HomeMy WebLinkAboutA010.5104
RESTORE HYPER
WELLNESS
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
6
6
6
6
6
5
1
2
2
2
2
9
7 2
8
4
4
W1A W1A
W1A
W1A
3
3
3
3
3
3
3 3
3
3
3
3
7'-8" 10'-0" 4'-9 12'-0"
1
8"
14'-0" 12'-6" 5'-0" 13'-11
1
2" 12'-5"
14'-0" 9'-0" 5'-9" 5'-10" 5'-9" 16'-0"
5'-0" 13'-1"6'-11
1
8" 9'-10"
2'-2"
4'-7 7 9'-10"
11'-5 8'-6" 8"
1
4"
6'-2" 5'-3" 13'-8
1
2"
12'-0"
8'-41
4"
6'-0"
1'-8"
4'-2" 3'-11" 5'-0"
5
3
4"
13'-0 3'-9" 6'-1"
1
8"
3
W3
RECEPTION
OPEN IV DRIP /
COMPRESSION
NURSE / MIXING SLEEP THERAPY
CRYOSKIN
DRY SAUNA
CRYO. ROOM
SHOWER
DRESS HALL
HALL
TOILET
LAUNDRY / OFFICE
STRETCH
TANK
DRESSING
DRESSING
W3A W3
W3A
W2
W3
2
W2A
7'-11"
8'-0"
W2A
115
W1A
12
11
10
SD1
TD1 GB1
GB1
GB TT1
M1
W2A
7'-11"
8'-0"
W2A
W1A
2
2
10
SD1
TD1
GB1
TT1
GB
M1
GB1
116
A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL
DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM
WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY.
B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR
METAL STUD FRAMING, UNLESS OTHERWISE NOTED.
C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD
CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL.
D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS
FOR ANY WALL SUPPORTED ITEMS.
E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY
OPENINGS IN FIRE RATED ASSEMBLIES.
F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS,
FINISHES, AND HARDWARE INFORMATION.
G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND
OTHER EXPANSION JOINT LOCATIONS.
H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED
FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE
COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO
INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING,
TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN
LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR
CEILING HUNG ITEMS.
I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL
SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS
TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR
SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED
INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY
THE ARCHITECT.
J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL
REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS,
ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH
UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR
NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR
BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION.
K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE
SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME.
L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB
INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL.
M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF
THE ANSI 117.1 2009
GENERAL NOTES
KEYED NOTES
KEY PLAN
ISSUE DATE
200275
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C COPYGRIHT 2021, CURRANARCHI TECTURE
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
MULTI-TENANT BUILDING
11100 N. MICHIGAN ROAD
CARMEL, INDIANA
46077
N
PROJECT
LOCATION
BENNETT PKWY
U.S. HIGHWAY 421
PERMIT SET 02.25.2021
REED RD.
ENLARGED
FLOOR PLANS
A102
FLOOR PLAN 1
1/4"= 1'-0"
*THIS SHEET ONLY
1. TANK FILL BOX: CHART, PERMA WALL BOX GEN II, SURFACE
MOUNT. COORDINATE FINAL LOCATION & CLEARANCES WITH
TENANT.
2. CONTRACTOR TO PROVIDE WATER LINES & WASTE LINES FOR
FUTURE SINK, TOILET, OR SHOWER. SEE PLUMBING PLANS.
FIXTURES BY TENANT.
3. CONTRACTOR TO PROVIDE ROUGH OPENINGS FOR FUTURE
DOOR.
4. PREP WALL FOR FUTURE POCKET DOOR.
5. FUTURE CRYOGENIC TANK. COORDINATE SPECIFICATIONS &
SIZING WITH TENANT. TENANT TO BE RESPONSIBLE FOR SIZING
OF SLAB & ANY REQUIRED EXPANSION JOINTS & INSULATION
UNDER SLAB.
6. FUTURE GLASS SYSTEM / WINDOW BY TENANT.
7. CONTRACTOR TO PROVIDE WATER LINES & WASTE LINES FOR
FUTURE MOP SINK & WATER HEATER ABOVE.
8. CONTRACTOR TO PROVIDE ELECTRICAL, DRYER VENT, WATER
LINES & WASTE LINES FOR FUTURE STACKED WASHER & DRYER.
SEE MECHANICAL & PLUMBING PLANS.
9. CONTRACTOR TO PROVIDE WATER LINES & WASTE LINES FOR
FUTURE HI / LOW DRINKING FOUNTAINS. SEE PLUMBING PLANS.
10. FLOOR DRAIN.
11. FLOOR MOUNTED ADA COMPLIANT TANK TYPE TOILET. SEE
PLUMBING PLANS.
12. WALL MOUNTED ADA COMPLIANT SINK. PROVIDE SCALD
GUARDS ON ALL EXPOSED PLUMBING.
NOTE: PLEASE VERIFY LAYOUT W/
TENANT & FINAL PLANS BEFORE
WORK STARTS.
FLOOR PLAN 2
1/4"= 1'-0"
TOILET ACCESSORY SCHEDULE
MARK SYMBOL MFR # DESCRIPTION
TT1
BOBRICK
B-2888
MULTI-ROLL TOILET TISSUE DISPENSER
GB1
BOBRICK
B-5806 X 36
B-5806 X 42
36" AND 42" GRAB BARS
GB2
BOBRICK
B-5806 X 18
18" VERTICAL GRAB BAR
M1
BOBRICK
B-165
MIRROR 2'-0" X 4'-0"
TD1
BOBRICK
B-3944
TOWEL DISPENSER / WASTE RECEPTACLE
SD1
BOBRICK
B-2112
SOAP DISPENSER
FLOOR PLAN 3
1/4"= 1'-0"
N
N
N
05/10/21