HomeMy WebLinkAboutM1-1REF.
DW
MECHANICAL PLAN NOTES
EXHAUST FAN FOR RESTROOMS TO OPERATE WITH OCCUPANCY
SENSORS.
ALL BRANCH SUPPLY DUCT RUNS TO HAVE VOLUME CONTROL
DAMPERS.
NEW DIFFUSER, NEW DUCTWORK. RUN TO LOCATIONS SHOWN.
HVAC CONTRACTOR TO SUPPLY INDEPENDANT AIR BALANCING REPORT
TO ARCHITECT. SEE SPECIFICATIONS FOR APPROVED COMPANYS.
NEW SUPPLY DIFFUSER. RECONNECT, REMOVE OR EXTEND FLEXIBLE
DUCTWORK TO NEW DIFFUSER AS NEEDED. BALANCE TO CFMS
SHOWN. CAP EXTG. DUCTWORK IF EXTG. OPENING NOT USED.
SUPPLY, RETURN OR EXHAUST DUCT, ALL NEW DUCTS TO RUN THRU
JOISTS OR UNDER JOISTS. LOCATION DETERMINED BY FIELD
CONDITIONS. FIELD VERIFY DUCT LOCATIONS BEFORE FABRICATION.
1
2
3
4
5
6
7
20
NEW SUPPLY DIFFUSER. WITH NEW DUCT RUN , ADD FLEXIBLE AS NEEDED.
TIE INTO EXTG. MAIN SUPPLY DUCT. BALANCE TO CFMS SHOWN.
8
NEW EXHAUST GRILLE. TIE INTO EXTG. EXHAUST DUCT ABOUT THIS LOCATION.
EXTG. EXHAUST FAN IS IN THE ATTIC & EXHAUSTS OUT THE EAST SIDEWALL.
EXTG. DAYTON MODEL 1C791 DIRECT DRIVE BLOWER 420 CFM @ .5 SP.
TO OPERATE W/ OCCUPANCY SENSOR.
9
10 REMOVE DIFFUSER, CAP & SEAL ALL EXTG. DUCT WHERE DIFFUSER IS REMOVED.
11 RELOCATE EXTG. THERMOSTAT TO THIS LOCATION.
BASEMENT IS OPEN RETURN AIR PLENUM. ALL EXTG. & NEW PVC TO BE INSULATED
W/ FIRE RETARDENT INSULATION. THIS DUCT IS OPEN TO ABOVE THE CLG. RETURN.
12
H V A C ALTERNATE
ALTERNATE M1, HVAC CONTRCTOR TO SUPPLY ALTERNATE PRICE FOR REPLACING THE EXTG. 2
UNITS IN BASEMENT MECHANICAL ROOM & EXTERIOR AC UNITS.. REUSE EXTG. DUCTWORK
AS NEEDED.
23
ALT. M1. UNIT #1 IN BASEMENT TO HAVE HUMIDITY & DEHUMIDIFICATION EQUIPMENT &
CONTROLS. INCLUDE NEW EQUIPMENT IN ALTERNATE PRICE.
REMOVE EXTG. FLEXIBLE DUCTWORK BACK TO THE UNIT IN BASEMENT. ADD NEW
RIGID SHEET METAL DUCTWORK TO SIZE SHOWN.
13
14 ADD NEW RIGID SHEET METAL DUCTWORK TO SIZE SHOWN. EXTERNALLY INSULATED.
FIELD VERIFY RETURN AIR DUCTWORK SIZE OPENING UP TO ATTIC
15
EXTG. EXHAUST DUCT FROM ATTIC FAN TO BASEMENT TO REMAIN. SEE
BASEMENT HVAC PLAN. RELOCATE CONTROLLER TO THIS LCTN.
EXISTING COMBUSTION AND EXHAUST AIR TO REMIAN. REUSE IN ALTERNATE.
16 RIGID SHEET METAL OUTSIDE AIR DUCT FROM EXTG. UNITS OUT TO NEW LOUVER
ON BUILDING. FIELD VERIFY EXACT LOCATION FOR NEW DUCT.
17 NEW LOUVER ON BUILDING FROM NEW OUTSIDE AIR DUCT. 12" X 16". CUT OUT
EXTTG. BRICK FOR NEW LOUVER. TO BE 10' AWAY FROM ANY EXHAUST OUTLET.
22
BASEBID TO INCLUDE COSA TRON AIR CLEANER INSTALLED ABOVE THE CEILING IN
THE RETURN AIR DUCTWORK THIS LOCATION. CONFIGURE DUCTWORK AS NEEDED
FOR NEW AIR CLEANER. COSA TRON MODEL LC 2000. ROSS BLAUVELT 260-385-1083
EQUIPMENT SUPPLIER.
18 NEW LOUVER ON BUILDING FROM NEW OUTSIDE AIR DUCT. 12" X 16". CUT OUT
EXTTG. BRICK FOR NEW LOUVER. TO BE 10' AWAY FROM ANY EXHAUST OUTLET.
19 REMOVE AIR CLEANER & RETURN TO OWNER. BASEBID TO ALSO INCLUDE
AIRCLEANER COSA TRON AIR CLEANER MDL. LC 2000. INSTALLED IN RETURN
AIR DUCTWORK.
REMOVE EXTG. AIR CLEANER IN BASE BID & RETURN TO OWNER.
ALT M2. SEPERATE ALTERNATE PRICE IS SUPPLYING HUMIDIFICATION AND DEHUMIDIFICATION
EQUIPMENT TO THE EXTG. UNIT #1 IN BASEMENT.
3
6
3
6
S3
S3
3
6
S3
6 S4
6
S3
6
S3
MARKET LEADER
168 SF
114
PARTNER OFFICE
149 SF
113
PARTNER OFFICE
151 SF
111
TELLER
277 SF
BRANCH MANAGER 106
116 SF
110
PARTNER OFFICE
150 SF
102
RR
43 SF
103
VAULT
87 SF
105
?
?
?
VEST.
88 SF
100
LOUNGE
91 SF
115
STAIR
121 SF
101
LIFT
25 SF
109
CUSTOMER
18 SF
104A
6
S3
6
S3
R3
175
6"Ø
150
6"Ø
150
6"Ø
125
6"Ø
7
6
S3
150
6"Ø
6
S3
150
6"Ø
3
3
6 S11
50
6"Ø
100
6"Ø
100
6"Ø
100
6"Ø
150
6"Ø
S11
6 75
6"Ø
9
3
8
S3
400
10"Ø
8
S3
12x12
20"Ø
EXISTING
DUCTWORK
EXISTING
DUCTWORK
EXISTING
DUCTWORK
14
13
14
14
EXISTING
DUCTWORK
475
12x10
900
18x12 1250
20x14
400
10"Ø
2200
24x24
3
775
14x12
800
16x10
4
S11
50
6"Ø
100
6"Ø
R2
R2
16
14
14
R3
R3
R3
R3
R3
R3
R3
IN ATTIC
13
14
14
14
16
345
12x8
17
17
EM
R4
10'
MIN
75
6"Ø
MD2
RAW
U1
U2
U3
T
EXISTING
EXHAUST
DUCT
AC
AC
6
S3
150
6"Ø
3
KITCHEN
160 SF
012
COMMUNITY ROOM
295 SF
013
OFFICE
118 SF
011
RR
41 SF
009
RR
55 SF
008
STOR
19 SF
007
MECH/ELEC
195 SF
005
WORKROOM
98 SF
003
STORAGE
89 SF
004
OFFICE
147 SF
002
RISER
66 SF
016
STOR.
36 SF
015
OFFICE
180 SF
014
CIRC
384 SF
001
CIRC
51 SF
010
3
6
S3
175
6"Ø
3
S3 6
150
6"Ø
6
S3
150
6"Ø
S3 6
200-
8"Ø
3
3
S3 6
125
6"Ø
S11
6
50
6"Ø
R2
7
9
9
6"Ø
9
S11
6 50
6"Ø
3
10
11 T
11
3
RAW
20
6
S3
125
6"Ø
EXISTING
DUCT
R2 R2
R2
9
6
EXISTING
DUCT
7
7
6
S3
150
6"Ø
EXISTING
DUCT
600 725 825 1150
S11
6 50
6"Ø
1250
S3 6
100
6"Ø
1475
S3 6
50
6"Ø
R3 R3
R3
15
MD1
345
12x8
MD1
8x6
MDP
C B D
345
12x8
16
EM
AC
AC
19
19
19
19
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.
REVISIONS
DRAWING NAME
M1-1
HVAC PLAN
KRM
20128
02/12/2021
BID SET
4775 E 126th St Carmel IN 46033
STATE BANK
20128 - CARMEL BRANCH
BID SET
02/12/2021
SCALE: 1/4" = 1'-0"
2
HVAC FIRST FLOOR PLAN
SCALE: 1/4" = 1'-0"
3
0 - HVAC BASEMENT FLOOR PLAN
05/07/21