HomeMy WebLinkAboutP001.0GENERAL SHEET NOTES 1. EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS. 2. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 3. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. 4. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE CONTRACTOR SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. 5. PROTECT EQUIPMENT, FIXTURES, PIPING, DUCTWORK, ETC. INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY THE ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND THEN CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS. 6. WHERE PIPE, DUCTWORK, INSULATION, FIXTURES OR EQUIPMENT TO REMAIN IS DAMAGED OR DISTURBED, REMOVE THE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY AND QUALITY. WHERE IDENTICAL MATERIALS ARE UNAVAILABLE OR CANNOT BE USED, USE MATERIALS WHOSE INSTALLED PERFORMANCE EQUALS OR SURPASSES THAT OF THE EXISTING MATERIALS. 7. MAINTAIN AND RESTORE, IF INTERRUPTED BY DEMOLITION OR IN THE PATH OF NEW CONSTRUCTION, ALL UTILITIES PASSING THROUGH AND SERVING OUTSIDE OF DEMOLITION AREA. 8. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR "SMOKE TIGHT". SEAL AROUND ALL PENETRATIONS THROUGH RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 9. SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED PER NFPA 70. 10. PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE EXPOSED, CHROME PLATED PIPE IS TO BE USED. 11. ALL SANITARY PIPING INSTALLED UNDERGROUND IS TO BE PITCHED @ 1% SLOPE EXCEPT FOR 2" LINES WHICH SHALL BE PITCHED AT 2% SLOPE. 12. ALL GREASE WASTE PIPING INSTALLED UNDERGROUND IS TO BE PITCHED @ 2% SLOPE. 13. ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE. 14. PIPING IS NOT PERMITTED IN DEMISING WALLS. 15. ALL EXPOSED, EXTERIOR PIPING SHALL BE PAINTED WITH RUST INHIBITIVE PRIMER, COLOR CODED FINISH, AND IDENTIFICATION LABELS. 16. VERIFY NATURAL GAS AVAILABILITY AND CAPACITY. COORDINATE PRESSURE, SERVICE CONNECTION, AND METER INSTALLATION WITH THE LANDLORD AND LOCAL UTILITY COMPANY. 17. PROVIDE GAS PIPE SUPPORTS ON ROOF. PROVIDE 10'-0" ON CENTER AND AT ALL CHANGES OF DIRECTION. REFER TO DETAIL 6 ON THIS SHEET. 18. CLEAN AND REFURBISH EXISTING PLUMBING FIXTURES TO BE RE-USED. FIELD VERIFY EXISTING PLUMBING FIXTURES ARE IN PROPER WORKING ORDER. NOTIFY OWNER IMMEDIATELY SHOULD OPERATIONAL CHECK OF FIXTURES REVEAL ANY MAJOR COMPONENT FAILURES. 19. DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT. 20. ALL ACCESSIBLE P-TRAPS MUST BE PROVIDED WITH BOTTOM CLEANOUT PLUGS. 21. INSULATE EXPOSED P-TRAPS, HOT AND COLD VALVES AND PIPING SERVING HANDICAPPED LAVATORIES. 22. TENANT SPACES, THAT ARE UN-OCCUPIED AT TIME OF OPENING, ARE TO HAVE PROVIDED BY FIRE PROTECTION CONTRACTOR BRANCH PIPING AND SPRINKLER SPACING BASED ON THE ORDINARY HAZARD GROUP II OCCUPANCY PER NFPA 13. 23. ALL PIPING TO POINTS 5'-0" OUTSIDE THE BUILDING IS BY THE PLUMBING CONTRACTOR. 24. PROVIDE A WALL CLEANOUT AT THE BASE OF ALL VERTICAL STORM AND SANITARY RISERS 1'-0" AFF. 25. FINISHED FLOOR ELEVATION = XXX.00 26. ALL STORM PIPING OUTSIDE THE PERIMETER OF THE BUILDING REQUIRES COORDINATION WITH THE STRUCTURAL FOOTERS TO AVOID TRENCHING AND PIPE PLACEMENT WITHIN THE FOOTING ANGLE OF REPOSE. 27. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE SPACE. 28. CONTRACTOR SHALL VERIFY IF SPRINKLER HEADS UNDER STOCK SHELVING ARE REQUIRED. 29. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN LEAK PROOF AND FREE FROM DEFECTS PRIOR TO CONCEALMENT. 30. ALL FLOOR DRAINS AND CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. 31. ALL FLOOR SINKS ARE TO BE INSTALLED EITHER FLUSH WITH FINISHED FLOOR, OR RAISED PER LOCAL CODE REQUIREMENTS. ABBREVIATIONS TMV THERMOSTATIC MIXING VALVE UNLESS OTHERWISE NOTED UNDERWRITERS LABORATORIES, INC. MAKE-UP AIR MECHANICAL MANHOLE MANUFACTURER MINIMUM MOUNTEDMTD MUA MECH MFR MIN MH 1000 BTU PER HOUR MAXIMUM LOW PRESSURE POUNDS MAX MBH LBS, # LP HEIGHTH KITCHEN EQUIPMENT CONTRACTORKEC HEAD, HUB DRAIN HORSEPOWER HEATING, VENTILATING & A/C HYDRANT DOMESTIC HOT WATER HERTZ HVAC HYD HW HZ HD HP ELECTRICAL CONTRACTOR GALLON GALVANIZED GENERAL CONTRACTOR GREASE INTERCEPTOR GALLONS PER MINUTE GALLONS PER HOUR GALLONS PER DAY GAUGE GREASE WASTE GI GPD GPM GPH GW GAL GALV GC GA DEGREES FAHRENHEIT FOOT, FEET EXISTING FLOOR DRAIN FLEXIBLE FEET PER MINUTE FLOOR SINK FLOOR CLEANOUT EXHAUST °F FT FLEX FPM FCO FD FS EX EXH EC W/ W/O WC VTR WITH WATER COLUMN WITHOUT VENT THROUGH ROOF VAC UON U/F U/G U/S UL TYP VACUUM VENT UNDERGROUND UNDERSLAB UNDERFLOOR TYPICAL SQUARE FEET, SQUARE FOOT REVOLUTIONS PER MINUTE TOTAL STATIC PRESSURE STORM WATER POST INDICATOR VALVE POUNDS PER SQUARE INCH PRESSURE RELIEF VALVE REFLECTED CEILING PLAN REINFORCING, REINFORCED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. OUTSIDE STEM AND YOKE OCCUPATIONAL SAFETY & HEALTH ADMIN. AMERICAN WATER WORKS ASSOC.AWWA EXTERNAL STATIC PRESSURE ELECTRICAL ELEVATION EQUIPMENT ENCLOSURE DRAWING EACH ESP ENCL ELEC EQUIP ELEV EA DWG DOMESTIC COLD WATER DOWNSPOUT DIAMETER DEGREES DIMENSION DOWN DS DIA (OR Ø) DN DIM CW DEG SPEC SPECIFICATION THRU TP TSP TDH STD SUSP SURF ST SQ TOTAL DYNAMIC HEAD THROUGH TOTAL PRESSURE SUSPEND STANDARD SURFACE SQUARE SECT SHT SF RPM SECTION SHEET CONCRETE CENTERLINE COLUMN CLEANOUT CEILING CUBIC FEET PER MINUTE CUBIC FEET PER HOUR L CLG COL CO C CC CFM CFH ASSEMBLYASSY RD REQ REV REINF RCP ROOF DRAIN REQUIRED REVISION, REVISE PRV PSI PH, Ø PIV PLBG PD PLUMBING PRESSURE DROP PHASE AMERICAN NAT'L STANDARDS INSTITUTE AMERICAN SOCIETY OF TESTING & MATLS AMERICAN SOCIETY OF MECHANICAL ENGRS ABOVE FINISHED GRADE AUXILIARY ARCHITECT, ARCHITECTURAL AMERICAN WELDING SOCIETY ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED CEILING ASME ASTM AUX AWS AFG ARCH ANSI ADJ AFF AFC ABOVEABV OS&Y OSHA OD OC NFPA NTS N.O. NIC OVERFLOW DRAINAGE ON CENTER NOT TO SCALE NORMALLY OPEN NOT IN CONTRACT NEC NEMA N/A NOT APPLICABLE EXISTING TO REMAINETR REX REMOVE EXISTING CLEANOUT PLUGCOP OVERFLOW ROOF DRAINORD RWC RAIN WATER CONDUCTOR BOTTOM OF PIPE BUILDING BRITISH THERMAL UNIT BOTTOM OF STRUCTURE BUILDING AUTOMATION SYSTEM BLDG BOP BOS BTU BAS BELOW FLOOR BUILDING MANAGEMENT SYSTEMBMS DOMESTICDOM FIRE PROTECTIONFP FILTERED WATERFW GROUNDGRD MECHANICAL CONTRACTORMC OVERHEADO/H OPENINGOPNG REL RELOCATED SAN SANITARY DEPTHD GASG CONNECT, CONNECTIONCONN STUB UP FOR FUTURE DCV PLUMBING SYMBOLS GAS MANIFOLD LOCATION DOMESTIC WATER RISER PLUMBING FIXTURES DOUBLE CHECK BACKFLOW PREVENTER SPRINKLER HEAD (SEMI-RECESSED) SPRINKLER HEAD (FULLY-RECESSED) SPRINKLER HEAD (UPRIGHT) TENANT CONNECTION NORMALLY CLOSEDN.C. PB PUSH BUTTON DOMESTIC HOT WATER RETURNHWR B/F CONNECT TO EXISTINGCTE FINISHED FLOORFF RR REMOVE AND RELOCATE INSIDE DIAMETERID INVERT ELEVATION INCH, INCHES INCHES OF WATER COLUMN (GAS)IN w.c IN IE V OS&Y VALVE BALL VALVE ELBOW DOWN ELBOW UP UNION TEE OUTLET UP TEE OUTLET DOWN DIRECTION OF FLOW VALVE IN DROP EXPANSION JOINT GATE VALVE CALIBRATED BALANCING VALVE PIPE GUIDE 3-WAY SELF OPERATING VALVE BUTTERFLY VALVE PRESSURE REDUCING VALVE CHECK VALVE MOTOR OPERATED VALVE 2-WAY SELF OPERATING VALVE M HOSE BIB GREASE WASTEGW EXISTING PIPING TO REMAIN EXISTING PIPING TO BE REMOVED NEW PIPING / EQUIPMENT FS T&P RELIEF VALVE PRESSURE SWITCH CAP ON END LINE FLOW SWITCH PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION PIPE FLANGE THERMOMETER WELL GAS VALVE WALL CLEANOUT OR CLEAOUT PLUG FLOOR CLEANOUT WATER METERM GAS REGULATORR FLOOR SINK (FS) FLOOR DRAIN WITH P-TRAP DRAWING NOTE REFERENCE NEW TO EXISTING POINT OF CONNECTION - 1 PS (ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS) (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS) PIPING ABOVE FLOOR PIPING BELOW FLOOR SAN SANITARY PIPING OD RWC G OVERFLOW DRAIN PIPING HOT WATER (HW) PIPING COLD WATER (CW) PIPING NATURAL GAS PIPING HOT WATER RECIRCULATION (HWR) STORM PIPING (ABOVE GROUND) SANITARY VENT PIPINGV ST STORM PIPING (UNDERGROUND) ISSUE DATE 200275 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. COPYRIGHT 2020, CURRANARCHITECTUREC PROJECT INFORMATION CERTIFICATION ISSUE DATES NOT FOR CONSTRUCTION PRELIMINARY 02.12.2021 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM MULTI-TENANT BUILDING CARMEL, INDIANA 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317 . 288 . 0681 F :: 317 . 288 . 0753 T E S E N G I N E E R I N Gtesengineering.com F 440 871 7954 P 440 871 2410 25760 First Street Cleveland, OH 44145 P0.1 PLUMBING LEGEND, NOTES, DETAILS 05/10/21