HomeMy WebLinkAboutA1-1UP
DN
3
A4-1
2
A4-1
4
A4-1
MARKET LEADER
114
PARTNER OFFICE
113
PARTNER OFFICE
111
3
A5-1
2 1
B
A
LOBBY
108
TELLER
106
BRANCH MANAGER
110
PARTNER OFFICE
102
RR
103
VAULT
105
VEST.
100
1
A5-1
3
A9-1
2
A6-1
1
A6-1 3
A6-1
CUSTOMER
104A
HALL
112
LOUNGE
115
STAIR
101
LIFT
109
A10-3
5
3
9 A10-3
2 A10-3
A10-3
15
12 14
13
7
8
6
4
15'-5" 1'-0" 9'-4"
10'-2" 14'-8" 11'-0"
15'-5" 9'-8"
10'-5"
12'-4" 1'-6" 6'-7" 1'-4"
5
A6-2
1'-8" 11'-0" 1'-8" 11'-0"
A10-3
10 E5
A10-2 4
3
A10-1
6
105A
102A
107A
106A
101A
108A
100B
100A
106B
110A
104A 103A
1
2
E6
E3 E4 E5
3'-10"
7'-5" 2'-0" 5'-1" 2'-0" 9'-8" 2'-0" 5'-1" 2'-0" 7'-5"
R7
R4
3
3
R6
R9
E9
R8
R5
A10-1
7
A10-1
18
4
100C
E5
A10-3
A10-3
1
A7-1
5
A7-1
4
AF-1 AF-2
AF-2
AF-3
AF-3
AF-3
AF-3 AF-3
AF-3
AF-3 AF-4
AF-15
AF-16
AF-11
AF-12
AF-14
AF-13
1'-2" 1'-10"
4" 4"
5
A7-1
5
SIM
A7-1
4
SIM
E12 E12
ETR-1
23'-2"
2'-10" 2'-10"
typ.
7 8 6
typ.
6
7 8
W2.3
W2.3
C
W2.3
W2.3
W2.3
W2.3
A7-1
3
W2.3
W2.3
E1
E2
2
A6-2
A10-1 21
1'-0" 10'-0"
14'-2 3/4"
1
1'-3 1/2"
5"
A9-1
1
W2.6
D
W2.6
D
9
7'-3" 4'-6" 2'-0"
10
11
11
114A
113A
111A
7
7
7 7
E9
5
A4-1
4
A6-1
1
A6-2
3
A6-3
5
A6-3
23'-10 1/4"
1
A6-3
2
A6-3
W2.3
A7-1
1
A7-1
2
7'-9"
1'-4"
typ.
6
E2
E2
AF-6
2'-2"
SLOPE
14
SCALE: 1/4" = 1'-0"
1
FIRST FLOOR PLAN
GENERAL NOTES - FLOOR PLAN
A. CONTRACTOR TO VISIT SITE AND BECOME FAMILIAR WITH
EXISTING CONDITIONS PRIOR TO START OF WORK.
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING,
OF ALL DISCREPANCIES. CONTRACTOR TO DOCUMENT
EXISTING FIELD CONDITIONS, LIGHT FIXTURE AND MEP
SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL
OTHER CEILING ITEM LOCATIONS PRIOR TO CONSTRUCTION.
THIS INFORMATION SHALL BE PROVIDED TO ARCHITECT FOR
INCORPORATION INTO A CONSTRUCTION SET.
B. THE GENERAL CONTRACTOR AND EACH TRADE IS
RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW
WORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER
TRADES.
C. CONTRACTOR IS RESPONSIBLE TO PATCH/REPAIR/SEAL ALL
NEW & EXISTING PENETRATIONS INTO RATED WALLS TO
MAINTAIN RATED ASSEMBLY.
D. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED
WALLS SHALL BE SLEEVED AND FIRE STOPPED AS NECESSARY
TO MAINTAIN RATINGS.
E. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES
TO SUPPLY AND INSTALL COMPLETE, FOLLOWING
MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS
AND SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND
ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
F. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND
TIMING OF CONSTRUCTION WITH ARCHITECT AND OWNER.
G. PROVIDE WOOD BLOCKING IN WALL FOR ALL WALL-HUNG
ITEMS (CASEWORK, RESTROOM ACCESSORIES, FURNITURE,
ELECTRONICS, ETC.)
H. IN NO CASE SHALL THE WALL INTERFERE WITH EXISTING
WINDOWS. IF THIS OCCURS, MOVE WALL MINIMALLY TO
CORRECT THE PROBLEM. NOTIFY ARCHITECT AND
CONTRACTORS THAT WILL BE AFFECTED BY THIS CHANGE.
I. DIMENSIONS ARE INDICATED FROM FACE OF STUD TO FACE
OF STUD UNLESS DIMENSIONING TO AN EXISTING WALL OR
NOTED OTHERWISE.
J. UNLESS OTHERWISE NOTED, INTERIOR PARTITIONS SHALL BE
TYPE W2.3.
K. PROVIDE MOISTURE RESISTANT, TYPE "X" GYPSUM
WALLBOARD FOR ALL WALLS THAT INCLUDE PLUMBING LINES.
PLAN NOTES - FLOOR PLAN
1 ALIGN
2 EXISTING EQUIPMENT TO REMAIN
3 COORDINATE PLUMBING FIXTURE LOCATION WITH EXISTING
PIPING LOCATION.
4 EXISTING NIGHT DEPOSIT BOX TO REMAIN
5 WALL-MOUNTED ALUMINUM HANDRAIL
6 4" DIA. CONCRETE-FILLED GALVANIZED STEEL BOLLARD, 48" H.
PAINT TO MATCH COLUMNS.
7 COLUMN, REF. STRUCTURAL. PAINT WITH HIGH
PERFORMANCE COATING.
8 CURB, REF. CIVIL
9 POPLAR 1X6 WALL CAP, PAINT P-1
10 SEAL AROUND EXISTING WINDOW FRAMING TO REDUCE AIR
INFILTRATION
11 INSTALL 5/8" GYPSUM BOARD ON INTERIOR FACES OF WALLS
WHERE REMOVE BY DEMO CONTRACTOR, UP TO BOTTOM OF
ROOF TRUSSES, TYP ENTIRE FIRST FLOOR
12 LAMINATE 5/8" GYPSUM BOARD TO EXPOSED CMU AT
OPENINGS, TYP
13 1-1/2" RIGID INSULATION IN WALL CAVITY
14 THROUGH-WALL DRAIN AT BASE OF WINDOW WELL PAD.
LOCATE BETWEEN REBAR
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.
REVISIONS
DRAWING NAME
A1-1
MAIN LEVEL -
FLOOR PLAN
KG
20128
02/12/2021
BID SET
4775 E 126th St Carmel IN 46033
STATE BANK
20128 - CARMEL BRANCH
BID SET
02/12/2021
EQUIPMENT SCHEDULE
E1 THROUGH-WALL ATM OF OI
E2 PNEUMATIC TUBE SYSTE, OF OI
E3 SCANNER OF OI
E4 SHRED-BOX OF OI
E5 PRINTER OF OI
E6 COPY MACHINE OF OI
E7 MICROWAVE OF OI
E8 COFFEE MACHINE OF OI
E9 UNDER-COUNTER BOTTLE COOLER, SUMMIT APPLIANCE
100 CAN COOLER
OF CI
E10 REFRIGERATOR/FREEZER WITH ICE MAKER OF CI
E11 TELEVISION. PROVIDE IN-WALL BLOCKING. OF CI
E12 PLANTER. ITEM F1-MOD-TR1824 FROM PLANTERS
UNLIMITED OR SIMILAR.
CF CI
E13 FIRE EXTINGUISHER & CABINET CF CI
E14 DISHWASHER, ADA COMPLIANT HEIGHT OF CI
E15 IN-CABINET WASTE CONTAINER DRAWER, REV-A-SHELF
TANDEMBOX, TWCSC-2150DM-2 OR SIMILAR.
CF CI
E16 WALL-MOUNTED 72" CLASS TV. GC TO INSTALL IN-WALL
BLOCKING AND ARTICULATING BRACKET.
OF CI
E17 UTILITY WIRE SHELVING, BLACK POWDER COATED. ULINE
OR SIMILAR. SIZE: 36"Wx24"Dx72"H.
CF CI
E18 HOOK RACK, RICHELIEU 1322 CF CI
RESTROOM EQUIPMENT
R1 BACK WALL GRAB BAR CF CI
R2 SIDE WALL GRAB BAR CF CI
R3 SIDE WALL VERTICAL GRAB BAR CF CI
R4 TOILET, REF. PLMB. CF CI
R5 WALL MOUNTED LAVATORY, REF. PLMB. CF CI
R6 MIRROR CF CI
R7 TOILET PAPER DISPENSER CF CI
R8 COMBINATION PAPER TOWEL DISPENSER / WASTE
RECEPTACLE, SEMI-RECESSED
CF CI
R9 ROBE HOOK CF CI
R10 66" TURNING RADIUS - -
05/07/21