Loading...
HomeMy WebLinkAboutE001.2SHEET KEYNOTES 1 PROVIDE JUNCTION BOX FOR A SIGNAGE. COORDINATE ADDITIONAL REQUIREMENTS WITH SIGANGE VENDOR. 2 SCALE: 1/4" = 1'-0" 1 E101 ELECTRICAL PLAN 1 A 2 3 4 B PANEL J J-1 TELEPHONE BOARD GENERAL POWER NOTES A. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INCREASED WIRE SIZES DUE TO FIELD CONDITIONS RESULTING IN EXTENDING CONDUIT PATHS. GROUND WIRE SIZES ARE REQUIRED TO BE ADJUSTED PER ARTICLE 250 OF THE NEC WHEN WIRES ARE INCREASED FOR VOLTAGE DROP. B. ALL BRANCH CIRCUIT WIRING SHALL BE #12 AWG UNLESS OTHERWISE NOTED AND IN CONDUIT/EMT. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. 1 ISSUE DATE 200311 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. C PROJECT INFORMATION CERTIFICATION ISSUE DATES NOT FOR CONSTRUCTION PRELIMINARY 12.31.2020 JDF DEVELOPMENT THE AVENUE AT BENNETT FARM OUTLOT BUILDING CARMEL, INDIANA 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317 . 288 . 0681 F :: 317 . 288 . 0753 T E S tesengineering.com E N G I N E E R I N G F 440 871 7954 P 440 871 2410 25760 First Street Cleveland, OH 44145 E101 ELECTRICAL PLAN 05/10/21