Loading...
HomeMy WebLinkAboutE0-1J S FACP SYMBOL I T E M FIRE SPRINKLER TAMPER SWITCH FAN SPEED CONTROL CIRCUITING BACK TO THE PANEL BOX LOCATION OF ELECTRICAL PANEL SEE THIS SHEET FOR TYPE AND VOLTAGE FAN MOTOR FIRE ALARM CONTROL PANEL JUNCTION BOX HARDWIRE ELECTRICAL CONNECTION SPECIALTY APPLIANCE RECEPTACLES GROUND FAULT DUPLEX RECEPTACLE + 44" ABOVE FINISHED FLOOR 30AMP +44" GFI 4 PLEX RECEPTACLES DUPLEX RECEPTACLE IN FLOOR BOX DEVICE BOX FOR TELEPHONE JACK LOCATION W/ METAL CONDUIT GOING ABOVE THE CEILING DUPLEX RECEPTACLE CABLE TV CONNECTION METER LOCATION NON FUSED DISCONNECT SWITCH 3R DENOTES NEMA CONSTRUCTION TYPE 40AMP 1 RJ45 DATA JACK & 1 TELEPHONE JACK IN FLOOR BOX ME 4-PLUG RECEPTACLE W/ ISOLATED GROUND FOR COMPUTERS FUSED DISCONNECT SWITCH 60 AMP IS RATING / 50 INDICATES FUSE SIZE 3R DENOTES NEMA CONSTRUCTION TYPE DEVICE BOX FOR DATA JACK LOCATIONS W/ METAL CONDUIT GOING ABOVE THE CEILING OR FLOOR WITH CAT 6 CABLES # INDICATES # OF DATA JACKS & CABLEING E L E C T R I C A L L E G E N D CA TPR DUPLEX RECEPTACLE 1 RJ45 DATA JACK & 1 TELEPHONE JACK ONE SINGLE FLOOR BOX RECESSED CAN LIGHT FIXTURE EXIT SURFACE MOUNTED LIGHT FIXTURE EMERGENCY LIGHTS WITH BATTERY BACK-UP UNIVERSAL EXIT LIGHTS W/ BATTERY BACK-UP AND EMERGENCY LIGHTS 2 X 4 GRID CEILING EXHAUST FAN RECESSED MOUNTED FLOURESCENT FIXTURE T WP WEATHERPROOF DUPLEX RECP. EP SURFACE MOUNTED LIGHT FIXTURE S ON OFF WALL SWITCH SC BB BASEBOARD HEATER SYMBOL I T E M EXIT EXIT SIGN W/ BATTERY BACK-UP DIRECTIONAL ARROW HC HANDICAP DOOR OPERATOR REMOTE ODM OVERHEAD DOOR MOTOR V VOLUME CONTROL COND AC CONDENSER TELEPHONE DMARK LOCATION FIBER OPTIC LOCATION DMARK FIBER ANTENNA FOR RIALTOS LIGHTING CONTROL ANTNN SYSTEM WP WALL POD NLIGHT, N POD GFX GRAPHIC LIGHT CONTROLLER FAN EH ELECTRIC CEILING OR WALL HEATER TRANSFORMER S OCCUPANCY SENSOR CEILING MOTION & SOUND D WALL SWITCH WITH DIMMER OCC OCCUPANCY SENSOR WALL MOTION & SOUND ODS OCCUPANCY DAYLIGHTING SENSOR NLIGHT PHOTOCELL HUBBLE #LUXSTATLS PP POWER PACK LV LOW VOLTAGE MANUAL ON SWITCH OCW LV D LOW VOLTAGE MANUAL ON SWITCH WITH DIMMER LEVITON #LVS-1x AUTOMATIC OFF OCC SENSOR LEVITON # 0PP20-D2 LEVITON # 0SC20-MOW LEVITON # 0SSMT-GDx LEVITON # IP710-LFZ PS PHOTO CELL HUBBLE #LUXSTATLSO 2 AD ALARM DEVICE T TIMER S F ON OFF SWITCH FOR 120 V POWER TO FROSTED WIN. SCP SECURITY CONTROL PANEL AREA SITE LIGHTING FIXTURE AREA SITE LIGHTING FIXTURE GENERAL ELECTRICAL NOTES 1. SEE THE DIVISION 16 SPECIFICATION BOOK WHICH HAS BEEN INCLUDED WITH THIS PLAN SET, 2. E.C. TO INCLUDE 10 ADDITIONAL 120V/1P 20A CIRCUITS FOR ADDED EQUIPMENT AND PLAN REVISIONS, LENGTH NOT TO EXCEED 100' FROM PANEL AND INCLUDE A SEPARATE CONDUIT SYSTEM FOR EACH CIRCUIT, A 20A DISCONNECT FOR EACH CIRCUIT. 3. E.C. TO INCLUDE 6 DATA JACKS & CABLEING BACK TO IT ROOM. 4. E.C. TO ACCEPT, UNLOAD, AND ASSEMBLE LIGHT FIXTURES AS REQUIRED. FIXTURES MAY NOT HAVE THE REQUIRED VOLTAGE PRE-WIRED, WHIPS MAY NOT BE INCLUDED. E.C. SHALL SIGN FREIGHT SLIPS WITH "CONCEALED DAMAGE" TO EASE THE PROCESS FOR FREIGHT CLAIMS. 5. E.C. SHALL PROVIDE A ONE YEAR LABOR WARRANTY FOR ALL EQUIPMENT INSTALLED, INCLUDING BUT NOT LIMITED TO OWNER AND CONTRACTOR PROVIDED EQUIPMENT. 6. ALL CONDUITS INSTALLED UNDER GROUND SHALL BE PVC SCHEDULE 80. PROVIDE GRMC ELBOWS AT FLOOR PENETRATIONS. 7. BRANCH CIRCUITS RUN CONCEALED IN WALLS OR ABOVE CEILINGS SHALL BE RUN IN EMT. 8. ALL BRANCH CIRCUITS SHALL INCLUDE A GROUNDING CONDUCTOR. 9. CONDUCTORS SHALL BE COPPER WITH THE TYPE "THHN-THWN" INSULATION RATED AT 600 VOLTS, CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID. 10. COLOR CODING FOR 120/208, 3ø , 4W SYSTEMS SHALL BE: PHASE A-BLACK, PHASE B-RED, PHASE C-BLUE, NEUTRAL-WHITE. 11. COLOR CODING FOR 277/480, 3ø , 4W SYSTEMS SHALL BE: PHASE A-BROWN, PHASE B-ORANGE, PHASE C-YELLOW, NEUTRAL-GREY. (IF APPLICABLE) 12. E.C SHALL PROVIDE APPROPRIATE FIRE STOPPING AT ALL PENETRATIONS OF RATED FLOORS, WALLS, AND CEILINGS TO MEET U.L. LISTING OF INSTALLED ASSEMBLIES. DETAILS HAVE BEEN PROVIDED FOR TYPICAL RATED ASSEMBLIES BUT ELECTRICAL CONTRACTOR SHALL COORDINATE W/ARCHITECTURAL PLANS FOR FINAL RATINGS AND PROVIDE APPROPRAITE FIRE RATING MATERIALS. SEE ARCH DWG FOR RATED WALL AND CEILING LOCATIONS. 13. MINIMUM SIZE LINE VOLTAGE CONDUCTORS SHALL BE #12. MINIMUM SIZE LOW VOLTAGE WIRING SHALL BE #14 AWG. 14. ALL ELECTRICAL INSTALLATIONS SHALL BE IN COMPLIANCE WIT NFPA 70 NEC 2011, AND APPLICABLE LOCAL ELECTRICAL CODES. 15. PROVIDE WATERPROOF SEALS IN ALL CONDUITS THAT ENTER OR LEAVE UNDERGROUND CONDUIT SYSTEMS. 16. E.C. IS RESPONSIBLE FOR PROVIDING ALL PENETRATIONS THRU CONSTRUCTION ELEMENTS. 17. PROVIDE EXPANSION FITTING AT ALL EXPANSION JOINTS. 18. MINIMUM SIZE HOMERUN CONDUIT SIZE FOR BRANCH CIRCUITS SHALL BE 3/4" U.O.N. 19. MINIMUM SIZE CONDUIT FOR TELEPHONE CONDUITS SHALL BE 1". 20. MINIMUM SIZE CONDUIT FOR F.A. SYSTEM SHALL BE 1/2". 21. LABEL ALL JUNCTION BOXES WITH DESCRIPTION OF CIRCUITS CONTAINED. 22. ALL F.A. JUNCTION BOXES ARE TO BE PAINTED RED. 23. EMT CONDUIT CONNECTORS SHALL UTILIZE STEEL COMPRESSION FITTINGS. 24. ALL CONDUITS SHALL BE ROUTED PERPENDICULAR AND PARALLEL TO BUILDING STRUCTURE. 25. ALL TELEPHONE OUTLETS SHOWN ARE TO INCLUDE A TELEPHONE AND DATA PORT. 26. ON ALL ELECTRICAL DEVICES, REUSE EXTG. CIRCUITING AND WIRING IF POSSIBLE. ADD CIRCUITS IN THE EXTG. ELEC. PANELS AS NEEDED. EC RESPONSIBLE FOR ELEC. LOADS AND WIRING SIZING AND ROUTES OF CONDUIT OF WIRING FOR NEW OR EXTG.ELECTRICAL ITEMS. CONNECT NEW DEVICES INTO THE CLOSEST ELECTRICAL PANEL. USE THE NEW ELECTRICAL PANEL AS NEEDED FOR ANY NEW CIRCUITS. 27. NOT USED 28. NOT USED 29. ALL ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO SHOW THE APPROXIMATE LOCATION OF EQUIPMENT AND PIPING AND MUST NOT BE USED FOR OBTAINING LINEAL RUNS OF WIRING OR CONDUIT. 30. ALL DIMENSIONS GIVEN ON THE PLANS SHALL BE VERIFIED IN THE FIELD. DRAWINGS MAY NOT BE SCALED TO OBTAIN EXACT DIMENSIONS OR LOCATIONS. PROVIDE SHOPS DRAWINGS WITH DIMENSIONS TO THE PROJECT ENGINEER AND GENERAL CONTRACTOR FOR REVIEW. 31. E.C. TO REVIEW MECHANICAL AND PLUMBING DRAWINGS AND VERIFY ELECTRICAL CONNECTIONS REQUIRED FOR THE EQUIPMENT. 32. E.C. SHALL SUPPLY CIRCUIT AND DEVICE POWER TO THE EQUIPMENT LOCATED ON MECHANICAL AND PLUMBING DRAWINGS, INCLUDING A SERVICE DISCONNECT SWITCH FUSED AT THE REUQIRED MOTOR OR NAMEPLATE RATING. E.C. SHALL CONNECT ALL STARTERS, FURNISHED AND INSTALLED BY M.C.. 33. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE IN THEIR BASE BID THE INSTALLATION OF ALL CONTROL CONDUITS, WIRING, AND DEVICES, BOTH LINE AND LOW VOLTAGE, WHICH WILL REQUIRE THE SERVICES OF A LICENSED ELECTRICIAN QUALIFIED TO WORK IN THE JURISDICTION OF THISPROJECT AND APPROVED BY THE PROJECT MANAGER. 34. PER NEC 376.22 METAL WIREWAYS SHALL NOT CONTAIN MORE THAN 30 CURRENT CARRYING CONDUCTORS AT ANY CROSS SECTION. 35. PER NEC 408.4 E.C. SHALL LEGIBLY IDENTIFY EACH CIRCUIT ON THE PANEL SCHEDULES AND CIRCUIT DIRECTORY. INCLUDE ROOM NAME AND DEVICE, LIGHT, OR EQUIPMENT LIGHT FIXTURE IS CONNECTED TO. 36. PER NEC 230.95 SERVICE ENTRANCE MAIN SWITCH GROUND FAULT TESTNG IS REQUIRED AND SHALL BE THE RESPONSIBILITY OF THE E.C. 37. VERIFY ALL SWITCH, DEVICE, AND OUTLET COLORS WITH THE OWNER. CAM CAMERA LOCATION ACCESS CONTROL SYSTEM SYMBOL LEGEND CAM EX EXTERIOR CAMERA LOCATION CR ACCESS CONTROL CARD READER DC MAGNETIC DOOR CONTACT EL ELECTRIC LOCK / POWER SUPPLY BY OTHERS SEC SECURITY SYSTEM PANEL ACP ACCESS CONTROL PANEL NVR NETWORK VIDEO RECORDER POE POE NETWORK SWITCH K ACCESS CONTROL KEYPAD POWERED WITH CAT 6 CABLEING POWERED WITH CAT 6 CABLEING NVR - IP04-16T-R4A EXACQ VID SERV, 16TB, WIN10 EXACQ EVIP01 CAMERA LICENSE EXACQ RACK - 119-5028 4U WALL RACK RACKSOLUTIONS UPS - PS15-1100RT120 LIEBERT UPS 1100VA LIEBERT BATTERY BACK UP POE - 1920S HP POE SWITCH, 24 PORT, 2SFP HP CAMERA - XNV-6011 INTERIOR DOME CAM 2MP HANWAH CAMERA - XNO-8080R EXTERIOR BULLET CAM 5MP HANWAH VIDEO SYSTEM EQUIPMENT MS MOTION SENOR GB MOTION SENOR HUB HOLD UP BUTTON AKP ACCESS KEYPAD tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME E0-1 ELECTRICAL NOTES & LEGENDS DKM 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 D R A W I N G L I S T E0-1 - Electrical Notes & Legends E1-1 - Electrical Power Plan E1-2 - Electrical Basement Floor Plan E2-1 - Electrical Lighting Plan E4-1 - Electrical Riser & Details M1-1 - HVAC Plan M2-1 - Mechanical Details & Schedules M2-2 - Mechanical Details & Schedules P1-1 - Plumbing Plan P2-1 - Plumbing Details & Schedules 05/07/21