Loading...
HomeMy WebLinkAboutP2-1WALL FOOTING OR FOUNDATION (SEE STRUCTURAL DRWG'S.) PIPE SLEEVE TO BE TWO (2) PIPE SIZES LARGER THAN SERVICE 12" 24" BLDG. FLOOR CAULKED (TYPICAL) SEAL ANNULAR SPACE BETWEEN ASPHALTUM COMPOUND, TIGHTLY PIPE & SLEEVE WITH OAKUM BOTTOM OF FOOTING & TOP MIN. 3" CLEARANCE BETWEEN 12" 24" OF SLEEVE BUILDING WALL FINISH GRADE NO PIPING TO BE INSTALLED BELOW 45° FOOTING CUT-OFF LINE. COLUMN OR WALL FOOTING PIPE ACCEPTABLE PIPE NOT ACCEPTABLE PIPE ACCEPTABLE PIPE ACCEPTABLE 45° MIN. 30° 3'-0" FIN. FLOOR PIPE NO SCALE PASSING UNDER FOOTER B TYPICAL PIPE NO SCALE PASSING NEXT FOOTER A TYPICAL PIPE P L U M B I N G L E G E N D CO FD I T E MSYMBOL GR SS ST BFP G WATER CONNECTION TO PLUMBING FIXTURE WITH SHUT OFF R HOTWATER RECIRCULATION LINE CLEANOUT FLOOR DRAIN W/ CLEANOUT SANITARY LINE OIL GREASE GAS LINE SHUT OFF VALVE HOTWATER LINE COLDWATER LINE DROP IN STAINLESS STEEL SINK SELF RIMMING LAVATORY FLUSH VALVE WATER CLOSET FREEZE PROOF HOSE BIB THERMOMETER BALL SHUT OFF VALVE WALL HUNG LAVATORY CHECK VALVE BACK FLOW PREVENTER PVC VENT LINE SETIMENT TRAP IN GAS LINE GAS REGULATOR FSCV FIRE SERVICE DOUBLE DETECTOR CHECK VALVE ST STORMWATER PIPE WCO WALL CLEANOUT S SANITARY SEWER LINE RH RADIANT HEATER LOCATION SM SANITARY SEWER MANHOLE X COMPRESSED AIR DROP LOCATION CA COMPRESSED AIR LINE CW HW FDC FIRE DEPT. CONNECTIONCA COMPRESSED AIR DROP RO REVERSE OSMOSIS SYSTEM SPIGET CHIP CUP ADJUSTABLE SWIVEL RING 3/8" DIA. ROD C -CLAMP STEEL BAR JOIST REFER TO STRUCTURAL DWGS. ROOF STRUCTURE ROLL LEAD FLASHING 1" DOWN INTO PIPE PLUMBING VENT STACK MODIFIED BITUMEN FLASHING STRIP MODIFIED BITUMEN MEMBRANE WITH SURFACING OR COATING SET LEAD FLANGE IN MASTIC- PRIME FLANGE BEFORE STRIPPING MODIFIED BITUMEN SHEET 12" MIN. 4" MIN. NOTE: SHEET LEAD MIN. OF 2 1/2 POUNDS PER FOOT SQUARE GRADE OR PAVING COVER FOR DUTY REQUIRED 6" THICK CONCRETECLEANOUT ASSEMBLY SAME SIZE AS SEWER UP TO 8" DIA. SEWER MATERIAL AND SIZE AS SPECIFIED VARIESC.W.H.W. WST. VNT. CONNECTIONS FIXTURESMK. PLUMBING FIXTURE SCHEDULE A WATER CLOSET TANK TYPE 1/2"4" 1 1/2" 1/2"1" 1/2" FLOOR DRAIN EQUAL TO JR SMITH MDL. #2010 CAST IRON BODY & FLASHING COLLAR NICKEL-BRONZE ROUND ADJUSTABLE STRAINER HEAD, SECURE SQUARE HOLE GRATE CHICAGO FAUCET 201 -AGNA8E2805-5 DECK MOUNTED 8" CENTERS W/ RIGID / SWING VANDAL RESISTANT AERATOR EQUAL TO ZURN AQUASPEC. 2 GPM, PERFORATED GRID STRAINER EQUAL TO ELKAY HEAVY DUTY SUPPLIES W/ LOOSE KEY ANGLE STOPS, EQUAL TO ZURN. ANSI # A112.19.2 2M-95 W/ SPRAYER D FD1 2" 1 1/2" 1/2"1/2" B LAVATORY C SINGLE BOWL STAINLESS STEEL DROP IN SINK 1/2"2" 1 1/2" 1/2" ELKAY #DD23322 33"X22"X7" W/ FAUCET LEDGE. 1/2" Wellworth® Pressure Lite® Toilet K-3505 KOHLER WELLWORTH PRESSURE LITE TOILET K-3505 W/ ELONGATED SEAT WATER CLOSET TANK TYPE ADA 4" 1 1/2" KOHLER WELLWORTH PRESSURE LITE TOILET K-3493 -RA WITH ELONGATED SEAT AMERICAN STANDARD DECORUM WALL-HUNG LAVATORY WITH EVERCLEAN VITREOUS CHINA MDL # 9024.001 EC CENTER HOLE ONLY AMERICAN STANDARD MOMENTS SELECTRONICS MDL. # 250B.105 .5 GPM POWER KIT MDL. # PK00.PAC AC PLUG IN E GARBAGE DISPOSAL 2" 1 1/2"1/2 HP BADGER IN SINK ERATOR SIDEWALL DRAIN 4"Zurn Z187, 4" 90° Threaded Outlet Scupper DrainF tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO.REVISIONSDRAWING NAME P2-1 PLUMBING DETAILS & SCHEDULES KRM 20128 02/12/2021 BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE: 1/2" = 1'-0"10 Pipe Hanger Detail1 SCALE: 1/2" = 1'-0"11 Plumbing Vent Thru Roof Detail1 SCALE: 1/2" = 1'-0"12 Two Way Cleanout Detail1 8-7-1905/07/21