HomeMy WebLinkAboutE001.3106 VACANT 105 GARBANZO 104 RESTORE HYPER WELLNESS 103 RISE 'N ROLL 102 DRY CLEANER 101 TROPICAL SMOOTHIE CAFE A B 1 2 3 4 5 6 1 2 3 4 5 6 SCALE: 3/32" = 1'-0" 1 E1.1 ELECTRICAL PLAN 1 2 4 5 6 8 9 11 9 7 T1-4 T2-4 T3-4 T5a-4 PANEL T1 PANEL T2 PANEL T3 PANEL T5a WP GFI WP H-6 H-6 3 PANEL H 7 T4-4 PANEL T4 SHEET KEYNOTES 1 UTILITY TRANSFORMER, PAD AND GROUNDING BY EC TO UTILITY COMPANY SPECIFICATIONS. REFER TO SHEET E0.1 AND E1.2 FOR MORE INFORMATION. 2 LOCATION OF METER CENTER. FINAL APPROVED LOCATION SHALL BE VERIFIED WITH OWNER PRIOR TO INSTALLATION OF SERVICE EQUIPMENT. SEE ONE-LINE DIAGRAM (SHEET E-1.1) 3 120/208V, 200AMP LANDLORD PANEL, VERIFY LOCATION WITH OWNER PRIOR TO ROUGH-IN. 4 4" TELEPHONE BACKBOARD, VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. 5 UNDERGROUND SERVICE ENTRANCE CONDUITS. REFER TO DETAILS AND ONE LINE DIAGRAM ON SHEET E0.1 FOR MORE INFORMATION. 6 STUB OUT FOR CONNECTION TO TELEPHONE. COORDINATE WITH TELEPHONE COMPANY AND VERIFY CONNECTION LOCATION PRIOR TO INSTALLATION. REFER TO CIVIL PLANS FOR CONTINUATION. 7 400AMP, 120/208V PANEL FED FROM METER CENTER AT BACK OF BUILDING. REFER TO SHEET E-1.1 FOR ONE LINE DIAGRAM INFORMATION. 8 TWO 4" CONDUITS WITH PULLSTRING TO UTILITY POINT OF CONNECTION. COORDINATE EXACT REQUIREMENTS WITH ENERGY COMPANY. REFER TO ONE LINE DIAGRAM ON SHEET E0.1 FOR MORE INFORMATION. 9 200AMP, 120/208V PANEL FED FROM METER CENTER AT BACK OF BUILDING. REFER TO SHEET E-1.1 FOR ONE LINE DIAGRAM INFORMATION. 10 400AMP, 120/208V DISCONNECT FROM METER CENTER AT BACK OF BUILDING, PLUS TWO 200AMP PANELS. REFER TO SHEET E-1.1 FOR ONE LINE DIAGRAM INFORMATION. 11 STUB UP LOCATION FOR FUTURE TENANT SPACE, PROVIDE CONDUIT AND PULLSTRING FROM METER CENTER AT BACK OF BUILDING. REFER TO SHEET E-1.1 FOR ONE LINE DIAGRAM INFORMATION. 12 4" TELEPHONE SERVICE CONDUIT ROUTED OVERHEAD AND STUBBED IN TENANT SPACE. TELEPHONE CONDUCTORS SHALL BE FURNISHED AND INSTALLED FROM LANDLORD TELEPHONE BOARD TO TENANT SPACE AS INDICATED ON PLAN. 13 4" TELEPHONE SERVICE CONDUIT AND PULL WIRE. CONDUIT ROUTED OVERHEAD AND STUBBED IN TENANT SPACE. TELEPHONE CONDUCTORS SHALL BE FURNISHED AND INSTALLED FROM LANDLORD TELEPHONE BOARD TO TENANT SPACE BY THE TENANT AT A LATER DATE. 9 T6-4 PANEL T6 PANEL T5b 10 WP T1-6 T1-8 12 13 13 13 WP T3-6 13 13 KEY PLAN ISSUE DATE 200275 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C COPYGRIHT 2020, CURRANARCHI TECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES NOT FOR CONSTRUCTION PRELIMINARY 02.12.2021 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM MULTI-TENANT BUILDING CARMEL, INDIANA N PROJECT LOCATION WESTON POINTE DRIVE U.S. HIGHWAY 421 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317 . 288 . 0681 F :: 317 . 288 . 0753 T E S tesengineering.com E N G I N E E R I N G F 440 871 7954 P 440 871 2410 25760 First Street Cleveland, OH 44145 E1.1 ELECTRICAL PLAN (1) layin light fixture per 90 sf. add em and exit lights per work letters. please note to install outlets per tenant's plans 05/10/21