HomeMy WebLinkAboutA010.51
A
2 3 4
B
5
2
2
3
3
2
2
7 7
1
1
1
1 1
1
1
1
5
5
4
6
ROOF PLAN 1
1/4" = 1'-0"
ROOF PLAN LEGEND
DENOTES TAPERED INSULATION OR ROOF
CRICKETS TO ROOF DRAIN LOCATIONS.
SLOPE MIN OF
1
4"/FOOT AS INDICATED BY
ARROWS OR TWICE THE AMOUNT OF THE
UNDERLYING DECK WHICHEVER IS GREATER.
DENOTES ROOF SLOPE 1 AT
4" / FOOT
MINIMUM.
ROOF TYPE #1
MECHANICALLY FASTENED 45 MIL TPO
MEMBRANE WITH RIGID
POLYISOCYANURATE INSULATION AT
MINIMUM OF R-20. INSULATION TO BE TWO
LAYERS WITH STAGGERED JOINTS.
MEMBRANE SHEETS RUN PERPENDICULAR TO
THE DECK FLUTES. FOAM PERIMETER OF
INSULATION. SEE DETAIL.
KEY PLAN
ISSUE DATE
200311
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C COPYGRIHT 2021, CURRANARCHI TECTURE
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
OUTLOT BUILDING
11150 N. MICHIGAN ROAD
CARMEL, INDIANA
46077
N
PERMIT SET 02.25.2021
PROJECT
LOCATION
BENNETT PKWY
U.S. H IGHWAY 421
REED RD.
ROOF PLAN
A120
KEYED NOTES
1. PREFINISHED METAL COPING, REFER TO WALL SECTIONS. (TYP.)
2. PROVIDE TAPERED INSULATION AS REQUIRED TO SLOPE ROOF
DRAINAGE TOWARDS SCUPPER/DOWNSPOUT.
3. PRE-FINISHED METAL DOWNSPOUT AND SCUPPER. SEE DETAIL
THIS SHEET.
4. FABRIC AWNING. REFER TO WALL SECTIONS AND ELEVATIONS.
5. METAL AWNING. REFER TO WALL SECTIONS AND ELEVATIONS.
6. ROOF ACCESS LADDER. SEE SECTION.
7. PRELIMINARY ROOF EQUIPMENT LOCATION. VERIFY IN STEEL
SHOP DRAWINGS WITH FINAL TENANT LAYOUT.
N
05/10/21