HomeMy WebLinkAboutA010.10STAINLESS STEEL DRIP EDGE
CONCRETE SIDEWALK,
SEE CIVIL DRAWINGS
CONCRETE BLOCK VENEER
MEMBRANE FLASHING
1
2" EXPANSION AND SEALANT
2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS
SEE STRUCTURAL DRAWINGS FOR ALL FOUNDATION
AND FOOTING INFORMATION. ALL ELEMENTS ARE
SHOWN HERE FOR REFERENCE ONLY
CAVITY PROTECTION MATERIAL. FULL DEPTH OF
CAVITY
4" CONCRETE BLOCK
EXTERIOR SHEATHING
VAPOR BARRIER,
5
8" GYP. BD.
8" METAL STUD FRAMING
W/ R-21 INSULATION
ALIGN INTERIOR SIDE OF
STUD FRAMING WITH
INTERIOR SIDE OF CMU
SEE STRUCTURAL FOR
ALL SLAB, AND
SUBGRADE
REQUIREMENTS.
2" RIGID PERIMETER
INSULATION. EXTEND
TO BOTTOM OF
FOUNDATION.
FINISH FLOOR
SEE SECTIONS
SET SILL PLATE ON POLYETHYLENE FOAM SILL
GASKET (USE DOW MAN 'WEATHERMATE' FOAM
GASKET.)
WEEP TUBES W/ SCREENS @ 1 6" OC MAX
CUT FLASHING OFF FLUSH W/ FACE OF MASONRY
PROVIDE FLASHING MANU RECOMMENDED
TERMINATION DETAIL
SEE STRUCTURAL FOR
ALL SLAB, AND
SUBGRADE
REQUIREMENTS.
2" RIGID PERIMETER
INSULATION.
EXTEND TO BOTTOM
OF FOUNDATION. AT
STOREFRONT
LOCATIONS, EXTEND
HORIZONTALLY UNDER
SLAB 4'-0" MIN.
EXTRUDED ALUMINUM STOREFRONT
CONTINUOUS SEALANT
SHIM AS REQUIRED. PROVIDE SEALANT AND
BACKER ROD AT INSIDE AND OUTSIDE OF
FRAME.
SEE STRUCTURAL DRAWINGS FOR ALL
FOUNDATION AND FOOTING INFORMATION.
ALL ELEMENTS ARE SHOWN HERE FOR
REFERENCE ONLY
1
2" EXPANSION JOINT AND SEALANT
CONCRETE SIDEWALK, SEE CIVIL DRAWINGS
#
FINISH FLOOR
SEE SECTIONS
EXTEND MEMBRANE UP
BACK OF PARAPET,
OVER NAILER AND
SECURE AT FRONT FACE
OF NAILER.
SHEATHING AT
BACKSIDE OF PARAPET
8" METAL STUD FRAMING
2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS. AT
STONE ONLY, USE HUNTER XCI PLY W/
5
8"
SHEATHING OVER 1 " INSULATION.
PREFINISHED, PREFABRICATED
METAL COPING WITH
CONTINUOUS GALVANIZED
SEAT. ATTACHMENT METHODS
AND AMOUNTS MUST BE
COORDINATED WITH COPING
MANUFACTURER.
SEALANT
TREATED WOOD NAILER
SLOPE
STONE PANEL
6"
#
TO WALL
SEE SECTION
SEE STRUCTURAL
DRAWINGS
#
8" METAL STUD FRAMING
W/ R-21 INSULATION
EXTERIOR SHEATHING
2" EXTRUDED RIGID INSULATION,
PROVIDE MANUFACTURER'S JOINT
TAPE. COVER WITH AIR
INFILTRATION BARRIER. TAPE AIR
BARRIER JOINTS HUNTER XCI PLY W/
5
8" SHEATHING OVER 1 " INSULATION.
5
8" GYP. BD. OVER VAPOR
BARRIER
1 '-1 0 1 /2"
7' - 5 5/8"
RUNNING BOND
MODULAR BRICK
AIR SPACE
ROCK CAST VENEER
STONE PANEL BELOW.
BEON STONE ABOVE.
1 '-4"
3 5/8 " METAL STUD
FRAMING
RUNNING BOND MODULAR BRICK
CAST STONE & BEON
STONE CORNERS
PREFINISHED, PREFABRICATED
METAL COPING WITH
CONTINUOUS GALVANIZED
SEAT. ATTACHMENT METHODS
AND AMOUNTS MUST BE
COORDINATED WITH COPING
MANUFACTURER.
SEALANT
TREATED WOOD NAILER
2X
EXTEND MEMBRANE UP
BACK OF PARAPET,
OVER NAILER AND
SECURE AT FRONT FACE
OF NAILER.
SHEATHING AT
BACKSIDE OF PARAPET
8" METAL STUD FRAMING
SLOPE
2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS
MODULAR BRICK VENEER
#
SOLDIER BRICK VENEER
CELL VENTS @ 48" OC MAX.
SEE STRUCTURAL
DRAWINGS
6"
TO WALL
SEE SECTION
EXTEND MEMBRANE UP
BACK OF PARAPET,
OVER NAILER AND
SECURE AT FRONT FACE
OF NAILER.
SHEATHING AT
BACKSIDE OF PARAPET
8" METAL STUD FRAMING
HUNTER XCI PLY W/
5
8" SHEATHING OVER 1 "
INSULATION.
PREFINISHED, PREFABRICATED
METAL COPING WITH
CONTINUOUS GALVANIZED
SEAT. ATTACHMENT METHODS
AND AMOUNTS MUST BE
COORDINATED WITH COPING
MANUFACTURER.
SEALANT
TREATED WOOD NAILER
SLOPE
FIBER CEMENT PANEL
6"
#
TO WALL
SEE SECTION
SEE STRUCTURAL
DRAWINGS
3
5
8" METAL FRAMING
SHEATHING & AIR BARRIER
ANODIZED BREAK METAL TO
MATCH STOREFRONT
PLYWOOD
BTM STOREFRONT
SEE SECTION
STEEL BEAM/TUBE.
COORDINATE W/
STRUCTURE DRAWINGS
8" METAL STUD FRAMING
W/ R-21 INSULATION
5
8" GYP. BD. OVER VAPOR
BARRIER
BACKER ROD & SEALANT
WINDOW AS SCHEDULED
FLASHING
AIR INFILTRATION BARRIER TO WRAP TO
INTERIOR FACE OF FRAMING
METAL FURRING
STEEL MASONRY DRIP EDGE WINDOW AS SCHEDULED
SHIM AS REQUIRED
PRE-FINISHED METAL CANOPY 2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS.
1 '-0"
2'-6"
MODULAR BRICK
BRICK TIE, VERIFY SPACING
STEEL MASONRY DRIP EDGE
STEEL PLATE. SEE STRUCTURAL DRAWINGS
BACKER ROD & SEALANT
WINDOW AS SCHEDULED
SHIM AS REQUIRED
1 '-4"
MEMBRANE FLASHING
2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS
WEEP TUBES W/ SCREENS @ 16" OC MAX
PROVIDE FLASHING MANU RECOMMENDED
TERMINATION DETAIL
CAVITY PROTECTION MATERIAL. FULL
DEPTH OF CAVITY
AWNING
8" METAL STUD FRAMING
W/ R-21 INSULATION
EXTERIOR SHEATHING
SEE STRUCTURAL
DRAWINGS
5
8" GYP. BD. OVER VAPOR
BARRIER
1 '-4"
FLASHING
CONCRETE BLOCK VENEER
2" EXTRUDED RIGID INSULATION, PROVIDE
MANUFACTURER'S JOINT TAPE.
COVER WITH AIR INFILTRATION
BARRIER. TAPE AIR BARRIER JOINTS
8" METAL STUD FRAMING
W/ R-21 INSULATION
EXTERIOR SHEATHING
TREATED 2X CONTINUOUS
5
8" GYP. BD. OVER VAPOR
BARRIER
AIR INFILTRATION BARRIER TO WRAP TO
INTERIOR FACE OF FRAMING
BACKER ROD & SEALANT
WINDOW AS SCHEDULED
DETAIL 1
1 1 /2" = 1 '-0"
ISSUE DATE
200311
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C COPYGRIHT 2021, CURRANARCHI TECTURE
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
OUTLOT BUILDING
11150 N. MICHIGAN ROAD
CARMEL, INDIANA
46077
PERMIT SET 02.25.2021
SECTIONS AND DETAILS
A501
DETAIL 2
1 1 /2" = 1 '-0"
DETAIL 3
1 1 /2" = 1 '-0"
DETAIL 4
1 1 /2" = 1 '-0"
DETAIL 5
1 1 /2" = 1 '-0"
DETAIL 6
1 " = 1 '-0"
DETAIL 7
1 1 /2" = 1 '-0"
DETAIL 8
1 1 /2" = 1 '-0"
DETAIL 9
1 1 /2" = 1 '-0"
05/10/21