HomeMy WebLinkAboutP2-1WALL FOOTING OR FOUNDATION
(SEE STRUCTURAL DRWG'S.)
PIPE SLEEVE TO BE
TWO (2) PIPE SIZES
LARGER THAN SERVICE 12"
24"
BLDG. FLOOR
CAULKED (TYPICAL)
SEAL ANNULAR SPACE BETWEEN
ASPHALTUM COMPOUND, TIGHTLY
PIPE & SLEEVE WITH OAKUM
BOTTOM OF FOOTING & TOP
MIN. 3" CLEARANCE BETWEEN
12"
24"
OF SLEEVE
BUILDING WALL
FINISH GRADE
NO PIPING TO
BE INSTALLED BELOW 45° FOOTING
CUT-OFF LINE.
COLUMN OR WALL
FOOTING
PIPE ACCEPTABLE
PIPE NOT ACCEPTABLE
PIPE ACCEPTABLE
PIPE ACCEPTABLE
45°
MIN.
30°
3'-0"
FIN. FLOOR
PIPE
NO SCALE
PASSING UNDER FOOTER B
TYPICAL PIPE
NO SCALE
PASSING NEXT FOOTER A
TYPICAL PIPE
P L U M B I N G L E G E N D
CO
FD
I T E MSYMBOL
GR
SS
ST
BFP
G
WATER CONNECTION TO PLUMBING FIXTURE
WITH SHUT OFF
R HOTWATER RECIRCULATION LINE
CLEANOUT
FLOOR DRAIN W/ CLEANOUT
SANITARY LINE OIL GREASE
GAS LINE
SHUT OFF VALVE
HOTWATER LINE
COLDWATER LINE
DROP IN STAINLESS STEEL SINK
SELF RIMMING LAVATORY
FLUSH VALVE WATER CLOSET FREEZE PROOF HOSE BIB
THERMOMETER
BALL SHUT OFF VALVE
WALL HUNG LAVATORY
CHECK VALVE
BACK FLOW PREVENTER
PVC VENT LINE
SETIMENT TRAP IN GAS LINE
GAS REGULATOR
FSCV
FIRE SERVICE DOUBLE DETECTOR CHECK
VALVE
ST STORMWATER PIPE
WCO WALL CLEANOUT
S SANITARY SEWER LINE
RH RADIANT HEATER LOCATION SM SANITARY SEWER MANHOLE
X
COMPRESSED AIR DROP LOCATION CA COMPRESSED AIR LINE
CW
HW
FDC FIRE DEPT. CONNECTIONCA COMPRESSED AIR DROP
RO REVERSE OSMOSIS SYSTEM SPIGET
CHIP CUP
ADJUSTABLE SWIVEL
RING
3/8" DIA. ROD
C -CLAMP
STEEL BAR JOIST REFER
TO STRUCTURAL DWGS.
ROOF STRUCTURE
ROLL LEAD FLASHING 1" DOWN INTO PIPE
PLUMBING VENT STACK
MODIFIED BITUMEN FLASHING STRIP
MODIFIED BITUMEN MEMBRANE
WITH SURFACING OR COATING
SET LEAD FLANGE IN MASTIC-
PRIME FLANGE BEFORE
STRIPPING
MODIFIED BITUMEN SHEET
12" MIN.
4" MIN.
NOTE: SHEET LEAD MIN. OF 2 1/2
POUNDS PER FOOT SQUARE
GRADE OR PAVING COVER FOR DUTY REQUIRED
6" THICK CONCRETECLEANOUT ASSEMBLY
SAME SIZE AS SEWER UP TO 8" DIA.
SEWER MATERIAL AND SIZE AS SPECIFIED VARIESC.W.H.W. WST. VNT.
CONNECTIONS
FIXTURESMK.
PLUMBING FIXTURE SCHEDULE
A
WATER CLOSET TANK TYPE
1/2"4" 1 1/2"
1/2"1" 1/2"
FLOOR DRAIN
EQUAL TO JR SMITH MDL. #2010
CAST IRON BODY & FLASHING COLLAR
NICKEL-BRONZE ROUND ADJUSTABLE STRAINER HEAD, SECURE SQUARE HOLE
GRATE
CHICAGO FAUCET 201 -AGNA8E2805-5 DECK MOUNTED 8" CENTERS W/
RIGID / SWING VANDAL RESISTANT AERATOR EQUAL TO ZURN AQUASPEC.
2 GPM, PERFORATED GRID STRAINER EQUAL TO ELKAY
HEAVY DUTY SUPPLIES W/ LOOSE KEY ANGLE STOPS, EQUAL TO ZURN.
ANSI # A112.19.2 2M-95 W/ SPRAYER
D
FD1
2" 1 1/2" 1/2"1/2"
B
LAVATORY
C
SINGLE BOWL STAINLESS STEEL DROP IN SINK
1/2"2" 1 1/2" 1/2"
ELKAY #DD23322
33"X22"X7" W/ FAUCET LEDGE.
1/2"
Wellworth®
Pressure Lite® Toilet
K-3505
KOHLER WELLWORTH PRESSURE LITE TOILET K-3505 W/ ELONGATED SEAT
WATER CLOSET TANK TYPE ADA
4" 1 1/2" KOHLER WELLWORTH PRESSURE LITE TOILET K-3493 -RA
WITH ELONGATED SEAT
AMERICAN STANDARD DECORUM WALL-HUNG LAVATORY WITH EVERCLEAN
VITREOUS CHINA MDL # 9024.001 EC CENTER HOLE ONLY
AMERICAN STANDARD MOMENTS SELECTRONICS MDL. # 250B.105 .5 GPM
POWER KIT MDL. # PK00.PAC AC PLUG IN
E
GARBAGE DISPOSAL
2" 1 1/2"1/2 HP BADGER IN SINK ERATOR
SIDEWALL DRAIN
4"Zurn Z187, 4" 90° Threaded Outlet Scupper DrainF
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.REVISIONSDRAWING NAME
P2-1
PLUMBING DETAILS
& SCHEDULES
KRM
20128
02/12/2021
BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE: 1/2" = 1'-0"10 Pipe Hanger Detail1
SCALE: 1/2" = 1'-0"11 Plumbing Vent Thru Roof Detail1
SCALE: 1/2" = 1'-0"12 Two Way Cleanout Detail1 8-7-1905/07/21