HomeMy WebLinkAbout20210225_Addendum 1
TTV
S
AC
AC
EH
EH
TR
SCV
TTV
S
AC
AC
EH
EH
TR
SCV
3
AS1-1
2
AS1-1
MILL AND FILL ASPHALT
PARKING LOT AND
RESTRIPE
NEW PLANTINGS
PROPERTY LINE
LAWN
LAWNLAWN
S-1
S-4
P-1
S-5
S-5
S-1
S-3
P-1
S-6
T-1
S-6
MULCH PLANTING BED
STONE PLANTING BED
P-1
S-2 S-2
S-5
S-1
CONCRETE PAVER ENTRYWAY
P-1
S-5
126th STREET
GRAY ROADBROOKSHIRE PLAZA DEVELOPMENT
BUFFERYARD
S-6
S-6
P-1 10'-0"MECHANICAL
ENCLOSURE
TRASH
ENCLOSURE
1
1
3
3
3
3
4
S-5
FLAG POLE, 25' TALL
WITH BASE LIGHTING,
CFCI
2 5'-0" 5'-0"6'-0"12'-0"
6'-0" 6'-0"
PAINTED MARKINGS, TYP
PAINTED
MARKINGS, TYP
4
AS1-1
6
AS1-1
7'-6"10'-0"6'-0"3'-8" 3'-8"
EXISTING GAS LINE, VERIFY LOCATION
AND PROTECT. ADJUST LOCATION OF
ENCLOSURE AS NEEDED.
REMOVE EXISTING PLANTINGS AND
GROUND COVER COMPLETELY 1
REMOVE EXISTING PLANTINGS AND
GROUND COVER COMPLETELY
1
REMOVE EXISTING PLANTINGS AND
GROUND COVER COMPLETELY 1 6'-3"> 5"SOLID SWING GATE WITH
CANE BOLT
ALUMINUM SLAT INFILL PANEL
10"D X 2'-6" CONCRETE
FOOTINGS
4"X4" ALUMINUM POST
ALUMINUM TRASH
ENCLOSURE SYSTEM, REF
SPEC 05 50 00
4'-0" 6'-0"
ALUMINUM SLAT INFILL PANEL
10"D X 2'-6" CONCRETE
FOOTINGS
4"X4" ALUMINUM POST
ALUMINUM TRASH
ENCLOSURE SYSTEM, REF
SPEC 05 50 00
6'-0" 6'-0"6'-3"10"D X 2'-6" CONCRETE
FOOTINGS
4"X4" ALUMINUM POST
ALUMINUM TRASH
ENCLOSURE SYSTEM, REF
SPEC 05 50 00
SOLID SWING GATE WITH
CANE BOLT
ALUMINUM SLAT INFILL PANEL
6'-3"4'-0" 6'-0"
ALUMINUM SLAT INFILL PANEL
10"D X 2'-6" CONCRETE
FOOTINGS
4"X4" ALUMINUM POST
ALUMINUM TRASH
ENCLOSURE SYSTEM, REF
SPEC 05 50 00
6'-3"3'-8" 3'-8"
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.REVISIONSDRAWING NAME
AS1-1
ARCHITECTURAL
SITE PLAN
Author
20128
02/12/2021
BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:1" = 10'-0"
1 LANDSCAPE/SIGNAGE PLAN
EXTERIOR SIGNAGE SCHEDULE - CFCI
1 ILLUMINATED BUILDING-MOUNTED SIGNAGE
2 MAXIMUM HEIGHT SIGNAGE, LESS THAN 3 SF
3 DIRECTIONAL SIGNAGE LESS THAN 3SF
4 PARKING SIGNAGE LESS THAN 3SF
SCALE:1/4" = 1'-0"2 ELEVATION - TRASH ENCLOSURE FRONT
SCALE:1/4" = 1'-0"3 ELEVATION - TRASH ENCLOSURE SIDE
PLANTING MATRIX
TREES
SHRUBS
BUXUS SEMPERVIRENS / GREEN VELVET BOXWOOD SHRUB, 3 GAL.
HEMEROCALLIS X 'BLACK-EYED STELLA' /
BLACK-EYED STELLA DAYLILY, #1 POT
TAG
S-1
P-1
RHAMNUS FRANGULA 'RON WILLIAMS' / FINE LINE BUCKTHORN, 1 GAL. S-3
PENNISETUM ALOPECUROIDES 'HAMELN' / DWARF FOUNTAIN GRASS, 1/2 GAL. S-5
MISCANTHUS SINENSIS 'ZEBRINUS' / ZEBRA GRASS, 1 GAL. S-6
BUDDLEIA X 'LO & BEHOLD BLUE CHIP JR.' /
LO & BEHOLD 'BLUE CHIP JR.' BUTTERFLY BUSH, 1 GAL.
S-4
GLEDITSIA TRIACANTHOS F. INERMIS 'SKYCOLE'
SKYLINE THORNLESS HONEYLOCUST
2-1-2" CAL.
T-1
PERENNIALS 12/25/21ADDENDUM 1SCALE:1/4" = 1'-0"
4 ELEVATION - MECH ENCLOSURE FRONT
SCALE:1/4" = 1'-0"
6 ELEVATION - MECH ENCLOSURE SIDE
NEPETA X FAASSENII / JUNIOR WALKER CATMINT, #1 POT S-21
NARROW 'H' CHANNEL
SCHD. FRAME
SCHEDULED
GLAZING4 1/2"2"
SCHD. FRAME
SCHD. FLOOR
CAULK WITH
COLOR-MATCHED
CAULK OR PROVIDE
MATCHING ALUM
COVER STRIP TO
HIDE SHIMS
SHIMS
BACKER ROD & SEALANT2"4 1/2"
SCHD. FRAME
SCHD. WALL
CAULK WITH
COLOR-MATCHED
CAULK OR PROVIDE
MATCHING ALUM
COVER STRIP TO
HIDE SHIMS
BACKER ROD &
SEALANT 4 1/2"2"
SCHD. GLAZINGSCHED. FRAME
SCHEDULED
GLAZING
4 1/2"2"BACKER ROD &
SEALANT
SCHD. FRAME
SCHD. GLAZING 2"4 1/2"
CAULK WITH COLOR-MATCHED CAULK
OR PROVIDE MATCHING ALUM COVER
STRIP TO HIDE SHIMS
SCHD. FRAME
SCHD. GLAZING
SCHD. DOOR
SCHD. GLAZING
SCHD. FRAME
SCHD. DOOR
1/8"
SCHEDULED DOOR
FIRST FLOOR
0"
2
A6-1
9'-8"
1'-8"1'-8"
SCHED
REF DOOR8'-8"7'-0"IGU-1IGU-1
IGU-1IGU-1IGU-1
IGU-1
IGU-1
T T T
RUN POWER SUPPLY
TO ADA OPERATOR
WITHIN SF FRAMING
FIRST FLOOR
0"
IGU-1 IGU-1
1'-0" 6'-0"
5'-1"
EQ EQ
T T
2
A6-2
SIM
FIRST FLOOR
0"1'-0" 5'-11"
3'-0"
IGU-1T
1
A6-3
SIM
FIRST FLOOR
0"
5
A6-2
IGU-13'-4"3'-4"3'-0"
FIRST FLOOR
0"
VG-2 VG-2
T T
WF-1
9'-6 1/2"
2'-6"
SCHED
REF DOOR 2'-0"4'-0"23
A8-2
20
A8-2
RUN POWER SUPPLY
TO ADA OPERATOR
WITHIN SF FRAMING
FIRST FLOOR
0"
VG-2 VG-2 VG-2TTT
9'-5"
EQ EQ EQ
8'-0"23
A8-2
20
A8-2
FIRST FLOOR
0"
VG-2 VG-2TT
7'-7 3/4"
SCHED
REF DOOR
EQ EQ
23
A8-2
20
A8-2
FIRST FLOOR
0"
SPG-1 SPG-16'-6"1'-6"6'-7"
EQ EQ
23
A8-2
20
A8-2
LOCATE REMOTE TRANSFORMER
IN ACCESSIBLE LOCATION ABOVE
WINDOW. RUN POWER SUPPLY AT
MIDPOINT OF EACH GLASS PANEL
WITHIN STOREFRONT FRAMING.
1
A7-1
2
A7-1
FIRST FLOOR
0"
VG-2VG-2
WF-1WF-1
10'-6"
EQ
SCHED
REF DOOR EQ
T T8'-0"4'-6"1'-6"23
A8-2
20
A8-2
FIRST FLOOR
0"
VG-2T8'-0"6'-2 1/2"
SCHED
REF DOOR
23
A8-2
20
A8-2
BASEMENT
-10'-4"
12'-6"
EQ
SCHED
REF DOOR EQ7'-4"2'-0"3'-4"VG-2 VG-2TT
23
A8-2
20
A8-2
WF-1
WF-1
BASEMENT
-10'-4"
6'-4"7'-4"23
A8-2
BASEMENT
-10'-4"
1
A6-3
3'-0"3'-0"5'-0"IGU-1
BACKER ROD &
SEALANT
SCHD. FRAME
SCHD. GLAZING
CAULK WITH COLOR-MATCHED CAULK
OR PROVIDE MATCHING ALUM COVER
STRIP TO HIDE SHIMS
2"4 1/2" U.N.O.
SCHED. FRAME
SCHEDULED
GLAZING
2"4 1/2" U.N.O.SCHD. FRAME
SCHD. WALL
CAULK WITH
COLOR-MATCHED
CAULK OR PROVIDE
MATCHING ALUM
COVER STRIP TO
HIDE SHIMS
BACKER ROD &
SEALANT
SCHD. GLAZING
2"4 1/2" U.N.O.SCHD. FRAME
SCHD. FLOOR
CAULK WITH
COLOR-MATCHED
CAULK OR PROVIDE
MATCHING ALUM
COVER STRIP TO
HIDE SHIMS
BACKER ROD & SEALANT
SILL PAN SET IN SEALANT,
ENSURE POSITIVE DRAINAGE
2"4 1/2" U.N.O.
SCHD. FRAME
SCHEDULED
GLAZING4 1/2" U.N.O.2"
FIRST FLOOR
0"
1'-1"2'-6"4'-0"WF-1
APPLY FILM OVER
EXISTING WINDOW
FIRST FLOOR
0"
IGU-13'-5"3'-6"3'-0"
1
A6-3
SIM
FIRST FLOOR
0"
4'-6 5/8"8'-0"SCHED
REF DOOR
VG-1
T
23
A8-2
20
A8-2
FIRST FLOOR
0"
VG-1 VG-1
7'-0"
EQ EQ
8'-0"23
A8-2
20
A8-2
T T
SCHED
REF DOOR
FIRST FLOOR
0"
VG-1
T
20
A8-2
23
A8-2
4'-6 5/8"8'-0"SCHED
REF DOOR
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.REVISIONSDRAWING NAME
A8-2
FRAME ELEVATIONS
& DETAILS
KG
20128
02/12/2021
BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:6" = 1'-0"
6 FRAMELESS CONNECTION
SCALE:3" = 1'-0"
19 SF VERTICAL
SCALE:3" = 1'-0"
20 SF SILL
SCALE:3" = 1'-0"
21 SF JAMB
SCALE:3" = 1'-0"
22 SF HORIZONTAL
SCALE:3" = 1'-0"
23 SF HEAD
SCALE:3" = 1'-0"24 ALUM. DOOR JAMB - SIDELITE
SCALE:3" = 1'-0"25 ALUM. DOOR HEAD - TRANSOM
SCALE:3" = 1'-0"26 ALUM. DOOR CENTER STILE
ALUMINUM DOOR DETAILS EXTERIOR STOREFRONT DETAILS
MISC. GLAZING DETAILS INTERIOR STOREFRONT DETAILS
AF-1AF-2AF-3AF-4
AF-11AF-12AF-13AF-14AF-15AF-16
AF-17AF-18
AF-5
GLAZING SCHEDULE
IGU-1 1", LOW-E INSULATED GLAZING. GUARDIAN SNX 51/23 ON
CLEAR. VLT 51%, SHGC .23
SPG-1 7/16" CLEAR LAMINATED SWITCHABLE PRIVACY GLASS.
REFERENCE SPEC SECTION 08 88 36.16
VG-1 1/4", VISION GLASS
VG-2 1/2", VISION GLASS
WF-1 WINDOW FILM, SOLYX SX-C333 OVER SCHEDULED GLASS.
WF-2 WINDOW FILM, SOLYX SXJ-0547 OVER SCHEDULED GLASS.
SCALE:3" = 1'-0"1 EXT SF HEAD
SCALE:3" = 1'-0"2 EXT SF HORIZONTAL
SCALE:3" = 1'-0"4 EXT SF JAMB
SCALE:3" = 1'-0"5 EXT SF SILL
SCALE:3" = 1'-0"7 EXT SF VERTICAL
ALUMINUM-FRAMED EXTERIOR STOREFRONT, 2"x4-1/2"
ALUMINUM-FRAMED INTERIOR STOREFRONT, 2"x4-1/2"
ETR-1
EXISTING TO REMAIN
12/25/21ADDENDUM 1AF-6
COLOR 1
COLOR 2
AF-19AF-20AF-211
ALL OCCUPANCY SENSOR TO BE SET TO TURN
OFF LIGHTS LESS THAN 30 MINUTES AFTER
ANYBODY LEAVES THE ROOM.
1
NL, NIGHT LIGHTS TO BE ON NON SWITCHING OPERATION
ALL NIGHT LIGHTS NL, TO HAVE EMERGENCY BATTERY
BACK UP 90 MINUTE.
UL 924 DEVICE REQUIRED AT LED FIXTURES WHEN
USED AS EM & ALSO USED AS DIMMABLE FIXTURES.
2
3
4
L I G H T I N G N O T E S
NIGHT LIGHTS NLA, NLB, TO BE CONTROLLED THRU TIME
CLOCK.
5
6
SEE ELECTRICAL LEGEND FOR OCCUPANCY SENSORS,
POWER PACKS TYPES.
EXACT LOCATION OF DRIVE LANE OPEN CLOSE SIGNS
& CONTROLS BY OWNER.
7 NEW OCCUPANCY SENSOR THIS AREA. TIE INTO EXTG.
LIGHTING CIRCUITS. ADD LIGHTING CIRCUITS AS NEEDED.
8 TIE NEW LIGHTING INTO EXTG. SWITCHING THIS ROOM.
9 REMOVE EXTG. SWITCHING FOR CANOPY. COORDINATE
IF EXTG. CONDUIT CAN BE REUSED.
REUSE EXTG. CIRCUITING AND WIRING IF POSSIBLE.
ADD CIRCUITS IN THE EXTG. ELEC. PANELS AS NEEDED.
EC RESPONSIBLE FOR ELEC. LOADS AND WIRING SIZING
AND ROUTES OF CONDUIT OF WIRING FOR NEW OR EXTG.
ELECTRICAL ITEMS.
10
11 JBL BRAND SPEAKER IN CEILING. PLAYLIST TO BE CONTROLLED
BY IPAD. VOLUME BY CONTROL ON THE WALL. HARDWIRED TO
VOLUME CONTROL.
SOUND SYSTEM REQUIREMENTS
1, SONOS AMP. MFR # AMPG1US1BLK, Attach desired speakers
Your speakers’power rating should be at least 125W for 8 ohm
speakers, and at least 200W for 4 ohm speakers. Do not connect
speakers rated at less than 4 ohm.
Note:Amp can drive speakers with nominal impedance above 4 ohms.
Two pairs of 8 ohm speakers wired in parallel are also supported. Don’t
wire your speakers in series because it will result in poor sound quality.
Remove the cap from the banana plug to reveal the connection hole.
Insert the stripped end of the speaker wire into the hole, then return the
cap to the banana plug to secure the connection.
2, New-construction Bracket for Director 6.5" and
8" and Thinfit In-ceiling speakers
3, JBL Control® 26CT 6-1/2" commercial in-ceiling speaker
4, 3 Episode® Electronics 100 Watt Rotary Volume
Control (Each | White & Light Almond)
5, 3 14/4 Audio wire up to 100' run
12 OCCUPANCY SENSOR OVERIDE WALL SWITCH.
13 SEE ELECTRICAL RISER DIAGRAM FOR CONTROL OF EXERIOR
FIXTURES. THE EXTG. SITE LIGHTS TO BE CONTROLLED BY THE
EXTG. TIMING DEVICE.
LIGHT FIXTURE SCHEDULE GENERAL NOTES:
A. ALL LIGHT FIXTURES SHALL BE UL LISTED.
B. REFERENCE SPECIFICATION SECTION FOR ADDITIONAL REQUIREMENTS.
C. ALL BIDDERS, INCLUDING THOSE SPECIFIED AND MANUFACTURERS LISTED AS “EQUAL”, SHALL SUBMIT
PRODUCT CUTSHEETS TO THE ENGINEER TEN (10) DAYS PRIOR TO BID FOR FINAL WRITTEN APPROVAL. “EQUAL”
FIXTURES SHALL BE OF EQUAL OR BETTER QUALITY AND PERFORMANCE TO THE SPECIFIED FIXTURE. BURDEN OF
PROOF SHALL BE ON THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE WITH CORD AND
PLUG AT THE REQUEST OF THE ENGINEER.
D. MANUFACTURERS/VENDORS WISHING TO BID SUBSTITUTE FIXTURES OTHER THAN THOSE LISTED ON THE
LIGHT FIXTURE SCHEDULE, SHALL SUBMIT CUTSHEETS AS REQUIRED PER SPECIFICATION SECTION 16500 AND AT
THE REQUEST OF THE ENGINEER PROVIDE FACTORY POINT-BY-POINT CALCULATIONS USING AGI32 AND PROVIDE
ELECTRONIC .AGI FILE TEN (10) DAYS PRIOR TO BID FOR WRITTEN APPROVAL. BURDEN OF PROOF SHALL BE ON
THE MANUFACTURER AND SHALL PROVIDE WORKING 120 VOLT SAMPLE OF EACH SUBSTITUTE FIXTURE WITH CORD
AND PLUG AT THE REQUEST OF THE ENGINEER.
E. CONTRACTOR SHALL PROVIDE UNSWITCHED CONDUCTORS TO ALL FIXTURES WITH EMERGENCY LED BATTERY
PACKS AS REQUIRED.
F. CONTRACTOR SHALL FOCUS, AIM AND ADJUST LIGHT FIXTURES UNDER THE SUPERVISION AND DIRECTION OF
THE ENGINEER AND ARCHITECT. ALLOW LABOR FOR FINAL FOCUS AND ADJUSTMENTS AFTER DARK. LIFTS AND
SCAFFOLDING SHALL BE AVAILABLE.
G. CONFIRM ALL FINISHES AND MOUNTING HEIGHTS WITH ARCHITECT DURING SHOP DRAWING REVIEW. PROVIDE
CUSTOM, FACTORY CUT STEM LENGTHS AS REQUIRED.
H. REFER TO DRAWINGS FOR MOUNTING REQUIREMENTS, NUMBER OF FACES AND ARROWS (CHEVRONS) FOR ALL
EXIT SIGNS. COORDINATE WITH ARCHITECT’S REFLECTED CEILING PLANS.
I. CONTRACTOR SHALL VERIFY CEILING TYPES PRIOR TO ORDERING FIXTURE AND PROVIDE FIXTURES
APPROPRIATE TO THE ACTUAL CONDITION. THIS IS TO INCLUDE SPECIFIC TYPE OF LAY-IN CEILING GRID.
J. ALL FIXTURES SHALL HAVE INTERNAL FAST-BLOW FUSING.
K. ALL LAY-IN FIXTURES SHALL BE PROVIDED WITH SCREW ON HOLD DOWN CLIPS, AND MAX. 6’-0” LONG ½”
FLEXIBLE CONDUIT WHIPS WITH TWO #12 AND #12 GROUND.
L. COORDINATE EXIT / EM MOUNTING HEIGHT AT LOCATION SHOWN
M. FOR LIGHTING IN EXPOSED STRUCTURE AREAS, EC SHALL PROVIDE UNI-STRUT OR SIMILAR HARDWARE FOR FIXTURE
INSTALLATION BETWEEN JOISTS.
N. ALL CEILING OR HIGH WALL MOUNTED OCCUPANCY VACANCY, OR DAY LIGHT HARVESTING SENSORS SHALL HAVE A WALL
MOUNTED OVERIDE SWITCH IN THE LOCATION SHOWN.
LAY-IN CEILING
LAY-IN CEILING
FLEXIBLE CONDUIT
W/#12 WIRE (6' MAX.)
LAY-IN CEILING
JUNCTION BOX
LAY-IN CEILING
12 GAUGE HANGER WIRE OR CHAIN FOR FIXTURE
SUPPORT CONNECTED TO STRUCTURE ABOVE
SEISMIC
CLIP
1 1
D 1
D 2
2
2
OCC
PP
3
3
NL
D 4
44
5
5
D 5
D6
6 NL NL
NL
7
OCW
7
OCC
PP
NL
8
8 8
3
8
D 9
9 9
NL
OCC4
OCCPP
3
OCC
PP3
3
3
3
4
4 4 4
333
4
D 4
D 3
5
OCW
5
6
6
NL
NL
8
8
6
OC 13
OC 13
OC 13
7 OCW
7
NL NLANLANLA
NLB NLB
NLB NLB
NLB NLB
EXIT EXIT7
7
7
7
7
7
7
7
8
9
SP
V
SP SP
SP V
V
11
1111
11
SP11
V
R3 R3
P3
S1
S1
D1 D1
R1
R1
P1
P1
R3 R3
R1R2
D1
D1 D1
D1
D1
D1D1
3M1
R1R1R1
R1R1
R3
R3
R1 R1
R3
R3
R3 R3
D1
D1
D1
D1 D1 D1
D13
R2 R2
R2 R2
R2 R2
H-24 H-24 H-24 H-24 H-24 H-24NLCNLCNLCNLCNLC NLC
S1 S1 S1
NLA NLA NLA
W1
NLA
S1 S1 S1 S1
6
D
D
D
Type MFG Part
D1 Intense Lighting SS4G4DS-L4-358 ICS430-HZ-SF I200
M1 Columbia Lighting MPS4-35ML-CW-EDU / CSHC
P1 The Original Cast Lighting GB1-XX-04-FS-XX-LED1-35K-UNV-XXDM1
P1- CLUSTER The Original Cast Lighting GB1-P3CA-06-FS-XX-LED1-35K-UNVXX-DM1
P3 The Original Cast Lighting GL1-C1NB-24-MW-XX-LED2-35K-UNVDM1
R1 Axis Lighting B6RLED-800-80-35-RG-4'-W-UNV-DP-1-TXX
R2 Axis Lighting B6RLED-800-80-35-RG-2'-W-UNV-DP-1-TXX
R3 Axis Lighting B6RLED-800-80-35-RG-6'-W-UNV-DP-1-TXX
S1 Scott Architectural Lighting S3A15-L05A-935K-XX-XX
U1 Axis Lighting BCUC-RUN-XX-80-W-UNV-XX-XX
W1 Intense Lighting GD2WS
EXIT Beghelli OL2-HT-LR-1-C-CR
INTERIOR LIGHT FIXTURE SCHEDULE
F2 Hubbell Lighting Outdoor RFL3-90L-40-XK7-W-UNV-K-XX
H-24 Finelite HP-4 WL R-24'-H-8XX-F-XXV-SC-VF
R2 Intense Lighting SS4G4DS-L3-XX8 / ICS432-HZ-SF / I100
S1 Stone Lighting WO877-XX-LED
V4 Beacon Products VP-S/36L-80/XK7/4F/UNV/A/BLT
Item Note: INSTALLED ON EXISTING POLE. MATCH ADJACENT FIXTURES IN DEVELOPMENT.
W1 Performance iN Lighting SHIELD+ 2, TYPE III, 37W
EXTERIOR LIGHT FIXTURE SCHEDULE
MFG Part
ABL -Lithonia Lighting LDN6SQ 35/20 LS6AR LD MVOLT GZ10
ABL -Lithonia Lighting CDS L48 MVOLT DM 35K 80CRI WH HC36
EUREKA 4029-UAC LED.4 35 VOLT DV C XX RC SC SAA FRO
EUREKA 4427-3 UAC LED.4 35 VOLT DV C XX CHR FRO SAA
ABL-Mark Lighting FCL CIR 20DIA FLP XX 80CRI 35K 400LMF MIN1 VOLT ZT
ABL-Mark Lighting SL6L LOP 4FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT
ABL-Mark Lighting SL6L LOP 2FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT
ABL-Mark Lighting SL6L LOP 6FT RLP XX 80CRI 35K 800LMF MIN1 VOLT ZT
EUREKA 3409 LED.4 35 DV FINISH CFR
ABL -Lithonia Lighting RAZ XIN 30K 90CRI
ABL -Juno Lighting Group INIT3SQ
BASIS OF DESIGN FIXTURES ACCEPTABLE ALTERNATE FIXTURES
BASIS OF DESIGN FIXTURES ACCEPTABLE ALTERNATE FIXTURES
ABL -Lithonia Lighting TFX1 LED 40K MVOLT THK DDBXD M6
Pinnacle Architectural Lighting EV3 WET X35 2' IND FLF U OL2 10 W
ABL -Lithonia Lighting LDN4SQ XX/15 LS4AR LD MVOLT GZ10 WL
Kichler Lighting 49279AZTLED
ABL-Lithonia Lighting WDGE3 LED SRM
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.REVISIONSDRAWING NAME
E2-1
ELECTRICAL
LIGHTING PLAN
KRM
20128
02/12/2021
BID SET4775 E 126th St Carmel IN 46033STATE BANK20128 - CARMEL BRANCHBID SET02/12/2021SCALE:1/4" = 1'-0"3 LIGHT SUPPORT DETAIL
SCALE:1/4" = 1'-0"1 FIRST FLOOR REFLECTED CEILING PLAN 12/25/21ADDENDUM 11