Loading...
HomeMy WebLinkAboutA6-1FIRST FLOOR 0" ROOF BEARING 10'-4" BASEMENT -10'-4" TPO MEMBRANE ROOFING FIBER MESH WEEP VENTS @ 24" O.C. MAX BRICK, TO MATCH EXISTING MASONRY'S SHAPE, TEXTURE, AND PATTERN, PAINTED STUD PACK COLUMN POWDER-COATED ALUMINUM SUN-SCREEN SYSTEM, REF. DETAILS A3-1 6 8 3/16" 8 7/16" EXISTING EXTERIOR STUD WALL, NEW INSULATION COLUMN BASE AND FOUNDATION PER STRUCTURAL 10'-7" METAL, WOOD LOOK, SLAT WALL SYSTEM, 6" V-GROOVE PANEL VAPOR RETARDER LVL'S - SEE STRUCTURAL A6-4 1 SIM TPO MEMBRANE ROOFING TAPERED INSULATION w/ 3/8" COVERBOARD 10" TJI 1" FLAT PAN 24 GA STEEL SOFFIT PANEL - CHAMPAGNE 3/4" EXTERIOR GRADE SHEATHING FIRST FLOOR 0" ROOF BEARING 10'-4" BASEMENT -10'-4" 8'-8" A6-4 1 A6-4 5 POWDER-COATED ALUMINUM SUN-SCREEN SYSTEM, REF. DETAILS TPO MEMBRANE ROOFING TAPERED INSULATION w/ 3/8" COVERBOARD METAL, WOOD LOOK, SLAT WALL SYSTEM, 6" V-GROOVE PANEL 1" FLAT PAN 24 GA STEEL SOFFIT PANEL - CHAMPAGNE 1" FLAT PAN 24 GA STEEL SOFFIT PANEL - CHAMPAGNE 3'-11 11/16" 3/4" EXTERIOR GRADE SHEATHING VAPOR RETARDER ALUMINUM FRAMED STOREFRONT AS SCHEDULED LVL'S - SEE STRUCTURAL LVL'S - SEE STRUCTURAL WDC-1 8'-0" A.F.F. 8" METAL CORNER CAP TO MATCH MULLION INTERIOR STOREFRONT MULLION 1" FLAT PAN 24 GA STEEL SOFFIT PANEL - CHARCOAL GRAY 10'-7" A3-1 6 10" TJI FIRST FLOOR 0" ROOF BEARING 10'-4" BASEMENT -10'-4" 1/2" MOISTURE RESISTANT DRYWALL, MUDDED AND TAPED INSERT BAFFLES BETWEEN TRUSSES TO LEVEL ABOVE EXISTING INSULATION ROOF UNDERLAYMENT PRE-FINISHED, METAL STANDING SEAM ROOFING SYSTEM PRE-FINISHED, CONT. ALUMINUM STRIP VENT - 3" WIDE RE-USE EXISTING WOOD TRIM, REPLACE AND REPLICATE IF DAMAGED. PATCH, REPAIR AND RE-FINISH ANY EXISTING TRIM CLEAN MASONRY, REPOINT MORTAR JOINTS AS NEEDED, INSPECT WEEPS AND REPAIR AND REPLACE FIBER MESH AS NEEDED - PAINT EXISTING MASONRY EXISTING FOUNDATION WALL EXISTING INSULATION TO REMAIN. BLOW IN BELOW BAFFLES IF GAPS CREATED ACT-1 8'-0" A.F.F. RF-4 ROOF OVERBUILD A3-1 3 10'-7" FIRST FLOOR 0" ROOF BEARING 10'-4" BASEMENT -10'-4" ACT-3 8'-5" A.F.F. 1/2" MOISTURE RESISTANT DRYWALL, MUDDED AND TAPED INSERT BAFFLES BETWEEN TRUSSES TO LEVEL ABOVE EXISTING INSULATION ROOF UNDERLAYMENT RE-USE EXISTING WOOD TRIM, REPLACE AND REPLICATE IF DAMAGED. PATCH, REPAIR AND RE-FINISH ANY EXISTING TRIM EXISTING INSULATION TO REMAIN. BLOW IN BELOW BAFFLES IF GAPS CREATED ROOF EDGE TRIM, VENTS, TO REMAIN - CLEAN / REPAIR AS NECESSARY, NEW PAINT CLEAN MASONRY, REPOINT MORTAR JOINTS AS NEEDED, INSPECT WEEPS AND REPAIR AND REPLACE FIBER MESH AS NEEDED - PAINT EXISTING MASONRY EXISTING FOUNDATION WALL ACT-2 8'-0" A.F.F. tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME A6-1 WALL SECTIONS & DETAILS Author 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 SCALE: 3/4" = 1'-0" 1 WALL SECTION - A SCALE: 3/4" = 1'-0" 2 WALL SECTION - B SCALE: 3/4" = 1'-0" 3 WALL SECTION - C SCALE: 3/4" = 1'-0" 4 WALL SECTION - C1 05/07/21