Loading...
HomeMy WebLinkAboutA2-0ETR 8'-0" A.F.F. ACT-3 8'-0" A.F.F. ACT-3 8'-0" A.F.F. ACT-2 8'-0" A.F.F. ACT-2 8'-0" A.F.F. ACT-1 8'-0" A.F.F. ACT-2 8'-0" A.F.F. ACT-2 8'-0" A.F.F. ACT-2 8'-3" A.F.F. WDC-1 7'-6" A.F.F. ACT-2 8'-0" A.F.F. GBC-1 8'-0" A.F.F. GBC-1 7'-6" A.F.F. ACT-2 8'-0" A.F.F. STORAGE 004 KITCHEN 012 OFFICE 002 MECH/ELEC 005 RISER 016 WORKROOM 003 STOR. 015 OFFICE 011 RR 008 RR 009 COMMUNITY ROOM 013 OFFICE 014 CIRC 001 CIRC 010 CIRC 018 STOR 007 LIFT 017 ACT-2 8'-0" A.F.F. 1 2 2 2 4 4 A8-1 6 A6-3 SIM LIGHT FIXTURES XXX-1 1' - 0" A.F.F. CEILING TYPE CEILING HEIGHT SCALE: 1/4" = 1'-0" 1 BASEMENT RCP LEGEND tel: 765.649.8477 www.krMarchitecture.com ANDERSON INDIANAPOLIS DETROIT DRAWN BY krM JOB NO. DRAWING NO. REVISIONS DRAWING NAME A2-0 REFLECTED CEILING PLAN - LOWER LEVEL KG 20128 02/12/2021 BID SET 4775 E 126th St Carmel IN 46033 STATE BANK 20128 - CARMEL BRANCH BID SET 02/12/2021 GENERAL NOTES - REFLECTED CEILING PLAN A. DIMENSIONS ON REFLECTED CEILING PLAN ARE TAKEN FINISHED FACE TO FINISHED FACE. B. SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION. C. COORDINATE ALL DUCTWORK AND LIGHTING WITH STRUCTURE, BULKHEAD AND CEILING TO DECK CLEARANCES PRIOR TO STARTING WORK. D. LIGHTS AND DIFFUSERS SHOWN FOR LOCATION. SEE ELECTRICAL AND HVAC PLANS FOR FIXTURE COUNTS AND TYPES. E. UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION IN ROOM. MAINTAIN MINIMUM EDGE TILE AT 6". F. PAINT GYPSUM BOARD CEILING SURFACES, P-1, UNLESS INDICATED OTHERWISE G. PROVIDE CONTROL JOINTS (C.J) IN GYPSUM BOARD CEILING CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY FINAL C.J. LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK WHETHER OR NOT INDICATED ON THE DRAWINGS H. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF PANELS REQUIRED, PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED ACCESS WHETHER OR NOT INDICATED IN THE DRAWINGS. ALL LOCATIONS SHALL BE REVIEWED WITH ARCHITECT PRIOR TO STARTING WORK. PAINT ALL ACCESS PANELS TO MATCH ADJACENT CEILING FINISH. I. REFER TO A11 FINISH PLAN DRAWING SERIES FOR ADDITIONAL CEILING FINISH INFORMATION AS WELL AS LIST OF FINISHES/MATERIALS J. REFER TO MECHANICAL DRAWINGS FOR CEILING-MOUNTED DIFFUSERS, GRILLE TYPES AND QUANTITIES. REVIEW FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK. PLAN NOTES - REFLECTED CEILING PLAN 1 LOCATE CEILING AS TIGHT TO EXISTING JOISTS AS POSSIBLE 2 WINDOW SHADE, WALL-MOUNTED, SINGLE ROLL-STYLE 3 WINDOW SHADE, MULLION-MOUNTED, DOUBLE ROLL-STYLE 4 REPLACE BULBS IN EXISTING LIGHT SOCKETS 5 PNEUMATIC TUBE 6 PROVIDE 1 LAYER 1/2" THICK GYPSUM BOARD ON BOTTOM OF TRUSSES, COVERING THE ENTIRE FOOTPRINT OF THE ROOF. SEAL COMPLETELY ALL GAPS BETWEEN BOARDS, AT THE PERIMETER, AND AT ALL PENETRATIONS. PROVIDE 24"X24" ACCESS PANEL NEAR MAIN DUCT CHASE. 7 CONTROL JOINT 8 BOX OUT BETWEEN SOFFIT AND WALL, WRAP IN METAL PANELS. COLOR: CHAMPAGNE 9 24"X24" CONCEALED ACCESS PANEL. APPLY SOFFIT MATERIAL TO MATCH ADJACENT. 10 VENTED METAL SOFFIT 11 FLAT PAN METAL SOFFIT CEILING SCHEDULE ACT-1 2x2 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO SPECIFICATIONS. ACT-2 2x4 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO SPECIFICATIONS ACT-3 2x6 SUSPENDED ACOUSTICAL CEILING TILE, REFER TO SPECIFICATIONS. ETR EXISTING CEILING TO REMAIN GBC-1 5/8" GYP. BD. ON METAL STUD - PAINT, REFER TO FINISH SCHEDULE GBC-2 1/2" GYP. BD. ON EXISTING FURRING. TAPE AND MUD JOINTS. MTL-1 WOOD-LOOK LONGBOARD METAL PANEL SOFFIT, REFERENCE DETAILS WDC-1 WOOD PLANK CEILING SYSTEM, REFER TO SPECIFICATIONS AND LIST OF MATERIALS AND FINISHES 05/07/21