HomeMy WebLinkAboutE001.1ABBREVIATIONS UNDERWRITERS LABORATORIES, INC. UNDERGROUND UNLESS OTHERWISE NOTED MAXIMUM OVER CURRENT PROTECTION MCB MAIN CIRCUIT BREAKER METAL HALIDE MINIMUM MTD MOUNTED MOCP MIN MH LOCKED ROTOR AMPS MINIMUM CIRCUIT AMPACITY MAXIMUM LIGHTING MAX MCA LTG LRA KILOVOLT-AMPS KILOWATT-HOUR KILOWATTS KVA KWH KW HEATER HVAC HEATING, VENTILATING & A/C HTR GENERAL CONTRACTOR GFI, GFIC GROUND FAULT INTERRUPTER GC FOOT, FEET ELECTRICAL WATER COOLER EXISTING FIRE ALARM FULL LOAD AMPS FIRE ALARM CONTROL PANEL EXHAUST FT FACP FLA FA EX, EXIST EWC EXH W WATT, WIDTH VA UL UON UG T/C VOLT-AMPERE TIME CLOCK SQUARE FEET, SQUARE FOOT REFLECTED CEILING PLAN NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. OCCUPATIONAL SAFETY &HEALTH ADMIN. DWG DRAWING DECIBEL DIAMETER DISCONNECT DOWN DIA DN DISC dB THRU THROUGH SF RTU RR REMOVE AND RELOCATE ROOF TOP UNIT CLOSED CIRCUIT TELEVISION CIRCUIT CEILING CABLE TELEVISION SYSTEM CKT CLG CCTV CATV REV RCP REVISION PVC PF PH POLYVINYL CHLORIDE POWER FACTOR PHASE AMERICAN NAT'L STANDARDS INSTITUTE ABOVE FINISHED GRADE ARCHITECT, ARCHITECTURAL AUDIO/VISUAL ABOVE FINISHED FLOOR ABOVE FINISHED CEILING A/V AFG ARCH ANSI AFF AFC OSHA OC NFPA NTS N.O. NIC ON CENTER NOT TO SCALE NORMALLY OPEN NOT IN CONTRACT NEC NEMA N/A NOT APPLICABLE ETR EXISTING TO REMAIN REX REMOVE EXISTING BREAKER BLDG BUILDING BKR BMS BUILDING MANAGEMENT SYSTEM GROUND ELECTRICAL SYMBOLS "IG" INDICATES ISOLATED GROUND TYPE "WP" INDICATES WEATHERPROOF COVER "54" INDICATES 54" AFF "C" INDICATES MOUNTED 8" ABOVE COUNTER DRY TYPE TRANSFORMER "2" INDICATES CIRCUIT NUMBER DISCONNECT SWITCH UNFUSED JUNCTION BOX CIRCUITRY TURNING UP INFLOOR/UNDERFLOOR CONDUIT/WIRE PANELBOARD - 208Y/120 VOLT, 3Ø, 4 WIRE PANELBOARD - 480Y/277 VOLT, 3Ø, 4 WIRE 1,3,5 A "a" INDICATES SWITCHED FIXTURE CONTROL EMERGENCY LIGHTING BATTERY UNIT WITH HEADS AS INDICATED. TIME CLOCK NL A a 13 "OS" INDICATES DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH "C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER "3" INDICATES THREE WAY SWITCH S PUSHBUTTON DOOR BUZZER FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80" AFF. FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF. FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80" AFF. HOMERUN TO PANEL "A", CIRCUIT #1,3,5 (VIA 20A-1P CIRCUIT BREAKERS), TWO #12 CONDUCTORS (MINIMUM SIZE), UON. A GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL CONDUITS. REFER TO SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS. DISCONNECT SWITCH FUSED: "AS" - INDICATES AMPERE SWITCH SIZE "AF" - INDICATES AMPERE FUSE SIZE "GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. FIRE RATED POKE-THROUGH DEVICE "T" INDICATES TELEPHONE/DATA "D" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR "DF" INDICATES FLUORESCENT DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR LIGHT FIXTURE: "A" INDICATES FIXTURE TYPE, "13" INDICATES CIRCUIT NUMBER, "a" INDICATES SWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. COMBINATION VOICE/DATA OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8" ABOVE COUNTER. DOOR BELL FIRE ALARM DUCT MOUNTED SMOKE DETECTOR WITH SAMPLING TUBE, FURNISHED AND WIRED BY EC, MOUNTED BY MC. LIGHTING FIXTURE WITH 1 BALLAST WIRED TO EMERGENCY AND/OR NIGHT LIGHTING CKT. SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1-HP RATED, 20 AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED: "P" INDICATES DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. SINGLE (SIMPLEX) RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRAWINGS. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED: TELEPHONE FIRE RATED PLYWOOD BACKBOARD - SIZE INDICATED ON PLAN DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. C CONDUIT (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) AUX AUXILIARY BAS BUILDING AUTOMATION SYSTEM DDC DIRECT DIGITAL CONTROL C/B CIRCUIT BREAKER D DEEP, DEPTH EC ELECTRICAL CONTRACTOR FPC FIRE PROTECTION CONTRACTOR HID HIGH INTENSITY DISCHARGE L LENGTH IBC INTERNATIONAL BUILDING CODE LED LIGHT EMITTING DIODE MECH MECHANICAL MC MECHANICAL CONTRACTOR N.C. NORMALLY CLOSED P POLE MCC MOTOR CONTROL CENTER PB PUSH BUTTON PC PLUMBING CONTRACTOR A AMP, AMPERES IN INCH, INCHES DELTA CT CURRENT TRANSFORMER G,GRD SE SERVICE ENTRANCE XFMR TRANSFORMER Y WYE Δ REMOTE ANNUNCIATOR LIGHT/AUDIBLE ALARM FOR DUCT SMOKE DETECTOR AWG AMERICAN WIRE GAUGE ADA AMERICANS WITH DISABILITIES ACT CUBIC FEET PER MINUTE CW COLD WATER CFM EF EXHAUST FAN EMT ELECTRICAL METALLIC TUBING FARA FIRE ALARM REMOTE ANNUNCIATOR MUA MAKE UP AIR O/H OVERHEAD RM RLA RUNNING LOAD AMPS ROOM RGS RIGID GALVANIZED STEEL TRANS TRANSFORMER TYP TYPICAL UPS UNINTERRUPTED POWER SUPPLY W/ WITH POWER POLE "4" INDICATES FOUR WAY SWITCH "3" INDICATES THREE WAY SWITCH SWITCH - DUAL TECHNOLOGY, CEILING MOUNTED - SINGLE POLE, TOGGLE TYPE - 120/277 VOLT, 20 AMPERE "4" INDICATES FOUR WAY SWITCH WP WEATHERPROOF REMOTE EMERGENCY WEATHERPROOF LIGHTING HEAD SUPPLIED FROM REMOTE BATTERY UNIT. DATA OUTLET MOUNTED IN FLOOR BOX FIRE ALARM REMOTE ANNUNCIATOR FIRE ALARM CONTROL PANEL DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN CEILING. FIRE ALARM HEAT DETECTOR DACT DIGITAL ALARM COMMUNICATING TRANSMITTER FIRE ALARM CARBON MONOXIDE DETECTOR TAMPER SWITCH FLOW SWITCH KITCHEN HOOD SUPPRESSION SYSTEM FIRE PUMP CONTROL PANEL ELECTRICAL SPECIFICATIONS DIVISION 26 - ELECTRICAL I. GENERAL PROVISIONS A. GENERAL CONDITIONS, CODES & STANDARDS 1. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) AND ANY OF THE OWNER'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. 2. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. 3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE OWNER REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. 4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 5. ALL EQUIPMENT AND MATERIALS USED SHALL BE NEW AND UL LISTED FOR THE APPLICATION, AND SHALL BEAR AN APPROPRIATE UL LABEL. B. SCOPE OF WORK 1. THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE OWNER A COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEM. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE WORK IS COMMENCED. 3. CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND ELECTRICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. 5. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS, AND WALLS PENETRATED. 6. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED WIRING AND CONDUIT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 9. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND OWNER. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. C. DOCUMENTS 1. THE DRAWINGS ARE DIAGRAMMATIC; ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE OWNER. 2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL AND MUST BE SUBMITTED AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. COORDINATION 1. CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 2. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB-TRADE'S PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE OWNER BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 3. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AT SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE OPERATIONS OF THE SPACE, ADJACENT SPACES, OR FACILITY. A WORK SCHEDULE SHALL BE ARRANGED WITH THE OWNER, INCLUDING PREMIUM TIME WORK TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE TO THE OWNER'S OPERATIONS. E. METHODS 1. EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. CONDUIT SHALL BE LAID ON AN APPROPRIATELY GRADED 6" BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO BACKFILL TO 6" ABOVE THE CONDUIT. BACKFILL THE REMAINDER OF THE TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE OWNER. IF THE EXCAVATED MATERIALS ARE NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL SHALL BE ACCOMPLISHED IN 9" LIFTS WITH ALL LIFTS COMPACTED TO 95% PROCTOR. PATCH FLOOR TO MATCH EXISTING. 2. EQUIPMENT, CONDUIT, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, OTHER CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 3. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL BE PERFORMED BY THE OWNER'S ROOFING CONTRACTOR AT THE REQUESTING CONTRACTORS COST. F. SUBMITTALS 1. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT OF ALL EQUIPMENT AND ACCESSORIES PROVIDED FOR THE PROJECT WHETHER SPECIFIED HERE-IN OR ON THE DRAWINGS. REVIEW OF THE SHOP DRAWINGS SHALL BE FOR GENERAL DESIGN CONCEPT AND ADHERENCE WITH THE SPECIFICATIONS. QUANTITY OF SHOP DRAWINGS SUBMITTED SHALL BE AS SPECIFIED BY THE ARCHITECT. SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR SHOWING LOCATIONS AND MEASUREMENTS FROM COLUMNS OF ALL CONCEALED AND EXPOSED PIPING, DUCTWORK, CONDUIT, EQUIPMENT, ACCESSORIES, ETC., AND SUBMITTED PRIOR TO INSTALLATION. THE OWNER MAY MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP DRAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFIRMING ALL INFORMATION ON THE DRAWINGS PRIOR TO FABRICATION AND/OR INSTALLATION. 2. PROJECT RECORD DOCUMENTS - MAINTAIN AT THE JOBSITE ONE COPY OF ALL CONTRACT DOCUMENTS CLEARLY MARKED AS “PROJECT RECORD COPY”. THESE DRAWINGS ARE TO BE MAINTAINED IN GOOD CONDITION, UPDATED DAILY FOR CHANGES ENCOUNTERED AND AVAILABLE AT ALL TIMES FOR INSPECTION BY THE OWNER. DO NOT USE FOR FIELD CONSTRUCTION! PROJECT RECORD DOCUMENTS ARE TO BE KEPT CURRENT WITH EXACT DIMENSIONS OF ALL WORK, EQUIPMENT, DISTRIBUTION CONDUIT, CIRCUITS, ETC. MARK ALL INFORMATION IN RED LINES AND NOTES SO AS TO BE EASILY IDENTIFIED FROM THE BASE DRAWING. UPON COMPLETION OF THE WORK, ONE SET OF THESE DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AS ONE QUALIFICATION FOR FINAL PAYMENT. 3. THREE COMPLETE SETS OF AS-BUILT DOCUMENTATION SHALL BE PROVIDED. IT SHALL INCLUDE, BUT NOT BE LIMITED TO ACCURATE PLAN DRAWINGS, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. 4. SUBMIT OVERCURRENT DEVICE COORDINATION STUDY INCLUDING EQUIPMENT EVALUATION REPORTS, ONE LINE DIAGRAM, PROTECTIVE DEVICE COORDINATION STUDY AND TIME-CURRENT COORDINATION CURVES. STUDY ELECTRICAL DISTRIBUTION SYSTEM FROM NORMAL AND ALTERNATE POWER SOURCES. THE STUDY SHALL COMPLY WITH IEEE 399 FOR GENERAL STUDY REQUIREMENTS. II. PRODUCTS A. CONDUIT 1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO DAMAGE, 8'-0" AFF AND BELOW, AND IN WET LOCATIONS WHERE INDICATED ON THE DRAWINGS. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED (3' MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE USED IF APPROVED BY THE OWNER, AND INSTALLED IN LOCATIONS PERMITTED BY CODE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION. B. CONDUIT FITTINGS AND BOXES 1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSTALLED. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT. 2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SQUARE, 1-1/2 INCHES DEEP. 3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL. BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. C. WIRE AND CABLE 1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW 600-VOLT, 90°C, TYPE XHHW, THHW, OR THWN INSULATION, MINIMUM SIZE #12-AWG, EXCEPT FOR CONTROL WIRING WHICH MAY BE #14-AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BY THE OWNER. 2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE LAST DEVICE, SHALL BE #10-AWG CONDUCTORS UNLESS OTHERWISE NOTED. 3. COMPRESSION TYPE LUGS AND CONNECTORS SHALL BE USED FOR ALL TERMINATIONS AND SPLICES. 4. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED. D. WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 3. COLORS OF DEVICES SHALL BE SELECTED BY ARCHITECT. 4. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC. E. LIGHTING AND RECEPTACLE PANELBOARDS 1. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A SURFACE OR FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, APPLICATION UNLESS NOTED OTHERWISE. 2. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE; WITH MOLDED PLASTIC CASE; 1, 2, OR 3 POLE AS INDICATED; QUICK-MAKE, QUICK-BREAK; AND THERMAL-MAGNETIC TRIP DEVICE. 3. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACR RATED, UNLESS OTHERWISE NOTED. 4. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. 5. INDIVIDUAL SINGLE POLE CIRCUIT BREAKERS, WITH IDENTIFIED TIES, OR 2/3 POLE BREAKERS SHALL BE PROVIDED FOR EACH UNGROUNDED CONDUCTOR IN ALL MULTI-WIRE BRANCH CIRCUITS. 6. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS, AND CUTLER HAMMER. F. SAFETY SWITCHES AND MOTOR STARTERS 1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON-FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK-MAKE, QUICK-BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSES SHALL BE DUAL ELEMENT - TIME DELAY TYPE. 2. ALL MOTORS OVER 1/8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS AND/OR MOTOR CONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS. 3. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. G. LUMINAIRES AND LAMPS 1. ALL LUMINAIRES SHALL BE SPECIFIED ON THE LUMINAIRE SCHEDULE. 2. ALL FIXTURE / BALLAST / LAMP COMBINATIONS SHALL BE ENERGY SAVING TYPE. H. FIRE ALARM SYSTEM 1. A COMPLETE FIRE ALARM SYSTEM SHALL BE PROVIDED AS DESCRIBED ON THE DRAWINGS. ALL DEVICES, WIRING, BACKBOXES, PROGRAMMING, START-UP, INSTRUCTION AND TESTING REQUIRED FOR A COMPLETE OPERATING SYSTEM SHALL BE PROVIDED. 2. THE ELECTRICAL CONTRACTOR SHALL FURNISH SHOP DRAWINGS, COMPLETE WITH EQUIPMENT CUTS AND FLOOR PLANS (WITH WIRING INDICATED), AS WELL AS BATTERY CALCULATIONS, AND VOLTAGE DROP CALCULATIONS FOR REVIEW AND APPROVAL BY THE ARCHITECT, ENGINEER, AND ALL AUTHORITIES HAVING JURISDICTION. FLOOR PLAN DRAWINGS SHALL BE STAMPED BY A PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR AND/OR SUPPLIER. NICET 4 CERTIFICATION AND STAMP IS ACCEPTABLE, IF APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. THE ELECTRICAL CONTRACTOR SHALL FURNISH FIRE ALARM DRAWINGS, CALCULATIONS, AND EQUIPMENT INFORMATION FOR ALL REQUIRED LOCAL MUNICIPALITY, OR STATE PERMITS. THE ELECTRICAL CONTRACTOR SHALL ARRANGE AND COORDINATE ALL REQUIRED TESTING AND INSPECTIONS REQUIRED BY THE LOCAL MUNICIPALITY FIRE DEPARTMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE FIRE DEPARTMENT COSTS IN BID. 4. ALL HVAC UNITS OR GROUP OF HVAC UNITS WITH A COMMON PLENUM AND A DESIGN CAPACITY GREATER THAN 2000 CFM SHALL AUTOMATICALLY SHUT DOWN ASSOCIATED HVAC UNIT OR UNITS. WHERE A DUCT SMOKE DETECTOR IS NOT VISIBLE OR ACCESSIBLE FROM THE FLOOR, REMOTE AUDIBLE/VISUAL ALARM INDICATOR/TEST SWITCHES SHALL BE PROVIDED IN AN APPROVED LOCATION, AT A HEIGHT ACCESSIBLE AND VISIBLE FROM THE FLOOR. HVAC DUCT DETECTORS SHALL BE CONNECTED TO A CENTRAL STATION MONITORING SYSTEM UNDER SEPARATE CONTRACT WITH THE OWNER. 5. FIRE ALARM SIGNAL SHALL INITIATE THE FOLLOWING ACTIONS: a. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. b. IDENTIFY ALARM AND SPECIFIC INITIATION DEVICE AT FIRE CONTROL PANEL. c. TRANSMIT ALARM TO LANDLORD SYSTEM. d. TRANSMIT ALARM SIGNAL TO REMOTE RECEIVING STATION. e. INTERRUPT TENANT SOUND SYSTEM. f. UNLOCK ELECTRIC DOORS IN EGRESS PATHS. g. RELEASE FIRE AND SMOKE DOORS HELD OPEN BY MAGNETIC DOOR HOLDERS. h. SHUT DOWN AIR HANDLING SYSTEMS. i. ACTIVATE EMERGENCY GAS AND HOOD EQUIPMENT SHUTOFFS. j. SWITCH HVAC EQUIPMENT CONTROLS TO FIRE ALARM MODE. 6. ALL FIRE ALARM VISIBLE DEVICES SHALL BE ADA COMPLIANT WITH A MINIMUM CANDELA RATING OF 75. CEILING MOUNTED DEVICES SHALL HAVE A RATING WITH THE LISTED REQUIREMENTS FOR A SPECIFIC CEILING HEIGHT. 7. ALL WALL MOUNTED STROBES, SPEAKER-STROBES, OR HORN STROBES SHALL BE MOUNTED SUCH THAT THE LENS IS NOT LESS THAN 80 INCHES AND NOT MORE THAN 96 INCHES ABOVE THE FINISHED FLOOR. 8. ALL AUDIBLE NOTIFICATION APPLIANCES SHALL BE SET TO ACHIEVE A SOUND PRESSURE AT LEAST 15dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL. 9. ALL CABLES FOR THE FIRE ALARM SYSTEM SHALL BE RATED FOR THE INTENDED USE. 10. FIRE ALARM SYSTEM MONITORING SHALL BE BY OTHERS UNDER SEPARATE CONTRACT WITH THE OWNER. 11. PROVIDE A SEPARATE LINE ITEM COST FOR A (1), (3), (5) YEAR MAINTENANCE, TESTING AND MONITORING AGREEMENT. AGREEMENT TO INCLUDE MONITORING TO A UL LISTED CENTRAL STATION PER NFPA 72 REQUIREMENTS, ALL CODE REQUIRED TESTING OF THE FIRE ALARM SYSTEM PER NFPA 72 AND OBC (MONTHLY VISUAL INSPECTION SHALL BE BY THE OWNER), CLEANING OF DEVICES SHALL BE DONE UPON SYSTEM REQUEST, AND ALL COST ASSOCIATED WITH MAINTENANCE OF THE SYSTEM SHALL BE PROVIDED (DUE TO DEFECTIVE EQUIPMENT ONLY). PROVIDE A YEARLY REPORT TO THE OWNER. 12. FIRE ALARM SYSTEM SHALL BE BY SIMPLEX, NOTIFIER, FCI, SIEMENS OR GAMEWELL. I. METER CENTER 1. METER CENTER SHALL BE RATED FOR 208/120V, THREE PHASE, FOUR WIRE OPERATION WITH TIN PLATED ALUMINUM BUSBARS, 100% RATED NEUTRAL BUS AND GROUND BUS. SWITCHBOARD SHALL BE SERVICE ENTRANCE RATED. REFER TO DRAWINGS FOR ADDITIONAL REQUIREMENTS. 2. METER CENTER SHALL BE FRONT ACCESSIBLE WITH SIDE ACCESS TO THE MAIN DEVICE. MAIN DEVICE SHALL BE INDIVIDUALLY MOUNTED. BRANCH DEVICES WITH HOT SEQUENCE UTILITY METERING SHALL BE INDIVIDUALLY MOUNTED. SECTIONS SHALL BE FRONT AND REAR ALIGNED, PROVIDE (3) METERS PER VERTICAL SECTION. 3. ENCLOSURE SHALL BE NEMA 3R WITH HINGED FRONT DOORS. 4. FUTURE DEVICES: EQUIP COMPARTMENTS WITH MOUNTING BRACKETS, SUPPORTS, BUS CONNECTIONS, AND APPURTENANCES AT FULL RATING OF BRANCH FEEDER COMPARTMENT. 5. MAIN HEAVY DUTY SWITCH: a. OPERATING MECHANISM: MANUAL HANDLE OPERATION TO CLOSE SWITCH. b. SERVICE-RATED SWITCHES: LABELED FOR USE AS SERVICE EQUIPMENT. 6. FUSED SWITCH: NEMA KS 1, TYPE HD; CLIPS TO ACCOMMODATE SPECIFIED FUSES; LOCKABLE HANDLE. 8. EQUIPMENT MOUNTING: INSTALL METERING CENTER ON CONCRETE BASE, 4-INCH NOMINAL THICKNESS WITH CHAMFERED EDGES. 9. DEVICE NAMEPLATES: LABEL EACH DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICE AND EACH METER AND CONTROL DEVICE MOUNTED IN COMPARTMENT DOORS WITH A NAMEPLATE. III. EXECUTION A. GENERAL MISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4" SHALL NOT BE USED FOR ANY CIRCUIT HOMERUNS. 2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL CODE. 3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. ACCESS PANELS SHALL BE PROVIDED FOR ALL JUNCTION BOXES AND PULL BOXES INSTALLED ABOVE DRYWALL CEILINGS, COORDINATE SIZE AND LOCATION WITH ARCHITECT. 5. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410-30 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES WHICH MY APPLY. 6. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. 7. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 8. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 9. THE ELECTRICAL CONTRACTOR SHALL BALANCE PANELBOARD LOADING TO WITHIN 10% ON EACH PHASE BASED ON INSTALLED CONDITIONS. LOAD BALANCING CIRCUIT CHANGES SHALL BE PERFORMED OUTSIDE THE NORMAL OCCUPANCY WORKING SCHEDULE AND AT A TIME DIRECTED BY LANDLORD. 10. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING-IN, AT NO ADDITIONAL COST TO THE OWNER. 11. CONTACT ELECTRIC POWER COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR ELECTRIC SERVICE. 12. CONTACT TELEPHONE COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR TELEPHONE SERVICE. 13. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING OWNER'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING OF DEBRIS. 14. ALL SERVICE EQUIPMENT SHALL BE IDENTIFIED AS BEING SUITABLE FOR USE AS SERVICE EQUIPMENT. SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AND THE DATE THE CALCULATION WAS PERFORMED. FIELD MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE INSTALLATION ENVIRONMENT. 15. RACEWAYS BELOW DRIVEWAYS, PARKING LOTS, AND ANY RACEWAYS INSTALLED BELOW GRADE SHALL BE INSTALLED A MINIMUM OF 24" BELOW FINISHED GRADE PER NEC 300-5. B. GROUNDING 1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON-CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 250. 2. BOND METAL WATER PIPING AND OTHER METAL PIPING (INCLUDING GAS PIPING) AND EXPOSED STRUCTURAL METAL IN ACCORDANCE WITH NEC ARTICLE 250. 3. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. FIRE ALARM NOTES 1. PRINCIPAL OCCUPANCY CLASSIFICATION IS GROUP M. 2. SPACE IS PROVIDED WITH FULL SPRINKLER COVERAGE. 3. OCCUPANT LOAD IS LESS THAN 500. 4. THE LANDLORD DOES REQUIRE ALL TENANTS TO INSTALL A FIRE ALARM SYSTEM MONITORED BY THE LANDLORD SYSTEM. 5. A FIRE ALARM SYSTEM IS REQUIRED. ISSUE DATE 200275 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C COPYGRIHT 2020, CURRANARCHI TECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES NOT FOR CONSTRUCTION PRELIMINARY 02.12.2021 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM MULTI-TENANT BUILDING CARMEL, INDIANA 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317 . 288 . 0681 F :: 317 . 288 . 0753 T E S tesengineering.com E N G I N E E R I N G F 440 871 7954 P 440 871 2410 25760 First Street Cleveland, OH 44145 E0.2 ELECTRICAL SPECIFICATIONS 05/10/21