HomeMy WebLinkAboutE001.0ABBREVIATIONS
UNDERWRITERS LABORATORIES, INC.
UNDERGROUND
UNLESS OTHERWISE NOTED
MAXIMUM OVER CURRENT PROTECTION
MCB MAIN CIRCUIT BREAKER
METAL HALIDE
MINIMUM
MTD MOUNTED
MOCP
MIN
MH
LOCKED ROTOR AMPS
MINIMUM CIRCUIT AMPACITY
MAXIMUM
LIGHTING
MAX
MCA
LTG
LRA
KILOVOLT-AMPS
KILOWATT-HOUR
KILOWATTS
KVA
KWH
KW
HEATER
HVAC HEATING, VENTILATING & A/C
HTR
GENERAL CONTRACTOR
GFI, GFCI GROUND FAULT INTERRUPTER
GC
FOOT, FEET
ELECTRICAL WATER COOLER
EXISTING
FIRE ALARM
FULL LOAD AMPS
FIRE ALARM CONTROL PANEL
EXHAUST
FT
FACP
FLA
FA
EX, EXIST
EWC
EXH
W WATT, WIDTH
VA
UL
UON
UG
T/C
VOLT-AMPERE
TIME CLOCK
SQUARE FEET, SQUARE FOOT
REFLECTED CEILING PLAN
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MFR'S ASSOC.
NATIONAL FIRE PROTECTION ASSOC.
OCCUPATIONAL SAFETY &HEALTH ADMIN.
DWG DRAWING
DECIBEL
DIAMETER
DISCONNECT
DOWN
DIA
DN
DISC
dB
THRU THROUGH
SF
RTU
RR REMOVE AND RELOCATE
ROOF TOP UNIT
CLOSED CIRCUIT TELEVISION
CIRCUIT
CEILING
CABLE TELEVISION SYSTEM
CKT
CLG
CCTV
CATV
REV
RCP
REVISION
PVC
PF
PH
POLYVINYL CHLORIDE
POWER FACTOR
PHASE
AMERICAN NAT'L STANDARDS INSTITUTE
ABOVE FINISHED GRADE
ARCHITECT, ARCHITECTURAL
AUDIO/VISUAL
ABOVE FINISHED FLOOR
ABOVE FINISHED CEILING
A/V
AFG
ARCH
ANSI
AFF
AFC
OSHA
OC
NFPA
NTS
N.O.
NIC
ON CENTER
NOT TO SCALE
NORMALLY OPEN
NOT IN CONTRACT
NEC
NEMA
N/A NOT APPLICABLE
ETR EXISTING TO REMAIN
REX REMOVE EXISTING
BREAKER
BLDG BUILDING
BKR
BMS BUILDING MANAGEMENT SYSTEM
GROUND
POWER SYMBOLS
DRY TYPE TRANSFORMER, REFER TO PLANS FOR SIZE/VOLTAGE
DISCONNECT SWITCH UNFUSED: "AS" - INDICATES SWITCH SIZE (AMPS)
JUNCTION BOX - CEILING OR WALL MOUNTED
CIRCUITRY TURNING UP
INFLOOR/UNDERFLOOR OR UNDERGROUND CONDUIT AND WIRE
ELECTRICAL PANEL BOARD - 208Y/120V-3Ø-4W
ELECTRICAL PANEL BOARD - 480Y/277V-3Ø-4W
A-1 HOMERUN TO PANEL "A", CIRCUIT #1. PROVIDE 2#12AWG CONDUCTORS (MINIMUM
SIZE) AND 1#12AWG GROUNDING CONDUCTOR IN 3/4" CONDUIT (MINUMUM SIZE)
UNLESS OTHERWISE NOTED. REFER TO SPECIFICATIONS FOR ADDITIONAL
GROUNDING REQUIREMENTS.
DISCONNECT SWITCH FUSED: "AS" - INDICATES SWITCH SIZE (AMPS)
"AF" - INDICATES FUSE SIZE (AMPS)
DOUBLE DUPLEX RECEPTACLE
DUPLEX RECEPTACLE
C CONDUIT
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
AUX AUXILIARY
BAS BUILDING AUTOMATION SYSTEM
DDC DIRECT DIGITAL CONTROL
C/B CIRCUIT BREAKER
D DEEP, DEPTH
EC ELECTRICAL CONTRACTOR
FPC FIRE PROTECTION CONTRACTOR
HID HIGH INTENSITY DISCHARGE
L LENGTH
IBC INTERNATIONAL BUILDING CODE
LED LIGHT EMITTING DIODE
MECH MECHANICAL
MC MECHANICAL CONTRACTOR
N.C. NORMALLY CLOSED
P POLE
MCC MOTOR CONTROL CENTER
PB PUSH BUTTON
PC PLUMBING CONTRACTOR
A AMPERES
IN INCH, INCHES
DELTA
CT CURRENT TRANSFORMER
G,GRD
SE SERVICE ENTRANCE
XFMR TRANSFORMER
Y WYE
Δ
RM
AWG AMERICAN WIRE GAUGE
ADA AMERICANS WITH DISABILITIES ACT
CUBIC FEET PER MINUTE
CW COLD WATER
CFM
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
FARA FIRE ALARM REMOTE ANNUNCIATOR
MUA MAKE UP AIR
O/H OVERHEAD
RLA RUNNING LOAD AMPS
ROOM
RGS RIGID GALVANIZED STEEL
TRANS TRANSFORMER
TYP TYPICAL
UPS UNINTERRUPTED POWER SUPPLY
W/ WITH
WP WEATHERPROOF
DACT DIGITAL ALARM COMMUNICATING TRANSMITTER COMBINATION MOTOR STARTER/DISCONNECT SWITCH, REFER TO PLANS
FOR SIZING
GFCI DUPLEX OR DOUBLE DUPLEX RECEPTACLE
DUPLEX OR DOUBLE DUPLEX RECEPTACLE PROTECTED VIA GFCI BREAKER,
PROVIDE LABELING AS REQUIRED BY NEC
CONTROLLED DUPLEX OR DOUBLE DUPLEX RECEPTACLE
TOGGLE SWITCH DISCONNECT, 120/277V, 20A, 1-HP RATED UON
GFI
EXTERIOR JAVA HOUSE
ASSUMED 150KVA,120/208V
PAD MOUNTED UTILITY
TRANSFORMER
SCALE: NONE
1
E001
ONE LINE DIAGRAM
4#500KCMIL IN 4"C
PANEL
"J"
400A MCB
120/208V
F=10,569 (MAX)
SHEET KEYNOTES
1 PROVIDE 400AS/400AF NEMA 3R SERVICE ENTRANCE RATED DISCONNECT SWITCH. LABEL PER NEC.
4#500KCMIL,1#3GND IN 4"C
M
F=10,232 (MAX)
PROVIDE NEW CT CABINET AND METER
COORDINATE WITH UTILITY
REFER TO SERVICE GROUNDING
DETAIL ON THIS SHEET
#1/0
1
M
GROUNDED CONDUCTOR (NEUTRAL) FROM
UTILITY COMPANY TRANSFORMER
10' 10'
10'
WITHIN 5' OF WATER
ENTRANCE TO BUILDING
INCOMING CONDUIT GROUND
(IF STEEL CONDUIT)
EQUIPMENT GROUNDING BUS
EQUIPMENT BONDING JUMPER
ENCLOSURE GROUND
MAIN BONDING JUMPER (1/0)
PER NEC 250.102.(C)(1)
#6 AWG MINIMUM
10" X 2" X 1/4" COPPER GROUND BAR,
INSTALL ON TELEPHONE BACKBOARD WITH
(2) UL LISTED STANDOFF INSULATORS
BONDING JUMPER
SOURCE (DIRECT CONTACT WITH EARTH
FOR 10' OR MORE)
COPPER CLAD STEEL, 10' x 3/4" WITH TOP
OF ROD 6" BELOW FINISH GRADE
(TYPICAL)
CLAMPS SUITABLE FOR DIRECT
BURIAL (TYPICAL)
NON-METALLIC PROTECTIVE SLEEVE
CONNECTOR LISTED FOR PURPOSE
CONCRETE ENCASED ELECTRODE
(REINFORCING STEEL)
EXOTHERMIC
CONNECTION
(TYPICAL)
METAL FRAME OF
BUILDING STRUCTURE
BONDING JUMPER (1/0)
PER NEC 250.102.(C)(1)
GROUNDING ELECTRODE CONDUCTOR
(XXX) PER NEC 250.66
GROUNDED OR
NEUTRAL BUS
SERVICE EQUIPMENT
SCALE: NONE
2
E001
SERVICE GROUNDING AND BONDING DETAIL
ISSUE DATE
200311
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
NOT FOR CONSTRUCTION
PRELIMINARY
12.31.2020
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
OUTLOT BUILDING
CARMEL, INDIANA
5719 LAWTON LOOP E. DR.
#212 INDIANAPOLIS, IN 46216
O :: 317 . 288 . 0681
F :: 317 . 288 . 0753
T E S
tesengineering.com E N G I N E E R I N G
F 440 871 7954
P 440 871 2410
25760 First Street
Cleveland, OH 44145
E001
ELECTRICAL
LEGEND, NOTES, DETAILS
05/10/21