Loading...
HomeMy WebLinkAboutM2-1DD #4 T SIDEWALL GRILLE SIDEWALL GRILLE EXHAUST AIR DUCT DETECTOR EA THERMOSTAT & VAV BOX IT CONTROLS EXHAUST FAN I T E M SUPPLY AIR GRILLE HVAC L E G E N D RETURN AIR GRILLE INSULATED FLEX DUCT MAX. 5' RIGID INSULATED SUPPLY DUCT W/ CFM DUCT SIZE DIMENSION # IS WIDTH RIGID INSULATED RETURN DUCT LENGTH SYMBOL AIRFLOW 8X12 650 LINEAR SLOT DIFFUSER CONDENSATE LINE CEILING HUNG HUMIDIFIER C CONDENSER WALL MOUNTED INDOOR SPLIT SYSTEM UNIT HEATER SUPPLY AIR GRILLE MOUNTED ON DUCT FD 1 HOUR FIRE DAMPER IN DUCTWORK EXHAUST FAN MD MOTORISED DAMPER CO CARBON DIOXIDE SENSOR RETURN AIR GRILLE WALL RAW HF EXTERIOR LOUVER 1-1/2" x 20 GA. GALV. SHEET METAL STRIP C/W ONE LOAD RATED FASTENER W/O DISFIGURING SHAPE HANGER STRAPS TO BE MAX. 24" SPACING TO HANG DUCT W/O SAGGING 3" OVERLAP C/W 2 LOAD RATED FASTENERS 1-1/2" x 20 GA. GALV. SHEET METAL STRIP C/W ONE LOAD RATED FASTENER HANGER STRAPS TO BE MAX. 4' SPACING 3" OVERLAP C/W 2 LOAD RATED FASTENERS BLANKET INSULATION SEALED VAPOR TIGHT C/W MASTIC & FABRIC TAPE 4" WIDE HANGER STRAPS TO BE MAX. 6" SPACING 3" OVERLAP C/W 2 LOAD RATED FASTENERS ONE LOAD RATED FASTENER TO ATTACH STRAP TO UNDERSIDE OF RECTANGULAR DUCT BLANKET INSULATION SEALED VAPOR TIGHT ALONG ALL SEAMS AND HANGERS C/W MASTIC 1-1/2" X 20 GA. GALV. SHEET METAL STRIP C/W ONE LOAD RATED FASTENER W/O DISFIGURING SHAPE INSULATED CONDENSATE DRAIN PIPE SLOPE TO AN APPROVED TERMINATION POINT. EXCLUDE INSULATION FOR RTU APPLICATION. SAME SIZE AS EQUIPMENT CONDENSATE OUTLET CONDENSATE DRAIN FROM COOLING COILS THREADED CLEANOUT PLUG ROUND NECK DUCT ADAPTER HEAT SHIELD INSULATING BLANKET T-BAR CEILING GRID WHERE SHOWN ON ARCH. PLANS ACOUSTICAL TILE CEILING ADJUSTABLE DAMPER SURFACE MOUNTING WHERE SHOWN ON PLANS CEILING DIFFUSER MECH. CONTRACTOR SHALL PROVIDE STRUCTURAL SUPPORT IF REQUIRED FOR DIFFUSER SUPPORT. GYP BOARD CEILING. RIGID METAL ELL 1-1/2" DIA. ELBOW HEAT SHIELD INSULATING BLANKET ALL AROUND 1" AIA. RIGID STRAIGHT DUCT FLEXIBLE INSULATED DUCT WITHOUT SAGS SUPPLY DUCT 1. ALL DUCTS AND DEVICES MUST BE INSTALLED USING WRAP INSULATION AS SPECIFIED. 2. OVERLAP FLEX AND DUCT WRAP AT JUNCTIONS RECTANGULAR TAKE-OFF WITH TRANSITION TO ROUND DUCT COLLAR C/W CLAMP DEVICE FLEXIBLE DUCT TO DIFFUSER ROUND METAL MANUAL BALANCING DAMPER FLEXIBLE DUCT SIZE TO BE SAME AS DIFFUSER NECK SIZE INSULATION MUST BE PROVIDED ON ALL METAL DUCT INSTALLED SUPPLY DUCT AIR FLOW 1 TO 2 HOUR RATED WALL 12 GA. STEEL ANGLE DUCT 20 GA. SLEEVE STEEL ANGLE 1-1/2" X 1-1/2" X 12 GA. SLIP CONNECTION ACCESS PANEL FIRE DAMPER - TYPE "B" NAILOR HART MODEL 0120 1-1/2 HR. U.L. LABELED tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME M2-1 MECHANICAL DETAILS & SCHEDULES KRM 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 05/07/21