HomeMy WebLinkAboutE4-1FEEDER SIZES A C B (1) SETS, 3 #3 MCM THWN CU. W/ GRD #8 1 1/2"C 100A (1) SETS, 4 #4/0 MCM THWN CU. W/ GRD #4 2 1/2"C 225A (1) SETS, 3 #600 MCM THWN CU. W/ GRD #3 3 1/2"C 400A D (1) SETS, 4 #1/0 MCM THWN CU. W/ GRD #6 2"C 150A E (2) SETS, 4 #400 MCM THWN CU EACH. W/ GRD #1 3"C 600A F (1) SETS, 4 #300 MCM THWN CU. W/ GRD #4 3"C 250A PAD MOUNT TRANSFORMER ADDENDUM #4 ELECTRICAL RISER DIAGRAM 120 / 208 VOLT 3 PHASE D C B MDP A 100 AMP 100 AMP 100 AMP 60 AMP 60 AMP 1st FLOOR EM PANEL E 150 AMP 42 POLE 3 PHSE. 120 / 208 VOLT ADD NEW 150 AMP SWITCH TO EXTG. MDP FOR NEW E PANEL D TIME CLOCK 2 POLE TIMER INTERMATIC ET8415CR ASTRO 7 DAY EXTG NEW NLA, NLB , NLC FINISH FLOOR FINISH CEILING POWER/ COMMUNICATIONS DEVICES AND SYSTEMS FURNITURE OUTLETS ABOVE COUNTER DEVICES. COORDINATE WITH ARCH. ELEVATIONS AND CABINETRY SHOP DRAWINGS CATV OUTLET AND DEVICES AND MOUNTING BRACKETS WALL -MOUNTED OPERABLE DEVICES PULL STATION WALL -MOUNTED DEVICE W/ SIDE ACCESSIBILITY WALL -MOUNTED DETECTOR 1'-0" DO NOT PLACE DETECTOR IN THIS AREA HORN/ STROBE HORN STROBE CEILING -MOUNTED DETECTOR CEILING -MOUNTED HORN OR HORN/ STROBE 88" 80" 54" 48" 40" 16" 4" 4" GENERAL NOTES: 1. MOUNTING HEIGHTS SHOWN IN THIS DETAIL ARE TYPICAL UNLESS OTHERWISE NOTED ON THE PLANS 2. SEE ARCHITECTURAL ELEVATIONS FOR SPECIAL CONDITIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS. 3. ALL INSTALLATIONS SHALL COMPLY WITH ADA. VISUAL FIRE ALARM NOTIFICATION DEVICES (STROBE) LOCATE DEVICE SO THE BOTTOM OF THE DEVICE IS BETWEEN 80" AND 96" A.F.F. (NFPA) OR 6" BELOW CEILING, WHICHEVER IS LOWER (ADA 2010) 96" AUDIBLE FIRE ALARM NOTIFICATION DEVICES (HORN) LOCATE DEVICE SO THE TOP OF THE UNIT IS NOT MORE THAN 90" A.F.F. AND NOT LESS THAN 6" BELOW CEILING (NFPA) FIRE ALARM ACTIVATION DEVICES (PULL STATION) LOCATE FRONT -APPROACH DEVICES SO THAT THE HIGHEST OPERABLE PORTION OF THE DEVICE IS NOT MORE THAN 48" A.F.F. (ADA 2010) AND NOT LESS THAN 42" A.F.F. (NFPA) POWER/ COMMUNICATION DEVICES: OUTLETS SHALL BE LOCATED AT 16" A.F.F. TO THE BOTTOM OF THE BOX. ABOVE COUNTER DEVICES SHALL BE LOCATED AT 2" ABOVE THE BACKSPLASH OF THE COUNTER TO THE BOTTOM OF THE DEVICES. VERIFY WITH ARCHITECTURAL DETAILS. WALL -MOUNTED OPERABLE DEVICES: OPERABLE DEVICES SHALL BE LOCATED AT 48" A.F.F. TO THE TOP OF THE OPERABLE PORTION OF THE DEVICE. WALL -MOUNTED OPERABLE DEVICES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: PUSH BUTTONS LIGHT SWITCHES, DIMMERS, CONTROLS, ETC. NURSE/ PATIENT CALL DEVICES (INCLUDING THOSE FOR STAFF USE) OTHER CONTROL OR "CALL" DEVICES 8'-8" 10'-6" 8'-0" COUPLING FLUSH WITH FINISH FLOOR COUNTER OUTLET CONDUIT UP TO LIQUIDTIGHT FLEXIBLE CONDUIT FITTING LIQUIDTIGHT FLEXIBLE TYPICALLY MOUNT OUTLETS AT +18" AFF CONDUIT STUB-UP FOR: DATA/COMMUNICATION TO BE 1"C. POWER RECEPTACLES TO BE 3/4"C. FINISHED FLOOR PANEL C PANEL D tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME E4-1 ELECTRICAL RISER & DETAILS DKM 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 SCALE: 3/8" = 1'-0" 3 Standard Mounting Heights SCALE: 3/16" = 1'-0" 4 Undercounter Device Box1 SCALE: 3/8" = 1'-0" 5 Telephone Conduit Stub Detail1 SCALE: 1/4" = 1'-0" 7 Occupancy Sensor Wiring -Multiple Ceiling Mount1 SCALE: 1/4" = 1'-0" 8 Occupancy Sensor Wiring -Single Ceiling Mount1 SCALE: 1" = 1'-0" 6 ELECTRICAL PANELS 05/07/21