HomeMy WebLinkAboutE2-1ALL OCCUPANCY SENSOR TO BE SET TO TURN OFF LIGHTS LESS THAN 30 MINUTES AFTER ANYBODY LEAVES THE ROOM. 1 NL, NIGHT LIGHTS TO BE ON NON SWITCHING OPERATION ALL NIGHT LIGHTS NL, TO HAVE EMERGENCY BATTERY BACK UP 90 MINUTE. UL 924 DEVICE REQUIRED AT LED FIXTURES WHEN USED AS EM & ALSO USED AS DIMMABLE FIXTURES. 2 3 4 L I G H T I N G N O T E S NIGHT LIGHTS NLA, NLB, TO BE CONTROLLED THRU TIME CLOCK. 5 6 SEE ELECTRICAL LEGEND FOR OCCUPANCY SENSORS, POWER PACKS TYPES. EXACT LOCATION OF DRIVE LANE OPEN CLOSE SIGNS & CONTROLS BY OWNER. 7 NEW OCCUPANCY SENSOR THIS AREA. TIE INTO EXTG. LIGHTING CIRCUITS. ADD LIGHTING CIRCUITS AS NEEDED. 8 TIE NEW LIGHTING INTO EXTG. SWITCHING THIS ROOM. 9 REMOVE EXTG. SWITCHING FOR CANOPY. COORDINATE IF EXTG. CONDUIT CAN BE REUSED. REUSE EXTG. CIRCUITING AND WIRING IF POSSIBLE. ADD CIRCUITS IN THE EXTG. ELEC. PANELS AS NEEDED. EC RESPONSIBLE FOR ELEC. LOADS AND WIRING SIZING AND ROUTES OF CONDUIT OF WIRING FOR NEW OR EXTG. ELECTRICAL ITEMS. 10 11 JBL BRAND SPEAKER IN CEILING. PLAYLIST TO BE CONTROLLED BY IPAD. VOLUME BY CONTROL ON THE WALL. HARDWIRED TO VOLUME CONTROL. SOUND SYSTEM REQUIREMENTS 1, SONOS AMP. MFR # AMPG1US1BLK, Attach desired speakers Your speakers’ power rating should be at least 125W for 8 ohm speakers, and at least 200W for 4 ohm speakers. Do not connect speakers rated at less than 4 ohm. Note:Amp can drive speakers with nominal impedance above 4 ohms. Two pairs of 8 ohm speakers wired in parallel are also supported. Don’t wire your speakers in series because it will result in poor sound quality. Remove the cap from the banana plug to reveal the connection hole. Insert the stripped end of the speaker wire into the hole, then return the cap to the banana plug to secure the connection. 2, New-construction Bracket for Director 6.5" and 8" and Thinfit In-ceiling speakers 3, JBL Control® 26CT 6-1/2" commercial in-ceiling speaker 4, 3 Episode® Electronics 100 Watt Rotary Volume Control (Each | White & Light Almond) 5, 3 14/4 Audio wire up to 100' run 12 OCCUPANCY SENSOR OVERIDE WALL SWITCH. 13 SEE ELECTRICAL RISER DIAGRAM FOR CONTROL OF EXERIOR FIXTURES. THE EXTG. SITE LIGHTS TO BE CONTROLLED BY THE EXTG. TIMING DEVICE. LIGHT FIXTURE SCHEDULE GENERAL NOTES: A. ALL LIGHT FIXTURES SHALL BE UL LISTED. B. REFERENCE SPECIFICATION SECTION FOR ADDITIONAL REQUIREMENTS. C. ALL BIDDERS, INCLUDING THOSE SPECIFIED AND MANUFACTURERS LISTED AS “EQUAL”, SHALL SUBMIT PRODUCT CUTSHEETS TO THE ENGINEER TEN (10) DAYS PRIOR TO BID FOR FINAL WRITTEN APPROVAL. “EQUAL” FIXTURES SHALL BE OF EQUAL OR BETTER QUALITY AND PERFORMANCE TO THE SPECIFIED FIXTURE. BURDEN OF PROOF SHALL BE ON THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE WITH CORD AND PLUG AT THE REQUEST OF THE ENGINEER. D. MANUFACTURERS/VENDORS WISHING TO BID SUBSTITUTE FIXTURES OTHER THAN THOSE LISTED ON THE LIGHT FIXTURE SCHEDULE, SHALL SUBMIT CUTSHEETS AS REQUIRED PER SPECIFICATION SECTION 16500 AND AT THE REQUEST OF THE ENGINEER PROVIDE FACTORY POINT-BY-POINT CALCULATIONS USING AGI32 AND PROVIDE ELECTRONIC .AGI FILE TEN (10) DAYS PRIOR TO BID FOR WRITTEN APPROVAL. BURDEN OF PROOF SHALL BE ON THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE OF EACH SUBSTITUTE FIXTURE WITH CORD AND PLUG AT THE REQUEST OF THE ENGINEER. E. CONTRACTOR SHALL PROVIDE UNSWITCHED CONDUCTORS TO ALL FIXTURES WITH EMERGENCY LED BATTERY PACKS AS REQUIRED. F. CONTRACTOR SHALL FOCUS, AIM AND ADJUST LIGHT FIXTURES UNDER THE SUPERVISION AND DIRECTION OF THE ENGINEER AND ARCHITECT. ALLOW LABOR FOR FINAL FOCUS AND ADJUSTMENTS AFTER DARK. LIFTS AND SCAFFOLDING SHALL BE AVAILABLE. G. CONFIRM ALL FINISHES AND MOUNTING HEIGHTS WITH ARCHITECT DURING SHOP DRAWING REVIEW. PROVIDE CUSTOM, FACTORY CUT STEM LENGTHS AS REQUIRED. H. REFER TO DRAWINGS FOR MOUNTING REQUIREMENTS, NUMBER OF FACES AND ARROWS (CHEVRONS) FOR ALL EXIT SIGNS. COORDINATE WITH ARCHITECT’S REFLECTED CEILING PLANS. I. CONTRACTOR SHALL VERIFY CEILING TYPES PRIOR TO ORDERING FIXTURE AND PROVIDE FIXTURES APPROPRIATE TO THE ACTUAL CONDITION. THIS IS TO INCLUDE SPECIFIC TYPE OF LAY-IN CEILING GRID. J. ALL FIXTURES SHALL HAVE INTERNAL FAST-BLOW FUSING. K. ALL LAY-IN FIXTURES SHALL BE PROVIDED WITH SCREW ON HOLD DOWN CLIPS, AND MAX. 6’-0” LONG ½” FLEXIBLE CONDUIT WHIPS WITH TWO #12 AND #12 GROUND. L. COORDINATE EXIT / EM MOUNTING HEIGHT AT LOCATION SHOWN M. FOR LIGHTING IN EXPOSED STRUCTURE AREAS, EC SHALL PROVIDE UNI-STRUT OR SIMILAR HARDWARE FOR FIXTURE INSTALLATION BETWEEN JOISTS. N. ALL CEILING OR HIGH WALL MOUNTED OCCUPANCY VACANCY, OR DAY LIGHT HARVESTING SENSORS SHALL HAVE A WALL MOUNTED OVERIDE SWITCH IN THE LOCATION SHOWN. LAY-IN CEILING LAY-IN CEILING FLEXIBLE CONDUIT W/#12 WIRE (6' MAX.) LAY-IN CEILING JUNCTION BOX LAY-IN CEILING 12 GAUGE HANGER WIRE OR CHAIN FOR FIXTURE SUPPORT CONNECTED TO STRUCTURE ABOVE SEISMIC CLIP 1 1 D 1 D 2 2 2 OCC PP 3 3 NL D 4 4 4 5 5 D 5 6 D 6 NL NL NL 7 OCW 7 OCC PP NL 8 8 8 3 8 D 9 9 9 NL 4 OCC OCC PP 3 OCC 3 PP 3 3 3 4 4 4 4 3 3 3 4 D 4 D 3 5 OCW 5 6 6 NL NL 8 8 6 OC 13 OC 13 OC 13 7 OCW 7 NLA NLA NL NLA NLB NLB NLB NLB NLB NLB EXIT EXIT 7 7 7 7 7 7 7 7 8 9 SP V SP SP SP V V 11 11 11 11 11 SP V R3 R3 P3 S1 S1 D1 D1 R1 R1 P1 P1 R3 R3 R1 R2 D1 D1 D1 D1 D1 D1 D1 M1 3 R1 R1 R1 R1 R1 R3 R3 R1 R1 R3 R3 R3 R3 D1 D1 D1 D1 D1 D1 3 D1 R2 R2 R2 R2 R2 R2 H-24 NLC H-24 NLC H-24 NLC H-24 NLC H-24 NLC H-24 NLC S1 S1 S1 NLA NLA NLA W1 NLA S1 S1 S1 S1 6 D D D Type MFG Part D1 Intense Lighting SS4G4DS-L4-358 ICS430-HZ-SF I200 M1 Columbia Lighting MPS4-35ML-CW-EDU / CSHC P1 The Original Cast Lighting GB1-XX-04-FS-XX-LED1-35K-UNV-XXDM1 P1- CLUSTER The Original Cast Lighting GB1-P3CA-06-FS-XX-LED1-35K-UNVXX- DM1 P3 The Original Cast Lighting GL1-C1NB-24-MW-XX-LED2-35K-UNVDM1 R1 Axis Lighting B6RLED-800-80-35-RG-4'-W-UNV-DP-1-TXX R2 Axis Lighting B6RLED-800-80-35-RG-2'-W-UNV-DP- 1-TXX R3 Axis Lighting B6RLED-800-80-35-RG-6'-W-UNV-DP- 1-TXX S1 Scott Architectural Lighting S3A15-L05A-935K-XX-XX U1 Axis Lighting BCUC-RUN-XX-80-W-UNV-XX-XX W1 Intense Lighting GD2WS LIGHT FIXTURE SHCEDULE F2 Hubbell Lighting Outdoor RFL3-90L-40-XK7-W-UNV-K-XX H-24 Finelite HP-4 WL R-24'-H-8XX-F-XXV-SC-VF R2 Intense Lighting SS4G4DS-L3-XX8 / ICS432-HZ-SF / I100 S1 Stone Lighting WO877-XX-LED V4 Beacon Products VP-S/36L-80/XK7/4F/UNV/A/BLT Item Note: INSTALLED ON EXISTING POLE. MATCH ADJACENT FIXTURES IN DEVELOPMENT. W1 Performance iN Lighting SHIELD+ 2, TYPE III, 37W EXTERIOR LIGHT FIXTURE SHCEDULE tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME E2-1 ELECTRICAL LIGHTING PLAN KRM 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 SCALE: 1/4" = 1'-0" 3 LIGHT SUPPORT DETAIL SCALE: 1/4" = 1'-0" 1 FIRST FLOOR REFLECTED CEILING PLAN 05/07/21