Loading...
HomeMy WebLinkAboutE001.0ABBREVIATIONS UNDERWRITERS LABORATORIES, INC. UNDERGROUND UNLESS OTHERWISE NOTED MAXIMUM OVER CURRENT PROTECTION MCB MAIN CIRCUIT BREAKER METAL HALIDE MINIMUM MTD MOUNTED MOCP MIN MH LOCKED ROTOR AMPS MINIMUM CIRCUIT AMPACITY MAXIMUM LIGHTING MAX MCA LTG LRA KILOVOLT-AMPS KILOWATT-HOUR KILOWATTS KVA KWH KW HEATER HVAC HEATING, VENTILATING & A/C HTR GENERAL CONTRACTOR GFI, GFCI GROUND FAULT INTERRUPTER GC FOOT, FEET ELECTRICAL WATER COOLER EXISTING FIRE ALARM FULL LOAD AMPS FIRE ALARM CONTROL PANEL EXHAUST FT FACP FLA FA EX, EXIST EWC EXH W WATT, WIDTH VA UL UON UG T/C VOLT-AMPERE TIME CLOCK SQUARE FEET, SQUARE FOOT REFLECTED CEILING PLAN NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. OCCUPATIONAL SAFETY &HEALTH ADMIN. DWG DRAWING DECIBEL DIAMETER DISCONNECT DOWN DIA DN DISC dB THRU THROUGH SF RTU RR REMOVE AND RELOCATE ROOF TOP UNIT CLOSED CIRCUIT TELEVISION CIRCUIT CEILING CABLE TELEVISION SYSTEM CKT CLG CCTV CATV REV RCP REVISION PVC PF PH POLYVINYL CHLORIDE POWER FACTOR PHASE AMERICAN NAT'L STANDARDS INSTITUTE ABOVE FINISHED GRADE ARCHITECT, ARCHITECTURAL AUDIO/VISUAL ABOVE FINISHED FLOOR ABOVE FINISHED CEILING A/V AFG ARCH ANSI AFF AFC OSHA OC NFPA NTS N.O. NIC ON CENTER NOT TO SCALE NORMALLY OPEN NOT IN CONTRACT NEC NEMA N/A NOT APPLICABLE ETR EXISTING TO REMAIN REX REMOVE EXISTING BREAKER BLDG BUILDING BKR BMS BUILDING MANAGEMENT SYSTEM GROUND POWER SYMBOLS DRY TYPE TRANSFORMER, REFER TO PLANS FOR SIZE/VOLTAGE DISCONNECT SWITCH UNFUSED: "AS" - INDICATES SWITCH SIZE (AMPS) JUNCTION BOX - CEILING OR WALL MOUNTED CIRCUITRY TURNING UP INFLOOR/UNDERFLOOR OR UNDERGROUND CONDUIT AND WIRE ELECTRICAL PANEL BOARD - 208Y/120V-3Ø-4W ELECTRICAL PANEL BOARD - 480Y/277V-3Ø-4W A-1 HOMERUN TO PANEL "A", CIRCUIT #1. PROVIDE 2#12AWG CONDUCTORS (MINIMUM SIZE) AND 1#12AWG GROUNDING CONDUCTOR IN 3/4" CONDUIT (MINUMUM SIZE) UNLESS OTHERWISE NOTED. REFER TO SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS. DISCONNECT SWITCH FUSED: "AS" - INDICATES SWITCH SIZE (AMPS) "AF" - INDICATES FUSE SIZE (AMPS) DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE C CONDUIT (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) AUX AUXILIARY BAS BUILDING AUTOMATION SYSTEM DDC DIRECT DIGITAL CONTROL C/B CIRCUIT BREAKER D DEEP, DEPTH EC ELECTRICAL CONTRACTOR FPC FIRE PROTECTION CONTRACTOR HID HIGH INTENSITY DISCHARGE L LENGTH IBC INTERNATIONAL BUILDING CODE LED LIGHT EMITTING DIODE MECH MECHANICAL MC MECHANICAL CONTRACTOR N.C. NORMALLY CLOSED P POLE MCC MOTOR CONTROL CENTER PB PUSH BUTTON PC PLUMBING CONTRACTOR A AMPERES IN INCH, INCHES DELTA CT CURRENT TRANSFORMER G,GRD SE SERVICE ENTRANCE XFMR TRANSFORMER Y WYE Δ RM AWG AMERICAN WIRE GAUGE ADA AMERICANS WITH DISABILITIES ACT CUBIC FEET PER MINUTE CW COLD WATER CFM EF EXHAUST FAN EMT ELECTRICAL METALLIC TUBING FARA FIRE ALARM REMOTE ANNUNCIATOR MUA MAKE UP AIR O/H OVERHEAD RLA RUNNING LOAD AMPS ROOM RGS RIGID GALVANIZED STEEL TRANS TRANSFORMER TYP TYPICAL UPS UNINTERRUPTED POWER SUPPLY W/ WITH WP WEATHERPROOF DACT DIGITAL ALARM COMMUNICATING TRANSMITTER COMBINATION MOTOR STARTER/DISCONNECT SWITCH, REFER TO PLANS FOR SIZING GFCI DUPLEX OR DOUBLE DUPLEX RECEPTACLE DUPLEX OR DOUBLE DUPLEX RECEPTACLE PROTECTED VIA GFCI BREAKER, PROVIDE LABELING AS REQUIRED BY NEC CONTROLLED DUPLEX OR DOUBLE DUPLEX RECEPTACLE TOGGLE SWITCH DISCONNECT, 120/277V, 20A, 1-HP RATED UON GFI EXTERIOR JAVA HOUSE ASSUMED 150KVA,120/208V PAD MOUNTED UTILITY TRANSFORMER SCALE: NONE 1 E001 ONE LINE DIAGRAM 4#500KCMIL IN 4"C PANEL "J" 400A MCB 120/208V F=10,569 (MAX) SHEET KEYNOTES 1 PROVIDE 400AS/400AF NEMA 3R SERVICE ENTRANCE RATED DISCONNECT SWITCH. LABEL PER NEC. 4#500KCMIL,1#3GND IN 4"C M F=10,232 (MAX) PROVIDE NEW CT CABINET AND METER COORDINATE WITH UTILITY REFER TO SERVICE GROUNDING DETAIL ON THIS SHEET #1/0 1 M GROUNDED CONDUCTOR (NEUTRAL) FROM UTILITY COMPANY TRANSFORMER 10' 10' 10' WITHIN 5' OF WATER ENTRANCE TO BUILDING INCOMING CONDUIT GROUND (IF STEEL CONDUIT) EQUIPMENT GROUNDING BUS EQUIPMENT BONDING JUMPER ENCLOSURE GROUND MAIN BONDING JUMPER (1/0) PER NEC 250.102.(C)(1) #6 AWG MINIMUM 10" X 2" X 1/4" COPPER GROUND BAR, INSTALL ON TELEPHONE BACKBOARD WITH (2) UL LISTED STANDOFF INSULATORS BONDING JUMPER SOURCE (DIRECT CONTACT WITH EARTH FOR 10' OR MORE) COPPER CLAD STEEL, 10' x 3/4" WITH TOP OF ROD 6" BELOW FINISH GRADE (TYPICAL) CLAMPS SUITABLE FOR DIRECT BURIAL (TYPICAL) NON-METALLIC PROTECTIVE SLEEVE CONNECTOR LISTED FOR PURPOSE CONCRETE ENCASED ELECTRODE (REINFORCING STEEL) EXOTHERMIC CONNECTION (TYPICAL) METAL FRAME OF BUILDING STRUCTURE BONDING JUMPER (1/0) PER NEC 250.102.(C)(1) GROUNDING ELECTRODE CONDUCTOR (XXX) PER NEC 250.66 GROUNDED OR NEUTRAL BUS SERVICE EQUIPMENT SCALE: NONE 2 E001 SERVICE GROUNDING AND BONDING DETAIL ISSUE DATE 200311 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C PROJECT INFORMATION CERTIFICATION ISSUE DATES NOT FOR CONSTRUCTION PRELIMINARY 12.31.2020 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM OUTLOT BUILDING CARMEL, INDIANA 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317 . 288 . 0681 F :: 317 . 288 . 0753 T E S tesengineering.com E N G I N E E R I N G F 440 871 7954 P 440 871 2410 25760 First Street Cleveland, OH 44145 E001 ELECTRICAL LEGEND, NOTES, DETAILS 05/10/21