HomeMy WebLinkAboutA010.131'-4" FLASHING CONCRETE BLOCK VENEER 2" EXTRUDED RIGID INSULATION, PROVIDE MANUFACTURER'S JOINT TAPE. COVER WITH AIR INFILTRATION BARRIER. TAPE AIR BARRIER JOINTS 8" METAL STUD FRAMING W/ R-21 INSULATION EXTERIOR SHEATHING TREATED 2X CONTINUOUS 5 8" GYP. BD. OVER VAPOR BARRIER AIR INFILTRATION BARRIER TO WRAP TO INTERIOR FACE OF FRAMING BACKER ROD & SEALANT WINDOW AS SCHEDULED MODULAR BRICK BRICK TIE, VERIFY SPACING STEEL MASONRY DRIP EDGE STEEL PLATE. SEE STRUCTURAL DRAWINGS BACKER ROD & SEALANT WINDOW AS SCHEDULED SHIM AS REQUIRED 1'-4" MEMBRANE FLASHING 2" EXTRUDED RIGID INSULATION, PROVIDE MANUFACTURER'S JOINT TAPE. COVER WITH AIR INFILTRATION BARRIER. TAPE AIR BARRIER JOINTS WEEP TUBES W/ SCREENS @ 16" OC MAX PROVIDE FLASHING MANU RECOMMENDED TERMINATION DETAIL CAVITY PROTECTION MATERIAL. FULL DEPTH OF CAVITY AWNING 8" METAL STUD FRAMING W/ R-21 INSULATION EXTERIOR SHEATHING SEE STRUCTURAL DRAWINGS 5 8" GYP. BD. OVER VAPOR BARRIER DETAIL 1 1 1/2" = 1'-0" ISSUE DATE 200275 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C COPYGRIHT 2021, CURRANARCHI TECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM MULTI-TENANT BUILDING 11100 N. MICHIGAN ROAD CARMEL, INDIANA 46077 PERMIT SET 02.25.2021 SECTIONS AND DETAILS A502 DETAIL 2 1 1/2" = 1'-0" 05/10/21