Loading...
HomeMy WebLinkAbout20210225_Addendum 1 TTV S AC AC EH EH TR SCV TTV S AC AC EH EH TR SCV 3 AS1-1 2 AS1-1 MILL AND FILL ASPHALT PARKING LOT AND RESTRIPE NEW PLANTINGS PROPERTY LINE LAWN LAWNLAWN S-1 S-4 P-1 S-5 S-5 S-1 S-3 P-1 S-6 T-1 S-6 MULCH PLANTING BED STONE PLANTING BED P-1 S-2 S-2 S-5 S-1 CONCRETE PAVER ENTRYWAY P-1 S-5 126th STREET GRAY ROADBROOKSHIRE PLAZA DEVELOPMENT BUFFERYARD S-6 S-6 P-1 10'-0"MECHANICAL ENCLOSURE TRASH ENCLOSURE 1 1 3 3 3 3 4 S-5 FLAG POLE, 25' TALL WITH BASE LIGHTING, CFCI 2 5'-0" 5'-0"6'-0"12'-0" 6'-0" 6'-0" PAINTED MARKINGS, TYP PAINTED MARKINGS, TYP 4 AS1-1 6 AS1-1 7'-6"10'-0"6'-0"3'-8" 3'-8" EXISTING GAS LINE, VERIFY LOCATION AND PROTECT. ADJUST LOCATION OF ENCLOSURE AS NEEDED. REMOVE EXISTING PLANTINGS AND GROUND COVER COMPLETELY 1 REMOVE EXISTING PLANTINGS AND GROUND COVER COMPLETELY 1 REMOVE EXISTING PLANTINGS AND GROUND COVER COMPLETELY 1 6'-3"> 5"SOLID SWING GATE WITH CANE BOLT ALUMINUM SLAT INFILL PANEL 10"D X 2'-6" CONCRETE FOOTINGS 4"X4" ALUMINUM POST ALUMINUM TRASH ENCLOSURE SYSTEM, REF SPEC 05 50 00 4'-0" 6'-0" ALUMINUM SLAT INFILL PANEL 10"D X 2'-6" CONCRETE FOOTINGS 4"X4" ALUMINUM POST ALUMINUM TRASH ENCLOSURE SYSTEM, REF SPEC 05 50 00 6'-0" 6'-0"6'-3"10"D X 2'-6" CONCRETE FOOTINGS 4"X4" ALUMINUM POST ALUMINUM TRASH ENCLOSURE SYSTEM, REF SPEC 05 50 00 SOLID SWING GATE WITH CANE BOLT ALUMINUM SLAT INFILL PANEL 6'-3"4'-0" 6'-0" ALUMINUM SLAT INFILL PANEL 10"D X 2'-6" CONCRETE FOOTINGS 4"X4" ALUMINUM POST ALUMINUM TRASH ENCLOSURE SYSTEM, REF SPEC 05 50 00 6'-3"3'-8" 3'-8" tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO.REVISIONSDRAWING NAME AS1-1 ARCHITECTURAL SITE PLAN Author 20128 02/12/2021 BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:1" = 10'-0" 1 LANDSCAPE/SIGNAGE PLAN EXTERIOR SIGNAGE SCHEDULE - CFCI 1 ILLUMINATED BUILDING-MOUNTED SIGNAGE 2 MAXIMUM HEIGHT SIGNAGE, LESS THAN 3 SF 3 DIRECTIONAL SIGNAGE LESS THAN 3SF 4 PARKING SIGNAGE LESS THAN 3SF SCALE:1/4" = 1'-0"2 ELEVATION - TRASH ENCLOSURE FRONT SCALE:1/4" = 1'-0"3 ELEVATION - TRASH ENCLOSURE SIDE PLANTING MATRIX TREES SHRUBS BUXUS SEMPERVIRENS / GREEN VELVET BOXWOOD SHRUB, 3 GAL. HEMEROCALLIS X 'BLACK-EYED STELLA' / BLACK-EYED STELLA DAYLILY, #1 POT TAG S-1 P-1 RHAMNUS FRANGULA 'RON WILLIAMS' / FINE LINE BUCKTHORN, 1 GAL. S-3 PENNISETUM ALOPECUROIDES 'HAMELN' / DWARF FOUNTAIN GRASS, 1/2 GAL. S-5 MISCANTHUS SINENSIS 'ZEBRINUS' / ZEBRA GRASS, 1 GAL. S-6 BUDDLEIA X 'LO & BEHOLD BLUE CHIP JR.' / LO & BEHOLD 'BLUE CHIP JR.' BUTTERFLY BUSH, 1 GAL. S-4 GLEDITSIA TRIACANTHOS F. INERMIS 'SKYCOLE' SKYLINE THORNLESS HONEYLOCUST 2-1-2" CAL. T-1 PERENNIALS 12/25/21ADDENDUM 1SCALE:1/4" = 1'-0" 4 ELEVATION - MECH ENCLOSURE FRONT SCALE:1/4" = 1'-0" 6 ELEVATION - MECH ENCLOSURE SIDE NEPETA X FAASSENII / JUNIOR WALKER CATMINT, #1 POT S-21 NARROW 'H' CHANNEL SCHD. FRAME SCHEDULED GLAZING4 1/2"2" SCHD. FRAME SCHD. FLOOR CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS SHIMS BACKER ROD & SEALANT2"4 1/2" SCHD. FRAME SCHD. WALL CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS BACKER ROD & SEALANT 4 1/2"2" SCHD. GLAZINGSCHED. FRAME SCHEDULED GLAZING 4 1/2"2"BACKER ROD & SEALANT SCHD. FRAME SCHD. GLAZING 2"4 1/2" CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS SCHD. FRAME SCHD. GLAZING SCHD. DOOR SCHD. GLAZING SCHD. FRAME SCHD. DOOR 1/8" SCHEDULED DOOR FIRST FLOOR 0" 2 A6-1 9'-8" 1'-8"1'-8" SCHED REF DOOR8'-8"7'-0"IGU-1IGU-1 IGU-1IGU-1IGU-1 IGU-1 IGU-1 T T T RUN POWER SUPPLY TO ADA OPERATOR WITHIN SF FRAMING FIRST FLOOR 0" IGU-1 IGU-1 1'-0" 6'-0" 5'-1" EQ EQ T T 2 A6-2 SIM FIRST FLOOR 0"1'-0" 5'-11" 3'-0" IGU-1T 1 A6-3 SIM FIRST FLOOR 0" 5 A6-2 IGU-13'-4"3'-4"3'-0" FIRST FLOOR 0" VG-2 VG-2 T T WF-1 9'-6 1/2" 2'-6" SCHED REF DOOR 2'-0"4'-0"23 A8-2 20 A8-2 RUN POWER SUPPLY TO ADA OPERATOR WITHIN SF FRAMING FIRST FLOOR 0" VG-2 VG-2 VG-2TTT 9'-5" EQ EQ EQ 8'-0"23 A8-2 20 A8-2 FIRST FLOOR 0" VG-2 VG-2TT 7'-7 3/4" SCHED REF DOOR EQ EQ 23 A8-2 20 A8-2 FIRST FLOOR 0" SPG-1 SPG-16'-6"1'-6"6'-7" EQ EQ 23 A8-2 20 A8-2 LOCATE REMOTE TRANSFORMER IN ACCESSIBLE LOCATION ABOVE WINDOW. RUN POWER SUPPLY AT MIDPOINT OF EACH GLASS PANEL WITHIN STOREFRONT FRAMING. 1 A7-1 2 A7-1 FIRST FLOOR 0" VG-2VG-2 WF-1WF-1 10'-6" EQ SCHED REF DOOR EQ T T8'-0"4'-6"1'-6"23 A8-2 20 A8-2 FIRST FLOOR 0" VG-2T8'-0"6'-2 1/2" SCHED REF DOOR 23 A8-2 20 A8-2 BASEMENT -10'-4" 12'-6" EQ SCHED REF DOOR EQ7'-4"2'-0"3'-4"VG-2 VG-2TT 23 A8-2 20 A8-2 WF-1 WF-1 BASEMENT -10'-4" 6'-4"7'-4"23 A8-2 BASEMENT -10'-4" 1 A6-3 3'-0"3'-0"5'-0"IGU-1 BACKER ROD & SEALANT SCHD. FRAME SCHD. GLAZING CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS 2"4 1/2" U.N.O. SCHED. FRAME SCHEDULED GLAZING 2"4 1/2" U.N.O.SCHD. FRAME SCHD. WALL CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS BACKER ROD & SEALANT SCHD. GLAZING 2"4 1/2" U.N.O.SCHD. FRAME SCHD. FLOOR CAULK WITH COLOR-MATCHED CAULK OR PROVIDE MATCHING ALUM COVER STRIP TO HIDE SHIMS BACKER ROD & SEALANT SILL PAN SET IN SEALANT, ENSURE POSITIVE DRAINAGE 2"4 1/2" U.N.O. SCHD. FRAME SCHEDULED GLAZING4 1/2" U.N.O.2" FIRST FLOOR 0" 1'-1"2'-6"4'-0"WF-1 APPLY FILM OVER EXISTING WINDOW FIRST FLOOR 0" IGU-13'-5"3'-6"3'-0" 1 A6-3 SIM FIRST FLOOR 0" 4'-6 5/8"8'-0"SCHED REF DOOR VG-1 T 23 A8-2 20 A8-2 FIRST FLOOR 0" VG-1 VG-1 7'-0" EQ EQ 8'-0"23 A8-2 20 A8-2 T T SCHED REF DOOR FIRST FLOOR 0" VG-1 T 20 A8-2 23 A8-2 4'-6 5/8"8'-0"SCHED REF DOOR tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO.REVISIONSDRAWING NAME A8-2 FRAME ELEVATIONS & DETAILS KG 20128 02/12/2021 BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:6" = 1'-0" 6 FRAMELESS CONNECTION SCALE:3" = 1'-0" 19 SF VERTICAL SCALE:3" = 1'-0" 20 SF SILL SCALE:3" = 1'-0" 21 SF JAMB SCALE:3" = 1'-0" 22 SF HORIZONTAL SCALE:3" = 1'-0" 23 SF HEAD SCALE:3" = 1'-0"24 ALUM. DOOR JAMB - SIDELITE SCALE:3" = 1'-0"25 ALUM. DOOR HEAD - TRANSOM SCALE:3" = 1'-0"26 ALUM. DOOR CENTER STILE ALUMINUM DOOR DETAILS EXTERIOR STOREFRONT DETAILS MISC. GLAZING DETAILS INTERIOR STOREFRONT DETAILS AF-1AF-2AF-3AF-4 AF-11AF-12AF-13AF-14AF-15AF-16 AF-17AF-18 AF-5 GLAZING SCHEDULE IGU-1 1", LOW-E INSULATED GLAZING. GUARDIAN SNX 51/23 ON CLEAR. VLT 51%, SHGC .23 SPG-1 7/16" CLEAR LAMINATED SWITCHABLE PRIVACY GLASS. REFERENCE SPEC SECTION 08 88 36.16 VG-1 1/4", VISION GLASS VG-2 1/2", VISION GLASS WF-1 WINDOW FILM, SOLYX SX-C333 OVER SCHEDULED GLASS. WF-2 WINDOW FILM, SOLYX SXJ-0547 OVER SCHEDULED GLASS. SCALE:3" = 1'-0"1 EXT SF HEAD SCALE:3" = 1'-0"2 EXT SF HORIZONTAL SCALE:3" = 1'-0"4 EXT SF JAMB SCALE:3" = 1'-0"5 EXT SF SILL SCALE:3" = 1'-0"7 EXT SF VERTICAL ALUMINUM-FRAMED EXTERIOR STOREFRONT, 2"x4-1/2" ALUMINUM-FRAMED INTERIOR STOREFRONT, 2"x4-1/2" ETR-1 EXISTING TO REMAIN 12/25/21ADDENDUM 1AF-6 COLOR 1 COLOR 2 AF-19AF-20AF-211 ALL OCCUPANCY SENSOR TO BE SET TO TURN OFF LIGHTS LESS THAN 30 MINUTES AFTER ANYBODY LEAVES THE ROOM. 1 NL, NIGHT LIGHTS TO BE ON NON SWITCHING OPERATION ALL NIGHT LIGHTS NL, TO HAVE EMERGENCY BATTERY BACK UP 90 MINUTE. UL 924 DEVICE REQUIRED AT LED FIXTURES WHEN USED AS EM & ALSO USED AS DIMMABLE FIXTURES. 2 3 4 L I G H T I N G N O T E S NIGHT LIGHTS NLA, NLB, TO BE CONTROLLED THRU TIME CLOCK. 5 6 SEE ELECTRICAL LEGEND FOR OCCUPANCY SENSORS, POWER PACKS TYPES. EXACT LOCATION OF DRIVE LANE OPEN CLOSE SIGNS & CONTROLS BY OWNER. 7 NEW OCCUPANCY SENSOR THIS AREA. TIE INTO EXTG. LIGHTING CIRCUITS. ADD LIGHTING CIRCUITS AS NEEDED. 8 TIE NEW LIGHTING INTO EXTG. SWITCHING THIS ROOM. 9 REMOVE EXTG. SWITCHING FOR CANOPY. COORDINATE IF EXTG. CONDUIT CAN BE REUSED. REUSE EXTG. CIRCUITING AND WIRING IF POSSIBLE. ADD CIRCUITS IN THE EXTG. ELEC. PANELS AS NEEDED. EC RESPONSIBLE FOR ELEC. LOADS AND WIRING SIZING AND ROUTES OF CONDUIT OF WIRING FOR NEW OR EXTG. ELECTRICAL ITEMS. 10 11 JBL BRAND SPEAKER IN CEILING. PLAYLIST TO BE CONTROLLED BY IPAD. VOLUME BY CONTROL ON THE WALL. HARDWIRED TO VOLUME CONTROL. SOUND SYSTEM REQUIREMENTS 1, SONOS AMP. MFR # AMPG1US1BLK, Attach desired speakers Your speakers’power rating should be at least 125W for 8 ohm speakers, and at least 200W for 4 ohm speakers. Do not connect speakers rated at less than 4 ohm. Note:Amp can drive speakers with nominal impedance above 4 ohms. Two pairs of 8 ohm speakers wired in parallel are also supported. Don’t wire your speakers in series because it will result in poor sound quality. Remove the cap from the banana plug to reveal the connection hole. Insert the stripped end of the speaker wire into the hole, then return the cap to the banana plug to secure the connection. 2, New-construction Bracket for Director 6.5" and 8" and Thinfit In-ceiling speakers 3, JBL Control® 26CT 6-1/2" commercial in-ceiling speaker 4, 3 Episode® Electronics 100 Watt Rotary Volume Control (Each | White & Light Almond) 5, 3 14/4 Audio wire up to 100' run 12 OCCUPANCY SENSOR OVERIDE WALL SWITCH. 13 SEE ELECTRICAL RISER DIAGRAM FOR CONTROL OF EXERIOR FIXTURES. THE EXTG. SITE LIGHTS TO BE CONTROLLED BY THE EXTG. TIMING DEVICE. LIGHT FIXTURE SCHEDULE GENERAL NOTES: A. ALL LIGHT FIXTURES SHALL BE UL LISTED. B. REFERENCE SPECIFICATION SECTION FOR ADDITIONAL REQUIREMENTS. C. ALL BIDDERS, INCLUDING THOSE SPECIFIED AND MANUFACTURERS LISTED AS “EQUAL”, SHALL SUBMIT PRODUCT CUTSHEETS TO THE ENGINEER TEN (10) DAYS PRIOR TO BID FOR FINAL WRITTEN APPROVAL. “EQUAL” FIXTURES SHALL BE OF EQUAL OR BETTER QUALITY AND PERFORMANCE TO THE SPECIFIED FIXTURE. BURDEN OF PROOF SHALL BE ON THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE WITH CORD AND PLUG AT THE REQUEST OF THE ENGINEER. D. MANUFACTURERS/VENDORS WISHING TO BID SUBSTITUTE FIXTURES OTHER THAN THOSE LISTED ON THE LIGHT FIXTURE SCHEDULE, SHALL SUBMIT CUTSHEETS AS REQUIRED PER SPECIFICATION SECTION 16500 AND AT THE REQUEST OF THE ENGINEER PROVIDE FACTORY POINT-BY-POINT CALCULATIONS USING AGI32 AND PROVIDE ELECTRONIC .AGI FILE TEN (10) DAYS PRIOR TO BID FOR WRITTEN APPROVAL. BURDEN OF PROOF SHALL BE ON THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE OF EACH SUBSTITUTE FIXTURE WITH CORD AND PLUG AT THE REQUEST OF THE ENGINEER. E. CONTRACTOR SHALL PROVIDE UNSWITCHED CONDUCTORS TO ALL FIXTURES WITH EMERGENCY LED BATTERY PACKS AS REQUIRED. F. CONTRACTOR SHALL FOCUS, AIM AND ADJUST LIGHT FIXTURES UNDER THE SUPERVISION AND DIRECTION OF THE ENGINEER AND ARCHITECT. ALLOW LABOR FOR FINAL FOCUS AND ADJUSTMENTS AFTER DARK. LIFTS AND SCAFFOLDING SHALL BE AVAILABLE. G. CONFIRM ALL FINISHES AND MOUNTING HEIGHTS WITH ARCHITECT DURING SHOP DRAWING REVIEW. PROVIDE CUSTOM, FACTORY CUT STEM LENGTHS AS REQUIRED. H. REFER TO DRAWINGS FOR MOUNTING REQUIREMENTS, NUMBER OF FACES AND ARROWS (CHEVRONS) FOR ALL EXIT SIGNS. COORDINATE WITH ARCHITECT’S REFLECTED CEILING PLANS. I. CONTRACTOR SHALL VERIFY CEILING TYPES PRIOR TO ORDERING FIXTURE AND PROVIDE FIXTURES APPROPRIATE TO THE ACTUAL CONDITION. THIS IS TO INCLUDE SPECIFIC TYPE OF LAY-IN CEILING GRID. J. ALL FIXTURES SHALL HAVE INTERNAL FAST-BLOW FUSING. K. ALL LAY-IN FIXTURES SHALL BE PROVIDED WITH SCREW ON HOLD DOWN CLIPS, AND MAX. 6’-0” LONG ½” FLEXIBLE CONDUIT WHIPS WITH TWO #12 AND #12 GROUND. L. COORDINATE EXIT / EM MOUNTING HEIGHT AT LOCATION SHOWN M. FOR LIGHTING IN EXPOSED STRUCTURE AREAS, EC SHALL PROVIDE UNI-STRUT OR SIMILAR HARDWARE FOR FIXTURE INSTALLATION BETWEEN JOISTS. N. ALL CEILING OR HIGH WALL MOUNTED OCCUPANCY VACANCY, OR DAY LIGHT HARVESTING SENSORS SHALL HAVE A WALL MOUNTED OVERIDE SWITCH IN THE LOCATION SHOWN. LAY-IN CEILING LAY-IN CEILING FLEXIBLE CONDUIT W/#12 WIRE (6' MAX.) LAY-IN CEILING JUNCTION BOX LAY-IN CEILING 12 GAUGE HANGER WIRE OR CHAIN FOR FIXTURE SUPPORT CONNECTED TO STRUCTURE ABOVE SEISMIC CLIP 1 1 D 1 D 2 2 2 OCC PP 3 3 NL D 4 44 5 5 D 5 D6 6 NL NL NL 7 OCW 7 OCC PP NL 8 8 8 3 8 D 9 9 9 NL OCC4 OCCPP 3 OCC PP3 3 3 3 4 4 4 4 333 4 D 4 D 3 5 OCW 5 6 6 NL NL 8 8 6 OC 13 OC 13 OC 13 7 OCW 7 NL NLANLANLA NLB NLB NLB NLB NLB NLB EXIT EXIT7 7 7 7 7 7 7 7 8 9 SP V SP SP SP V V 11 1111 11 SP11 V R3 R3 P3 S1 S1 D1 D1 R1 R1 P1 P1 R3 R3 R1R2 D1 D1 D1 D1 D1 D1D1 3M1 R1R1R1 R1R1 R3 R3 R1 R1 R3 R3 R3 R3 D1 D1 D1 D1 D1 D1 D13 R2 R2 R2 R2 R2 R2 H-24 H-24 H-24 H-24 H-24 H-24NLCNLCNLCNLCNLC NLC S1 S1 S1 NLA NLA NLA W1 NLA S1 S1 S1 S1 6 D D D Type MFG Part D1 Intense Lighting SS4G4DS-L4-358 ICS430-HZ-SF I200 M1 Columbia Lighting MPS4-35ML-CW-EDU / CSHC P1 The Original Cast Lighting GB1-XX-04-FS-XX-LED1-35K-UNV-XXDM1 P1- CLUSTER The Original Cast Lighting GB1-P3CA-06-FS-XX-LED1-35K-UNVXX-DM1 P3 The Original Cast Lighting GL1-C1NB-24-MW-XX-LED2-35K-UNVDM1 R1 Axis Lighting B6RLED-800-80-35-RG-4'-W-UNV-DP-1-TXX R2 Axis Lighting B6RLED-800-80-35-RG-2'-W-UNV-DP-1-TXX R3 Axis Lighting B6RLED-800-80-35-RG-6'-W-UNV-DP-1-TXX S1 Scott Architectural Lighting S3A15-L05A-935K-XX-XX U1 Axis Lighting BCUC-RUN-XX-80-W-UNV-XX-XX W1 Intense Lighting GD2WS EXIT Beghelli OL2-HT-LR-1-C-CR INTERIOR LIGHT FIXTURE SCHEDULE F2 Hubbell Lighting Outdoor RFL3-90L-40-XK7-W-UNV-K-XX H-24 Finelite HP-4 WL R-24'-H-8XX-F-XXV-SC-VF R2 Intense Lighting SS4G4DS-L3-XX8 / ICS432-HZ-SF / I100 S1 Stone Lighting WO877-XX-LED V4 Beacon Products VP-S/36L-80/XK7/4F/UNV/A/BLT Item Note: INSTALLED ON EXISTING POLE. MATCH ADJACENT FIXTURES IN DEVELOPMENT. W1 Performance iN Lighting SHIELD+ 2, TYPE III, 37W EXTERIOR LIGHT FIXTURE SCHEDULE MFG Part ABL -Lithonia Lighting LDN6SQ 35/20 LS6AR LD MVOLT GZ10 ABL -Lithonia Lighting CDS L48 MVOLT DM 35K 80CRI WH HC36 EUREKA 4029-UAC LED.4 35 VOLT DV C XX RC SC SAA FRO EUREKA 4427-3 UAC LED.4 35 VOLT DV C XX CHR FRO SAA ABL-Mark Lighting FCL CIR 20DIA FLP XX 80CRI 35K 400LMF MIN1 VOLT ZT ABL-Mark Lighting SL6L LOP 4FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT ABL-Mark Lighting SL6L LOP 2FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT ABL-Mark Lighting SL6L LOP 6FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT EUREKA 3409 LED.4 35 DV FINISH CFR ABL -Lithonia Lighting RAZ XIN 30K 90CRI ABL -Juno Lighting Group INIT3SQ BASIS OF DESIGN FIXTURES ACCEPTABLE ALTERNATE FIXTURES BASIS OF DESIGN FIXTURES ACCEPTABLE ALTERNATE FIXTURES ABL -Lithonia Lighting TFX1 LED 40K MVOLT THK DDBXD M6 Pinnacle Architectural Lighting EV3 WET X35 2' IND FLF U OL2 10 W ABL -Lithonia Lighting LDN4SQ XX/15 LS4AR LD MVOLT GZ10 WL Kichler Lighting 49279AZTLED ABL-Lithonia Lighting WDGE3 LED SRM tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO.REVISIONSDRAWING NAME E2-1 ELECTRICAL LIGHTING PLAN KRM 20128 02/12/2021 BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:1/4" = 1'-0"3 LIGHT SUPPORT DETAIL SCALE:1/4" = 1'-0"1 FIRST FLOOR REFLECTED CEILING PLAN 12/25/21ADDENDUM 11