HomeMy WebLinkAboutM2-2OF DIFFUSER FLEXIBLE DUCT UPSTREAM MAXIMUM OF 5' OF PATTERN CONTROLLER VOLUME NOT TAPED VALVE CEILING FLOW RIGID DUCT DAMPER AIR TO BE BANDED CONNECTIONS FLEX. DUCT FLEXIBLE DUCT SQUARE THROAT WITH TURNING VANES RETURN AIR TRANSITION SUPPLY AIR RADIUS ELL CENTERLINE RADIUS OF RECTANGULAR DUCT MUST MATCH SMALLER DIMENSION OF DUCT. USE TO TRANSITION RTU SUPPLY DROP TO MAIN TRUNK. WRAP FIBERGLASS INSULATION WITH FACTORY APPLIED FOIL VAPOR BARRIER WITH A PERMEANCE OF 0.02 OR LESS. MINIMUM INSTALLED R VALUE = 6. INSULATION MUST BE INSTALLED DRY. CUT INSULATION TO PROPER LENGTH TO AVOID DISFIGURING OF INSULATION RIGID DUCT ALL DUCT OVER 24" WIDE TO BE SECURELY INSULATED WITH WELDED STICK PINS STAPLE 2" FLANGE WITH TAPE OVER JOINT WITH STAPLE TO PROVIDE VAPOR TIGHT SEAL. ALL SEAMS TO BE SEALED WITH HARDCAST. SEQUENCE OF OPERATION UNITS 1,2, OCCUPIED MODE UNIT TO CYCLE ON & OFF TO PROVIDE HEAT & COOL AS NEEDED. OUTDOOR AIR MODULATING DAMPER TO BRING IN THE MINIMUM AMOUNT OF OUTSIDE AIR INTO THE SPACE ACCORDING TO OUTSIDE AIR VENTILATION REQUIREMENTS ON SHEET M2-2. UNOCCUPIED MODE, OUTSIDE AIR DAMPERS TO CLOSE & HEAT & COOL TO CYCLE ON & OFF AS CALLED FOR BY THE THERMOSTAT. 1 THERMOSTAT HONEYWELL VISION PRO TOUCH SCREEN PRESTIGE #THX 9421 DUAL FUEL THERMOSTATS ON UNITS #4 & #5. (1) YL7220A7503 Jade Economizer Kits Each kit includes the following. (1) W7220A1000 Jade Economizer (1) C7250A1000 Outside Temperature Sensor (1) C7250A1000 Return Air Temperature Sensor Honeywell MS7505A2030 damper actuator main outside air intake damper. to be interlocked to open whenever any one of the 2, units operate in the occupied mode. 1, MD 12" X 16" with LOW VOLTAGE ACUATOR 2, MD 10" X 8" with LOW VOLTAGE ACUATOR SIDEWALL LOUVER GREENHECK ESD-603 EXTERIOR COLOR TO BE SLCTD. 12" X 16" S6 32"X32" T&B AIG-H DISCHARGE GRILLES. INTAKE LOUVER RUSKIN #ELF820DD 12"X16" W/ BACKDRAFT GASKETED DAMPER R4 20" X 8" SUPPLY AIR GRILLE MOUNTED ON SIDE OF DUCT W/ VOLUME CONTROL 6" X 12" SUPPLY AIR GRILLE MOUNTED ON SIDE OF DUCT W/ VOLUME CONTROL TITUS S300FL TITUS LINEAR BAR DIFFUSER FL-15 1, SLOT 1.5" WIDE 4' LONG MOUNTED TO CEILING NECK SIZES RETURN AIR GRILLES A 18 X 16 B 20 X 10 C 20 X 12 D 18 X 14 E 14 X 20 F 6 X 6 G 10 X 10 H 8 X 8 I 8 X 6 J 16 X 12 K 20 X 20 L 14 X 20 M 28 X 28 600 42" X 42" 700 - 800 200 100 - 175 1200 - 1350 1000 TITUS 50F 250 - 350 400 - 450 18"X48" DOUBLE DEFLECTION DUCT MOUNTED. TIN COLORED TITUS 300 W/ VOLUME CONTROL. S7 SHOEMAKER ADJUSTABLE # 945 12" X 6" S5 GRILLES & DIFFUSERS SUPPLY GRILLE TITUS 12" X 12" OMNI WHITE SUPPLY GRILLE TITUS 12" X 12" OMNI WHITE SUPPLY GRILLE TITUS 24" X 24" OMNI WHITE S2 S3 S1 S11 SUPPLY GRILLE TITUS 16" X 4" 300FS SYMBOL DESIGNATION MODEL NECK SIZE MAX AIRFLOW RETURN GRILLE TITUS 50F EGGCRATE 12" X 12" 240 CFM R1 R2 RETURN GRILLE TITUS 50F 24" X 48" RETURN GRILLE TITUS 50F EGGCRATE 24" X 24" R3 S4 S8 S9 S10 TITUS LINEAR BAR DIFFUSER FL-20 1, SLOT 2" WIDE 2' LONG MOUNTED TO CEILING OR WALL INTERGRAL PATTERN CONTROLLER S12 SHOEMAKER ADJUSTABLE # 945 16 X 6 S13 INTERGRAL PATTERN CONTROLLER MODEL MANUFACTURER AREA SERVED SEER VOLTAGE / PHASE / FREQUENCY HEATING CAPACITY (BTU) INPUT MAX. FUSE SIZE BY(EC) AIRFLOW (CFM) MCA EQUIPMENT NOTES CONTROLED BY OCC SENSORS H VAC EQUIPMENT ID # 80 cfm @ .2 SP EXHAUST FAN EF 120/1/60 BROAN ARW80L RESTROOMS LENNOX 1ST FLOOR UNIT #1 BASEMENT LENNOX UNIT #2 2 UNITS TWINNED TOGETHER 4000 CFM 2000 EACH 180 K BTU 90 EACH COOLING CAPACITY (BTU) 96 K BTU 48 K EACH 120 V / 60 / 1 208 V / 60 / 3 ALTERNATE M2. DEHUMIDIFICATION & HUMIDIFICATION, PROVIDE SEPERATE ALTERNATE PRICE FROM THE REPLACING HVAC EQUIPMENT ALTERNATE. * * EL16XP1-060-230 Heat Pump 5.0 ton C35-60D-2F-1 Coil/5 Ton/Cased EL296UH135XV60D Furnace-Gas/135Btuh/5Ton 94M43 1 EDA-060D Dehumidification System Field Installed 98M62 1 EDA Insulation & Piping Kit Field Installed Y2788 1 Healthy Climate® Power Humidifier HCWP3-18 Field Installed 12J20 1 Thermal Expansion Valve 3.5 - 5 Tons Field Installed * * UNIT #1 * * * ELS090S4D-230-3-E (2)CX35-48C-F, COILS (2) ML193UH090P48C 1) THESE DRAWINGS INDICATE REQUIRED SIZES AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT NECESSARY OFFSETS AND FITTINGS MAY NOT BE SHOWN. CONTRACTOR SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFIRM WITH THE STRUCTURE UNLESS DOING SO VIOLATES GOVERNING CODES. ALL DIMENSIONS SHOWN ON THESE PLANS ARE IN FEET AND/ OR INCHES UNLESS OTHERWISE NOTED. 2) CONTRACTOR SHALL BE GUIDED BY THE ARCHITECT'S REFLECTED CEILING PLAN FOR EXACT LOCATION OF DIFFUSERS, REGISTERS AND GRILLES UNLESS OTHERWISE NOTED. 3) DUCTS PENETRATING FLOOR SLABS AND/OR WALLS SHALL BE SEALED AS REQUIRED BY CODE. DUCTS PENETRATING FIRE RATED WALLS AND/OR FLOORS SHALL HAVE OPENING AROUND DUCT SEALED WITH A MATERIAL HAVING THE SAME FIRE RATING AS THE WALL OR FLOOR. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS OR FLOORS. 4) ALL TRENCHES WITHIN THE CONFINES OF THE BUILDING SHALL BE KEPT AWAY FROM FOOTINGS A DISTANCE OF ONE FOOT HORIZONTAL FOR EACH FOOT OF DEPTH BELOW THE NEAREST FOOTING, OR TRENCH SHALL BE FILLED WITH CONCRETE TO AN ELEVATION SUCH AS TO ESTABLISH THE REQUIRED ONE-FOR-ONE RATIO OR PROXIMITY. 5) DIFFUSERS, GRILLES AND REGISTERS LOCATED IN GYP. BOARD CEILINGS SHALL HAVE PLASTER FRAMES. 6) EXPOSED DUCTWORK SHALL BE ROUND SPIRAL PIPE UNLESS OTHERWISE NOTED. 7) MECHANICAL CONTRACTOR SHALL PREFORM TEST READINGS ON ALL NEW FANS AND UNITS, AND ADJUST SPEED TO DELIVER SPECIFIED QUANTITY OF AIR. A TEST AND BALANCEING REPORT LOG SHALL BE MADE SHOWING ALL AIR SUPPLY QUANTITIES, FAN AND UNIT TESTING READINGS, ETC., AND SHALL BE SUBMITTED TO THE ENGINEER BEFORE FINAL INSPECTION OF THE PROJECT. ALL EQUIPMENT SHALL BE ADJUSTED TO OPERATE AS INTENDED BY THE SPECIFICATIONS. ALL THERMOSTATS AND CONTROL DEVICES SHALL BE ADJUSTED TO OPERATE AS INTENDED. ADJUST BURNERS, FANS, ETC., FOR PROPER AND EFFICIENT OPERATIONS. ADJUST ALL SUPPY OULETS TO SUPPLY THE AMOUNT OF AIR SHOWN ON DRAWINGS. CALIBRATE, SET AND ADJUST ALL AUTOMATIC TEMPERATURE CONTROLS. CHECK PROPER SEQUENCING OF ALL INTERLOCK SYSTEMS. 8) LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE OVER DIFFUSER AND GRILLE LOCATIONS. LOCATE DIFFUSERS AND GRILLES TO ACCOMMODATE LIGHTING LAYOUTS. 9) MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONTROL VOLTAGE COMPONENTS & WIRING INCLUDING NECESSARY CONDUIT BETWEEN DEVICES. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR SUBCONTRACTING ANY OF THIS WORK TO A QUALIFIED ELECTRICAL CONTRACTOR LICENSED FOR WORK IN THE JURISDICTION OF THIS PROJECT. ELECTRICAL SUBCONTRACTOR MUST BE APPOVED BY THE G.C. ALL CHANGE ORDERS SUBMITTED BY THE ELECTRICAL SUBCONTRACTOR SHALL BE ABSORBED BY MECHANICAL CONTRACTOR. DESIGNATED PROJECT ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO DEVICE OR DEVICE CONTROLLER PER PLANS. 10) ALL TAKEOFFS FROM BRANCH DUCTS TO INDIVIDUAL DIFFUSERS, GRILLES, AND REGISTERS SHALL HAVE A SPIN-ON TYPE DUCT CONNECTOR WITH BALANCING DAMPER AND LOCKING QUADRANT. 11) SEALANTS USED ON DUCT SYSTEMS SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPMENT CLASSIFICATION OF NOT MORE THAN 50 OR AS PER LATEST BUILDING CODE RUQUIREMENTS. ALL SEAMS, JOINTS, CORNERS, ETC. ARE TO BE SEALED TO MAKE DUCT COMPLETELY AIR TIGHT. 12) DUCT INSULATION: PROVIDE 1 1/2 LB/CU. FT. DENSITY WRAP INSULATION WITH VAPOR RETARDING JACKET WITH FSK FINISH. COVER ALL SUPPLY AIR DUCTS, SILENCERS, TERMINALS, OUTSIDE AIR INTAKES, EXHAUST AIR DUCTS WITH 1-1/2" THICK INSULATION R-6 MINIMUM. ALL JOINTS SHALL BE TIGHTLY BUTTED. TAPE ALL JOINTS AND COVER ALL PIN PENETRATIONS WITH 4" RFFRK TAPE TO PROVIDE A COMPLETE VAPOR BARRIER ENVELOPE. A) EXTERNALLY INSULATE ALL SUPPLY AND RETURN METAL DUCTS WITH ABOVE WRAP EXCEPT VERTICAL DROPS FROM ROOFTOP UNITS. DROPS FROM ROOFTOP UNITS SHALL BE INTERNALLY INSULATED WITH 1" DUCT LINER. DUCT LINER SHALL MEET ASTM C 1071, TYPE 1, FLEXIBLE, ASTM G21 AND G22, NFPA 90A AND 90B, FHC 25/50 AND LIMITED COMBUSTIBILITY. INSTALL ACCORDING TO SMACNA AND NAIMA FIBROUS GLASS DUCT LINER APPLICATION STANDARDS. 13) FLEXIBLE DUCT: HART & COOLEY MODEL F216, METALIZED VAPOR BARRIER, R-6 INSULATION, UL-181 RATED AND INSTALLED BY ASTM C-518 STANDARDS. FLAME SPREAD LESS THAN 25, SMOKE DEVELOPED LESS THAN 50. DUCT SHALL BE INSTALLED LEVEL WITH MINIMAL BENDS AND SUPPORTED AS REQUIRED PER DETAIL. 14) ALL MECHANICAL EQUIPMENT MOUNTED ON THE ROOF SHALL BE PLACED AT LEAST 10'-0" AWAY FROM ANY EDGE OR CHANGE IN ROOF ELEVATION. 15) ALL DISCONNECTS FOR MECHANICAL EQUIPMENT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 16) ALL STARTERS AND DISCONNECTS FOR MECHANICAL EQUIPMENT SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. H V A C PLAN NOTES 17) ELECTRICAL CONTRACTOR RESPONSIBLE FOR INSTALLING & CONNECTING THE FIRE ALARM SYSTEM ALL DUCT DETECTORS. SEE ELECTRICAL PLANS FOR LOCATIONS. 49 CFM 150 CFM UNI AREA SERVED OUTSIDE AIR VENTILATION REQUIREMENT TABLE VENTILATION REQUIRED VENTILATION OUTSIDE AIR UNIT VENTILATION OA DELIVERED TO ROOMS EXHAUST AIR HUMIDITY CONTROL UNIT 1 BANK / OFFICE SPACES RESTROOMS 2 X 75CFM 1954 SF /5 PPL. 1000PSF X 5 CFM PP + .06 CFM PSF 52 CFM BANK / OFFICE SPACES 2100 SF /5 PPL. 1000PSF X 5 CFM PP + .06 CFM PSF UNIT 2 MOTORIZED DAMPERS MD1 10 X 8 LOW VOLTAGE CONNECTION 118 CFM 167 CFM 126 CFM 178 CFM 75 CFM MD2 14 X 10 tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME M2-2 MECHANICAL DETAILS & SCHEDULES KRM 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 8-7-19 SCALE: 1" = 1'-0" 3 AIR CLEANER 05/07/21