Loading...
HomeMy WebLinkAboutA010.51 A 2 3 4 B 5 2 2 3 3 2 2 7 7 1 1 1 1 1 1 1 1 5 5 4 6 ROOF PLAN 1 1/4" = 1'-0" ROOF PLAN LEGEND DENOTES TAPERED INSULATION OR ROOF CRICKETS TO ROOF DRAIN LOCATIONS. SLOPE MIN OF 1 4"/FOOT AS INDICATED BY ARROWS OR TWICE THE AMOUNT OF THE UNDERLYING DECK WHICHEVER IS GREATER. DENOTES ROOF SLOPE 1 AT 4" / FOOT MINIMUM. ROOF TYPE #1 MECHANICALLY FASTENED 45 MIL TPO MEMBRANE WITH RIGID POLYISOCYANURATE INSULATION AT MINIMUM OF R-20. INSULATION TO BE TWO LAYERS WITH STAGGERED JOINTS. MEMBRANE SHEETS RUN PERPENDICULAR TO THE DECK FLUTES. FOAM PERIMETER OF INSULATION. SEE DETAIL. KEY PLAN ISSUE DATE 200311 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C COPYGRIHT 2021, CURRANARCHI TECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM OUTLOT BUILDING 11150 N. MICHIGAN ROAD CARMEL, INDIANA 46077 N PERMIT SET 02.25.2021 PROJECT LOCATION BENNETT PKWY U.S. H IGHWAY 421 REED RD. ROOF PLAN A120 KEYED NOTES 1. PREFINISHED METAL COPING, REFER TO WALL SECTIONS. (TYP.) 2. PROVIDE TAPERED INSULATION AS REQUIRED TO SLOPE ROOF DRAINAGE TOWARDS SCUPPER/DOWNSPOUT. 3. PRE-FINISHED METAL DOWNSPOUT AND SCUPPER. SEE DETAIL THIS SHEET. 4. FABRIC AWNING. REFER TO WALL SECTIONS AND ELEVATIONS. 5. METAL AWNING. REFER TO WALL SECTIONS AND ELEVATIONS. 6. ROOF ACCESS LADDER. SEE SECTION. 7. PRELIMINARY ROOF EQUIPMENT LOCATION. VERIFY IN STEEL SHOP DRAWINGS WITH FINAL TENANT LAYOUT. N 05/10/21