HomeMy WebLinkAboutA2-0ETR
8'-0" A.F.F.
ACT-3
8'-0" A.F.F.
ACT-3
8'-0" A.F.F.
ACT-2
8'-0" A.F.F.
ACT-2
8'-0" A.F.F.
ACT-1
8'-0" A.F.F.
ACT-2
8'-0" A.F.F.
ACT-2
8'-0" A.F.F.
ACT-2
8'-3" A.F.F.
WDC-1
7'-6" A.F.F.
ACT-2
8'-0" A.F.F.
GBC-1
8'-0" A.F.F.
GBC-1
7'-6" A.F.F.
ACT-2
8'-0" A.F.F.
STORAGE
004
KITCHEN
012
OFFICE
002
MECH/ELEC
005
RISER
016
WORKROOM
003
STOR.
015
OFFICE
011
RR
008
RR
009
COMMUNITY ROOM
013
OFFICE
014
CIRC
001
CIRC
010
CIRC
018
STOR
007
LIFT
017
ACT-2
8'-0" A.F.F.
1
2
2
2
4
4
A8-1
6
A6-3
SIM
LIGHT FIXTURES
XXX-1
1' - 0" A.F.F.
CEILING TYPE
CEILING HEIGHT
SCALE: 1/4" = 1'-0"
1
BASEMENT
RCP LEGEND
tel: 765.649.8477
www.krMarchitecture.com
ANDERSON
INDIANAPOLIS
DETROIT
DRAWN BY
krM JOB NO.
DRAWING NO.
REVISIONS
DRAWING NAME
A2-0
REFLECTED
CEILING PLAN -
LOWER LEVEL
KG
20128
02/12/2021
BID SET
4775 E 126th St Carmel IN 46033
STATE BANK
20128 - CARMEL BRANCH
BID SET
02/12/2021
GENERAL NOTES - REFLECTED
CEILING PLAN
A. DIMENSIONS ON REFLECTED CEILING PLAN ARE TAKEN
FINISHED FACE TO FINISHED FACE.
B. SEE ELECTRICAL FOR SWITCHING OPERATION AND
LOCATION.
C. COORDINATE ALL DUCTWORK AND LIGHTING WITH
STRUCTURE, BULKHEAD AND CEILING TO DECK
CLEARANCES PRIOR TO STARTING WORK.
D. LIGHTS AND DIFFUSERS SHOWN FOR LOCATION. SEE
ELECTRICAL AND HVAC PLANS FOR FIXTURE COUNTS AND
TYPES.
E. UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID
EACH DIRECTION IN ROOM. MAINTAIN MINIMUM EDGE TILE
AT 6".
F. PAINT GYPSUM BOARD CEILING SURFACES, P-1, UNLESS
INDICATED OTHERWISE
G. PROVIDE CONTROL JOINTS (C.J) IN GYPSUM BOARD
CEILING CONSTRUCTION AS INDICATED. WHERE NOT
SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF
30'-0". VERIFY FINAL C.J. LOCATIONS WITH ARCHITECT
PRIOR TO STARTING WORK WHETHER OR NOT INDICATED
ON THE DRAWINGS
H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED
TO LIMIT NUMBER OF PANELS REQUIRED, PANEL QUANTITY
SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS
WHETHER OR NOT INDICATED IN THE DRAWINGS. ALL
LOCATIONS SHALL BE REVIEWED WITH ARCHITECT PRIOR
TO STARTING WORK. PAINT ALL ACCESS PANELS TO
MATCH ADJACENT CEILING FINISH.
I. REFER TO A11 FINISH PLAN DRAWING SERIES FOR
ADDITIONAL CEILING FINISH INFORMATION AS WELL AS LIST
OF FINISHES/MATERIALS
J. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED
DIFFUSERS, GRILLE TYPES AND QUANTITIES. REVIEW FINAL
LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK.
PLAN NOTES - REFLECTED
CEILING PLAN
1 LOCATE CEILING AS TIGHT TO EXISTING JOISTS AS
POSSIBLE
2 WINDOW SHADE, WALL-MOUNTED, SINGLE ROLL-STYLE
3 WINDOW SHADE, MULLION-MOUNTED, DOUBLE
ROLL-STYLE
4 REPLACE BULBS IN EXISTING LIGHT SOCKETS
5 PNEUMATIC TUBE
6 PROVIDE 1 LAYER 1/2" THICK GYPSUM BOARD ON
BOTTOM OF TRUSSES, COVERING THE ENTIRE
FOOTPRINT OF THE ROOF. SEAL COMPLETELY ALL GAPS
BETWEEN BOARDS, AT THE PERIMETER, AND AT ALL
PENETRATIONS. PROVIDE 24"X24" ACCESS PANEL NEAR
MAIN DUCT CHASE.
7 CONTROL JOINT
8 BOX OUT BETWEEN SOFFIT AND WALL, WRAP IN METAL
PANELS. COLOR: CHAMPAGNE
9 24"X24" CONCEALED ACCESS PANEL. APPLY SOFFIT
MATERIAL TO MATCH ADJACENT.
10 VENTED METAL SOFFIT
11 FLAT PAN METAL SOFFIT
CEILING SCHEDULE
ACT-1 2x2 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO
SPECIFICATIONS.
ACT-2 2x4 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO
SPECIFICATIONS
ACT-3 2x6 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO
SPECIFICATIONS.
ETR EXISTING CEILING TO REMAIN
GBC-1 5/8" GYP. BD. ON METAL STUD - PAINT, REFER TO FINISH
SCHEDULE
GBC-2 1/2" GYP. BD. ON EXISTING FURRING. TAPE AND MUD
JOINTS.
MTL-1 WOOD-LOOK LONGBOARD METAL PANEL SOFFIT,
REFERENCE DETAILS
WDC-1 WOOD PLANK CEILING SYSTEM, REFER TO
SPECIFICATIONS AND LIST OF MATERIALS AND
FINISHES
05/07/21