø 50 amp #8 wire 4 +48" +48" +48" +48" +48" (1) (1) (1) (1) +48" +48" +48" +48" 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 12 12 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 120V., 20 amp 4 208V.,3Ø 40 amp #8 wire 4 12 J 120V., 20 amp 4 At drop ceiling for signage, signage by others BAKERY DELI 119 118 BAKERY PREP 131 WASH 132 DELI PREP 133 134 DELI COOLER 135 CORR 136 MEN RR 137 WOMEN RR 138 CORR 139 SEAFOOD PREP 140 SEAFOOD COOLER 141 MEAT FREEZER 143 STAIR A STA-1 CHEESE ISLAND 116 DELI STOR +48" 120V., 20 amp 4 +48" 120V., 20 amp 4 +48" 120V., 20 amp 4 +48" 120V., 20 amp 4 +48" +48" 15 J 15 J 16 16 120V., 20 amp (Hood controls) 4 208V.,3Ø 15 amp (MAU) 208V.,3Ø 15 amp (Ex. fan) 208V.,3Ø 15 amp (Ex. fan) 208V.,3Ø 50 amp #8 wire 4 12 208V.,3Ø 50 amp #8 wire 4 12 120V., 20 amp (Hood controls) 4 120V., 20 amp (Ex. fan) 4 120V., 25 amp, #10 wire (MAU) 4 4 4 4 208V.,3Ø 15 amp 4 4 2NCP0QVGU Reuse existing gondola circuits in this area. Circuit to existing Panel "F2". Utilize existing 120 volt, 20 amp circuit breakers abandoned from demolition. Provide and install new circuit breakers as required. Circuit to existing Panel "F". Utilize existing 120 volt, 20 amp circuit breakers abandoned from demolition. Provide and install new circuit breakers as required. Connect to new equipment location as required. Reuse existing circuit(s) where applicable or new circuit to available space in existing 120/208 volt panel. Ceiling mounted for access point. Provide and install a 3' plugstrip with single-plex 6" o.c. above countertop. Cut, patch and repair floor in-kind for circuit routing underslab. Verify equipment electrical connection with owner prior to rough-in. Connect to new equipment location as required. Reuse existing circuit(s) where applicable or new circuit to available space in existing 120/208 volt panel. 120 volt, 20 amp circuit breaker. Provide shunt-trip circuit breaker. Provide GFCI circuit breaker. Provide hexagon junction box with 1" conduit to above accessible ceiling for hood emergency pull station. Refer to hood drawings for detailed wiring requirements and include all associated work not included by hood MFR. 1 2 4 5 10 11 )GPGTCN0QVGU All 120 volt, 20 amp circuits over 60' in length shall be #10 AWG, over 95' shall be #8, over 145' shall be #6. Contractor shall coordinate with all other trades to avoid conflicts of space. Contractor shall coordinate the exact location of all devices with all other trades prior to rough-in. Exact location to be determined in the field. Contractor shall coordinate with the mechanical and plumbing contractors for exact locations of equipment prior to rough-in. Refer to sheet E701 for details and symbols. Refer to sheet E601 for light fixture schedule. Refer to sheet E901 for electrical specifications. Shared neutrals shall not be permitted. Note "H" clips are not acceptable for junction box supporting. Switches shall be a maximum +48" A.F.F. to the top of the device unless otherwise noted. Receptacles, telephone outlets, and television outlets shall be a minimum of +18" A.F.F. to the bottom of the device unless otherwise noted. Where devices are installed in fire walls, the boxes shall be rated and sealed for installation in a fire wall. Provide HACR circuit breakers for all HVAC and refrigeration equipment. No conduit to be supported from the roof deck. Coordinate all floor cut means and methods of routing conduit through floor prior. A. B. C. D. E. F. G. H. J. K. L. M. N. P. Q. 3 6 12 9 14 15 16 4 P R O F E S S I O N A L E N G N I E E R S A M U E L L. H U R T I N D I A N A 0 N P E 1 6 o . 10 0 87 S T A T E O F R E T E G I S D E R Exp. 7.31.2022 PROJECT NUMBER: 2020-007 CERTIFICATION: SITE ARCHITECTURE architecture + landscape architecture ARCHITECT: SITE ARCHITECTURE architecture + landscape architecture BRAD SMITH, RA | LEED AP 13144 EAST 186TH STREET NOBLESVILLE, IN. 46060 PH: 317.374.8720 E-MAIL: brad@site-architecture.com PROJECT CONTACT: These drawings are intended for construction. DATE ISSUED: 12.23.2020 REVISIONS ISSUED: CARMEL, IN 46033 NEEDLER'S FRESH MARKET 4755 EAST 126TH STREET TENANT FINISH IMPROVEMENTS THE ENGINEERING COLLABORATIVE SAM HURT, P.E. 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN. 46241 PH: 317.636.3941 E-MAIL: sam@tec-mep.com PROJECT CONTACT: MEP ENGINEER: CONSTRUCTION ISSUE SET #4 - 2.17.2021 FIRST FLOOR POWER - AREA 4 ENLARGED PLAN 1 SCALE: 3/16" = 1'-0" N E206 FIRST FLOOR POWER - AREA 4 ENLARGED PLAN N KEY PLAN SCALE: 1/64" = 1'-0" MATCH LINE MATCH LINE MATCH LINE MATCH LINE AREA 4 AREA 1 AREA 4 AREA 1 AREA 4 AREA 3 AREA 4 AREA 3 05/06/21